期刊文献+
共找到25,784篇文章
< 1 2 250 >
每页显示 20 50 100
Clinical Effectiveness of the Plate Screw Internal Fixation Technique in the Treatment of Patients with Traumatic Fractures of Long Bones in the Lower Extremities
1
作者 Yong Cai 《Proceedings of Anticancer Research》 2024年第3期115-120,共6页
Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 20... Objective: To investigate the effectiveness of the plate screw internal fixation technique on the clinical outcomes of patients with traumatic fractures of long bones in the lower extremities. Methods: From January 2022 to December 2023, 70 patients with traumatic fractures of long bones in the lower extremities were admitted to the hospital and randomly divided into two groups: the control group and the observation group, each consisting of 35 cases. The control group underwent traditional closed interlocking intramedullary nailing, while the observation group received internal fixation with steel plates and screws. Relevant surgical indicators, treatment effectiveness, and postoperative complication rates were compared between the two groups. Results: The observation group exhibited significantly short surgical duration (80.65 ± 5.01 vs. 88.36 ± 5.26 minutes), fracture healing time (13.27 ± 0.32 vs. 15.52 ± 0.48 weeks), and hospitalization days (10.49 ± 1.13 vs. 16.57 ± 1.15 days) compared to the control group (P = 0.000). The effective treatment rate was significantly higher in the observation group (29/82.86%) than in the control group (21/60.00%), with a significant difference observed (χ2 = 4.480, P = 0.034). Additionally, the complication rate in the observation group (2/5.71%) was significantly lower than that in the control group (8/22.86%), with a correlated difference (χ2 = 4.200, P = 0.040). Conclusion: The plate screw internal fixation technique demonstrates significant clinical efficacy in treating traumatic fractures of long bones in the lower extremities. It improves the healing rate, reduces complications, and represents a safe and effective treatment strategy worthy of widespread use and application. 展开更多
关键词 Plate screw internal fixation technique Traumatic fractures Long bones in the lower extremities EFFECTIVENESS
下载PDF
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
2
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 Volar plate internal fixation Closed reduction External fixation PLASTER SPLINT Distal radius fracture Meta analysis
下载PDF
关于Rigid Internal Fixation一词译法和应用的说明
3
作者 顾晓明 《中国口腔颌面外科杂志》 CAS 2004年第1期21-21,共1页
关键词 igid internal fixation RIF 内固定 口腔颌面部 力学设计
下载PDF
Application of internal fixation of steel-wire limited loop in early Achilles tendon rupture 被引量:10
4
作者 Zhe Chen Jia-Sen Wei +3 位作者 Zhao-Yang Hou Jiong Hu Yan-Guang Cao Qi-Xin Chen 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第11期902-907,共6页
Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of... Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop.The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair,and the loops were removed after 3-5 months.Six months later,the condition of complications including Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis,cutaneous sensation in sural nerve dominance region,time back to preinjury work or learning as well as time to physical activities were observed.One year later,the therapeutic effect was evaluated,and the maximum circumferences of bilateral legs and raptured plane circumferences of Achilles tendon were measured.Results:The wound of all patients healed well,no complications like Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis occured,and the cutaneous sensation in sural nerve dominance region was normal.The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks.Seventy out of 76 patients(92.1%) achieved an excellent effect,and 6(7.9%) good effect.The excellent and good rate came up to 100%.The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside,while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.Conclusions:Kor early Achilles tendon rupture,internal fixation of steel-wire limited loop can recover the ankle function better,return to the preinjury state in the shortest lime,and has few complications. 展开更多
关键词 ACHILLES TENDON rupture Steel-wire LIMITED LOOP internal fixation ANKLE function
下载PDF
Open reduction and internal fixation for radial head fractures: A prospective observational study 被引量:4
5
作者 Imran Khan Mangi Arslan Ahmed Abro +4 位作者 Muhammad Naveed Memon Shahjahan Siyal Naveed Khan Nouman Memon Muhammad Kazim Rahim Najjad 《Journal of Acute Disease》 2020年第4期166-169,共4页
Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to J... Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to July 2017 at Liaquat National Hospital and Medical College, Karachi. Altogether, 28 patients with radial head and neck fractures were enrolled in our study. These patients were admitted to the hospital and their fractures were fixed with open reduction and internal fixation. Baseline information of the patients was collected, and patient-rated elbow evaluation scores were calculated. Results: Out of the 28 patients, 21 were male and 7 were female. Besides, 16 fractures were on the right side and 12 were on the left side and 17 involving the dominant hands. In addition, 8 patients had Mason type Ⅱ fracture and 20 had Mason type Ⅲ fracture. The mean age of patients was (31.0 ± 8.0) years, and the mean follow-up is (1.2 ± 0.5) years. The mean average patient-rated elbow evaluation scores were (27.64 ± 1.60) at 1-year follow-up. Conclusions:The majority of the patients who had radial head fractures and treated by open reduction and internal fixation have attained an excellent range of motion postoperatively. 展开更多
关键词 Radial head fractures Open reduction and internal fixation Functional outcome
下载PDF
Comparative study of various internal fixation methods for treating patellar fractures by three-dimensional photoelasticity 被引量:2
6
作者 许硕贵 苏佳灿 +4 位作者 张春才 曾伟明 顾绍德 张林春 方如华 《Journal of Medical Colleges of PLA(China)》 CAS 2003年第6期384-387,共4页
Objective: To compare the biomechanical basis of 3 different internal fixation methods: nitinol patellar concentrator (NT-PC), tension band and wire circle in treating patellar fractures. Methods: The epoxy resin thre... Objective: To compare the biomechanical basis of 3 different internal fixation methods: nitinol patellar concentrator (NT-PC), tension band and wire circle in treating patellar fractures. Methods: The epoxy resin three dimensional photoelasticity patellar models were made by precise moulding, and were fixated by nitinol patellar concentrator (NT-PC), tension band and wire circle respectively. The patellar models with frozen stress stripes were put into the polarized light field and the stress distributions were compared. As for the model fixated by NT-PC, by dividing layer, photographing and tracing, we used the iterative method to calculate the stress value of every internal node of the epoxy resin patellar model, and the character of stress was analyzed. Results: An overall stress field was yielded when the patellar model was fixated by NT-PC, and the stripes were more than that of tension band model and wire circle model, which have only few stress stripes in the fixated layers. Further analysis indicated that there were continuous fixated stresses in the facies articularis and distal pole of patella, and the character of stresses produced by NT-PC were mainly in longitudinal direction, then in transverse direction. The shearing stresses were small. Conclusion: The initiative and continuous memorial stress of NT-PC and its overall stress distribution character are the essence of NT-PC distinguished with tension band and wire circle in treating patellar fractures. The stress character produced by NT-PC is good for the stability of fracture site and prompts fracture healing. 展开更多
关键词 internal fixation patellar fracture PHOTOELASTICITY STRESS nitinol patellar concentrator
下载PDF
The Use of Calcaneal Anatomic Plate in Arthroscopically-assisted Open Reduction and Internal Fixation of Intra-articular Calcaneal Fractures 被引量:1
7
作者 王洪 张青松 +1 位作者 段德宇 严力军 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第3期319-321,共3页
To discuss and evaluate the method and effect of using calcaneal anatomic plate in treatment of intra-articular fractures of the calcaneus with assistant of arthroscope, 86 intra-articular fractures of the calcaneus i... To discuss and evaluate the method and effect of using calcaneal anatomic plate in treatment of intra-articular fractures of the calcaneus with assistant of arthroscope, 86 intra-articular fractures of the calcaneus in 78 patients were reduced by open reduction, and rigid fixation was made with calcaneal anatomic plate under assistant of arthroscope. The average follow-up duration was 18 months (range 12-30 months). The effect of treatment was evaluated according to AOFAS and X-ray before and after operation. The results showed that 86 patients have obtained satisfactory reduction according to X-ray, and there was significant difference before and after operation (P〈0. 01), the total excellent and fine rate was 91.86%. Treating intra-articular fractures of the calcaneus with calcaneal anatomic plate under arthroscope may provide more chance to achieve anatomical reconstruction, which can lead to satisfied recovery of function and few complication. 展开更多
