The evaluation of the microcirculatory bed functional state and the identification of angiospastic disorders with related complications,when the pathological changes are reversible,have an important role in medical pr...The evaluation of the microcirculatory bed functional state and the identification of angiospastic disorders with related complications,when the pathological changes are reversible,have an important role in medical practice.The aim of this study was to evaluate the possibility of using optical noninvasive methods and the cold pressor test to solve this problem.A total of 33 patients with rheumatological diseases and 32 healthy volunteers were included in the study.Laser Doppler flowmetry,tissue reflectance oximetry and pulse oximetry were used as optical noninvasive methods.The parameters were recorded before,immediately after and 20 min after the cold pressor test.Based on the measured parameters,the complex parameters of the microcirculatory bed were calculated.A detailed statistical analysis of the parameter changes for each individual in the two groups displayed diverse microcirculatory bed parameter responses upon cold exposure,with differing recovery of parameters after CPT.New diagnostic criteria were proposed for the identification of angiospastic disorders.According to the proposed criteria,27 people of the volunteers group were confirmed to not display any disorders.In the patient group,however,18 people were observed to have a relatively normal functional state of the microcirculatory bed,while 15 people were observed to have a possible tendency to angiospasm.To highlight the diferences between a relatively normal state and presence of angiospastic disorders,statistical analysis of experimental data was carried out,which revealed significant differences.Further analysis of data with angiospastic disorders identified a relationship between their diagnoses and the results of labo-ratory studies.Thus,the evaluation of combined noninvasive optical diagnostic method use,the cold pressor test and proposed diagnostic criteria showed a positive result.This approach can be used to detect the presence of possible angiospastic disorders and related complications,as well as mi-crocirculatory bed disorders against the background of other diseases.展开更多
Objective To investigate lateralization and Coherence analysis of blood perfusion in bilateral Neiguan (内关 PC 6) in different ages. Methods Healthy volunteers (n=30) were placed in a temperature-controlled room ...Objective To investigate lateralization and Coherence analysis of blood perfusion in bilateral Neiguan (内关 PC 6) in different ages. Methods Healthy volunteers (n=30) were placed in a temperature-controlled room as a resting state for 40 min. Then the blood perfusion of bilateral PC 6 were carried out using PeriFlux System 5000 for 25 minutes. Mean blood flux of every 5 minutes was calculated. Then the participants were divided into groups of young (n=18) and the old (n=12) as the boundary of 40 years, the asymmetry index and coherence value of bilateral PC 6 were analyzed in different group. Results The mean blood flow of the right PC 6 was significantly higher than the left PC 6 in three different epochs, the mean blood flow of right PC 6 vs left PC 6 is 9.74±3.36 vs 6.73±2.22 (t=5.9, P〈0.001), 9.83±3.63 vs 6.99±2.37 (t=5.11, P〈0.001) and 9.69±3.40 vs 6.77±2.32 (t=5.99, P〈0.001), respectively. Although the asymmetry index is higher in old group than in young group, there is no statistically significant age-related differences. Coherence analysis suggest that there is significant difference in frequency value corresponding to peak crest between young and old group. Conclusion The blood perfusion in right PC 6 is higher than left PC 6. Coherence analysis of laser Doppler flowmetry signals in bilateral PC 6 might provide a potential non-invasive method to assess microcirculatory changes in different ages.展开更多
Nicotinamide adenine dinucleotide (NADH/NAD+) is involved in important biochemical reactions in human metabolism, including participation in energy production by mitochondria. The changes in fluorescence intensity as ...Nicotinamide adenine dinucleotide (NADH/NAD+) is involved in important biochemical reactions in human metabolism, including participation in energy production by mitochondria. The changes in fluorescence intensity as a function of time in response to blocking and releasing of blood flow in a forearm are used as a measure of oxygen transport with blood to the tissue, which directly correlates with the skin microcirculation status. In this paper, a non-invasive dynamic monitoring system based on blood flow-mediated skin fluorescence (FMSF) technology is developed to monitor the NADH fluorescence intensity of skin tissue during the process of blocking reactive hyperemia. Simultaneously, laser speckle contrast imaging (LSCI) and laser Doppler flowmetry (LDF) were used to observe blood flow, blood oxygen saturation (SOt2) and relative amount of hemoglobin (rHb) during the measurement process, which helped to explore NADH dynamics relevant physiological changes. A variety of parameters have been derived to describe NADH fluorescence curve based on the FMSF device. The experimental results are conducive to understanding the NADH measurement and the physiological processes related to it, which help FMSF to be a great avenue for in vivo physiological, clinical and pharmacological research on mitochondrial metabolism.展开更多
