X-ray fluorescence microtomography based on polycapillary- focused X-rays from laboratory source 被引量:3
1
作者 Bing-Gang Feng Fen Tao +8 位作者 Yi-Ming Yang Tao Hu Fei-Xiang Wang Guo-Hao Du Yan-Ling Xue Ya-Jun Tong Tian-Xi Sun Biao Deng Ti-Qiao Xiao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第6期85-91,共7页
X-ray fluorescence microtomography(μXFCT)is a nondestructive analytical technique and has been widely used to nondestructively detect and quantify the elemental composition and distributions in samples. Usually, sync... X-ray fluorescence microtomography(μXFCT)is a nondestructive analytical technique and has been widely used to nondestructively detect and quantify the elemental composition and distributions in samples. Usually, synchrotron radiation X-rays are used for μXFCT, due to its high flux density. In this paper, a laboratory-sourcebased μXFCT system was developed, in which a polycapillary lens is employed to focus the X-ray beam and improve the flux density. The maximum likelihood expectation maximization algorithm was used to reconstruct the computed tomography slices at a limited number of projections. The experimental results demonstrated that the developed system could reveal the elemental distribution inside the test sample, with an elemental sensitivity of 1000 ppm. 展开更多
关键词 检查 荧光 实验室 期望最大化算法 采购 非破坏性 同步加速器 断层摄影术
下载PDF
Beam and image experiment of beam deflection electron gun for distributed X-ray sources 被引量:6
2
作者 Cheng-Jun Tan Chuan-Xiang Tang +7 位作者 Wen-Hui Huang Qing-Xiu Jin Ying-Chao Du Qun Luo Pei-Dong Wu Dong-Hai Liu Lu-Ming Zhang Cong Xu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第3期127-138,共12页
Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative s... Distributed X-ray sources comprise a single vacuum chamber containing multiple X-ray sources that are triggered and emit X-rays at a specific time and location. This process facilitates an application for innovative system concepts in X-ray and computer tomography. This paper proposes a novel electron beam focusing, shaping,and deflection electron gun for distributed X-ray sources.The electron gun uses a dispenser cathode as an electron emitter, a mesh grid to control emission current, and two electrostatic lenses for beam shaping, focusing, and deflection. Novel focusing and deflecting electrodes were designed to increase the number of focal spots in the distributed source. Two identical half-rectangle opening electrodes are controlled by adjusting the potential of the two electrodes to control the electron beam trajectory, and then, multifocal spots are obtained on the anode target. The electron gun can increase the spatial density of the distributed X-ray sources, thereby improving the image quality. The beam experimental results show that the focal spot sizes of the deflected(deflected amplitude 10.5 mm)and non-deflected electron beams at full width at half maximum are 0.80 mm 90.50 mm and 0.55 mm 90.40 mm, respectively(anode voltage 160 kV; beam current 30 mA). The imaging experimental results demonstrate the excellent spatial resolution and time resolution of an imaging system built with the sources, which has an excellent imaging effect on a field-programmable gate array chip and a rotating metal disk. 展开更多
关键词 BEAM DEFLECTION electron GUN x-ray imaging DISTRIBUTED x-ray sources STATIONARY CT
下载PDF
Laser-produced plasma helium-like titanium Kα x-ray source and its application to Rayleigh-Taylor instability study 被引量:1
3
作者 王瑞荣 陈伟民 +2 位作者 王伟 董佳钦 肖沙里 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第7期362-368,共7页
Several experiments are performed on the ShenGuang-Ⅱ laser facility to investigate an x-ray source and test radiography concepts. X-ray lines emitted from laser-produced plasmas are the most practical means of genera... Several experiments are performed on the ShenGuang-Ⅱ laser facility to investigate an x-ray source and test radiography concepts. X-ray lines emitted from laser-produced plasmas are the most practical means of generating these high intensity sources. By using a time-integrated space-resolved keV spectroscope and pinhole camera, potential helium-like titanium Kα x-ray backlighting (radiography) line source is studied as a function of laser wavelength, ratio of pre-pulse intensity to main pulse intensity, and laser intensity (from 7.25 to ~ 11.3 × 10^15 W/cm2). One-dimensional radiography using a grid consisting of 5 #m