The operation of biomass treatment devices such as gasifiers is based on the control of key parameters that play an important role in product formation. These include: temperature, excess oxygen, relative humidity and...The operation of biomass treatment devices such as gasifiers is based on the control of key parameters that play an important role in product formation. These include: temperature, excess oxygen, relative humidity and biomass composition. This work focuses on excess oxygen and temperature. Unfortunately, flue gas oxygen analyzers are expensive and not accessible to small industries. However, the equivalence ratio is linked to excess oxygen and has the advantage of not depending on biomass composition. This study therefore focuses on the design and development of a device for controlling this equivalence ratio by measuring oxygen concentration using a self-propelled Lambda probe, and a system for monitoring this equivalence ratio using an Arduino Uno 3 microcontroller. The temperature is recorded with an accuracy of ±1.5°C. For a heating time of 10 minutes, the response time to temperature change is around 3 seconds, which is sufficient for the device to function properly. This simple device is an efficient and cost-effective means of checking the equivalence ratio.展开更多
Background: B-cell Acute lymphoblastic leukemia (B-ALL) is a neoplasm of lymphoblasts which are of B-cell lineage typically composed of small to medium sized blast cells, moderately condensed to dispersed chromatin wi...Background: B-cell Acute lymphoblastic leukemia (B-ALL) is a neoplasm of lymphoblasts which are of B-cell lineage typically composed of small to medium sized blast cells, moderately condensed to dispersed chromatin with scanty cytoplasm and inconspicuous nucleoli, involving the bone marrow and/or blood. Methods and materials: This is a prospective cross-sectional study in which 50 blood and/or bone marrow samples of newly diagnosed patients (B-ALL) were tested for immunophenotyping. All samples were prepared for surface and cytoplasmic markers including kappa and lambda human antibody for 10 minutes in dark place and then run by the Flow Cytometer. Results: 64% of the study populations were males and 36% were females. Cases were classified according to immunophenotype and the age into different subtypes and showed the following frequencies: Pro B-ALL (8%), early pre B-ALL (56%), common B-ALL (16%), Pre-B-ALL (14%) and Mature B-ALL (only 6%). Surface immunoglobulin was positive in 10% and negative in 90% of all patients, showing 100% positivity in mature B-ALL and totally negative in other subtypes. While cytoplasmic immunoglobulin was positive in 16% and negative in 84% of all patients and was positive in 100% of Pre-B-ALL and in 50% of mature B-ALL. Surface kappa was more expressed in mature B-ALL than lambda giving a ratio of 2:1, while cytoplasmic kappa:lambda was 6:1 in Pre-B-ALL. Conclusion: Kappa and lambda have important role in B-ALL classification which necessitates their presence in immunophenotyping of B-ALL.展开更多
文摘The operation of biomass treatment devices such as gasifiers is based on the control of key parameters that play an important role in product formation. These include: temperature, excess oxygen, relative humidity and biomass composition. This work focuses on excess oxygen and temperature. Unfortunately, flue gas oxygen analyzers are expensive and not accessible to small industries. However, the equivalence ratio is linked to excess oxygen and has the advantage of not depending on biomass composition. This study therefore focuses on the design and development of a device for controlling this equivalence ratio by measuring oxygen concentration using a self-propelled Lambda probe, and a system for monitoring this equivalence ratio using an Arduino Uno 3 microcontroller. The temperature is recorded with an accuracy of ±1.5°C. For a heating time of 10 minutes, the response time to temperature change is around 3 seconds, which is sufficient for the device to function properly. This simple device is an efficient and cost-effective means of checking the equivalence ratio.
文摘Background: B-cell Acute lymphoblastic leukemia (B-ALL) is a neoplasm of lymphoblasts which are of B-cell lineage typically composed of small to medium sized blast cells, moderately condensed to dispersed chromatin with scanty cytoplasm and inconspicuous nucleoli, involving the bone marrow and/or blood. Methods and materials: This is a prospective cross-sectional study in which 50 blood and/or bone marrow samples of newly diagnosed patients (B-ALL) were tested for immunophenotyping. All samples were prepared for surface and cytoplasmic markers including kappa and lambda human antibody for 10 minutes in dark place and then run by the Flow Cytometer. Results: 64% of the study populations were males and 36% were females. Cases were classified according to immunophenotype and the age into different subtypes and showed the following frequencies: Pro B-ALL (8%), early pre B-ALL (56%), common B-ALL (16%), Pre-B-ALL (14%) and Mature B-ALL (only 6%). Surface immunoglobulin was positive in 10% and negative in 90% of all patients, showing 100% positivity in mature B-ALL and totally negative in other subtypes. While cytoplasmic immunoglobulin was positive in 16% and negative in 84% of all patients and was positive in 100% of Pre-B-ALL and in 50% of mature B-ALL. Surface kappa was more expressed in mature B-ALL than lambda giving a ratio of 2:1, while cytoplasmic kappa:lambda was 6:1 in Pre-B-ALL. Conclusion: Kappa and lambda have important role in B-ALL classification which necessitates their presence in immunophenotyping of B-ALL.