[Objectives]To determine active components of Lamiophlomis rotata(Benth.)Kudo.[Methods]A new method was developed for the quantitative determination of L.rotata by using Ultra-performance convergence chromatography.Th...[Objectives]To determine active components of Lamiophlomis rotata(Benth.)Kudo.[Methods]A new method was developed for the quantitative determination of L.rotata by using Ultra-performance convergence chromatography.The separation of active components of L.rotata was successfully achieved on Waters ACQUITY UPC column,with gradient elution carbon dioxide and methanol solvent at flow rate of 0.7 mL/min.The separation gradient elution rate was as follows:15%methanol 0-1 min,18%methanol 1-5 min,20%methanol 5-6 min,25%methanol 6-7 min,30%methanol 7-8 min,30%methanol 8-9 min,15%methanol 9-10 min.The conditions used in the separation process was as follows:column temperature 30℃;injection volume 2μL.Under the abovementioned conditions,the content of methyl glucoside was measured by 3D-full wavelength scanning.The validity of the method was tested by analyzing the precision,reproducibility,stability and accuracy.[Results]The results indicated that in terms of extraction and separation of compounds,supercritical CO2 not only has the diffusion property of gas,but also has the density and fluidity of liquid.[Conclusions]The ultra-high performance chromatography is a new technique for drug analysis.展开更多
基金Collaborative Innovation in Tibetan Medicine(2019XTC013)Open Laboratory of Key Laboratory of Tibetan Medicine Basic Education(ZYYJC-19-01).
文摘[Objectives]To determine active components of Lamiophlomis rotata(Benth.)Kudo.[Methods]A new method was developed for the quantitative determination of L.rotata by using Ultra-performance convergence chromatography.The separation of active components of L.rotata was successfully achieved on Waters ACQUITY UPC column,with gradient elution carbon dioxide and methanol solvent at flow rate of 0.7 mL/min.The separation gradient elution rate was as follows:15%methanol 0-1 min,18%methanol 1-5 min,20%methanol 5-6 min,25%methanol 6-7 min,30%methanol 7-8 min,30%methanol 8-9 min,15%methanol 9-10 min.The conditions used in the separation process was as follows:column temperature 30℃;injection volume 2μL.Under the abovementioned conditions,the content of methyl glucoside was measured by 3D-full wavelength scanning.The validity of the method was tested by analyzing the precision,reproducibility,stability and accuracy.[Results]The results indicated that in terms of extraction and separation of compounds,supercritical CO2 not only has the diffusion property of gas,but also has the density and fluidity of liquid.[Conclusions]The ultra-high performance chromatography is a new technique for drug analysis.