期刊文献+
共找到167篇文章
< 1 2 9 >
每页显示 20 50 100
<i>In Situ</i>Analysis of Copper Alloys by Femtosecond Laser Ablation Inductively Coupled Plasma Mass Spectrometry: Constrains on Matrix Effects
1
作者 Germán Velásquez Anastassia Y. Borisova +1 位作者 Sandrine Baron Luc Robbiola 《American Journal of Analytical Chemistry》 2018年第3期150-161,共12页
Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix m... Direct analysis of copper-base alloys using laser ablation techniques is an increasingly common procedure in cultural heritage studies. However, main discussions remain focused on the possibility of using non-matrix matched external reference materials. To evaluate the occurrence of matrix effects during in situ microanalysis of copper-base materials, using near infrared femtosecond laser ablation techniques (NIR fs-LA-ICP-MS), two bronzes, i.e., (Sn-Zn)-ternary and (Sn)-binary copper-matrix reference materials, as well as a reference synthetic glass (NIST-SRM-610) have been analyzed. The results have been compared to data obtained on a sulfide-matrix reference material. Similar values in relative sensitivity averages of 63Cu, 118Sn and 66Zn, as well as in 118Sn/63Cu and 66Zn/63Cu ratios were obtained, for all analyzed matrix types, i.e., copper-base-, silicate-, and sulfide-reference materials. Consequently, it is possible to determinate major and minor element concentrations in copper alloys, i.e., Cu, Sn and Zn, using silicate and sulfide reference materials as external calibrators, without any matrix effect and over a wide range of concentrations (from wt.% to ppm). Equally, Cu, Sn and Zn concentrations can be precisely determined in sulfides using homogeneous alloys (reference) materials as an external calibrator. Thus, it is possible to determine Cu, Sn and Zn in copper-base materials and their ore minerals, mostly sulfides, in a single analytical session, without requiring specific external calibrators for each matrix type. In contrast, immiscible elements in copper matrix, such as Pb and Fe show notable differences in their relative sensitivity values and ratios for different matrix-materials analyzed, implying that matrix-matched external calibrations remain to be applied for their trace quantification. 展开更多
