AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ...AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.展开更多
A compound varifocal lens based on electromagnetic drive technology is designed and fabricated, where the polydimethylsiloxane(PDMS) film acts as a driving component, while the PDMS biconvex lens and the plane-concave...A compound varifocal lens based on electromagnetic drive technology is designed and fabricated, where the polydimethylsiloxane(PDMS) film acts as a driving component, while the PDMS biconvex lens and the plane-concave lens form a coaxial compound lens system. The plane-concave lens equipped with driving coils is installed directly above the PDMS lens surrounded by the annular magnet. When different currents are applied, the annular magnet moves up and down, driving the PDMS film to undergo elastic deformation, and then resulting in longitudinal movement of the PDMS lens. The position change of the PDMS lens changes the focal length of the compound lens system. To verify the feasibility and practicability of this design, a prototype of our compound lens system is fabricated in experiment. Our proposed compound lens shows that its zoom ability reaches 9.28 mm when the current ranges from -0.20 A to 0.21 A.展开更多
AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defoc...AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.展开更多
●AIM:To evaluate the effectiveness and safety of early lens extraction during pars plana vitrectomy(PPV)for proliferative diabetic retinopathy(PDR)compared to those of PPV with subsequent cataract surgery.●METHODS:T...●AIM:To evaluate the effectiveness and safety of early lens extraction during pars plana vitrectomy(PPV)for proliferative diabetic retinopathy(PDR)compared to those of PPV with subsequent cataract surgery.●METHODS:This multicenter randomized controlled trial was conducted in three Chinese hospitals on patients with PDR,aged>45y,with mild cataracts.The participants were randomly assigned to the combined(PPV combined with simultaneously cataract surgery,i.e.,phacovitrectomy)or subsequent(PPV with subsequent cataract surgery 6mo later)group and followed up for 12mo.The primary outcome was the change in best-corrected visual acuity(BCVA)from baseline to 6mo,and the secondary outcomes included complication rates and medical expenses.●RESULTS:In total,129 patients with PDR were recruited and equally randomized(66 and 63 in the combined and subsequent groups respectively).The change in BCVA in the combined group[mean,36.90 letters;95%confidence interval(CI),30.35–43.45]was significantly better(adjusted difference,16.43;95%CI,8.77–24.08;P<0.001)than in the subsequent group(mean,22.40 letters;95%CI,15.55–29.24)6mo after the PPV,with no significant difference between the two groups at 12mo.The overall surgical risk of two sequential surgeries was significantly higher than that of the combined surgery for neovascular glaucoma(17.65%vs 3.77%,P=0.005).No significant differences were found in the photocoagulation spots,surgical time,and economic expenses between two groups.In the subsequent group,the duration of work incapacity(22.54±9.11d)was significantly longer(P<0.001)than that of the combined group(12.44±6.48d).●CONCLUSION:PDR patients aged over 45y with mild cataract can also benefit from early lens extraction during PPV with gratifying effectiveness,safety and convenience,compared to sequential surgeries.展开更多
●AIM:To explore whether autophagy functions as a cellular adaptation mechanism in lens epithelial cells(LECs)under hyperosmotic stress.●METHODS:LECs were treated with hyperosmotic stress at the concentration of 270,...●AIM:To explore whether autophagy functions as a cellular adaptation mechanism in lens epithelial cells(LECs)under hyperosmotic stress.●METHODS:LECs were treated with hyperosmotic stress at the concentration of 270,300,400,500,or 600 mOsm for 6,12,18,24h in vitro.Polymerase chain reaction(PCR)was employed for the mRNA expression of autophagyrelated genes,while Western blotting detected the targeted protein expression.The transfection of stub-RFP-sens-GFPLC3 autophagy-related double fluorescence lentivirus was conducted to detect the level of autophagy flux.Scanning electron microscopy was used to detect the existence of autolysosome.Short interfering RNA of autophagy-related gene(ATG)7,transient receptor potential vanilloid(TRPV)1 overexpression plasmid,related agonists and inhibitors were employed to their influence on autophagy related pathway.Flow cytometry was employed to test the apoptosis and intracellular Ca^(2+)level.Mitochondrial membrane potential was measured by JC-1 staining.The cell counting kit-8 assay was used to calculate the cellular viability.The wound healing assay was used to evaluate the wound closure rate.GraphPad 6.0 software was utilized to evaluate the data.●RESULTS:The hyperosmotic stress activated autophagy in a pressure-and time-dependent manner in LECs.Beclin 1 protein expression and conversion of LC3B II to LC3B I increased,whereas sequestosome-1(SQSTM1)protein expression decreased.Transient Ca^(2+)influx was stimulated caused by hyperosmotic stress,levels of mammalian target of rapamycin(mTOR)phosphorylation decreased,and the level of AMP-activated protein kinase(AMPK)phosphorylation increased in the early stage.Based on this evidence,autophagy activation through the Ca^(2+)-dependent AMPK/mTOR pathway might represent an adaptation process in LECs under hyperosmotic stress.Hyperosmotic stress decreased cellular viability and accelerated apoptosis in LECs and cellular migration decreased.Inhibition of autophagy by ATG7 knockdown had similar results.TRPV1 overexpression increased autophagy and might be crucial in the occurrence of autophagy promoted by hyperosmotic stress.●CONCLUSION:A combination of hyperosmotic stress and autophagy inhibition may be a promising approach to decrease the number of LECs in the capsular bag and pave the way for improving prevention of posterior capsular opacification and capsular fibrosis.展开更多