Au wires on 16 μm period and the pinhole-assisted point projection is tested. The measurements show that the size of the helium-like titanium Ka source from a simple foil target is larger than 100 ~m, and relative x-ray line emission conversion efficiency ~x from the incident laser light energy to helium- like titanium K-shell spectrum increases significantly with pre-pulse intensity increasing, increases rapidly with laser wavelength decreasing, and increases moderately with main laser intensity increasing. It is also found that a gold gird foils can reach an imaging resolution better than 5-μm featured with high contrast. It is further demonstrated that the pinhole-assisted point projection at such a level will be a novel two-dimensional imaging diagnostic technique for inertial confinement fusion experiments. 展开更多
关键词 x-ray source plasma diagnostic techniques x-ray spectra
下载PDF
Optimization of 4.7-keV X-ray titanium sources driven by 100-ps laser pulses 被引量:1
4
作者 熊俊 董佳钦 +4 位作者 贾果 王瑞荣 王伟 傅思祖 郑无敌 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第6期454-458,共5页
An experiment with thin titanium foils irradiated by two pulses delayed in time is conducted on the bnenguang-Il laser facility. A prepulse induces an underdense plasma, 2-ns later a main pulse (λL ≈ 0.35 μm, EL ... An experiment with thin titanium foils irradiated by two pulses delayed in time is conducted on the bnenguang-Il laser facility. A prepulse induces an underdense plasma, 2-ns later a main pulse (λL ≈ 0.35 μm, EL ≈120 J, τL ≈100 ps) is injected into the underdense plasma and produces strong line emission from the titanium K shell (i.e., Hea at 4.7 keV). Data show that the intensity of 4.7-keV X-ray emission with the prepulse is approximately twice more than without the prepulse, and can be used as a backlighting source satisfying the diagnostic requirements for dense plasma probing. High- quality plasma images are obtained with the backlighfing 4.7-keV X-rays in a Rayleigh-Taylor hydrodynamic instability experiment. 展开更多
关键词 x-ray source PREPULSE titanium foil
下载PDF
Viral Contamination Source in Clinical Microbiology Laboratory 被引量:1
5
作者 WANG Xin Ling SONG Juan +4 位作者 SONG Qin Qin YU Jie LUO Xiao Nuan WU Gui Zhen HAN Jun 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2016年第8期609-611,共3页
To understand the potential causes of laboratory-acquired infections and to provide possible solutions that would protect laboratory personnel, samples from a viral laboratory were screened to determine the main sourc... To understand the potential causes of laboratory-acquired infections and to provide possible solutions that would protect laboratory personnel, samples from a viral laboratory were screened to determine the main sources of contamination with six subtypes of Rhinovirus. Rhinovirus contamination was found in the gloves, cuffs of protective wear, inner surface of biological safety cabinet (BSC) windows, and trash handles. Remarkably, high contamination was found on the inner walls of the centrifuge and the inner surface of centrifuge tube casing in the rotor. Spilling infectious medium on the surface of centrifuge tubes was found to contribute to contamination of centrifuge surfaces. Exposure to sodium hypochlorite containing no less than 0.2 g/L available chlorine decontaminated the surface of the centrifuRe tubes from Rhinovirus after 2 min. 展开更多
关键词 Viral Contamination source in Clinical Microbiology laboratory BSC HRV
下载PDF
Development of a seven-cell S-band standing-wave RF-deflecting cavity for Tsinghua Thomson scattering X-ray source 被引量:1
6
作者 Xian-Cai Lin Hao Zha +4 位作者 Jia-Ru Shi Liu-Yuan Zhou Shuang Liu Jian Gao Huai-Bi Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第4期20-29,共10页
A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and p... A 2856-MHz,π-mode,seven-cell standingwave deflecting cavity was designed and fabricated for bunch length measurement in Tsinghua Thomson scattering X-ray source(TTX)facility.This cavity was installed in the TTX and provided a deflecting voltage of 4.2 MV with an input power of 2.5 MW.Bunch length diagnoses of electron beams with energies up to 39 MeV have been performed.In this article,the RF design of the cavity using HFSS,fabrication,and RF test processes are reviewed.High-power operation with accelerated beams and calibration of the deflecting voltage are also presented. 展开更多
