Development of the laminar flow cooling control system of the No.3 hot strip rolling line at Baosteel 被引量:1
1
作者 Hang Zhiliang Wu Jianfeng Zhang Zhiyong 《Baosteel Technical Research》 CAS 2008年第4期39-42,共4页
The coiling temperature of the hot strip rolling process plays an important role in strip quality control. The newly-built laminar flow cooling control system was independently developed by Baosteel. L2 conducts total... The coiling temperature of the hot strip rolling process plays an important role in strip quality control. The newly-built laminar flow cooling control system was independently developed by Baosteel. L2 conducts totally dynamic control (L1 only executes the result from L2, and does not conduct any dynamic control ). The system has many advantages, such as quick real-time control, accurate model calculation, quick response after self-adaptation, etc. Compared with the 2050 mm hot strip rolling line,the new system can satisfy the strict cooling requirements of high strength steel, silicon steel and heavy plates because of its newly-developed technologies of cooling rate control, strip cooling by sections and proportion-integral-differential coefficient (PID) feedback fuzzy control. 展开更多
关键词 laminar flow cooling FEEDFORWARD FEEDBACK SELF-ADAPTATION
下载PDF
Mathematic modeling on flexible cooling system in hot strip mill 被引量:4
2
作者 彭良贵 刘相华 +1 位作者 赵宪明 吴迪 《Journal of Central South University》 SCIE EI CAS 2014年第1期43-49,共7页
A novel cooling system combining ultra fast cooling rigs with laminar cooling devices was investigated.Based on the different cooling mechanisms,a serial of mathematic models were established to describe the relations... A novel cooling system combining ultra fast cooling rigs with laminar cooling devices was investigated.Based on the different cooling mechanisms,a serial of mathematic models were established to describe the relationship between water flow and spraying pressure and the relationship between water spraying heat flux and layout of nozzles installed on the top and bottom cooling headers.Model parameters were validated by measured data.Heat transfer models including air convection model,heat radiation model and water cooling capacity model were detailedly introduced.In addition,effects on cooling capacity by water temperature and different valve patterns were also presented.Finally,the comparison results from UFC used or not have been provided with respect to temperature evolution and mechanical properties of Q235B steel grade with thickness of 7.8 mm.Since online application of the sophisticated CTC process control system based on these models,run-out table cooling control system has been running stably and reliably to produce resource-saving,low-cost steels with smaller grain size. 展开更多
关键词 mathematic model ultra fast cooling laminar flow cooling variable frequency control coiling temperature control