The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract sur...The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.展开更多
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv...AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes.展开更多
AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectiv...AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique.展开更多
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W...AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group.展开更多
AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.M...AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.METHODS:The study is a retrospective,case-series study.Totally 301 eyes of 301 patients undergoing combined PPV/SOR with cataract surgery were enrolled.Eligible individuals were separated into four groups according to their preoperative diagnoses:silicone oil-filled eyes after PPV(group 1),epiretinal membrane(group 2),macular hole(group 3),and primary retinal detachment(RD;group 4).The variables af fecting postoperative refractive outcomes were analyzed,including age,gender,preoperative best-corrected visual acuity(BCVA),axial length(AL),keratometry average,anterior chamber depth(ACD),intraocular tamponade,and vitreoretinal pathology.The outcome measurements include the mean refractive PE and the proportions of eyes with a PE within±0.50 diopter(D)and±1.00 D.RESULTS:For all patients,the mean PE was-0.04±1.17 D,and 50.17%of patients(eyes)had a PE within±0.50 D.There was a significant difference in refractive outcomes among the four groups(P=0.028),with RD(group 4)showing the least favorable refractive outcome.In multivariate regression analysis,only AL,vitreoretinal pathology,and ACD were strongly associated with PE(all P<0.01).Univariate analysis revealed that longer eyes(AL>26 mm)and a deeper ACD were correlated with hyperopic PE,and shorter eyes(AL<26 mm)and a shallower ACD were correlated with myopic PE.CONCLUSION:RD patients have the least favorable refractive outcome.AL,vitreoretinal pathology,and ACD are strongly associated with PE in the combined surgery.These three factors affect refractive outcomes and thus can be used to predict a better postoperative refractive outcome in clinical practice.展开更多
AIM:To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device(OVD).METHODS:Two patients who dev...AIM:To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device(OVD).METHODS:Two patients who developed transient lens vacuolar changes during uneventful persistent pupillary membrane(PPM)removal surgery were presented and followed up.This event was speculated to be associated with an intraoperative dispersive OVD DisCoVisc(hyaluronic acid 1.6%-chondroitin sulfate 4.0%)exposure.Then,to provide the pathological basis for our speculation,another four cataract patients were randomly exposed to different OVDs,and their anterior lens capsules were investigated with transmission electron microscopy(TEM).RESULTS:After months,the subcapsular vacuoles in both PPM cases were gradually disappeared without visual deterioration.For the cataract patients,similar lens changes were observed intraoperatively in those exposed to a dispersive DisCoVisc but not a cohesive OVD IVIZ(sodium hyaluronate gel 1.0%).In addition,marked ultrastructural changes,including chromatin condensation,extensive cytoplasmic vacuoles,and obvious intercellular space between lens epithelial cells in the anterior lens capsules of all eyes exposed to DisCoVisc,were observed by TEM.CONCLUSION:The lens vacuolar changes may be associated with a dispersive OVD exposure.Therefore,it is not preferable to use dispersive OVDs in patients with transparent lenses or without the intention of lens extraction.In addition,close follow-ups instead of immediate lens extraction are recommended for the occurrence of similar lens lesions.展开更多
AIM:To investigate the effect of Cionni-modified capsular tension ring(CTR)implantation in patients with severely traumatic subluxated cataracts.METHODS:All patients who totally had traumatic cataracts and lost zonule...AIM:To investigate the effect of Cionni-modified capsular tension ring(CTR)implantation in patients with severely traumatic subluxated cataracts.METHODS:All patients who totally had traumatic cataracts and lost zonule support and underwent cataract surgery were retrospectively analyzed.Corrected distance visual acuity(CDVA),extent of zonulysis,intraocular lens(IOL)position,intraoperative presentation,and complications were assessed.The primary outcomes included IOL centration stability and other postoperative complications.RESULTS:Twenty patients(20 eyes)were included in this study.The mean age in this study was 58.0±11.3y,and