Applied statisticians are often confronted with statistical inference problems dealing with situations in which there appear to be no data,or data of only limited usefulness.For example,when attempting to find a confi...Applied statisticians are often confronted with statistical inference problems dealing with situations in which there appear to be no data,or data of only limited usefulness.For example,when attempting to find a confidence interval for a binomial proportion,the sample may contain no successes.Such a scenario could be encountered when attempting to estimate the incidence of an extremely rare side effect associated with the administration of a newly developed drug.In this article,we use examples for our experiences working with scientific investigators and describe several scenarios in which there appeared to be no useful data,or data of only limited usefulness.We describe the methods we prefer for analyzing the data in these situations and illustrate their application using the actual data from the investigations we participated in.展开更多
Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean ...Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean Optics,Inc)having the optical resolution of 0.06 nm was used to record the emission spectra from 220 to 720 nm.Elements like Al,Ba,Ca,Cr,Cu,P,Fe,K,Mg,Mn,Na,P,S,Sr,and Zn were found to present in the samples.The relative abundances of the observed elements were calculated through standard calibration curve method,integrated intensity ratio method,and weight percentage LIBS approach.LIBS findings were validated by comparing its results with the results obtained using a typical analytical technique of Inductively Coupled plasma-optical emission spectroscopy(ICP-OES).Limit of detection(LOD)of the LIBS system was also estimated for heavy metals.The experience gain through this work implies that LIBS could be highly applicable for testing the quality and purity of food products.展开更多
Present study was aimed to develop and validate a reverse-phase high-performance liquid chromatography method for simultaneous determination of sitagliptin phosphate and metformin hy-drochloride in a marketed formulat...Present study was aimed to develop and validate a reverse-phase high-performance liquid chromatography method for simultaneous determination of sitagliptin phosphate and metformin hy-drochloride in a marketed formulation. The drug separation was performed on Hibar-240, Li-chrosphere-100 C18 ODS (250 × 4.6 mm, 5 μm) column, at a flow rate of 1 mL/min. The mobile phase used was a mixture of methanol: potassium di-hydrogen phosphate buffer at a ratio of 70:30 v/v. The detection was carried out at a wavelength of 266 nm. The retention times of sitagliptin phosphate and metformin hydrochloride were found as 6.1 and 4.9 min respectively. Linear calibration curves with good correlation coefficients were obtained over the concentration ranges of 10 - 50 μg/mL for sitagliptin and 20 - 100 μg/mL for metformin. The limit of detection was 0.016 and 0.14 μg/mL and the limit of quantification was 0.048 and 0.42 μg/mL for sitagliptin phosphate and metformin hydrochloride respectively. Validation of the method demonstrated system selectivity, specificity, linearity, accuracy and precision. The developed method was found useful in the simultaneous analysis of sitagliptin phosphate and metformin hydrochloride in formulation.展开更多
文摘Applied statisticians are often confronted with statistical inference problems dealing with situations in which there appear to be no data,or data of only limited usefulness.For example,when attempting to find a confidence interval for a binomial proportion,the sample may contain no successes.Such a scenario could be encountered when attempting to estimate the incidence of an extremely rare side effect associated with the administration of a newly developed drug.In this article,we use examples for our experiences working with scientific investigators and describe several scenarios in which there appeared to be no useful data,or data of only limited usefulness.We describe the methods we prefer for analyzing the data in these situations and illustrate their application using the actual data from the investigations we participated in.
文摘Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean Optics,Inc)having the optical resolution of 0.06 nm was used to record the emission spectra from 220 to 720 nm.Elements like Al,Ba,Ca,Cr,Cu,P,Fe,K,Mg,Mn,Na,P,S,Sr,and Zn were found to present in the samples.The relative abundances of the observed elements were calculated through standard calibration curve method,integrated intensity ratio method,and weight percentage LIBS approach.LIBS findings were validated by comparing its results with the results obtained using a typical analytical technique of Inductively Coupled plasma-optical emission spectroscopy(ICP-OES).Limit of detection(LOD)of the LIBS system was also estimated for heavy metals.The experience gain through this work implies that LIBS could be highly applicable for testing the quality and purity of food products.
文摘Present study was aimed to develop and validate a reverse-phase high-performance liquid chromatography method for simultaneous determination of sitagliptin phosphate and metformin hy-drochloride in a marketed formulation. The drug separation was performed on Hibar-240, Li-chrosphere-100 C18 ODS (250 × 4.6 mm, 5 μm) column, at a flow rate of 1 mL/min. The mobile phase used was a mixture of methanol: potassium di-hydrogen phosphate buffer at a ratio of 70:30 v/v. The detection was carried out at a wavelength of 266 nm. The retention times of sitagliptin phosphate and metformin hydrochloride were found as 6.1 and 4.9 min respectively. Linear calibration curves with good correlation coefficients were obtained over the concentration ranges of 10 - 50 μg/mL for sitagliptin and 20 - 100 μg/mL for metformin. The limit of detection was 0.016 and 0.14 μg/mL and the limit of quantification was 0.048 and 0.42 μg/mL for sitagliptin phosphate and metformin hydrochloride respectively. Validation of the method demonstrated system selectivity, specificity, linearity, accuracy and precision. The developed method was found useful in the simultaneous analysis of sitagliptin phosphate and metformin hydrochloride in formulation.