关键词 Copper Alloys Reference Material Matrix Effect In-Situ Metal Determinations NEAR-INFRARED Femtosecond laser ablation-inductively coupled plasma-mass spectrometry (NIR fs-LA-ICP-MS)
下载PDF
Elemental Quantitative Distribution and Statistical Analysis on Cross Section of Stainless Steel Sheet by Laser Ablation Inductively Coupled Plasma Mass Spectrometry 被引量:2
2
作者 Qian-hua LUO Hai-zhou WANG 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2015年第8期730-737,共8页
An innovative application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) technique in illustrating elemental distributions on stainless steel sheets was presented. The technique proved to... An innovative application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) technique in illustrating elemental distributions on stainless steel sheets was presented. The technique proved to be a systematic and accurate ap- proach in producing visual images or maps of elemental distributions at cross-sectional surface of a stainless steel sheet. Two stain- less steel sheets served as research objects: 3 mm×l 300 mm hot-rolled stainless steel plate and 1 mm×l 260 mm cold-rolled plate. The cross-sectional surfaces of the two samples at 1/4 position along the width direction were scanned (raster area -44 mm2 and 11 mm2) with a focused laser beam (wavelength 213 nm, diameter of laser crater 100 μm, and laser power 1.6 mJ) in a laser abla- tion chamber. The laser ablation system was coupled to a quadrupole ICP-MS, which made the detection of ion intensities of 27A1+, 44Ca+, 47Ti-, 55Mn+ and 56Fe+ within an area of interest possible. One-dimensional (ID) content line distribution maps and two- dimensional (2D) contour maps for specific positions or areas were plotted to indicate the element distribution of a target area with high accuracy. Statistic method was used to analyze the acquired data by calculating median contents, maximum segregation, sta- tistic segregation and content-frequency distribution. 展开更多
关键词 stainless steel sheet laser ablation inductively coupled plasma mass spectrometry elemental distribution statistic analysis
原文传递
激光剥蚀-扇形磁场电感耦合等离子体质谱法同时测定锆石U-Pb年龄和微量元素含量
3
作者 赵令浩 孙冬阳 +3 位作者 胡明月 袁继海 范晨子 詹秀春 《岩矿测试》 CAS CSCD 北大核心 2024年第1期47-62,共16页