the average follow-up time was 17.3±12.8mo.Capsule bags were saved by Cionni-modified CTR.Nine eyes(45%)underwent simultaneously anterior vitrectomy due to the presence of vitreous in the anterior chamber.The preoperative mean CDVA was 0.83±0.24 log MAR,and the postoperative average CDVA was 0.23±0.30 log MAR(P<0.05).The horizontal and vertical IOL decentration after surgery was 0.27±0.12 mm and 0.41±0.19 mm,respectively;the vertical and horizontal IOL tilt after surgery was 5.5°±2.5°and 6.1°±2.2°,respectively.None of the eyes had obvious IOL decentration during the follow-up time.Eight eyes(40%)had posterior capsule opacification(PCO)that was severe enough to cause poor vision.Neodymium:YAG laser capsulotomy were performed on these eyes when the CTR was stabilized.CONCLUSION:With the help of Cionni-modified CTR,capsular bag preservation and better IOL concentration can be achieved without major complications in patients with severely traumatic subluxated cataracts.展开更多
Meta-lens are a new type of planar optical element that can flexibly manipulate the phase, polarization and amplitude of the beam, and are currently receiving a great deal of attention as they are easier to process an...Meta-lens are a new type of planar optical element that can flexibly manipulate the phase, polarization and amplitude of the beam, and are currently receiving a great deal of attention as they are easier to process and manufacture. Off-axis meta-lens are a special type of meta-lens with a certain degree of dispersion that can be used as a beam-splitting element, providing a unique and feasible way to realize micro-miniature instruments. We analyze the effects of different numerical apertures and off-axis angles on the spectral resolution, focusing efficiency and simulation results of off-axis meta-lens to provide ideas for subsequent research and application of off-axis meta-lens. A number of off-axis meta-lens with parameters NA = 0.408 α = 13°, NA = 0.18 α = 13°<sup></sup> and NA = 0.408 α = 20° were simulated through Lumerical software. The results show that the off-axis angle is related to the resolution;the larger the angle, the better the spectral resolution but the lower the focusing efficiency;when the numerical aperture is smaller, the smaller the coverage of the phase distribution, which will lead to a larger deviation between simulation and theory. The designer needs to balance the numerical aperture, off-axis angle and other parameters reasonably according to the requirements in order to achieve the desired effect. The findings of this study have important reference values for the theoretical analysis of off-axis meta-lens and the design of parameters in practical applications. .展开更多
AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted...AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery.展开更多
AIM:To determine whether an antisense RNA corresponding to the human Alu transposable element(Aluas RNA)can protect human lens epithelial cells(HLECs)from methylglyoxal-induced apoptosis.METHODS:Cell counting kit-8(CC...AIM:To determine whether an antisense RNA corresponding to the human Alu transposable element(Aluas RNA)can protect human lens epithelial cells(HLECs)from methylglyoxal-induced apoptosis.METHODS:Cell counting kit-8(CCK-8)and 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide(MTT)assays were used to assess HLEC viability.HLEC viability/death was detected using a Calcein-AM/PI double staining kit;the annexin V-FITC method was used to detect HLEC apoptosis.The cytosolic reactive oxygen species(ROS)levels in HLECs were determined using a reactive species assay kit.The levels of malondialdehyde(MDA)and the antioxidant activities of total-superoxide dismutase(T-SOD)and glutathione peroxidase(GSH-Px)were assessed in HLECs using their respective kits.RT-q PCR and Western blotting were used to measure m RNA and protein expression levels of the genes.RESULTS:Aluas RNA rescued methylglyoxal-induced apoptosis in HLECs and ameliorated both the methylglyoxalinduced decrease in Bcl-2 m RNA and the methylglyoxalinduced increase in Bax m RNA.In addition,Aluas RNA inhibited the methylglyoxal-induced increase in Alu sense RNA expression.Aluas RNA inhibited the production of ROS induced by methylglyoxal,restored T-SOD and GSHPx activity,and moderated the increase in MDA content after treatment with methylglyoxal.Aluas RNA significantly restored the methylglyoxal-induced down-regulation of Nrf2 gene and antioxidant defense genes,including glutathione peroxidase,heme oxygenase 1,γ-glutamylcysteine synthetase and quinone oxidoreductase 1.Aluas RNA ameliorated methylglyoxal-induced increases of the m RNA and protein expression of Keap1 that is the negative regulator of Nrf2.CONCLUSION:Aluas RNA reduces apoptosis induced by methylglyoxal by enhancing antioxidant defense.展开更多