关键词 Deflecting RF cavity Standing wave Bunchlength measurement Thomson x-ray source
下载PDF
Experimental Study of the X-Ray Radiation Source at Approximately Constant Radiation Temperature 被引量:1
7
作者 宋天明 杨家敏 +2 位作者 杨冬 李志超 尚万里 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第11期1108-1111,共4页
An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the... An X-ray radiation source with approximately constant radiation temperature is realized by irradiating golden hohlraum with a shaped laser pulse. A simple theoretical model based on power balance is used to design the shape of the drive laser pulse. Experiments are carried out on the Shenguang III prototype laser facility, and the experimentM results are presented for radiation sources with the flat-top lasting about 2.5 ns at two different peak temperatures of about 150 eV and 170 eV, respectively, including the the drive laser pulses and the time integrated possible improvements are discussed. time histories of the temperatures, the shapes of radiation spectra. The validity of the model and 展开更多
关键词 x-ray radiation source laser pulse shaping power balance
下载PDF
Numerical simulation for all-optical Thomson scattering X-ray source
8
作者 谭放 朱斌 +5 位作者 韩丹 辛建婷 赵宗清 曹磊峰 谷渝秋 张保汉 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第3期249-255,共7页
Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-... Energy spectra, angular distributions, and temporal profiles of the photons produced by an all-optical Thomson scat- tering X-ray source are explored through numerical simulations based on the parameters of the SILEX-I laser system (800 nm, 30 fs, 300 TW) and the previous wakefield acceleration experimental results. The simulation results show that X-ray pulses with a duration of 30 fs and an emission angle of 50 mrad can be produced from such a source. Using the optimized electron parameters, X-ray pulses with better directivity and narrower energy spectra can be obtained. Besides the electron parameters, the laser parameters such as the wavelength, pulse duration, and spot size also affect the X-ray yield, the angular distribution, and the maximum photon energy, except the X-ray pulse duration which is slightly changed for the case of ultrafast laser-electron interaction. 展开更多
关键词 ultrashort laser wakefield acceleration Thomson scattering x-ray source
下载PDF
Low Energy Plasma Focus as an Intense X-ray Source for Radiography
9
作者 S.Hussain M.Zakaullah +1 位作者 Shujaat Ali A.Waheed 《Plasma Science and Technology》 SCIE EI CAS CSCD 2004年第3期2296-2300,共5页
Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode ... Study on X-ray emission from a low energy (1.8 kJ) plasma focus devicepowered by a 9 μF capacitor bank, charged at 20 kV and giving peak discharge current of about 175kA by using a lead-inserted copper-tapered anode is reported. The X-ray yield in different energywindows is measured as a function of hydrogen filling pressure. The maximum yield in 4π-geometry isfound to be (27.3+-1.1) J and corresponding wall plug efficiency for X-ray generation is 1.52+-0.06%. X-ray emission, presumably due to bombarding activity of electrons in current sheath at theanode tip was dominant, which is confirmed by the pinhole images. The feasibility of the device asan intense X-ray source for radiography is demonstrated. 展开更多
关键词 plasma focus x-ray source RADIOGRAPHY
下载PDF
Studying a kind of portable ultra-bright microfocus x-ray source
10
作者 王凯歌 王雷 牛憨笨 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第5期1807-1813,共7页
This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusi... This paper studies the properties of a kind of portable ultra-bright microfocus x-ray source with the Monte-Carlo method in detail. The new x-ray source consists of an electron-emission system, an electrostatic focusing system and a metal target. A crystal Lanthanum Hexaboride cathode, a Wehnelt grid and an extracted electrode compose the triode electrode electron-gun system. Two equal radius cylinder electrodes form the focusing system. The key factors determining the focus properties of the electron beam such as the ratio Dw/H, grid bias Vg, and the properties of the extracted electrode arc numerically studied. The calculated results reveal that when Dw/H, Vg, the length of the extracted electrode, and the distance between the grid and the extracted electrode equals 5, q).6 kV, 10 mm, and 8 mm respectively, the electron beam focal spot can be concentrated down to 9 μm in radius and a reasonable focal length about 72.5 mm can be achieved, at the same time, the cathode emission currents can be as high as 30 mA. 展开更多