关键词 Fracture of Calcaneus Calcaneal Anatomic Plate ARTHROSCOPE internal fixation
下载PDF
Functional Outcomes of Traumatic Complex Acetabulum Fractures with Open Reduction and Internal Fixation: 200 Cases 被引量:3
8
作者 Keykhosro Mardanpour Mahtab Rahbar +2 位作者 Maryam Rahbar Nyosha Mardanpour Sourena Mardanpour 《Open Journal of Orthopedics》 2016年第12期363-377,共15页
Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We ana... Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We analyzed a case series of patients with open reduction and internal fixation (ORIF) for complex acetabular fractures. Two hundred patients (132 men, 68 women) in four age groups including with a mean age of 43.39 ± 6.18 years (range 20 - 59 years) and a mean follow-up of 82.34 ± 12.48 months (range 18 - 109 months) met the inclusion criteria. Functional outcome at final follow-up was graded assessed according to Harris score. Factors affecting were defined. Results: Anatomic reduction was achieved in 192 hips, imperfect in 8 and poor in none. Radiological outcome revealed excellent results in 128 (64%) hips, good in eight, fair in five and none in poor. Harris score were excellent in 139 (69.5%) hips, good in 43 (21.5%) and fair in 18 (9%) and poor in none. The anatomical reduction results had a favorable final functional outcome. (0.003) However, BMI (P Conclusion: Optimal functional and radiological outcomes have been achieved with anatomic postoperative reduction. Also experience of specialist, on time surgery and good recovery lead to receiving excellent functional outcome with at least complications. 展开更多
关键词 Complex Acetabular Fracture internal fixation Open Reduction OUTCOME
下载PDF
Triple Arthrodesis with Internal and External Fixation: Technique Paper 被引量:1
9
作者 Luis E. Marin Randy Semma Nisha Bala Krishnan 《Surgical Science》 2014年第4期183-192,共10页
Background: The triple arthrodesis was described early by Myerson in 1923 and has been the gold standard surgical procedure for various conditions with the goal to reduce pain, improve deformity and facilitate functio... Background: The triple arthrodesis was described early by Myerson in 1923 and has been the gold standard surgical procedure for various conditions with the goal to reduce pain, improve deformity and facilitate function. Methods: The procedure consists of fusion of the subtalar joint, talonavicular joint and calcaneocuboid joint [1]. The procedure is traditionally done with internal fixation, however, Marinet al. has shown it to be performed with external fixation [2]. Dr. Marin and the associates have developed an alternative technique to perform a triple arthrodesis using internal and external fixation. This paper describes a step-by-step technique to perform a triple arthrodesis with both internal and external fixation. It will demonstrate the use of the prefabricated arches on the footplate for more precise and accurate placement of transosseous wires using arch-wire technique [3]. Results/Conclusion: We believe this technique will not only help increase the ability to achieve fusion with a less chance of non-union, but may also decrease healing time, which may allow patients to be mobile from the first week post-operatively and may diminish the risks associated with being non-weightbearing. 展开更多
关键词 Triple ARTHRODESIS Podiatric Medicine Surgery External fixation internal fixation WALKING TECHNIQUE PODIATRY
下载PDF
APPLICATION OF INTERNAL FIXATION IN THE TREATMENT FOR TUBERCULOSIS OF THE SPINE 被引量:1
10
作者 赵宏 翁习生 +3 位作者 沈建雄 叶启彬 邱贵兴 李世英 《Chinese Medical Sciences Journal》 CAS CSCD 1994年第3期179-182,共4页
This is a study of 18 patients who had surgical treatment for spinal tuberculosis. All patients were admitted with the spinal tuberculosis and treated with a combination of anterior debridement and bone graft with po... This is a study of 18 patients who had surgical treatment for spinal tuberculosis. All patients were admitted with the spinal tuberculosis and treated with a combination of anterior debridement and bone graft with poterior internal fixaton using the Luque or Dick technique. The patients were able to walk within a few days postoperation. Three to seven years follow-ups show no recurrence. kyphosis and/or solid fusinon. 展开更多
关键词 spinal tubercuosis internal fixation
下载PDF
THE SYNTHESIS AND CHARACTERIZATION OFPOLY-L-LACTIDE USED FOR THE INTERNALFIXATION OF BONE FRACTURE 被引量:2
11
作者 Zhang Zhengpu Lu ge +1 位作者 Wu Zhizhong He Binglin 《Chinese Journal of Reactive Polymers》 1998年第2期1-6,共6页
A high Mw of PLLA was synthesized, it intended to be used in the manufacture ofbioabsorbable screw applied in bone fracture internal fixation. The optical reactionconditions have been discussed.