AIM:To compare the surgical outcomes of a multifocal intraocular lens(IOL;Lentis Comfort LS-313 MF15)with those of an enhanced monofocal IOL(Tecnis Eyhance DIB00V).METHODS:This retrospective study included patients wh...AIM:To compare the surgical outcomes of a multifocal intraocular lens(IOL;Lentis Comfort LS-313 MF15)with those of an enhanced monofocal IOL(Tecnis Eyhance DIB00V).METHODS:This retrospective study included patients who underwent cataract surgery with LS-313 MF15 or Eyhance IOL implantation.Data regarding patient demographics,surgical records,and ophthalmic examination before the cataract surgery and one and three months postoperatively were collected.Visual acuities,refractive values,defocus curves,contrast sensitivities and subjective symptoms were evaluated.RESULTS:Among the 71 eyes(47 patients)included in this study,32 eyes(20 patients)underwent LS-313 MF15 IOL implantation,and 39 eyes(27 patients)underwent Eyhance IOL implantation.No significant differences were observed in age,axial length,or refractive error between the two groups preoperatively.Furthermore,the distancecorrected and uncorrected distance visual acuities one month postoperatively did not differ between the groups,and both groups had sufficient visual acuities at the distances of 5,1 m,70,50,and 30 cm.Other ophthalmic data,including subjective symptoms based on the 14-item Visual Function Index Questionnaire,monocular defocus curves,contrast sensitivities,and halo and glare,did not differ between the groups three months postoperatively.Moreover,both groups had good outcomes.The spherical equivalent one month postoperatively was significantly myopic in the LS-313 MF15 group compared with that in the Eyhance group(P=0.033);however,this difference was not observed three months postoperatively(P=0.471).CONCLUSION:Comparison of the surgical outcomes of LS-313 MF15 with those of Eyhance with different optical properties reveal that both IOLs show good postoperative outcomes,with no significant differences being noted between the two IOLs.展开更多
The calculation of frost heaving with ice lens formation is still not standard for construction projects using artificial ground freezing(AGF).In fine-grained material,ice lenses may initiate and lead to significant h...The calculation of frost heaving with ice lens formation is still not standard for construction projects using artificial ground freezing(AGF).In fine-grained material,ice lenses may initiate and lead to significant heaving at the ground surface,which should be considered in advance.However,the complex processes during ice lens formation are still not fully understood and difficult to capture in a simple approach.In the past,the semi-analytical approach of Konrad and Morgenstern used one soil constant,the“segregation potential(SP)”.It has been mainly and most successfully applied to the heave calculation of natural-induced soil freezing in cold regions.Its application to AGF has been so far unsuccessful.To solve this,a new semi-analytical approach is presented in this paper.It includes AGF conditions such as bottom-up freezing,temperature gradients to reach great freezing velocities,and a distinction between two freezing states.One is the freezing-up state until a certain frost body thickness is reached(thermal transient state),and the other is a holding phase where the frost body thickness is kept constant(thermal quasi-steady state).To test its ability,the results are applied to another freezing direction,the top-down freezing.The new approach is validated using two different frost-susceptible soils and,in total,50 frost heave tests.In the thermal transient region,where the SP is applicable,the two semi-analytical approaches are compared,showing improved performance of the current method by about 15%.展开更多
AIM: To examine the protection of ferulic acid(FA) against ionizing radiation(IR)-induced lens injury in rats, as well as the underlying mechanisms.METHODS: FA(50 mg/kg) was administered to rats for 4 consecutive days...AIM: To examine the protection of ferulic acid(FA) against ionizing radiation(IR)-induced lens injury in rats, as well as the underlying mechanisms.METHODS: FA(50 mg/kg) was administered to rats for 4 consecutive days before they were given 10 Gy γ-radiation, as well as for 3 consecutive days afterward. Two weeks after radiation, the eye tissues were collected. Histological alterations were evaluated by hematoxylineosin staining. Enzyme linked immunosorbent assay(ELISA) was utilized to assess the activities of glutathione reductase(GR) and superoxide dismutase(SOD), as well as the levels of glutathione(GSH) and malondialdehyde(MDA) in the lenses. The protein and m RNA levels of Bcl-2, caspase-3, Bax, heme oxygenase-1(HO-1), and glutamatecysteine ligase catalytic subunit(GCLC) were quantified using Western blot and quantitative reverse transcription polymerase chain reaction, respectively. With nuclear extracts, the nuclear factor erythroid-2 related factor(Nrf2) protein expressions in the nuclei were also measured.RESULTS: Rats exposed to IR showed lens histological alterations which could be alleviated by FA. FA treatment reversed apoptosis-related markers in IR-induced lens, as evidenced by lower levels of Bax and caspase-3 and higher level of Bcl-2. Furthermore, IR induced oxidative damage manifested by decreased GSH level, increased MDA level, and decreased SOD and GR activities. FA boosted nuclear translocation of Nrf2 and increased the expressions of HO-1 and GCLC to inhibit oxidative stress, as evidenced by an increase in GSH, a decrease in MDA, and an increase in GR and SOD activities.CONCLUSION: FA may work well in preventing and treating IR-induced cataract through promoting the Nrf2 signal pathway to attenuate oxidative damage and cell apoptosis.展开更多
文摘AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications.
