With more than 30 years of development,laser-induced fluorescence(LIF)is becoming an increasingly common diagnostic to measure ion and neutral velocity distribution functions in different fields of studies in plasma s...With more than 30 years of development,laser-induced fluorescence(LIF)is becoming an increasingly common diagnostic to measure ion and neutral velocity distribution functions in different fields of studies in plasma science including Hall thrusters,linear devices,plasma processing,and basic plasma physical processes.In this paper,technical methods used in the LIF diagnostic,including modulation,collection optics,and wavelength calibration techniques are reviewed in detail.A few basic physical processes along with applications and future development associated with the LIF diagnostics are also reviewed.展开更多
An accurate and reasonable technique combining direct absorption spectroscopy and laser-induced fluorescence(LIF)methods is developed to quantitatively measure the concentrations of hydroxyl in CH;/air flat laminar ...An accurate and reasonable technique combining direct absorption spectroscopy and laser-induced fluorescence(LIF)methods is developed to quantitatively measure the concentrations of hydroxyl in CH;/air flat laminar flame. In our approach, particular attention is paid to the linear laser-induced fluorescence and absorption processes, and experimental details as well. Through measuring the temperature, LIF signal distribution and integrated absorption, spatially absolute OH concentrations profiles are successfully resolved. These experimental results are then compared with the numerical simulation. It is proved that the good quality of the results implies that this method is suitable for calibrating the OH-PLIF measurement in a practical combustor.展开更多
The one-dimensional (1D) spatial distributions of OH absolute concentration in methane/air laminar premixed flat flame under different equivalence ratios at atmospheric pressure are investigated by using bi-directio...The one-dimensional (1D) spatial distributions of OH absolute concentration in methane/air laminar premixed flat flame under different equivalence ratios at atmospheric pressure are investigated by using bi-directional laser-induced flu- orescence (LIF) detection scheme combined with the direct absorption spectroscopy. The effective peak absorption cross section and the average temperature at a height of 2 mm above the burner are obtained by exciting absorption on the Q1(8) rotational line in the A2∑+ (Dt = 0) ←- X2∏ (v = 0) at 309.240 nm. The measured values are 1.86×10-15 cm2 and 1719 K, respectively. Spatial filtering and frequency filtering methods of reducing noise are used to deal with the experi- mental data, and the smoothing effects are also compared using the two methods. The spatial distribution regularities of OH concentration are obtained with the equivalence ratios ranging from 0.8 to 1.3. The spatial resolution of the measured result is 84μm. Finally, a comparison is made between the experimental result of this paper and other relevant study results.展开更多
A combined detection system involving simultaneous LIF and contacfless-conductometric measurements at the same place of the microfluidic chip was described. The LIF measurement was designed according to the confocal p...A combined detection system involving simultaneous LIF and contacfless-conductometric measurements at the same place of the microfluidic chip was described. The LIF measurement was designed according to the confocal principle and a moveable contactless-conduetivity detector was used in C^4D. Both measurements were mutually independent and advantageous in analyses of mixtures. Various experimental parameters affecting the response were examined and optimized. The performances were demonstrated by simultaneous detection of Rhodamine B. And the results showed that the combined detection system could be used sensitively and reliably.展开更多
The aim of the present work is to quantitatively measure the hydroxyl radical concentration by using LIF(laserinduced fluorescence) in flame.The detailed physical models of spectral absorption lineshape broadening,c...The aim of the present work is to quantitatively measure the hydroxyl radical concentration by using LIF(laserinduced fluorescence) in flame.The detailed physical models of spectral absorption lineshape broadening,collisional transition and quenching at elevated pressure are built.The fine energy level structure of the OH molecule is illustrated to understand the process with laser-induced fluorescence emission and others in the case without radiation,which include collisional quenching,rotational energy transfer(RET),and vibrational energy transfer(VET).Based on these,some numerical results are achieved by simulations in order to evaluate the fluorescence yield at elevated pressure.These results are useful for understanding the real physical processes in OH-LIF technique and finding a way to calibrate the signal for quantitative measurement of OH concentration in a practical combustor.展开更多