关键词 Poly-L-lactic acid BIOABSORBABLE Bone fracture internal fixation
下载PDF
Effects of bridge combined internal fixation system internal fixation on fracture healing and shoulder joint function in elderly patients with displaced midshaft clavicle fractures 被引量:1
12
作者 Wang Guang-Xin Xiao Wan-Jun +1 位作者 Wang Chen Liang Qing-Wei 《Journal of Hainan Medical University》 2019年第18期35-39,共5页
Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphaticall... Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphatically observing fracture healing and shoulder joint function.Methods:Totally 44 elderly patients with Robinson type 2B displaced midshaft clavicle fractures were included from the Department of Orthopaedics,Shenyang Fourth People's Hospital during February 2016 and December 2018,including 23 males and 21 females,mean age(69.8±10.2)years old.The patients were divided into a bridge combined internal fixation system group(bridge group,n=22)and a locking compression plate internal fixation group(plate group,n=22)according to the internal fixation methods.The operation time,intraoperative blood loss,fracture healing time,and postoperative complications were recorded.At 12 months after surgery,the shoulder joint Constant-Murley score and DASH score were used to assess the recovery of joint function.The serum levels of bone turnover biochemical markers procollagen I N-terminal peptide(P1NP),cross-linked Carboxy-terminal telopeptide of typeⅠcollagen(CTX-I),and osteoblast specific factor(OSF)were measured before and 3 months after surgery.Results:The operation time,intraoperative blood loss and fracture healing time of the bridge group were significantly shorter than those of the plate group(P<0.05).Constant scores and DASH scores in the bridge group were significantly better than those of the plate group at 12 months after surgery(P<0.05).Serum levels of CTX-I was significantly decreased,while the P1NP and OSF were significantly increased compared with before surgery in the both groups(P<0.05),and the changes were more obvious in the bridge group(P<0.05).The incidence of complications was similar between the two groups(P<0.05).Conclusion:Compared with the locking plate system,the bridge combined internal fixation system can effectively improve the operation efficiency,have more benefits on fracture healing,better promote the recovery of patients'function,and reduce the failure rate of internal fixation,thus providing a better choice to treat displaced midshaft clavicle fractures by intraoperative internal fixation. 展开更多
关键词 BRIDGE COMBINED internal fixation Locking plate old age Mid-clavicular displacement FRACTURE internal fixation FRACTURE healing shoulder function Bone turnover
下载PDF
Effect of AXIS lateral mass screw-plate internal fixation system on functional recovery of spinal cord in fracture of lower cervical vertebrae 被引量:4
13
作者 昌耘冰 尹庆水 +5 位作者 夏虹 吴增晖 徐国洲 张余 权日 章凯 《中国临床康复》 CSCD 2003年第6期998-999,T004,共3页
AIM:To evaluate the methods and results of the AXIS lateral mass screw plate system in the treating of lower cervical spine injury.METHODS:29 cases of lower cervical vertebrae injury were fixed with AXIS system.All of... AIM:To evaluate the methods and results of the AXIS lateral mass screw plate system in the treating of lower cervical spine injury.METHODS:29 cases of lower cervical vertebrae injury were fixed with AXIS system.All of them were followed up for more than 1 year.RESULTS:All cases had a good bone union without malformation.We found no complication of the injury to the vertebral arteries or nerves.There was no loosening of the plate and screw. CONCLUSION:AXIS lateral mass screw plate system has the characteristic of stable,simple and safe and is suitable for the treatment of lower cervical spine injury. 展开更多
关键词 AXIS侧板钢板螺钉 内固定系统 下颈椎骨折脱位 颈髓功能恢复
下载PDF
Observation on the Efficacy of Autologous Blood Transfusion Combined with Controlled Hypotension in Patients with Spinal Internal Fixation during the Outbreak of New Coronavirus Pneumonia in Western Guangxi (in Guixi) 被引量:1