关键词 microfocus x-ray source high brightness micro-focal spot Monte-Carlo method
下载PDF
Phase Imaging Using Laser-produced X-ray Sources
11
作者 程静 张长学 韩申生 《Plasma Science and Technology》 SCIE EI CAS CSCD 2000年第4期411-413,共3页
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. We established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profil... A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. We established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging. 展开更多
关键词 Phase Imaging Using Laser-produced x-ray sources THAN
下载PDF
Self Consistent Calibration of Detectors and Sources for Hard and Soft X-Ray Diagnostics
12
作者 Danilo Pacella Afra Romano +3 位作者 Seung Hun Lee Federica Causa Lori Gabellieri Wonho Choe 《Modern Instrumentation》 2014年第3期13-23,共11页
X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. ... X-Ray sources, detectors and optical components are now used in a wide range of applications. What is crucial is the absolute calibration of such devices to permit a quantitative assessment of the system under study. A new X-ray laboratory has been built in Frascati (ENEA) to develop diagnostics for nuclear fusion experiments and study applications of these X-ray techniques in other domains, like new material science, non destructive tests and so on. An in-house developed selfconsistent calibration procedure is described that permits the absolute calibration of sources (X-ray emitted fluxes) and detectors (detection efficiencies) as function of the X-ray photon energy, in the range 2 - 120 keV. The calibration procedure involves the use of an in-house developed code that also predicts the spectral response of any detector in any experimental condition that can be setup in the laboratory. The procedure has been then applied for the calibration and characterisation of gas and solid state imaging detectors, such as Medipix-2, GEM gas detector, CCD camera, Cd-Te C-MOS imager, demonstrating the versatility of the method developed here. 展开更多
关键词 x-ray Detector x-ray source ABSOLUTE CALIBRATION Plasma Physics DIAGNOSTICS
下载PDF
Mineralogical study of surface sediments in the western Arctic Ocean and their implications for material sources 被引量:2
13
作者 DONG Linsen SHI Xuefa +5 位作者 LIU Yanguang FANG Xisheng CHEN Zhihua WANG Chunjuan ZOU Jianjun HUANG Yuanhui 《Advances in Polar Science》 2014年第3期192-203,共12页
Mineralogical analysis was performed on bulk sediments of 79 surface samples using X-ray diffraction. The analytical results, combined with data on ocean currents and the regional geological background, were used to i... Mineralogical analysis was performed on bulk sediments of 79 surface samples using X-ray diffraction. The analytical results, combined with data on ocean currents and the regional geological background, were used to investigate the mineral sources. Mineral assemblages in sediments and their distribution in the study area indicate that the material sources are complex. (1) Feldspar is abundant in the sediments of the middle Chukchi Sea near the Bering Strait, originating from sediments in the Anadyr River carried by the Anadyr Current. Sediments deposited on the western side of the Chukchi Sea are rich in feldspar. Compared with other areas, sediments in this region are rich in hornblende transported from volcanic and sedimentary rocks in Siberia by the Anadyr Stream and the Siberian Coastal Current. Sediments in the eastern Chukchi Sea are rich in quartz sourced from sediments of the Yukon and Kuskokwim rivers carried by the Alaska Coastal Current. Sediments in the northern Chukchi Sea are rich in quartz and carbonates from the Mackenzie River sediments. (2) Sediments of the southern and central Canada Basin contain little calcite and dolomite, mainly due to the small impact of the Beaufort Gyre carrying carbonates from the Canadian Arctic Islands. Compared with other areas, the mica content in the region is high, implying that the Laptev Sea is the main sediment source for the southern and central Canada Basin. In the other deep sea areas, calcite and dolomite levels are high caused by the input of large amounts of sediment carried by the Beaufort Gyre from the Canadian Arctic Islands (Banks and Victoria). The Siberian Laptev Sea also provides small amounts of sediment for this region. Furthermore, the Atlantic mid-water contributes some fine-grained material to the entire deep western Arctic Ocean. 展开更多