The absolute number density of nitrogen dioxide(NO2) seeded in argon is measured with cavity-enhanced laserinduced fluorescence(CELIF) through using a pulsed laser beam for the first time. The cavity ring down(CR...The absolute number density of nitrogen dioxide(NO2) seeded in argon is measured with cavity-enhanced laserinduced fluorescence(CELIF) through using a pulsed laser beam for the first time. The cavity ring down(CRD) signal is acquired simultaneously and used for normalizing the LIF signal and determining the relationship between the measured CELIF signal and the NO2 number density. The minimum detectable NO2 density down to(3.6±0.1)10^8 cm^-3 is measured in 60 s of acquisition time by the CELIF method. The minimum absorption coefficient is measured to be(2.0±0.1)10^-9 cm^-1, corresponding to a noise equivalent absorption sensitivity of(2.2±0.1)10^9 cm.^-1Hz^-1/2. The experimental system demonstrated here can be further improved in its sensitivity and used for environmental monitoring of outdoor NO2 pollution.展开更多
Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(Ⅲ...Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(Ⅲ) 3d4F7/2 to 4p4D0 5/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.展开更多
A new laser induced fluorescence imaging system used for detecting and locating the petroleum pollutants is presented. A unique feature of the system was using a combination of a frequency tripled Nd:YAG pulse laser ...A new laser induced fluorescence imaging system used for detecting and locating the petroleum pollutants is presented. A unique feature of the system was using a combination of a frequency tripled Nd:YAG pulse laser and an image intensified CCD camera as imaging detector. The delay time of the system and the exposure time of the CCD are controlled by a delay generator. Petroleum pollutants on various backgrounds had been detected and located by this system. This imaging technique provides a useful noninvasive approach for the detection of petroleum pollutants, which can be used in remote sensing.展开更多
cis-1,3,4,6-Tetranitrooctahydroimidazo-[4,5 d]imidazole(BCHMX)is an advanced energetic compound that expected to spread worldwide in the near future.Since,no approved remote detection methods were reported in current ...cis-1,3,4,6-Tetranitrooctahydroimidazo-[4,5 d]imidazole(BCHMX)is an advanced energetic compound that expected to spread worldwide in the near future.Since,no approved remote detection methods were reported in current literature for this material,we performed hyper-spectral imaging and laser induced fluorescence(LIF)to a BCHMX sample under low laser fluence for determining the optimum laser wavelength used in any future BCHMX-LIF based remote detection systems.For this purpose,an experimental setup consisted of a sun spectrum lamp and hyper-spectral camera was built to illuminate and image white powder samples of BCHMX in comparison with the traditional explosives,HMX(1,3,5,7-tetranitro-1,3,5,7-tetraazacyclooctane),RDX(1,3,5-trinitro-1,3,5-triazacyclohexane),PETN(2,2-Bis[(nitroxy)methyl]propane-1,3-diyldinitrate).The imaging reveals strong BCHMX sample absorption contrast among other samples at wavelength ranging from 400 to 410 nm.When light source was replaced by a 405 nm laser diode illuminator,a strong BCHMX sample LIF at the spectral range from 425 to 700 nm was observed under low laser fluence condition of 0.1 mJ/cm^(2).Finally,we demonstrated successfully the ability of the 405 nm LIF and the hyperspectral imaging technique to detect finger print traces of BCHMX on white cellulose fabric from a distance of 15 m and a detection limit of 1 mg/cm^(2).展开更多
High resolution laser induced fluorescence, spectra of IrN in the spectral region between 394 and 520 nm were recorded using laser vaporization/reaction free jet expansion and laser induced fluorescence spectroscopy. ...High resolution laser induced fluorescence, spectra of IrN in the spectral region between 394 and 520 nm were recorded using laser vaporization/reaction free jet expansion and laser induced fluorescence spectroscopy. Seven new vibronic transition bands were observed and analyzed. Two Ω=1 and five Ω=0 new states were identified. Least squares fit of rotationally resolved transition lines yielded accurate molecular constants for the upper states. Spectra of isotopic molecules were observed, which provided confirmation for the vibrational assignment. Comparison of the observed electronic states of IrB, IrC, and IrN provides a good understanding of the chemical bonding of this group of molecules.展开更多
The characteristics such as signal noise ratio(SNR) and sensitivity of the fluorescence detection system for micro-fluidic chip influence the performance of the whole system extremely. The confocal laser induced flu...The characteristics such as signal noise ratio(SNR) and sensitivity of the fluorescence detection system for micro-fluidic chip influence the performance of the whole system extremely. The confocal laser induced fluorescence detection system is presented. Based on the debugging of optical and circuit modules, the results of detecting the samples are given and analyzed theoretically, and the improved project is put forward.展开更多