14
作者 Chengkua Huang Guosheng Su +3 位作者 Yong Zhao Chunxian Lu Sheng Nong Xiaohua Huang 《Open Journal of Blood Diseases》 2021年第1期15-23,共9页
<strong>Objective: </strong>To explore the therapeutic effect of autologous blood reinfusion combined with controlled hypotension in surgical spinal fixation during the outbreak of COVID-19. <strong>... <strong>Objective: </strong>To explore the therapeutic effect of autologous blood reinfusion combined with controlled hypotension in surgical spinal fixation during the outbreak of COVID-19. <strong>Methods: </strong>30 patients with spinal internal fixation autologous blood transfusion combined with controlled hypotension were selected as the subjects during the epidemic period from December 2019 to June 2020 in our hospital and during the operation, on the basis of routine blood pressure reduction, the American Haemonetice Corporation autologous blood continuous reinfusion system was used to infuse the blood recovered during the operation to the patient through filtration and other procedures. <strong>Results:</strong> 30 patients had no complications such as fever and hemolysis;And after the operation, the tube was dialed according to the drainage volume, the cervical thoracic and lumbar brace was customized, and the patient walked on the ground for one week;After no abnormalities, the patient was discharged. Intraoperative comparison of white blood cells (WBC), red blood cells (RBC), red blood cell pressure (HCT), hemoglobin (HGB), and coagulation time (PT) of patients with autologous blood before and after transfusion showed statistically significant differences before and after surgery (P < 0.001). <strong>Conclusion:</strong> During the new coronavirus pneumonia epidemic, the internal fixation of spinal surgery used a recovery machine to collect intraoperative blood for reinfusion. Intraoperative antihypertensive drugs were used to control blood pressure within a certain safe range. The postoperative clinical observation effect was significant and safe;especially at present the clinical significance during the epidemic was significant. 展开更多
关键词 New Coronavirus Pneumonia Spinal internal fixation Surgery Autologous Blood Reinfusion Controlled Hypotension Curative Effect
下载PDF
Modified Closed Reduction and Percutaneous Kirschner Wires Internal Fixation for Treatment of Supracondylar Humerus Fractures in Children 被引量:5
15
作者 Shu-bin WANG Bin-hui LIN +4 位作者 Wei LIU Guo-jun WEI Zong-guang LI Nai-chun YU Guang-rong JI 《Current Medical Science》 2021年第4期777-781,共5页
Objective Supracondylar humerus fractures are the most frequent fractures of the paediatric elbow.The present study introduced a modified surgical procedure for treatment of supracondylar humerus fractures in children... Objective Supracondylar humerus fractures are the most frequent fractures of the paediatric elbow.The present study introduced a modified surgical procedure for treatment of supracondylar humerus fractures in children.Methods From February 2015 to August 2019,73 patients with Gartland’s type II and III supracondylar fractures were treated with this modified method.Totally,68 of all patients were followed up for 3–12 months(mean 8.25 months).The evaluation results included fracture nonunion,ulnar nerve injury,pin track infection,carrying angle and elbow joint Flynn score.Results The results showed that bone union was observed in all children,one case had an iatrogenic ulnar nerve injury,and the symptoms were completely relieved in 4 months after removing of the medial-side pin.All children had no cubitus varus deformity and no pin track infection,and the rate of satisfactory results according to Flynn’s criteria score was 100%.Conclusion The modified closed reduction and Kirschner wires internal fixation could effectively reduce the rate of open reduction,the risk of iatrogenic ulnar nerve injury,and the incidence of cubitus varus deformity in treatment of supracondylar humerus fractures in children. 展开更多