关键词 x-ray diffraction western Arctic Ocean MINERALS surface sediments sourceS
下载PDF
X-Ray from Laser Produced Plasma as an Excitation Source in Spectroscopy Study
14
作者 周赤 王骐 +1 位作者 李思宁 马祖光 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 1994年第2期71-74,共4页
X-RayfromLaserProducedPlasmaasanExcitationSourceinSpectroscopyStudy¥(周赤)(王骐)(李思宁)(马祖光)ZHOUChi;WANGQi;LISinin... X-RayfromLaserProducedPlasmaasanExcitationSourceinSpectroscopyStudy¥(周赤)(王骐)(李思宁)(马祖光)ZHOUChi;WANGQi;LISining;MAZuguang(Dept.... 展开更多
关键词 ss:Laser PLASMA PUMPING source x-ray
下载PDF
High-brightness photo-injector with standing-wave buncher-based ballistic bunching scheme for inverse Compton scattering light source
15
作者 Jian-Xin Wang Kui Zhou +7 位作者 Peng Li De-Xin Xiao Li-Jun Shan Xu-Ming Shen Yu Liu Zheng Zhou Han-Bin Wang Dai Wu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第4期51-61,共11页
We report our recent progress in the design and simulation of a high-brightness S-band photo-injector with a ballistic bunching scheme aimed at driving an inverse Compton scattering(ICS)X-ray source.By adding a short ... We report our recent progress in the design and simulation of a high-brightness S-band photo-injector with a ballistic bunching scheme aimed at driving an inverse Compton scattering(ICS)X-ray source.By adding a short standing-wave buncher between the RF gun and first booster in a conventional S-band photo-injector,electron bunches with a 500 pC charge can be compressed to the sub-picosecond level with very limited input RF power and an unchanged basic layout of the photo-injector.Beam dynamics analysis indicates that fine tuning of the focusing strength of the gun and linac solenoid can well balance additional focusing provided by the standing wave buncher and generate a well-compensated transverse emittance.Thorough bunching dynamics simulations with different operating conditions of the buncher show that a buncher with more cells and a moderate gradient is suitable for simultaneously obtaining a short bunch duration and low emittance.In a typical case of a 9-cell buncher with a 38 MV/m gradient,an ultrashort bunch duration of 0.5 ps(corresponding to a compression ratio of>5)and a low emittance of<1 mm mrad can be readily obtained for a 500 pC electron pulse.This feasible ballistic bunching scheme will facilitate the implementation of an ultrashort pulse mode inverse Compton scattering X-ray source on most existing S-band photo-injectors. 展开更多
关键词 Beam brightness Ballistic bunching Emittance compensation Compton scattering x-ray source
下载PDF
Continued Study on Hohlraum Radiation Source with Approximately Constant Radiation Temperature
16
作者 宋天明 杨家敏 +2 位作者 朱托 李志超 黄成武 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第4期342-345,共4页
An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A ... An experiment was performed on the Shenguang III prototype laser facility to continue the study on hohlraum radiation source with approximately constant radiation temperature using a continuously shaped laser pulse.A radiation source with a flattop temperature of about130 e V that lasted about 5 ns was obtained.The previous analytical iteration method based on power balance and self-similar solution of ablation was modified taking into account the plasma movements and it was used to design the laser pulse shape for experiment.A comparison between experimental results and simulation is presented and better agreement was achieved using the modified method.Further improvements are discussed. 展开更多
关键词 x-ray radiation source laser pulse shaping power balance
下载PDF
A small electron beam ion trap/source facility for electron/neutral-ion collisional spectroscopy in astrophysical plasmas
17
作者 Gui-Yun Liang Hui-Gang Wei +8 位作者 Da-Wei Yuan Fei-Lu Wang Ji-Min Peng Jia-Yong Zhong Xiao-Long Zhu Mike Schmidt Günter Zschornack Xin-Wen Ma Gang Zhao 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2018年第1期1-10,共10页
