In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferome...In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferometer based on cat’s eye and confocal method. Through analyzing the error source models of radius of curvature testing, optical configuration of the testing device has been optimized. Precise environment control and real-time monitoring system is also established to reduce the errors caused by environment. Through the above processes, the radius of curvature measurement relative accuracy is better than 2 ppm. One optical sphere, R88.5 mm, test aperture 59 mm, has been tested. Testing result is 88499.465 ± 0.176 μm, meeting the design requirement. The method has high accuracy and practical advantages.展开更多
In this paper, we propose and demonstrate an adjustable-free and movable Nd:YVO_(4)thin disk laser based on the telecentric cat’s eye cavity. We design a V-shaped laser cavity containing two reflectors with Nd:YVO_(4...In this paper, we propose and demonstrate an adjustable-free and movable Nd:YVO_(4)thin disk laser based on the telecentric cat’s eye cavity. We design a V-shaped laser cavity containing two reflectors with Nd:YVO_(4)thin disks as the gain medium.The experimental results from the traditional plane-plane cavity, plane-telecentric cat’s eye cavity, and double telecentric cat’s eye cavity are compared. They show that plane-telecentric cat’s eye cavity laser can keep operating at the adjustablefree range of -6° to +6°, which is up to 60 times better than that of traditional plane-plane cavity. In the double telecentric cat’s eye case, the adjustable-free range is improved to-13° to +13°. Additionally, in the case of the double telecentric cat’s eye cavity, the output telecentric cat’s eye can achieve free movement within the horizontal range of ±20 mm.展开更多
文摘In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferometer based on cat’s eye and confocal method. Through analyzing the error source models of radius of curvature testing, optical configuration of the testing device has been optimized. Precise environment control and real-time monitoring system is also established to reduce the errors caused by environment. Through the above processes, the radius of curvature measurement relative accuracy is better than 2 ppm. One optical sphere, R88.5 mm, test aperture 59 mm, has been tested. Testing result is 88499.465 ± 0.176 μm, meeting the design requirement. The method has high accuracy and practical advantages.
基金This work was supported by the National Natural Science Foundation of China(NSFC)(Nos.61775223 and 11974367)Strategic Priority Research Program of Chinese Academy of Sciences(No.XDB1603)Shanghai Science and Technology Innovation Action Plan Project(No.19142202500)。
文摘In this paper, we propose and demonstrate an adjustable-free and movable Nd:YVO_(4)thin disk laser based on the telecentric cat’s eye cavity. We design a V-shaped laser cavity containing two reflectors with Nd:YVO_(4)thin disks as the gain medium.The experimental results from the traditional plane-plane cavity, plane-telecentric cat’s eye cavity, and double telecentric cat’s eye cavity are compared. They show that plane-telecentric cat’s eye cavity laser can keep operating at the adjustablefree range of -6° to +6°, which is up to 60 times better than that of traditional plane-plane cavity. In the double telecentric cat’s eye case, the adjustable-free range is improved to-13° to +13°. Additionally, in the case of the double telecentric cat’s eye cavity, the output telecentric cat’s eye can achieve free movement within the horizontal range of ±20 mm.