文摘A compound varifocal lens based on electromagnetic drive technology is designed and fabricated, where the polydimethylsiloxane(PDMS) film acts as a driving component, while the PDMS biconvex lens and the plane-concave lens form a coaxial compound lens system. The plane-concave lens equipped with driving coils is installed directly above the PDMS lens surrounded by the annular magnet. When different currents are applied, the annular magnet moves up and down, driving the PDMS film to undergo elastic deformation, and then resulting in longitudinal movement of the PDMS lens. The position change of the PDMS lens changes the focal length of the compound lens system. To verify the feasibility and practicability of this design, a prototype of our compound lens system is fabricated in experiment. Our proposed compound lens shows that its zoom ability reaches 9.28 mm when the current ranges from -0.20 A to 0.21 A.
基金the Deputyship for Research and Innovation,Ministry of Education in Saudi Arabia for funding this research work through the project(No.IFKSUOR3-433-1)。
文摘AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.
文摘●AIM:To evaluate the effectiveness and safety of early lens extraction during pars plana vitrectomy(PPV)for proliferative diabetic retinopathy(PDR)compared to those of PPV with subsequent cataract surgery.●METHODS:This multicenter randomized controlled trial was conducted in three Chinese hospitals on patients with PDR,aged>45y,with mild cataracts.The participants were randomly assigned to the combined(PPV combined with simultaneously cataract surgery,i.e.,phacovitrectomy)or subsequent(PPV with subsequent cataract surgery 6mo later)group and followed up for 12mo.The primary outcome was the change in best-corrected visual acuity(BCVA)from baseline to 6mo,and the secondary outcomes included complication rates and medical expenses.●RESULTS:In total,129 patients with PDR were recruited and equally randomized(66 and 63 in the combined and subsequent groups respectively).The change in BCVA in the combined group[mean,36.90 letters;95%confidence interval(CI),30.35–43.45]was significantly better(adjusted difference,16.43;95%CI,8.77–24.08;P<0.001)than in the subsequent group(mean,22.40 letters;95%CI,15.55–29.24)6mo after the PPV,with no significant difference between the two groups at 12mo.The overall surgical risk of two sequential surgeries was significantly higher than that of the combined surgery for neovascular glaucoma(17.65%vs 3.77%,P=0.005).No significant differences were found in the photocoagulation spots,surgical time,and economic expenses between two groups.In the subsequent group,the duration of work incapacity(22.54±9.11d)was significantly longer(P<0.001)than that of the combined group(12.44±6.48d).●CONCLUSION:PDR patients aged over 45y with mild cataract can also benefit from early lens extraction during PPV with gratifying effectiveness,safety and convenience,compared to sequential surgeries.
文摘●AIM:To explore whether autophagy functions as a cellular adaptation mechanism in lens epithelial cells(LECs)under hyperosmotic stress.●METHODS:LECs were treated with hyperosmotic stress at the concentration of 270,300,400,500,or 600 mOsm for 6,12,18,24h in vitro.Polymerase chain reaction(PCR)was employed for the mRNA expression of autophagyrelated genes,while Western blotting detected the targeted protein expression.The transfection of stub-RFP-sens-GFPLC3 autophagy-related double fluorescence lentivirus was conducted to detect the level of autophagy flux.Scanning electron microscopy was used to detect the existence of autolysosome.Short interfering RNA of autophagy-related gene(ATG)7,transient receptor potential vanilloid(TRPV)1 overexpression plasmid,related agonists and inhibitors were employed to their influence on autophagy related pathway.Flow cytometry was employed to test the apoptosis and intracellular Ca^(2+)level.Mitochondrial membrane potential was measured by JC-1 staining.The cell counting kit-8 assay was used to calculate the cellular viability.The wound healing assay was used to evaluate the wound closure rate.GraphPad 6.0 software was utilized to evaluate the data.●RESULTS:The hyperosmotic stress activated autophagy in a pressure-and time-dependent manner in LECs.Beclin 1 protein expression and conversion of LC3B II to LC3B I increased,whereas sequestosome-1(SQSTM1)protein expression decreased.Transient Ca^(2+)influx was stimulated caused by hyperosmotic stress,levels of mammalian target of rapamycin(mTOR)phosphorylation decreased,and the level of AMP-activated protein kinase(AMPK)phosphorylation increased in the early stage.Based on this evidence,autophagy activation through the Ca^(2+)-dependent AMPK/mTOR pathway might represent an adaptation process in LECs under hyperosmotic stress.Hyperosmotic stress decreased cellular viability and accelerated apoptosis in LECs and cellular migration decreased.Inhibition of autophagy by ATG7 knockdown had similar results.TRPV1 overexpression increased autophagy and might be crucial in the occurrence of autophagy promoted by hyperosmotic stress.●CONCLUSION:A combination of hyperosmotic stress and autophagy inhibition may be a promising approach to decrease the number of LECs in the capsular bag and pave the way for improving prevention of posterior capsular opacification and capsular fibrosis.
文摘The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population.
基金Supported by the Fundamental Research Funds of the State Key Laboratory of Ophthalmology(No.303060202400201203).
