In order to clarify the connections and differences be.tween KES- F and FAST, fifteen polyester- based fab-rics were selected and the experiments were strictly mea-sured. The test results between the two systems in te...In order to clarify the connections and differences be.tween KES- F and FAST, fifteen polyester- based fab-rics were selected and the experiments were strictly mea-sured. The test results between the two systems in termsof mechanical properties were compared, and highly sig-nificant correlation between two systems were obtaineddespite some considerable differences in the measurementprinciples of KES - F and FAST systems.展开更多
Doped elements in alloys significantly impact their performance.Conventional methods usually sputter the surface material of the sample,or their performance is limited to the surface of alloys owing to their poor pene...Doped elements in alloys significantly impact their performance.Conventional methods usually sputter the surface material of the sample,or their performance is limited to the surface of alloys owing to their poor penetration ability.The X-ray K-edge subtraction(KES)method exhibits great potential for the nondestructive in situ detection of element contents in alloys.However,the signal of doped elements usually deteriorates because of the strong absorption of the principal component and scattering of crystal grains.This in turn prevents the extensive application of X-ray KES imaging to alloys.In this study,methods were developed to calibrate the linearity between the grayscale of the KES image and element content.The methods were aimed at the sensitive analysis of elements in alloys.Furthermore,experiments with phantoms and alloys demonstrated that,after elaborate calibration,X-ray KES imaging is capable of nondestructive and sensitive analysis of doped elements in alloys.展开更多
文摘In order to clarify the connections and differences be.tween KES- F and FAST, fifteen polyester- based fab-rics were selected and the experiments were strictly mea-sured. The test results between the two systems in termsof mechanical properties were compared, and highly sig-nificant correlation between two systems were obtaineddespite some considerable differences in the measurementprinciples of KES - F and FAST systems.
基金supported by the National Key Research and Development Program of China(Nos.2017YFA0403801,2017YFA0206004,2018YFC1200204)the National Natural Science Foundation of China(NSFC)(Nos.81430087,11775297,U1932205).
文摘Doped elements in alloys significantly impact their performance.Conventional methods usually sputter the surface material of the sample,or their performance is limited to the surface of alloys owing to their poor penetration ability.The X-ray K-edge subtraction(KES)method exhibits great potential for the nondestructive in situ detection of element contents in alloys.However,the signal of doped elements usually deteriorates because of the strong absorption of the principal component and scattering of crystal grains.This in turn prevents the extensive application of X-ray KES imaging to alloys.In this study,methods were developed to calibrate the linearity between the grayscale of the KES image and element content.The methods were aimed at the sensitive analysis of elements in alloys.Furthermore,experiments with phantoms and alloys demonstrated that,after elaborate calibration,X-ray KES imaging is capable of nondestructive and sensitive analysis of doped elements in alloys.