激光剥蚀-扇形磁场电感耦合等离子体质谱(LA-SF-ICP-MS)具有高灵敏度特征,被广泛应用于锆石等含U矿物原位微区U-Pb定年研究,但磁偏转式质量分析器的使用导致该质谱仪扫描速度相对较慢,可能影响U-Pb同位素与其他关键微量元素的同时采集... 激光剥蚀-扇形磁场电感耦合等离子体质谱(LA-SF-ICP-MS)具有高灵敏度特征,被广泛应用于锆石等含U矿物原位微区U-Pb定年研究,但磁偏转式质量分析器的使用导致该质谱仪扫描速度相对较慢,可能影响U-Pb同位素与其他关键微量元素的同时采集。本文通过优化仪器信号稳定性和实验方法,对目前常用的7种锆石U-Pb标准样品进行U-Pb定年和Ti、REEs、Hf等关键元素同时定量分析,探讨了多元素同时分析方法的可行性及对于U-Pb定年结果的影响。实验结果表明,相对于LA-SF-ICP-MS仅检测U-Pb同位素方法,同时开展多元素含量检测可能会使U-Pb同位素信号强度稳定性下降,导致单点U-Pb年龄结果误差及离散程度增大。与仅测定U-Pb同位素年龄的测定结果相比较,根据不同锆石样品中U-Pb同位素含量高低,多元素同时检测获得分析点的206Pb/238U年龄和207Pb/235U年龄变化范围不同程度地增大,其中207Pb/235U年龄受影响明显,单点207Pb/235U年龄误差从~1.5%增大至~2.0%,单点年龄的相对标准偏差(RSD)从0.5%~1.3%增大至1.2%~3.3%。尽管如此,多元素同时检测方法对于各样品最终测定年龄没有明显的影响,相对于TIMS年龄,各样品的谐和年龄和206Pb/238U加权平均年龄偏差分别小于1.0%和0.7%,完全满足U-Pb同位素地质年代学测试要求。同时测定锆石样品中的关键微量元素含与其推荐值相对误差小于10%。因此,采用LA-SF-ICP-MS可以同时准确地测定锆石U-Pb年龄和微量元素含量,该方法亦可用于其他副矿物U-Pb年龄与关键微量元素同时测定。 展开更多
关键词 激光剥蚀-扇形磁场电感耦合等离子体质谱(LA-SF-ICP-MS) 锆石 U-PB定年 微量元素
下载PDF
松辽盆地砂岩型铀矿铀含量配分比例的半定量分析
4
作者 刘明义 吴柏林 +5 位作者 杨松林 郝欣 王苗 李琪 林周洋 张效瑞 《岩矿测试》 CAS CSCD 北大核心 2024年第2期224-233,共10页
钱家店铀矿是位于松辽盆地南部的复成因砂岩型铀矿,受表生淋滤、辉绿岩中低温热液和深部油气等多流体影响,目前铀矿物赋存状态尚有一定争议,铀在矿石内不同矿物中的配分尚不明确。为了进一步明确铀赋存状态和在不同矿物中的配分,计算钱... 钱家店铀矿是位于松辽盆地南部的复成因砂岩型铀矿,受表生淋滤、辉绿岩中低温热液和深部油气等多流体影响,目前铀矿物赋存状态尚有一定争议,铀在矿石内不同矿物中的配分尚不明确。为了进一步明确铀赋存状态和在不同矿物中的配分,计算钱家店矿石中不同矿物中铀的配分比例,本文运用岩矿鉴定、铀化学逐级提取、电子探针和激光剥蚀电感耦合等离子体质谱(LA-ICP-MS)微区原位分析技术开展综合测试分析。明确了钱家店铀矿物的赋存状态,认为钱家店铀矿物以吸附态为主,约占总铀含量的80%,结合态铀矿物或含铀矿物约占比20%。其中吸附态铀矿物主要富集在方解石等碳酸盐矿物中,占总铀含量的47.86%,其次是在黏土矿物中占17.94%,在铁锰氧化物矿物中占12.21%。独立铀矿物是与黄铁矿密切共生的沥青铀矿为主,约占铀总含量的9.07%,另有少量含钛铀矿物和铀石约占5.08%。这种矿石中各碎屑组分中铀的占比量化研究,为矿床地浸开采及资源量计算提供依据。 展开更多
关键词 铀赋存状态 原位 电子探针 激光剥蚀电感耦合等离子体质谱法 配分比例 钱家店铀矿 松辽盆地
下载PDF
基于质谱的单细胞分析技术研究新进展
5
作者 尤穆英楠 刘心昱 +1 位作者 石先哲 许国旺 《质谱学报》 EI CAS CSCD 北大核心 2024年第3期316-331,I0001,共17页
细胞是生物体最基本的结构和功能单位。近年来,人们对细胞异质性的关注越来越多。为了分析细胞的这种异质性,避免单细胞信息被群体细胞的平均值所淹没,单细胞分析技术不断发展起来。由于单细胞的体积小,内含物质含量低且种类繁多,某些... 细胞是生物体最基本的结构和功能单位。近年来,人们对细胞异质性的关注越来越多。为了分析细胞的这种异质性,避免单细胞信息被群体细胞的平均值所淹没,单细胞分析技术不断发展起来。由于单细胞的体积小,内含物质含量低且种类繁多,某些物质在细胞内的变化迅速,分析过程中不同物质之间相互干扰,造成了单细胞分析极具挑战性。基于质谱的单细胞分析技术具有通用性强、无需标记、高灵敏度、高分辨率、高选择性的优点,已逐渐在单细胞分析技术中脱颖而出,成为单细胞分析的理想工具。本文系统地总结了近5年来基于质谱的单细胞分析技术的最新进展,包括电喷雾电离质谱、激光解吸电离质谱、二次离子质谱、电感耦合等离子体质谱,并对未来的研究和技术方向进行展望,希望为单细胞质谱分析技术的研究提供参考。 展开更多
关键词 单细胞 电喷雾电离质谱(ESI-MS) 激光解吸电离质谱(LDI-MS) 二次离子质谱(SIMS) 电感耦合等离子体质谱(ICP-MS)
下载PDF
利用激光气流分割技术同时测定斜长石的微量元素与Sr同位素
6
作者 张磊 张乐 《地球化学》 CAS CSCD 北大核心 2023年第1期53-68,共16页