文摘AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes.
基金Supported by the Gongli Hospital of Pudong New Area,Shanghai(No.2017YQNJJ-13)。
文摘AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique.
基金Supported by National Natural Science Foundation of China(No.82070937,No.81870640)National Science Foundation for Young Scientists of China(No.82101097)。
文摘AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group.
基金Supported by the National Natural Science Foundation of China (No.81770972,No.81970843)。
文摘AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.METHODS:The study is a retrospective,case-series study.Totally 301 eyes of 301 patients undergoing combined PPV/SOR with cataract surgery were enrolled.Eligible individuals were separated into four groups according to their preoperative diagnoses:silicone oil-filled eyes after PPV(group 1),epiretinal membrane(group 2),macular hole(group 3),and primary retinal detachment(RD;group 4).The variables af fecting postoperative refractive outcomes were analyzed,including age,gender,preoperative best-corrected visual acuity(BCVA),axial length(AL),keratometry average,anterior chamber depth(ACD),intraocular tamponade,and vitreoretinal pathology.The outcome measurements include the mean refractive PE and the proportions of eyes with a PE within±0.50 diopter(D)and±1.00 D.RESULTS:For all patients,the mean PE was-0.04±1.17 D,and 50.17%of patients(eyes)had a PE within±0.50 D.There was a significant difference in refractive outcomes among the four groups(P=0.028),with RD(group 4)showing the least favorable refractive outcome.In multivariate regression analysis,only AL,vitreoretinal pathology,and ACD were strongly associated with PE(all P<0.01).Univariate analysis revealed that longer eyes(AL>26 mm)and a deeper ACD were correlated with hyperopic PE,and shorter eyes(AL<26 mm)and a shallower ACD were correlated with myopic PE.CONCLUSION:RD patients have the least favorable refractive outcome.AL,vitreoretinal pathology,and ACD are strongly associated with PE in the combined surgery.These three factors affect refractive outcomes and thus can be used to predict a better postoperative refractive outcome in clinical practice.
基金Supported by the National Key R&D Program of China(No.2020YFC2008200)the National Natural Science Foundation of China(No.81970778,No.82271066,No.81970813)+1 种基金the Natural Science Foundation of Guangdong Province(No.2023A1515011198)Guangzhou Municipal Science and Technology Project(No.SL2022A03J00553).
文摘AIM:To report the clinical prognosis and pathological findings of accidental lens vacuolar changes in eyes with intraoperative exposure to a dispersive ophthalmic viscosurgical device(OVD).METHODS:Two patients who developed transient lens vacuolar changes during uneventful persistent pupillary membrane(PPM)removal surgery were presented and followed up.This event was speculated to be associated with an intraoperative dispersive OVD DisCoVisc(hyaluronic acid 1.6%-chondroitin sulfate 4.0%)exposure.Then,to provide the pathological basis for our speculation,another four cataract patients were randomly exposed to different OVDs,and their anterior lens capsules were investigated with transmission electron microscopy(TEM).RESULTS:After months,the subcapsular vacuoles in both PPM cases were gradually disappeared without visual deterioration.For the cataract patients,similar lens changes were observed intraoperatively in those exposed to a dispersive DisCoVisc but not a cohesive OVD IVIZ(sodium hyaluronate gel 1.0%).In addition,marked ultrastructural changes,including chromatin condensation,extensive cytoplasmic vacuoles,and obvious intercellular space between lens epithelial cells in the anterior lens capsules of all eyes exposed to DisCoVisc,were observed by TEM.CONCLUSION:The lens vacuolar changes may be associated with a dispersive OVD exposure.Therefore,it is not preferable to use dispersive OVDs in patients with transparent lenses or without the intention of lens extraction.In addition,close follow-ups instead of immediate lens extraction are recommended for the occurrence of similar lens lesions.
