Magnesium(Mg)alloys are considered to be a new generation of revolutionary medical metals.Laser-beam powder bed fusion(PBF-LB)is suitable for fabricating metal implants withpersonalized and complicated structures.Howe...Magnesium(Mg)alloys are considered to be a new generation of revolutionary medical metals.Laser-beam powder bed fusion(PBF-LB)is suitable for fabricating metal implants withpersonalized and complicated structures.However,the as-built part usually exhibits undesirable microstructure and unsatisfactory performance.In this work,WE43 parts were firstly fabricated by PBF-LB and then subjected to heat treatment.Although a high densification rate of 99.91%was achieved using suitable processes,the as-built parts exhibited anisotropic and layeredmicrostructure with heterogeneously precipitated Nd-rich intermetallic.After heat treatment,fine and nano-scaled Mg24Y5particles were precipitated.Meanwhile,theα-Mg grainsunderwent recrystallization and turned coarsened slightly,which effectively weakened thetexture intensity and reduced the anisotropy.As a consequence,the yield strength and ultimate tensile strength were significantly improved to(250.2±3.5)MPa and(312±3.7)MPa,respectively,while the elongation was still maintained at a high level of 15.2%.Furthermore,the homogenized microstructure reduced the tendency of localized corrosion and favoredthe development of uniform passivation film.Thus,the degradation rate of WE43 parts was decreased by an order of magnitude.Besides,in-vitro cell experiments proved their favorable biocompatibility.展开更多
The DLBSW( dual laser-beam bilateral synchronous welding) technology of T-type joint has been widely used for the connection of skins and stringers in airplane industry. To understand the thermodynamic and mechanica...The DLBSW( dual laser-beam bilateral synchronous welding) technology of T-type joint has been widely used for the connection of skins and stringers in airplane industry. To understand the thermodynamic and mechanical behavior of this process, it is necessary to establish a reasonable heat source model. Two different surface-body combination heat source models are adopted in this paper. Both models use the Gaussian surface heat source model and one is combined with the cone body heat source model and the other is combined with Gaussian rotator body heat source model. The simulation results of these two different models are investigated. And the temperature field results of DLBSW process for T-joint with two different heat sources are discussed. It is indicated that the combination heat source model is effective to simulate the DLBSW process and the current study is useful for more profound research in this field.展开更多
According to the vectorial structure of non-paraxial electromagnetic beams and the method of stationary phase, the analytical TE and TM terms of non-paraxial linearly polarized Caussian beam are presented in the far f...According to the vectorial structure of non-paraxial electromagnetic beams and the method of stationary phase, the analytical TE and TM terms of non-paraxial linearly polarized Caussian beam are presented in the far field. The influence of linearly polarized angle on the relative energy flux distributions of the whole beam and its TE and TM terms is studied. The beam spot of the TE term is perpendicular to the direction of linearly polarized angle, while that of the TM term coincides with the direction of linearly polarized angle. The whole beam spot is elliptical, and the long axis is located at the direction of linearly polarized angle. The relative energy flux distribution of the TE term is relatively centralized in the direction perpendicular to the linearly polarized angle. While that of the TM term is relatively centralized in the direction of linearly polarized angle. To obtain the isolated TM and TE terms, a polarizer should be put at the long and the short axis of the whole beam spot, respectively.展开更多
A new scheme of small compact optical frequency standard based on thermal calcium beam with application of 423 nm shelving detection and sharp-angle velocity selection detection is proposed. Combining these presented ...A new scheme of small compact optical frequency standard based on thermal calcium beam with application of 423 nm shelving detection and sharp-angle velocity selection detection is proposed. Combining these presented techniques, we conclude that a small compact optical frequency standard based on thermal calcium beam will outperform the commercial caesium-beam microwave dock, like the 5071 Cs clock (from Hp to Agilent, now Symmetricom company), both in accuracy and stability.展开更多