斜长石是火成岩中的主要造岩矿物之一。其微量元素和Sr同位素组成可以用来示踪多种地质过程。传统的斜长石研究需要进行2次独立的激光剥蚀电感耦合等离子体质谱分析,来分别测试微量元素和Sr同位素组成。然而对于具有复杂环带结构的斜长... 斜长石是火成岩中的主要造岩矿物之一。其微量元素和Sr同位素组成可以用来示踪多种地质过程。传统的斜长石研究需要进行2次独立的激光剥蚀电感耦合等离子体质谱分析,来分别测试微量元素和Sr同位素组成。然而对于具有复杂环带结构的斜长石, 2次激光剥蚀分析获得的微量元素和Sr同位素可能是解耦的。本研究采用近几年兴起的激光气流分割技术建立了通过1次激光剥蚀同时测试斜长石微量元素和Sr同位素的方法。该方法将1台激光剥蚀系统(LA)同时与1台高分辨率扇形磁场等离子体质谱(SF-ICP-MS)和1台多接收等离子体质谱(MC-ICP-MS)联机。在1次激光剥蚀过程中,通过Y形接头将激光剥蚀产生的气溶胶分为两路,一路气溶胶进入MC-ICP-MS进行同位素组成分析,另一路气溶胶进入SF-ICP-MS进行微量元素含量分析。使用本方法分析USGS玄武玻璃标样BHVO-2G和NKT-1G的Sr同位素组成和微量元素含量,分析结果在误差范围内均与推荐值或前人报道值一致。此外,本研究利用建立的方法对满洲里巴杨山塔木兰沟组火山岩中的斜长石斑晶进行了微量元素和Sr同位素的同时测试,并利用斜长石成分计算了平衡熔体的微量元素组成。分析认为,巴杨山玄武安山岩源区为俯冲板片流体交代过的岩石圈地幔,并在岩浆上升过程中发生了少量地壳混染作用。 展开更多
关键词 扇形磁场电感耦合等离子体质谱 多接收电感耦合等离子体质谱 激光气流分割技术 斜长石 微量元素 SR同位素
下载PDF
四酸密闭消解—电感耦合等离子体质谱(ICP-MS)法测定铀矿中的铼和钪 被引量:3
7
作者 贾雷 左修源 《中国无机分析化学》 CAS 北大核心 2023年第5期469-474,共6页
建立一种准确测定铀矿中铼和钪含量的方法,为铀矿中伴生元素的分析与研究提供数据支持,对探勘铼钪矿实现战略资源合理利用化有着重大意义。采用氢氟酸-硝酸-盐酸-高氯酸四酸作溶剂、密闭聚四氟乙烯坩埚-电热板加热方式溶解样品,利用电... 建立一种准确测定铀矿中铼和钪含量的方法,为铀矿中伴生元素的分析与研究提供数据支持,对探勘铼钪矿实现战略资源合理利用化有着重大意义。采用氢氟酸-硝酸-盐酸-高氯酸四酸作溶剂、密闭聚四氟乙烯坩埚-电热板加热方式溶解样品,利用电感耦合等离子体质谱(ICP-MS)法测定铀矿中铼和钪。通过探讨分解方法、称样量、酸用量、溶样温度及时间、基体干扰、内标选择的影响。结果表明,酸溶分解结果准确性高于碱熔分解,3 mL HF、4 mL HNO3、2 mL HCl和1 mL HClO4为最佳消解体系,0.05~0.10 g、10~12 mL为最佳称样量和酸用量,闭盖160℃、开盖190℃18 h为最佳溶样条件,选择碰撞气流速为3.0 mL/min,稀释气流速为0.8 L/min降低基体干扰,In作为内标能够达到测试要求。方法操作简单,其中铼和钪的检出限分别为0.002和0.122 mg/kg;铼准确度在92.9%~98.4%,相对标准偏差在2.4%~5.7%;钪准确度在93.5%~98.2%,相对标准偏差在1.6%~6.2%;铼加标回收率为87.2%~93.8%,钪加标回收率为90.7%~92.3%,检出限低,精密度良好,满足铀矿中铼和钪的分析要求。 展开更多
关键词 铀矿 四酸密闭消解 电感耦合等离子体质谱(ICP-MS)
下载PDF
Mg/Ca,Ba/Ca,and S/Ca ratios as environmental and growth proxies for bivalve shells from the Haima cold seep,South China Sea
8
作者 Jingya CAO Shengxiong YANG +2 位作者 Danling TANG Junxi FENG Jinqiang LIANG 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2023年第2期660-672,共13页
Bivalve shell fossils,cemented by authigenic carbonates,are widely spread in the Haima cold seep,Qiongdongnan Basin of the South China Sea(SCS).In this study,we examined an element profile of Gigantidas platifrons in ... Bivalve shell fossils,cemented by authigenic carbonates,are widely spread in the Haima cold seep,Qiongdongnan Basin of the South China Sea(SCS).In this study,we examined an element profile of Gigantidas platifrons in the Haima