N-Conjugated antigen was synthesized and polyclonal antibody with high specificity was obtained from immunizing animals. With this polyclonal antibody, a rapid and efficient CEIA-LIF method was developed to determine ...N-Conjugated antigen was synthesized and polyclonal antibody with high specificity was obtained from immunizing animals. With this polyclonal antibody, a rapid and efficient CEIA-LIF method was developed to determine the free morphine in urine of abusers. The detection limit was calculated to be 40 ng/mL. Simulated urine samples were analyzed with good recoveries, which showed the feasibility of its application in specific morphine determination in urine of morphine abusers.展开更多
A novel approach for analysis of amino acids in individual erythrocytes was established. In this method, the derivatization reagent was introduced into the living cells by electroporation. After derivatization, the am...A novel approach for analysis of amino acids in individual erythrocytes was established. In this method, the derivatization reagent was introduced into the living cells by electroporation. After derivatization, the amino acids in a single cell were determined by capillary electrophoresis with laser-induced fluorescence detection.展开更多
The main goal of this work was to quantify the detection of colistin at low levels in urine samples through the practical application of mixed surfactant micellar electrokinetic chromatography–laser-induced fluoresce...The main goal of this work was to quantify the detection of colistin at low levels in urine samples through the practical application of mixed surfactant micellar electrokinetic chromatography–laser-induced fluorescence (MEKC-LIF) analysis method using its advantage of sensitivity and to examine direct injection of biological samples. Colistin (po- lymyxin E) has neither strong UV chromophore nor fluorophore. So, its assay for metabolism, pharmacokinetics studies for bioavailability and bioequivalence are difficult because of poor detectability. Therefore an enhanced UV or fluores-cence detection by chemical derivatization is required. MEKC-LIF method was proposed for colistin with a 488/520 nm argon-ion laser using a pre-CE derivatization with fluorescein isothiocyanate (FITC). Borate buffer was used as background buffer (BGB). The different parameters affecting the proposed derivatization reaction including concentration of the derivatizing reagent, reaction time and temperature were studied and optimized. The derivative was stable for up to 3 days. Different micelles (TX-100 and SDS) were examined as BGB additives separately but negative-charged mixed micelles (SDS/TX-100) were shown to be the best additive to BGB for the analysis of colistin particularly in human urine as they enhance both selectivity and sensitivity of the proposed method. BGB was used with pH 9.5, 10 kV, 8 s inj time, capillary length 75 cm × 75 μm ID (66 cm effective length), detection was LIF Ex 488 nm;Em 520 nm. The method was applied to colistin analysis in human urine and the recovery was > 98% (n = 5). LOD and LOQ in urine after pre-column derivatization using FITC were 100 and 250 ng/ml, respectively. Urine samples were analysed by direct injection without sample pre-treatment. The mechanism of enhancement of fluorescence of the derivative by surfactant was proposed.展开更多
基金supported by National Natural Science Foundation of China(No.11875285)。
文摘With more than 30 years of development,laser-induced fluorescence(LIF)is becoming an increasingly common diagnostic to measure ion and neutral velocity distribution functions in different fields of studies in plasma science including Hall thrusters,linear devices,plasma processing,and basic plasma physical processes.In this paper,technical methods used in the LIF diagnostic,including modulation,collection optics,and wavelength calibration techniques are reviewed in detail.A few basic physical processes along with applications and future development associated with the LIF diagnostics are also reviewed.
基金supported by the National Natural Science Foundation of China(Grant No.11272338)the Science and Technology on Scramjet Key Laboratory Funding,China(Grant No.STSKFKT 2013004)the China Scholarship Council
文摘An accurate and reasonable technique combining direct absorption spectroscopy and laser-induced fluorescence(LIF)methods is developed to quantitatively measure the concentrations of hydroxyl in CH;/air flat laminar flame. In our approach, particular attention is paid to the linear laser-induced fluorescence and absorption processes, and experimental details as well. Through measuring the temperature, LIF signal distribution and integrated absorption, spatially absolute OH concentrations profiles are successfully resolved. These experimental results are then compared with the numerical simulation. It is proved that the good quality of the results implies that this method is suitable for calibrating the OH-PLIF measurement in a practical combustor.