Spectra are fundamental observation data used for astronomical research,but understanding them strongly depends on theoretical models with many fundamental parameters from theoretical calculations.Different models giv... Spectra are fundamental observation data used for astronomical research,but understanding them strongly depends on theoretical models with many fundamental parameters from theoretical calculations.Different models give different insights for understanding a specific object.Hence,laboratory benchmarks for these theoretical models become necessary.An electron beam ion trap is an ideal facility for spectroscopic benchmarks due to its similar conditions of electron density and temperature compared to astrophysical plasmas in stellar coronae,supernova remnants and so on.In this paper,we will describe the performance of a small electron beam ion trap/source facility installed at National Astronomical Observatories,Chinese Academy of Sciences.We present some preliminary experimental results on X-ray emission,ion production,the ionization process of trapped ions as well as the effects of charge exchange on the ionization. 展开更多
关键词 x-ray:general atomic processes line:formation method:laboratory:atomic
下载PDF
Two Monte Carlo-based simulators for imaging-system modeling and projection simulation of flat-panel X-ray source
18
作者 Meng-Ke Qi Ting He +7 位作者 Yi-Wen Zhou Jing Kang Zeng-Xiang Pan Song Kang Wang-Jiang Wu Jun Chen Ling-Hong Zhou Yuan Xu 《Nuclear Science and Techniques》 SCIE EI CAS 2024年第7期31-46,共16页
The advantages of a flat-panel X-ray source(FPXS)make it a promising candidate for imaging applications.Accurate imaging-system modeling and projection simulation are critical for analyzing imaging performance and res... The advantages of a flat-panel X-ray source(FPXS)make it a promising candidate for imaging applications.Accurate imaging-system modeling and projection simulation are critical for analyzing imaging performance and resolving overlapping projection issues in FPXS.The conventional analytical ray-tracing approach is limited by the number of patterns and is not applicable to FPXS-projection calculations.However,the computation time of Monte Carlo(MC)simulation is independent of the size of the patterned arrays in FPXS.This study proposes two high-efficiency MC projection simulators for FPXS:a graphics processing unit(GPU)-based phase-space sampling MC(gPSMC)simulator and GPU-based fluence sampling MC(gFSMC)simulator.The two simulators comprise three components:imaging-system modeling,photon initialization,and physical-interaction simulations in the phantom.Imaging-system modeling was performed by modeling the FPXS,imaging geometry,and detector.The gPSMC simulator samples the initial photons from the phase space,whereas the gFSMC simulator performs photon initialization from the calculated energy spectrum and fluence map.The entire process of photon interaction with the geometry and arrival at the detector was simulated in parallel using multiple GPU kernels,and projections based on the two simulators were calculated.The accuracies of the two simulators were evaluated by comparing them with the conventional analytical ray-tracing approach and acquired projections,and the efficiencies were evaluated by comparing the computation time.The results of simulated and realistic experiments illustrate the accuracy and efficiency of the proposed gPSMC and gFSMC simulators in the projection calculation of various phantoms. 展开更多
关键词 Flat-panel x-ray source(FPXS) Imaging-system modeling Projection simulation Monte Carlo-based simulators
下载PDF
基于智慧计量实验室的多源异构检测数据智能提取技术研究
19
作者 郑安刚 张天宜 +2 位作者 杨玉博 尚怀嬴 任毅 《电测与仪表》 北大核心 2024年第8期70-77,共8页
文章在解决智慧计量实验室中多源异构检测数据的提取与处理问题,对计量实验室检测数据类型和异构类信息提取面临的问题进行分析,提出基于图像处理的检测数据提取技术路线;设计了一种基于可微分二值化网络(differentiable binarization n... 文章在解决智慧计量实验室中多源异构检测数据的提取与处理问题,对计量实验室检测数据类型和异构类信息提取面临的问题进行分析,提出基于图像处理的检测数据提取技术路线;设计了一种基于可微分二值化网络(differentiable binarization networks,DBNet)和卷积循环神经网络(convolutional recurrent neural network,CRNN)的检测数据智能提取技术,实现了对多源异构数据的自动检测、识别和提取。在此基础上,研制了多源异构检测数据智能提取装置,并进行了验证,结果表明,该装置能够有效地提取纸质报告或表单中的检测数据等关键信息,具有较高的准确性和较快的响应速度,为智慧计量实验室的数据管理和分析提供了有力支持。该研究对于推动智慧计量实验室的建设和试验检测数据应用具有重要意义。 展开更多
关键词 智慧计量实验室 多源异构数据 智能提取 深度学习
下载PDF
基于多源特征融合的实验室不安全行为检测系统设计
20
作者 张国志 张晓文 《现代电子技术》 北大核心 2024年第12期52-56,共5页
为降低实验室事故发生率,设计一种基于多源特征融合的实验室不安全行为检测系统。首先,构建系统基础框架,在图像采集单元中利用高清摄像机获取实验室监控视频图像,经过图像处理单元的灰度化、去噪、平滑滤波处理后,在目标识别单元中采... 为降低实验室事故发生率,设计一种基于多源特征融合的实验室不安全行为检测系统。首先,构建系统基础框架,在图像采集单元中利用高清摄像机获取实验室监控视频图像,经过图像处理单元的灰度化、去噪、平滑滤波处理后,在目标识别单元中采用帧间差分法获得视频目标区域图像;然后,在特征提取单元中处理视频目标区域图像,提取HOG特征以及人体行为重心特征,通过对二者进行融合处理得到一维特征向量,将其输入到行为检测单元中,利用SVM分类器检测不安全行为。实验结果表明:所设计系统可有效检测实验室不安全行为,F1指数均值、召回率均值分别为98.94%、99.15%,错误检测数量较少。 展开更多
关键词 多源特征融合 实验室 不安全行为检测 多源特征提取 HOG特征 SVM分类器
下载PDF