文摘The evaluation of the microcirculatory bed functional state and the identification of angiospastic disorders with related complications,when the pathological changes are reversible,have an important role in medical practice.The aim of this study was to evaluate the possibility of using optical noninvasive methods and the cold pressor test to solve this problem.A total of 33 patients with rheumatological diseases and 32 healthy volunteers were included in the study.Laser Doppler flowmetry,tissue reflectance oximetry and pulse oximetry were used as optical noninvasive methods.The parameters were recorded before,immediately after and 20 min after the cold pressor test.Based on the measured parameters,the complex parameters of the microcirculatory bed were calculated.A detailed statistical analysis of the parameter changes for each individual in the two groups displayed diverse microcirculatory bed parameter responses upon cold exposure,with differing recovery of parameters after CPT.New diagnostic criteria were proposed for the identification of angiospastic disorders.According to the proposed criteria,27 people of the volunteers group were confirmed to not display any disorders.In the patient group,however,18 people were observed to have a relatively normal functional state of the microcirculatory bed,while 15 people were observed to have a possible tendency to angiospasm.To highlight the diferences between a relatively normal state and presence of angiospastic disorders,statistical analysis of experimental data was carried out,which revealed significant differences.Further analysis of data with angiospastic disorders identified a relationship between their diagnoses and the results of labo-ratory studies.Thus,the evaluation of combined noninvasive optical diagnostic method use,the cold pressor test and proposed diagnostic criteria showed a positive result.This approach can be used to detect the presence of possible angiospastic disorders and related complications,as well as mi-crocirculatory bed disorders against the background of other diseases.
基金Supported by the Fundamental Research Funds for the Central Public Welfare Research Institutes:ZZ070806National Natural Science Foundation of China:81001553National Basic Research Program of China:2015CB554502
文摘Objective To investigate lateralization and Coherence analysis of blood perfusion in bilateral Neiguan (内关 PC 6) in different ages. Methods Healthy volunteers (n=30) were placed in a temperature-controlled room as a resting state for 40 min. Then the blood perfusion of bilateral PC 6 were carried out using PeriFlux System 5000 for 25 minutes. Mean blood flux of every 5 minutes was calculated. Then the participants were divided into groups of young (n=18) and the old (n=12) as the boundary of 40 years, the asymmetry index and coherence value of bilateral PC 6 were analyzed in different group. Results The mean blood flow of the right PC 6 was significantly higher than the left PC 6 in three different epochs, the mean blood flow of right PC 6 vs left PC 6 is 9.74±3.36 vs 6.73±2.22 (t=5.9, P〈0.001), 9.83±3.63 vs 6.99±2.37 (t=5.11, P〈0.001) and 9.69±3.40 vs 6.77±2.32 (t=5.99, P〈0.001), respectively. Although the asymmetry index is higher in old group than in young group, there is no statistically significant age-related differences. Coherence analysis suggest that there is significant difference in frequency value corresponding to peak crest between young and old group. Conclusion The blood perfusion in right PC 6 is higher than left PC 6. Coherence analysis of laser Doppler flowmetry signals in bilateral PC 6 might provide a potential non-invasive method to assess microcirculatory changes in different ages.
文摘Nicotinamide adenine dinucleotide (NADH/NAD+) is involved in important biochemical reactions in human metabolism, including participation in energy production by mitochondria. The changes in fluorescence intensity as a function of time in response to blocking and releasing of blood flow in a forearm are used as a measure of oxygen transport with blood to the tissue, which directly correlates with the skin microcirculation status. In this paper, a non-invasive dynamic monitoring system based on blood flow-mediated skin fluorescence (FMSF) technology is developed to monitor the NADH fluorescence intensity of skin tissue during the process of blocking reactive hyperemia. Simultaneously, laser speckle contrast imaging (LSCI) and laser Doppler flowmetry (LDF) were used to observe blood flow, blood oxygen saturation (SOt2) and relative amount of hemoglobin (rHb) during the measurement process, which helped to explore NADH dynamics relevant physiological changes. A variety of parameters have been derived to describe NADH fluorescence curve based on the FMSF device. The experimental results are conducive to understanding the NADH measurement and the physiological processes related to it, which help FMSF to be a great avenue for in vivo physiological, clinical and pharmacological research on mitochondrial metabolism.