基金Supported by the National Natural Science Foundation of China(No.82070968)China Postdoctoral Science Foundation(No.2022M712386)+4 种基金Tianjin Health Research Project(No.TJWJ2022MS040,No.ZC20166)Nankai University Eye Institute(No.NKYKK202203,No.NKYKK202206)Tianjin Eye Hospital Research Project(No.YKYB1902)Natural Science Foundation of Tianjin(No.20JCQNJC01860)Tianjin Key Medical Discipine(Specialty)Construction Project(No.TJYXZDXK-016A)。
文摘AIM:To investigate the effect of Cionni-modified capsular tension ring(CTR)implantation in patients with severely traumatic subluxated cataracts.METHODS:All patients who totally had traumatic cataracts and lost zonule support and underwent cataract surgery were retrospectively analyzed.Corrected distance visual acuity(CDVA),extent of zonulysis,intraocular lens(IOL)position,intraoperative presentation,and complications were assessed.The primary outcomes included IOL centration stability and other postoperative complications.RESULTS:Twenty patients(20 eyes)were included in this study.The mean age in this study was 58.0±11.3y,and the average follow-up time was 17.3±12.8mo.Capsule bags were saved by Cionni-modified CTR.Nine eyes(45%)underwent simultaneously anterior vitrectomy due to the presence of vitreous in the anterior chamber.The preoperative mean CDVA was 0.83±0.24 log MAR,and the postoperative average CDVA was 0.23±0.30 log MAR(P<0.05).The horizontal and vertical IOL decentration after surgery was 0.27±0.12 mm and 0.41±0.19 mm,respectively;the vertical and horizontal IOL tilt after surgery was 5.5°±2.5°and 6.1°±2.2°,respectively.None of the eyes had obvious IOL decentration during the follow-up time.Eight eyes(40%)had posterior capsule opacification(PCO)that was severe enough to cause poor vision.Neodymium:YAG laser capsulotomy were performed on these eyes when the CTR was stabilized.CONCLUSION:With the help of Cionni-modified CTR,capsular bag preservation and better IOL concentration can be achieved without major complications in patients with severely traumatic subluxated cataracts.
文摘Meta-lens are a new type of planar optical element that can flexibly manipulate the phase, polarization and amplitude of the beam, and are currently receiving a great deal of attention as they are easier to process and manufacture. Off-axis meta-lens are a special type of meta-lens with a certain degree of dispersion that can be used as a beam-splitting element, providing a unique and feasible way to realize micro-miniature instruments. We analyze the effects of different numerical apertures and off-axis angles on the spectral resolution, focusing efficiency and simulation results of off-axis meta-lens to provide ideas for subsequent research and application of off-axis meta-lens. A number of off-axis meta-lens with parameters NA = 0.408 α = 13°, NA = 0.18 α = 13°<sup></sup> and NA = 0.408 α = 20° were simulated through Lumerical software. The results show that the off-axis angle is related to the resolution;the larger the angle, the better the spectral resolution but the lower the focusing efficiency;when the numerical aperture is smaller, the smaller the coverage of the phase distribution, which will lead to a larger deviation between simulation and theory. The designer needs to balance the numerical aperture, off-axis angle and other parameters reasonably according to the requirements in order to achieve the desired effect. The findings of this study have important reference values for the theoretical analysis of off-axis meta-lens and the design of parameters in practical applications. .
基金Supported by the Science and Technology Innovation Program of Hunan Province,China(No.2020SK50103)Hunan Clinical Medical Technology Innovation Guiding Project in 2020。
文摘AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery.
基金Supported by the National Natural Science Foundation of China(No.81771499)the Natural Science Foundation of Hebei Province,China(No.H2018206099,No.H2021206460)。
文摘AIM:To determine whether an antisense RNA corresponding to the human Alu transposable element(Aluas RNA)can protect human lens epithelial cells(HLECs)from methylglyoxal-induced apoptosis.METHODS:Cell counting kit-8(CCK-8)and 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide(MTT)assays were used to assess HLEC viability.HLEC viability/death was detected using a Calcein-AM/PI double staining kit;the annexin V-FITC method was used to detect HLEC apoptosis.The cytosolic reactive oxygen species(ROS)levels in HLECs were determined using a reactive species assay kit.The levels of malondialdehyde(MDA)and the antioxidant activities of total-superoxide dismutase(T-SOD)and glutathione peroxidase(GSH-Px)were assessed in HLECs using their respective kits.RT-q PCR and Western blotting were used to measure m RNA and protein expression levels of the genes.RESULTS:Aluas RNA rescued methylglyoxal-induced apoptosis in HLECs and ameliorated both the methylglyoxalinduced decrease in Bcl-2 m RNA and the methylglyoxalinduced increase in Bax m RNA.In addition,Aluas RNA inhibited the methylglyoxal-induced increase in Alu sense RNA expression.Aluas RNA inhibited the production of ROS induced by methylglyoxal,restored T-SOD and GSHPx activity,and moderated the increase in MDA content after treatment with methylglyoxal.Aluas RNA significantly restored the methylglyoxal-induced down-regulation of Nrf2 gene and antioxidant defense genes,including glutathione peroxidase,heme oxygenase 1,γ-glutamylcysteine synthetase and quinone oxidoreductase 1.Aluas RNA ameliorated methylglyoxal-induced increases of the m RNA and protein expression of Keap1 that is the negative regulator of Nrf2.CONCLUSION:Aluas RNA reduces apoptosis induced by methylglyoxal by enhancing antioxidant defense.
基金Supported by the grant of Japan Society for the Promotion of Science(JSPS)KAKENHI(No.21K09729)a grant from Alcon Japan Ltd.,awarded to Horiguchi H.