基金supported by the National Key Scientific Instrument and Equipment Development Projects of China(Grant No.2012YQ040164)the National Natural Science Foundation of China(Grant Nos.61275127 and 91441130)+1 种基金the China Postdoctoral Science Foundation(Grant No.2014M560262)the Postdoctoral Fellowship in Heilongjiang Province,China(Grant No.LBH-Z14074)
文摘The one-dimensional (1D) spatial distributions of OH absolute concentration in methane/air laminar premixed flat flame under different equivalence ratios at atmospheric pressure are investigated by using bi-directional laser-induced flu- orescence (LIF) detection scheme combined with the direct absorption spectroscopy. The effective peak absorption cross section and the average temperature at a height of 2 mm above the burner are obtained by exciting absorption on the Q1(8) rotational line in the A2∑+ (Dt = 0) ←- X2∏ (v = 0) at 309.240 nm. The measured values are 1.86×10-15 cm2 and 1719 K, respectively. Spatial filtering and frequency filtering methods of reducing noise are used to deal with the experi- mental data, and the smoothing effects are also compared using the two methods. The spatial distribution regularities of OH concentration are obtained with the equivalence ratios ranging from 0.8 to 1.3. The spatial resolution of the measured result is 84μm. Finally, a comparison is made between the experimental result of this paper and other relevant study results.
文摘A combined detection system involving simultaneous LIF and contacfless-conductometric measurements at the same place of the microfluidic chip was described. The LIF measurement was designed according to the confocal principle and a moveable contactless-conduetivity detector was used in C^4D. Both measurements were mutually independent and advantageous in analyses of mixtures. Various experimental parameters affecting the response were examined and optimized. The performances were demonstrated by simultaneous detection of Rhodamine B. And the results showed that the combined detection system could be used sensitively and reliably.
基金Project supported by the National Natural Science Foundation of China(Grant No.11272338)the Fund from the Science and Technology on Scramjet Key Laboratory,China(Grant No.STSKFKT2013004)
文摘The aim of the present work is to quantitatively measure the hydroxyl radical concentration by using LIF(laserinduced fluorescence) in flame.The detailed physical models of spectral absorption lineshape broadening,collisional transition and quenching at elevated pressure are built.The fine energy level structure of the OH molecule is illustrated to understand the process with laser-induced fluorescence emission and others in the case without radiation,which include collisional quenching,rotational energy transfer(RET),and vibrational energy transfer(VET).Based on these,some numerical results are achieved by simulations in order to evaluate the fluorescence yield at elevated pressure.These results are useful for understanding the real physical processes in OH-LIF technique and finding a way to calibrate the signal for quantitative measurement of OH concentration in a practical combustor.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11504112,91536218,and 11604100)
文摘The absolute number density of nitrogen dioxide(NO2) seeded in argon is measured with cavity-enhanced laserinduced fluorescence(CELIF) through using a pulsed laser beam for the first time. The cavity ring down(CRD) signal is acquired simultaneously and used for normalizing the LIF signal and determining the relationship between the measured CELIF signal and the NO2 number density. The minimum detectable NO2 density down to(3.6±0.1)10^8 cm^-3 is measured in 60 s of acquisition time by the CELIF method. The minimum absorption coefficient is measured to be(2.0±0.1)10^-9 cm^-1, corresponding to a noise equivalent absorption sensitivity of(2.2±0.1)10^9 cm.^-1Hz^-1/2. The experimental system demonstrated here can be further improved in its sensitivity and used for environmental monitoring of outdoor NO2 pollution.
文摘Argon ion laser induced fluorescence measurements were carried out in a multipolar filament discharge with a broadband diode laser centered on 668 nm, which stimulated a transition from the metastable state in Ar(Ⅲ) 3d4F7/2 to 4p4D0 5/2. The intensity of the induced fluorescence at 442 nm was maximized by the optimization of the discharge parameters and the laser power. From the recovery of the background fluorescence after the laser was turned off, the ion diffusion coefficient was deduced and compared with the result inferred from the experiments of ion acoustic wave (IAW) damping.
文摘A new laser induced fluorescence imaging system used for detecting and locating the petroleum pollutants is presented. A unique feature of the system was using a combination of a frequency tripled Nd:YAG pulse laser and an image intensified CCD camera as imaging detector. The delay time of the system and the exposure time of the CCD are controlled by a delay generator. Petroleum pollutants on various backgrounds had been detected and located by this system. This imaging technique provides a useful noninvasive approach for the detection of petroleum pollutants, which can be used in remote sensing.