cold seeps at a water depth of 1381 m.Based on the scanning electron microscope(SEM)analyses,the prismatic layer and nacreous layer were identified,which are characterized by prismatic structure and stratified structure,respectively.In addition,the profile can be subdivided into two parts:altered and unaltered zones.Laser inductively coupled plasma mass spectrometry(LA-ICP-MS)mapping shows that the element concentrations of the altered zones were influenced by the authigenic carbonate rocks,whereas the element concentrations of unaltered zones remain stable.In-situ X-ray diffraction(XRD)analyses show that the mineral constituent of the prismatic layer is mainly composed of aragonite.Along with the growth profile,Mg/Ca ratios of unaltered zones have minor variations,ranging 0.72-0.97 mmol/mol(mean=0.87 mmol/mol),with estimated temperatures of 3.8-4.1℃,indicating that the temperature of the surrounding seawater remains constant and agree with the measured data of 3.9℃which was conducted by a conductivity-temperature-depth system(CTD).The minor variations of Ba/Ca ratios(0.01-0.06 mmol/mol;mean=0.04 mmol/mol)indicate a relatively stabilized salinity of the surrounding seawater.S/Ca ratios show large variations of 0.04-4.15 mmol/mol(mean=1.37 mmol/mol).S/Ca ratios have regular variations which generally correspond to the variations of the Mg/Ca ratios,highlighting that the S/Ca ratios of bivalve shells show the potential to reflect the growth rate of the Gigantides.However,further studies should be carried out on the understanding of the links between the S/Ca ratios and seepage intensity of cold-seep fluids. 展开更多
关键词 Mg/Ca Ba/Ca and S/Ca ratios laser inductively coupled plasma mass spectrometry(LA-ICPMS) Gigantidas platifrons Haima cold seep South China Sea
下载PDF
激光剥蚀电感耦合等离子体质谱微区分析新进展 被引量:36
9
作者 罗彦 胡圣虹 +2 位作者 刘勇胜 高山 林守麟 《分析化学》 SCIE EI CAS CSCD 北大核心 2001年第11期1345-1352,共8页
从仪器、基础研究诸方面评述近年来LA ICP MS微区分析进展 ,重点介绍了与ICP MS联用的激光技术发展、校正方法、分馏效应、剥蚀颗粒分布研究及仪器装置与实验技术改进 ,对LA ICP MS技术的应用作了回顾与展望。引用文献
关键词 激光剥蚀 电感耦合等离子体质谱 微区分析 色谱 质谱 联用技术
下载PDF
基体归一定量技术在激光烧蚀-等离子体质谱法锆石原位多元素分析中的应用 被引量:56
10
作者 胡明月 何红蓼 +3 位作者 詹秀春 樊兴涛 王广 贾泽荣 《分析化学》 SCIE EI CAS CSCD 北大核心 2008年第7期947-953,共7页