关键词 supracondylar humerus fractures closed reduction Kirschner wires internal fixation surgical method
下载PDF
Comparison of Clinical Effect of PFNA and Internal Fixation with Anatomical Locking Plate of Proximal Femur in Treatment of Intertrochanteric Fracture of Femur 被引量:1
16
作者 Lu Wanqing Xiang Qingtian +2 位作者 Yu Yajun Wang Chunhua Wang Jiafei 《Journal of Clinical and Nursing Research》 2018年第2期23-26,共4页
Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated... Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results:The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion:The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal. 展开更多
关键词 INTERTROCHANTERIC fracture of FEMUR ANATOMICAL locking plate of PROXIMAL FEMUR PROXIMAL FEMORAL NAIL Antirotation internal fixation surgery Therapeutic effect
下载PDF
Effect of internal fixation and other methods alleviating low back pain caused by isthmic spondylolisthesis 被引量:2
17
作者 袁岱军 靳安民 吴广森 《中国临床康复》 CSCD 2003年第6期1032-1033,共2页
AIM:To explore the long term therapeutic effects of surgical treatment for isthmic spondylolisthesis.METHODS:42 cases of isthmic spondylolisthesis were analyzed retrospectively among which 13 cases underwent simple lu... AIM:To explore the long term therapeutic effects of surgical treatment for isthmic spondylolisthesis.METHODS:42 cases of isthmic spondylolisthesis were analyzed retrospectively among which 13 cases underwent simple lumbar interlaminar bone implant and 29 cases underwent transpedicular fixation combined with bone implantation.Assessment was made according to JOA standards before and after treatment.RESULTS:At a 3 years of follow up assessment,the functional outcome in transpedicular fixation assessed by JOA was excellent and good in 79.3%as compared with the group without fixation in which the excellent and good result was 76.9%.The level of pain and functional disability were similar in the two groups,but fusion rate in the group with transpedicular fixation was higher than that in group without it.CONCLUSION:Surgical treatment for isthmic spondylolisthesis improves function and relieves pain. 展开更多
关键词 内固定 腰椎峡部不连 滑脱 腰痛 治疗
下载PDF
A Study of the Mechanical Characteristics of a Mandibular Parasymphyseal Fracture with Internal Fixation Device Subject to Variable Bite Forces: Finite Element Analysis
18
作者 Victor Caraveo Scott Lovald Tariq Khraishi 《Journal of Biosciences and Medicines》 2021年第4期158-178,共21页
In recent times, research into mandibular fracture has gained momentum from advances in scanning techniques, software/algorithm developments and improvements, and numerical structural modeling using the finite-element... In recent times, research into mandibular fracture has gained momentum from advances in scanning techniques, software/algorithm developments and improvements, and numerical structural modeling using the finite-element method (FEM). In this work, the FEM is used to model a mandibular fracture (using an inhomogeneous and orthotropic jaw model) simulating the effect of different bite tasks/forces on the stability of the fixated fracture. Specifically, bilateral and unilateral clenches (using muscle data) were studied using a low-profile 3D 4 × 2 hole mini-plate deployed for fracture fixation. Here, the mandible bone was treated as orthotropic and spatially inhomogeneous. Although the results of stress and displacement analyses, for this fixation hardware, indicate sufficient fixation under normal biting conditions, the results show that the unilateral and ipsilateral bites develop, in general, the highest stresses or displacements. Such results can guide post-surgery recommendation on bite behavior. 展开更多
关键词 MANDIBLE Mandibular Fracture internal fixation Finite-Element Modeling Bite Forces
下载PDF
Internal fixator vs external fixator in the management of unstable pelvic ring injuries:A prospective comparative cohort study 被引量:1
19