文摘cis-1,3,4,6-Tetranitrooctahydroimidazo-[4,5 d]imidazole(BCHMX)is an advanced energetic compound that expected to spread worldwide in the near future.Since,no approved remote detection methods were reported in current literature for this material,we performed hyper-spectral imaging and laser induced fluorescence(LIF)to a BCHMX sample under low laser fluence for determining the optimum laser wavelength used in any future BCHMX-LIF based remote detection systems.For this purpose,an experimental setup consisted of a sun spectrum lamp and hyper-spectral camera was built to illuminate and image white powder samples of BCHMX in comparison with the traditional explosives,HMX(1,3,5,7-tetranitro-1,3,5,7-tetraazacyclooctane),RDX(1,3,5-trinitro-1,3,5-triazacyclohexane),PETN(2,2-Bis[(nitroxy)methyl]propane-1,3-diyldinitrate).The imaging reveals strong BCHMX sample absorption contrast among other samples at wavelength ranging from 400 to 410 nm.When light source was replaced by a 405 nm laser diode illuminator,a strong BCHMX sample LIF at the spectral range from 425 to 700 nm was observed under low laser fluence condition of 0.1 mJ/cm^(2).Finally,we demonstrated successfully the ability of the 405 nm LIF and the hyperspectral imaging technique to detect finger print traces of BCHMX on white cellulose fabric from a distance of 15 m and a detection limit of 1 mg/cm^(2).
文摘High resolution laser induced fluorescence, spectra of IrN in the spectral region between 394 and 520 nm were recorded using laser vaporization/reaction free jet expansion and laser induced fluorescence spectroscopy. Seven new vibronic transition bands were observed and analyzed. Two Ω=1 and five Ω=0 new states were identified. Least squares fit of rotationally resolved transition lines yielded accurate molecular constants for the upper states. Spectra of isotopic molecules were observed, which provided confirmation for the vibrational assignment. Comparison of the observed electronic states of IrB, IrC, and IrN provides a good understanding of the chemical bonding of this group of molecules.
基金Key Science and Technology Project Tackled of Guangdong Province(B2050070)
文摘The characteristics such as signal noise ratio(SNR) and sensitivity of the fluorescence detection system for micro-fluidic chip influence the performance of the whole system extremely. The confocal laser induced fluorescence detection system is presented. Based on the debugging of optical and circuit modules, the results of detecting the samples are given and analyzed theoretically, and the improved project is put forward.
文摘N-Conjugated antigen was synthesized and polyclonal antibody with high specificity was obtained from immunizing animals. With this polyclonal antibody, a rapid and efficient CEIA-LIF method was developed to determine the free morphine in urine of abusers. The detection limit was calculated to be 40 ng/mL. Simulated urine samples were analyzed with good recoveries, which showed the feasibility of its application in specific morphine determination in urine of morphine abusers.
基金supported by the National Natural Science Foundation of China,the State Key Laboratory of Microbial Technology,Shandong University.
文摘A novel approach for analysis of amino acids in individual erythrocytes was established. In this method, the derivatization reagent was introduced into the living cells by electroporation. After derivatization, the amino acids in a single cell were determined by capillary electrophoresis with laser-induced fluorescence detection.
文摘The main goal of this work was to quantify the detection of colistin at low levels in urine samples through the practical application of mixed surfactant micellar electrokinetic chromatography–laser-induced fluorescence (MEKC-LIF) analysis method using its advantage of sensitivity and to examine direct injection of biological samples. Colistin (po- lymyxin E) has neither strong UV chromophore nor fluorophore. So, its assay for metabolism, pharmacokinetics studies for bioavailability and bioequivalence are difficult because of poor detectability. Therefore an enhanced UV or fluores-cence detection by chemical derivatization is required. MEKC-LIF method was proposed for colistin with a 488/520 nm argon-ion laser using a pre-CE derivatization with fluorescein isothiocyanate (FITC). Borate buffer was used as background buffer (BGB). The different parameters affecting the proposed derivatization reaction including concentration of the derivatizing reagent, reaction time and temperature were studied and optimized. The derivative was stable for up to 3 days. Different micelles (TX-100 and SDS) were examined as BGB additives separately but negative-charged mixed micelles (SDS/TX-100) were shown to be the best additive to BGB for the analysis of colistin particularly in human urine as they enhance both selectivity and sensitivity of the proposed method. BGB was used with pH 9.5, 10 kV, 8 s inj time, capillary length 75 cm × 75 μm ID (66 cm effective length), detection was LIF Ex 488 nm;Em 520 nm. The method was applied to colistin analysis in human urine and the recovery was > 98% (n = 5). LOD and LOQ in urine after pre-column derivatization using FITC were 100 and 250 ng/ml, respectively. Urine samples were analysed by direct injection without sample pre-treatment. The mechanism of enhancement of fluorescence of the derivative by surfactant was proposed.
基金This work was supported by the National Natural Science Foundation of China(No.52206222,No.22227901)State Key Laboratory of Laser Interaction with Matter Foundation(SKLLIM2009).