探讨了内标法和基体归一法校准的基本原理。基体归一校准法的基本步骤为:先用简单外标法测得样品中尽可能全的主、次、痕量元素含量,氧化物加和后进行100%归一,得到灵敏度校正系数,对所有元素的测定结果进行修正。修正结果的可靠性在很... 探讨了内标法和基体归一法校准的基本原理。基体归一校准法的基本步骤为:先用简单外标法测得样品中尽可能全的主、次、痕量元素含量,氧化物加和后进行100%归一,得到灵敏度校正系数,对所有元素的测定结果进行修正。修正结果的可靠性在很大程度上取决于测定元素是否"完全"。由于锆石的基体元素组成简单且易于测定,很适合用基体归一法校准。在激光剥蚀-电感耦合等离子体质谱法(LA-ICP-MS)微区原位分析中,应用基体归一校准法的最大优点是:可以避免预先用其它微区分析技术对未知样品中的内标元素进行定量。该技术可适用于具有环带结构、难以找到均匀分布的内标元素的地质样品的元素空间分布测定。在高分辨ICP-MS(Element2)和NewWave-UV-213激光系统上,应用基体归一定量技术同时分析了锆石中主、次、痕量共54种元素。对未知锆石样品的分析,基体归一法与内标法结果的一致性令人满意。分析德国蛇纹岩标准玻璃ATHO-G中相对误差<25%的有52个元素,<10%的有36个元素;大多数元素的相对标准偏差<10%。 展开更多
关键词 激光剥蚀-电感耦合等离子体质谱法(LA-ICP-MS) 原位微区分析 基体归一校准法 锆石
下载PDF
激光探针等离子体质谱法(LAM-ICPMS)用于年轻锆石U-Pb定年 被引量:41
11
作者 梁细荣 李献华 +2 位作者 刘永康 朱炳泉 张海祥 《地球化学》 CAS CSCD 北大核心 2000年第1期1-5,共5页
利用激光探针等离子体质谱(LAM-ICPMS)技术对中生代钻石进行了详细的206Pb/23U定年研究。采用线扫描(Linescan)进样法减小了传统的剥深(Depthprofile)进样法所引起的激光熔蚀分异效应;优化仪器参数可消减ICP-MS对Pb和U的质量... 利用激光探针等离子体质谱(LAM-ICPMS)技术对中生代钻石进行了详细的206Pb/23U定年研究。采用线扫描(Linescan)进样法减小了传统的剥深(Depthprofile)进样法所引起的激光熔蚀分异效应;优化仪器参数可消减ICP-MS对Pb和U的质量歧视效应;测得了精确的206Pb/238U比值及年龄。研究结果表明,均匀颗粒锆石的206Ph/238U比值测量精度为2%~10%,定年精度和准确度优于3%;对大颗粒(100~160μm)及均匀的年轻锆石U-Pb定年可与灵敏的高分辨离子探针(SHRIMP)定年结果相比。 展开更多
关键词 激光探针 等离子体质谱 锆石 铀-铅定年
下载PDF
激光探针等离子体质谱同时测定锆石微区铀-铅年龄及微量元素 被引量:30
12
作者 梁细荣 李献华 +2 位作者 刘永康 刘颖 王甘霖 《岩矿测试》 CAS CSCD 北大核心 1999年第4期253-258,共6页
建立了一种利用激光探针等离子体质谱技术同时原位测定锆石Pb- Pb 及Pb - U 年龄和25 个微量元素的快速分析方法。P 的检出限为14 μg/g ,Sc 的检出限为3 μg/ g,Rb、Nb、Ba 及稀土元素Nd 、Gd 、... 建立了一种利用激光探针等离子体质谱技术同时原位测定锆石Pb- Pb 及Pb - U 年龄和25 个微量元素的快速分析方法。P 的检出限为14 μg/g ,Sc 的检出限为3 μg/ g,Rb、Nb、Ba 及稀土元素Nd 、Gd 、Dy、Er 及Yb 的检出限为0 .1 ~0 .3 μg/g ,Pb 的检出限0 .5 μg/g ,其它稀土元素及Sr、Y、Hf 、Ta 、Th 和U 的检出限为10 ~90 ng/ g 。方法对绝大多数微量元素的相对标准偏差为5 % ~15 % ;207Pb/206Pb 比值的测量精度为1 % ~3 % ,206Pb/238 U 比值的测量精度为2 %~10 % 。 展开更多
关键词 激光探针 等离子体质谱 锆石 微量元素 铀铅年龄
下载PDF
单个流体包裹体元素化学组成分析新技术——激光剥蚀电感耦合等离子体质谱(LA-ICP-MS) 被引量:23
13
作者 胡圣虹 胡兆初 +3 位作者 刘勇胜 罗彦 林守麟 高山 《地学前缘》 EI CAS CSCD 2001年第4期434-440,共7页
高灵敏度、高精密度、低检出限、多元素同时检测并可提供同位素组成比值信息的等离子体质谱与高空间分辨率的紫外激光采样技术结合 ,可定量地测定单个流体包裹体中常、微量元素含量 ,为成矿流体的研究提供了一个新的研究手段。文中简要... 高灵敏度、高精密度、低检出限、多元素同时检测并可提供同位素组成比值信息的等离子体质谱与高空间分辨率的紫外激光采样技术结合 ,可定量地测定单个流体包裹体中常、微量元素含量 ,为成矿流体的研究提供了一个新的研究手段。文中简要地介绍了激光剥蚀电感耦合等离子体质谱 (LA ICP MS)分析仪器的发展 ,结合实验室的研究工作 ,就激光剥蚀池的设计、单个流体包裹体的剥蚀方法、元素的分馏效率、定量校正技术及其在成矿成因物理化学机制研究中的应用等进行评述 ,并阐述单个流体包裹体元素组成的LA ICP MS分析技术存在的局限和发展趋势。 展开更多
关键词 激光剥蚀电感耦合等离子体质谱 流体包裹体 微量元素 分馏效率 流体作用 成矿流体 剥蚀方法
下载PDF