文摘AIM:To compare the surgical outcomes of a multifocal intraocular lens(IOL;Lentis Comfort LS-313 MF15)with those of an enhanced monofocal IOL(Tecnis Eyhance DIB00V).METHODS:This retrospective study included patients who underwent cataract surgery with LS-313 MF15 or Eyhance IOL implantation.Data regarding patient demographics,surgical records,and ophthalmic examination before the cataract surgery and one and three months postoperatively were collected.Visual acuities,refractive values,defocus curves,contrast sensitivities and subjective symptoms were evaluated.RESULTS:Among the 71 eyes(47 patients)included in this study,32 eyes(20 patients)underwent LS-313 MF15 IOL implantation,and 39 eyes(27 patients)underwent Eyhance IOL implantation.No significant differences were observed in age,axial length,or refractive error between the two groups preoperatively.Furthermore,the distancecorrected and uncorrected distance visual acuities one month postoperatively did not differ between the groups,and both groups had sufficient visual acuities at the distances of 5,1 m,70,50,and 30 cm.Other ophthalmic data,including subjective symptoms based on the 14-item Visual Function Index Questionnaire,monocular defocus curves,contrast sensitivities,and halo and glare,did not differ between the groups three months postoperatively.Moreover,both groups had good outcomes.The spherical equivalent one month postoperatively was significantly myopic in the LS-313 MF15 group compared with that in the Eyhance group(P=0.033);however,this difference was not observed three months postoperatively(P=0.471).CONCLUSION:Comparison of the surgical outcomes of LS-313 MF15 with those of Eyhance with different optical properties reveal that both IOLs show good postoperative outcomes,with no significant differences being noted between the two IOLs.
基金supported by the German Research Foundation(DFG)under the project“Investigation and calculation of frost heave considering specific boundary conditions of ground freezing”(Grant No.409760547).
文摘The calculation of frost heaving with ice lens formation is still not standard for construction projects using artificial ground freezing(AGF).In fine-grained material,ice lenses may initiate and lead to significant heaving at the ground surface,which should be considered in advance.However,the complex processes during ice lens formation are still not fully understood and difficult to capture in a simple approach.In the past,the semi-analytical approach of Konrad and Morgenstern used one soil constant,the“segregation potential(SP)”.It has been mainly and most successfully applied to the heave calculation of natural-induced soil freezing in cold regions.Its application to AGF has been so far unsuccessful.To solve this,a new semi-analytical approach is presented in this paper.It includes AGF conditions such as bottom-up freezing,temperature gradients to reach great freezing velocities,and a distinction between two freezing states.One is the freezing-up state until a certain frost body thickness is reached(thermal transient state),and the other is a holding phase where the frost body thickness is kept constant(thermal quasi-steady state).To test its ability,the results are applied to another freezing direction,the top-down freezing.The new approach is validated using two different frost-susceptible soils and,in total,50 frost heave tests.In the thermal transient region,where the SP is applicable,the two semi-analytical approaches are compared,showing improved performance of the current method by about 15%.
基金Supported by Medical Science Foundation of Military for Young Scholars (No.19QNP064)Natural Science Foundation of Jiangsu Province (No.BK20191233)Jiangsu Funding Program for Excellent Postdoctoral Talent (No.2022ZB702)。
文摘AIM: To examine the protection of ferulic acid(FA) against ionizing radiation(IR)-induced lens injury in rats, as well as the underlying mechanisms.METHODS: FA(50 mg/kg) was administered to rats for 4 consecutive days before they were given 10 Gy γ-radiation, as well as for 3 consecutive days afterward. Two weeks after radiation, the eye tissues were collected. Histological alterations were evaluated by hematoxylineosin staining. Enzyme linked immunosorbent assay(ELISA) was utilized to assess the activities of glutathione reductase(GR) and superoxide dismutase(SOD), as well as the levels of glutathione(GSH) and malondialdehyde(MDA) in the lenses. The protein and m RNA levels of Bcl-2, caspase-3, Bax, heme oxygenase-1(HO-1), and glutamatecysteine ligase catalytic subunit(GCLC) were quantified using Western blot and quantitative reverse transcription polymerase chain reaction, respectively. With nuclear extracts, the nuclear factor erythroid-2 related factor(Nrf2) protein expressions in the nuclei were also measured.RESULTS: Rats exposed to IR showed lens histological alterations which could be alleviated by FA. FA treatment reversed apoptosis-related markers in IR-induced lens, as evidenced by lower levels of Bax and caspase-3 and higher level of Bcl-2. Furthermore, IR induced oxidative damage manifested by decreased GSH level, increased MDA level, and decreased SOD and GR activities. FA boosted nuclear translocation of Nrf2 and increased the expressions of HO-1 and GCLC to inhibit oxidative stress, as evidenced by an increase in GSH, a decrease in MDA, and an increase in GR and SOD activities.CONCLUSION: FA may work well in preventing and treating IR-induced cataract through promoting the Nrf2 signal pathway to attenuate oxidative damage and cell apoptosis.