作者 Mohamed Abo-Elsoud Mostafa I Awad +2 位作者 Mahmoud Abdel Karim Sherif Khaled Mohamed Abdelmoneim 《World Journal of Orthopedics》 2023年第7期562-571,共10页
BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using e... BACKGROUND Reconstruction of the pelvic ring anatomy in unstable anterior pelvic ring injuries is a significant step to reduce the mortality rate associated with these injuries efficiently.There is a debate on using either an anterior subcutaneous pelvis internal fixator(INFIX)or an anterior supra-acetabular external fixator(EXFIX)to manage an unstable anterior pelvic ring fracture.AIM To compare the functional and radiological outcomes and complications of INFIX vs EXFIX in managing unstable pelvic ring injuries.METHODS A prospective cohort study included 54 patients with unstable pelvic ring fractures.The patients were divided into two groups;the INFIX group,in which 30 cases were fixed by INFIX,and the EXFIX group,in which 24 patients were treated by EXFIX.The average age in the EXFIX group was 31.17 years(16-57 years),while in the INFIX group,it was 34.5 years(17-53 years).The study included 20(66.7%)males and 10(33.3%)females in the INFIX group and 10(41.7%)males and 14(58.3%)females in the EXFIX group.The radiological outcomes were evaluated using Matta and Tornetta's score,and the functional outcomes using the Majeed score.RESULTS The results revealed a statistically significant difference between both groups(P=0.013)regarding radiological outcomes,according to Matta and Tornetta's score in favor of the INFIX group.Sitting,standing,and walking abilities were measured at a 3-mo follow-up visit using Majeed score modules.It was significantly better among the INFIX group than the EXFIX group in all three modules.At the final follow-up,both groups had no statistically significant difference according to the Majeed score;92.35 in the INFIX group and 90.99 in the EXFIX group(P=0.513).A lower surgical site infection rate was noticed in the INFIX group(P=0.007).CONCLUSION Anterior subcutaneous pelvis INFIX is associated with better radiological outcomes and a lower infection rate than anterior supra-acetabular EXFIX in managing patients with unstable anterior pelvic ring fractures. 展开更多
关键词 internal fixator External fixator UNSTABLE ANTERIOR PELVIC INJURIES
下载PDF
Clinical Effect of Posterior Internal Fixation and Fusion in the Treatment of Thoracolumbar Fractures 被引量:1
20
作者 Tianhui Liu Jianmin Cui 《Journal of Clinical and Nursing Research》 2021年第2期38-41,共4页
Objective:To evaluate the clinical effect of posterior internal fixation and fusion in the treatment of thoracolumbar fractures.Methods:36 patients with thoracolumbar fractures from January 2018 to December 2020 were ... Objective:To evaluate the clinical effect of posterior internal fixation and fusion in the treatment of thoracolumbar fractures.Methods:36 patients with thoracolumbar fractures from January 2018 to December 2020 were selected and divided into study group and control group according to the random number table model.The control group was treated with anterior internal fixation,while the study group was treated with posterior internal fixation and fusion.The indexes of the two groups were compared and analyzed.Results:Compared with the operation related indexes of the two groups,the study group had more advantages(P<0.05);The postoperative kyphosis Cobb angle,height of anterior and posterior vertebral body,wedge index of the two groups were better than those before operation(P<0.05),and there was no significant difference between the two groups(P>0.05);There was no significant difference between the two groups(P>0.05).Conclusion:The clinical effect of posterior internal fixation and fusion in the treatment of thoracolumbar fractures is significant,and the body damage is slight,which is worthy of comprehensive promotion. 展开更多
关键词 Thoracolumbar fracture of spine The back road internal fixation and fusion
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部