激光剥蚀ICP-MS法测定盐类矿物单个流体包裹体的成分 被引量:20
14
作者 孙小虹 胡明月 +4 位作者 刘成林 焦鹏程 马黎春 王鑫 詹秀春 《分析化学》 SCIE EI CAS CSCD 北大核心 2013年第2期235-241,共7页
采用纯石英毛细管人工流体包裹体作为校准样品,通过对系列人工流体包裹体激光剥蚀电感耦合等离子体质谱(LA-ICP-MS)测试分析,初步建立了LA-ICP-MS分析盐类矿物单个流体包裹体化学组成的分析方法流程以及包裹体中8种常见元素K,Ca,Mg,Sr,R... 采用纯石英毛细管人工流体包裹体作为校准样品,通过对系列人工流体包裹体激光剥蚀电感耦合等离子体质谱(LA-ICP-MS)测试分析,初步建立了LA-ICP-MS分析盐类矿物单个流体包裹体化学组成的分析方法流程以及包裹体中8种常见元素K,Ca,Mg,Sr,Rb,B,Li和Br的校准曲线。其中,K,Ca,Mg,Sr,Rb和Li的校准曲线的相关系数R2>0.9991;相对标准偏差为0.1%~6.2%;B和Br的校准曲线的相关系数R2稍低,分别为0.9910和0.9618;相对标准偏差4.1%~29.6%。校准曲线结果表明,建立的盐类矿物单个流体包裹体原位ICP-MS多元素定量分析方法是可行的,并且是较准确的。本方法简便、快速、灵敏度高。运用本方法对新疆罗布泊石盐和石膏矿物流体包裹体进行了测试,取得了满意的结果。 展开更多
关键词 激光剥蚀ICP-MS 流体包裹体 盐类矿物 石盐 石膏
下载PDF
锆石铀-铅定年激光剥蚀-电感耦合等离子体质谱原位微区分析进展 被引量:36
15
作者 范晨子 胡明月 +2 位作者 赵令浩 孙冬阳 詹秀春 《岩矿测试》 CAS CSCD 北大核心 2012年第1期29-46,共18页
激光剥蚀-电感耦合等离子体质谱(LA-ICP-MS)技术是目前最常用的锆石U-Pb同位素年龄测定方法之一。该方法能够对单颗粒锆石内部年龄差异实现快速、准确的原位微区分析。文章总结了近年来激光剥蚀系统、ICP-MS技术以及LA-ICP-MS锆石U-Pb... 激光剥蚀-电感耦合等离子体质谱(LA-ICP-MS)技术是目前最常用的锆石U-Pb同位素年龄测定方法之一。该方法能够对单颗粒锆石内部年龄差异实现快速、准确的原位微区分析。文章总结了近年来激光剥蚀系统、ICP-MS技术以及LA-ICP-MS锆石U-Pb定年方法、相关应用实例研究的进展和现状。系统评述了激光发生器,剥蚀池,剥蚀参数(激光波长、脉冲宽度、剥蚀气体、孔径大小)以及四极杆和扇形磁场质谱仪对锆石U-Pb年龄数据的精度和准确度的影响。详细介绍了基于锆石年龄标准样品、标准溶液及其他标样的外标定量校准方法,单个U/Pb比值计算方法,普通铅校正方法以及同位素年龄与微量元素同时测定的方法。目前LA-ICP-MS锆石U-Pb定年技术主要应用于碎屑锆石的沉积物源区示踪和岩浆事件的年代学约束研究。 展开更多
关键词 锆石 铀-铅定年 激光剥蚀-等离子体质谱 原位微区分析
下载PDF
激光剥蚀电感耦合等离子体质谱微区分析进展评述 被引量:19
16
作者 王岚 杨理勤 +3 位作者 王亚平 冯亮 陈雪 陈占生 《地质通报》 CAS CSCD 北大核心 2012年第4期637-645,共9页
激光剥蚀电感耦合(LA-ICP-MS)等离子体以其高空间分辨率、高灵敏度、多元素同时测定并可提供同位素比值信息的检测能力在原位微区分析中已得到广泛应用。现从仪器的发展、基础研究等方面评述了近年来LA-ICP-MS微区分析的进展,重点介绍... 激光剥蚀电感耦合(LA-ICP-MS)等离子体以其高空间分辨率、高灵敏度、多元素同时测定并可提供同位素比值信息的检测能力在原位微区分析中已得到广泛应用。现从仪器的发展、基础研究等方面评述了近年来LA-ICP-MS微区分析的进展,重点介绍了与等离子体质谱(ICP-MS)联用的激光器(纳秒和飞秒激光器)的发展、校正方法、分馏效应及其在地球科学微量元素、同位素、包裹体分析中的应用。并简要地阐述了LA-ICP-MS分析技术存在的局限和发展趋势。 展开更多
关键词 激光剥蚀电感耦合等离子体(LA-ICP-MS) 微区分析 地球科学 评述
下载PDF
电感耦合等离子体质谱仪与激光器联用测量条件优化及其在锆石U-Pb定年中的应用 被引量:31
17
作者 李凤春 侯明兰 +5 位作者 栾日坚 林培军 李增胜 赵龙 王继林 徐爽 《岩矿测试》 CAS CSCD 北大核心 2016年第1期17-23,共7页
在LA-ICP-MS测量中,样品是否能够均匀地由激光样品池运送到等离子体质谱仪炬管是影响分析数据精度的关键。本研究对样品剥蚀池和剥蚀气溶胶传输进行改进,在LA和ICP-MS之间添加一套激光剥蚀脉冲平滑系统将LA剥蚀气溶胶转化为连续送样模式... 在LA-ICP-MS测量中,样品是否能够均匀地由激光样品池运送到等离子体质谱仪炬管是影响分析数据精度的关键。本研究对样品剥蚀池和剥蚀气溶胶传输进行改进,在LA和ICP-MS之间添加一套激光剥蚀脉冲平滑系统将LA剥蚀气溶胶转化为连续送样模式,并使用多通道旋转式样品池消除样品在激光剥蚀池中的位置效应,显著提高了测量信号的稳定性。在优化条件下,以标准锆石91500作外标,测量锆石标样GJ-1、Pleovice、TEMORA、QH的U-Pb年龄分别为604±3 Ma(2δ,MSWD=1.2)、337±1 Ma(2δ,MSWD=1.18)、419±3 Ma(2δ,MSWD=0.15)和161±1 Ma(2δ,MSWD=0.6),与前人报道结果在误差范围内一致;以NIST610作外标,玻璃标样NIST612和BHVO-2G大部分微量稀土元素的测量值与参考值的相对偏差均在10%以内;测量新疆天山造山带锆石样品的207Pb/206Pb加权年龄与SHRIMP结果基本吻合。本方法可有效降低元素分馏效应,提高测量精度。 展开更多