基金supported by the following funds:National Natural Science Foundation of China(51935014,52165043)Jiangxi Provincial Cultivation Program for Academic and Technical Leaders of Major Subjects(20225BCJ23008)+1 种基金Jiangxi Provincial Natural Science Foundation(20224ACB204013,20224ACB214008)Scientific Research Project of Anhui Universities(KJ2021A1106)。
文摘Magnesium(Mg)alloys are considered to be a new generation of revolutionary medical metals.Laser-beam powder bed fusion(PBF-LB)is suitable for fabricating metal implants withpersonalized and complicated structures.However,the as-built part usually exhibits undesirable microstructure and unsatisfactory performance.In this work,WE43 parts were firstly fabricated by PBF-LB and then subjected to heat treatment.Although a high densification rate of 99.91%was achieved using suitable processes,the as-built parts exhibited anisotropic and layeredmicrostructure with heterogeneously precipitated Nd-rich intermetallic.After heat treatment,fine and nano-scaled Mg24Y5particles were precipitated.Meanwhile,theα-Mg grainsunderwent recrystallization and turned coarsened slightly,which effectively weakened thetexture intensity and reduced the anisotropy.As a consequence,the yield strength and ultimate tensile strength were significantly improved to(250.2±3.5)MPa and(312±3.7)MPa,respectively,while the elongation was still maintained at a high level of 15.2%.Furthermore,the homogenized microstructure reduced the tendency of localized corrosion and favoredthe development of uniform passivation film.Thus,the degradation rate of WE43 parts was decreased by an order of magnitude.Besides,in-vitro cell experiments proved their favorable biocompatibility.
基金The research is sponsored by the Shanghai STCSM Project of the Postdoctoral Science Research Assistant Plan (10R21421200), the National Natural Science Foundation of China (50904038) and the China Postdoctoral Science Foundation (20100470064).
文摘The DLBSW( dual laser-beam bilateral synchronous welding) technology of T-type joint has been widely used for the connection of skins and stringers in airplane industry. To understand the thermodynamic and mechanical behavior of this process, it is necessary to establish a reasonable heat source model. Two different surface-body combination heat source models are adopted in this paper. Both models use the Gaussian surface heat source model and one is combined with the cone body heat source model and the other is combined with Gaussian rotator body heat source model. The simulation results of these two different models are investigated. And the temperature field results of DLBSW process for T-joint with two different heat sources are discussed. It is indicated that the combination heat source model is effective to simulate the DLBSW process and the current study is useful for more profound research in this field.
文摘According to the vectorial structure of non-paraxial electromagnetic beams and the method of stationary phase, the analytical TE and TM terms of non-paraxial linearly polarized Caussian beam are presented in the far field. The influence of linearly polarized angle on the relative energy flux distributions of the whole beam and its TE and TM terms is studied. The beam spot of the TE term is perpendicular to the direction of linearly polarized angle, while that of the TM term coincides with the direction of linearly polarized angle. The whole beam spot is elliptical, and the long axis is located at the direction of linearly polarized angle. The relative energy flux distribution of the TE term is relatively centralized in the direction perpendicular to the linearly polarized angle. While that of the TM term is relatively centralized in the direction of linearly polarized angle. To obtain the isolated TM and TE terms, a polarizer should be put at the long and the short axis of the whole beam spot, respectively.
基金Supported by the National Key Basic Research and Development Programme of China under Grant No 2005CB724500, and the National Natural Science Foundation of China under Grant Nos 60178016 and 10104002.
文摘A new scheme of small compact optical frequency standard based on thermal calcium beam with application of 423 nm shelving detection and sharp-angle velocity selection detection is proposed. Combining these presented techniques, we conclude that a small compact optical frequency standard based on thermal calcium beam will outperform the commercial caesium-beam microwave dock, like the 5071 Cs clock (from Hp to Agilent, now Symmetricom company), both in accuracy and stability.