关键词 激光剥蚀电感耦合等离子体质谱 测量数据稳定性 多通道旋转式样品池 激光剥蚀脉冲平滑系统
下载PDF
激光烧蚀-电感耦合等离子体质谱技术在材料表面微区分析领域的应用进展 被引量:13
18
作者 张勇 贾云海 +8 位作者 陈吉文 沈学静 刘英 赵雷 李冬玲 韩鹏程 赵振 樊万伦 王海舟 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2014年第8期2238-2243,共6页
激光烧蚀-电感耦合等离子体质谱(LA-ICP-MS)技术不仅可以对导体及非导体进行元素的成分含量分析,而且还可进行元素分布及涂层深度表面微区分析,故在元素分析领域引起广泛的关注。主要介绍了LA-ICP-MS的仪器装置及其表面微区分析理论,同... 激光烧蚀-电感耦合等离子体质谱(LA-ICP-MS)技术不仅可以对导体及非导体进行元素的成分含量分析,而且还可进行元素分布及涂层深度表面微区分析,故在元素分析领域引起广泛的关注。主要介绍了LA-ICP-MS的仪器装置及其表面微区分析理论,同时对LA-ICP-MS在钢铁、有色金属及半导体等材料科学领域中的元素分布及涂层深度表面微区分析应用进展情况进行回顾,与SEM/EDS(扫描电子显微镜/能谱仪)、EPMA(电子探针微区分析)、AES(俄歇电子能谱)等传统经典的表面分析方法的比较,LA-ICP-MS具有无需或很少样品制备、空间分辨率可调、多元素同时分析及灵敏度高等优点,目前LA-ICP-MS已成为这些经典表面微区分析工具强有力的补充。随着LA-ICP-MS分析技术进一步的发展与成熟,相信不久的将来越来越多的元素分析工作者会使用这一强有力的分析工具,它像LIBS(激光诱导击穿光谱)一样,将会成为元素分析领域非常耀眼的一颗新星。 展开更多
关键词 激光烧蚀 电感耦合等离子体质谱仪(ICP/MS) 材料科学 表面微区分析
下载PDF
激光剥蚀等离子体质谱分析中激光剥蚀参数对信号响应的影响 被引量:13
19
作者 徐鸿志 靳兰兰 +2 位作者 李爱荣 帅琴 胡圣虹 《岩矿测试》 CAS CSCD 2005年第3期171-175,共5页
探讨了激光剥蚀等离子体质谱固体微区分析中激光剥蚀参数对元素分析信号灵敏度及稳定性的影响.这些参数包括激光功率、脉冲频率、剥蚀孔经、散焦距离、剥蚀方式等.讨论了优化的激光剥蚀等离子体质谱信号采集及数据处理方式.在全质量范... 探讨了激光剥蚀等离子体质谱固体微区分析中激光剥蚀参数对元素分析信号灵敏度及稳定性的影响.这些参数包括激光功率、脉冲频率、剥蚀孔经、散焦距离、剥蚀方式等.讨论了优化的激光剥蚀等离子体质谱信号采集及数据处理方式.在全质量范围内选用具有代表性的元素作为研究对象,建立了激光剥蚀的一般性特征规律和266 nm紫外激光系统的最佳操作条件.在选定的激光剥蚀参数下,大多数被测元素的检出限为22.8~457 ng/g,能够满足固体微区分析的要求. 展开更多
关键词 激光剥蚀 等离子体质谱 微区分析 操作参数
下载PDF
激光剥蚀电感耦合等离子体质谱法测定碳化硅器件中杂质元素 被引量:14
20
作者 周慧 汪正 +6 位作者 朱燕 李青 陈奕睿 屈海云 邹慧君 杜一平 胡慧廉 《分析化学》 SCIE EI CAS CSCD 北大核心 2014年第1期123-126,共4页
采用激光剥蚀电感耦合等离子体质谱法(LA—ICP—MS),以NIST玻璃标准物质制作校准曲线,^29Si为内标,相对灵敏度因子(RSF)校准标样和样品间的基体效应,对碳化硅陶瓷器件中9种痕量元素(B,Ti,Cr,Mn,Fe和Ni等)进行定量测定。... 采用激光剥蚀电感耦合等离子体质谱法(LA—ICP—MS),以NIST玻璃标准物质制作校准曲线,^29Si为内标,相对灵敏度因子(RSF)校准标样和样品间的基体效应,对碳化硅陶瓷器件中9种痕量元素(B,Ti,Cr,Mn,Fe和Ni等)进行定量测定。选择线性扫描方式,激光剥蚀孔径为150μm,氦气和氩气流量为0.7L/min时,信号稳定性和灵敏度最佳。经内标校准后,各元素标准曲线的线性有较大改善,线性相关系数为0.9981~0.9999。以建立的方法对碳化硅标准参考物质(BAM—S003)中的痕量元素进行测定,并与标准参考值进行对比,结果一致,证实了LA—ICP.MS方法应用于碳化硅样品检测的准确性和有效性。采用本方法定量测定碳化硅器件中痕量元素,结果与辉光放电质谱法(GD—MS)测定的结果比较一致。元素B,Ti,Cr,Mn,Fe,Ni,Cu,Sr和La的检出限为0.004~0.08mg/kg,相对标准偏差(RSD)小于5%。 展开更多
关键词 激光剥蚀 电感耦合等离子体质谱 碳化硅
下载PDF
上一页 1 2 9 下一页 到第
使用帮助 返回顶部