期刊文献+
共找到207篇文章
< 1 2 11 >
每页显示 20 50 100
Self-Absorption Effects on Electron Temperature-Measurements Utilizing Laser Induced Breakdown Spectroscopy (LIBS)-Techniques 被引量:1
1
作者 Shawqi A. M. Mansour 《Optics and Photonics Journal》 2015年第3期79-90,共12页
In the present work, we have studied the temporal evolution of aluminum alloy plasma produced by the fundamental (1064 nm) of a Q-switched Nd:YAG laser by placing the target material in air at atmospheric pressure. Th... In the present work, we have studied the temporal evolution of aluminum alloy plasma produced by the fundamental (1064 nm) of a Q-switched Nd:YAG laser by placing the target material in air at atmospheric pressure. The four Al I-neutral lines at 308.21, 309.27, 394.40 and 369.15 nm as well as Al II-ionic lines at 281.61, 385.64 and 466.30 nm are used for the determination of the electron temperature Te using Saha-Boltzmann plot method. The neutral aluminum lines were found to suffer from optical thickness which manifested itself on the form of scattered points around the Saha-Boltzmann line. The isolated optically thin hydrogen Hα-line at 656.27 nm appeared in the spectra under the same experimental conditions was used to correct the Al I-lines which contained some optical thickness. The measurements were repeated at different delay times ranging from 1 to 5 μs. The comparison between the deduced electron temperatures from aluminum neutral lines before correction against the effect self-absorption to that after correction revealed a precise value in temperature. The results sure that, in case of the presence of self-absorption effect the temperature varies from (1.4067 - 1.2548 eV) as the delay time is varied from 0 to 5 μs. Whereas, in the case of repairing against the effect, it varies from (1.2826 - 0.8961 eV) for the same delay time variation. 展开更多
关键词 laser Induces breakdown spectroscopy (libs) SELF-ABSORPTION (SA) Saha-Boltzmann PLOT Delay Time (Td) Electron Number Density (Ne) Plasma Temperature (Te)
下载PDF
高精度煤质成分快速定量分析LIBS系统研究
2
作者 刘树林 王猛 +3 位作者 李安 张颖 刘晓东 刘瑞斌 《光学精密工程》 EI CAS CSCD 北大核心 2024年第10期1470-1480,共11页
煤质成分的快速、高精度定量分析是工厂对能源高效利用的重要环节。本文通过利用搭建的激光诱导击穿技术煤质快速分析仪,对所采集煤样工业特性固定碳(FixC),灰分(Ash),干燥无灰基的挥发分(Vdaf),热值(Q)进行了定量测量,并对测得的数据... 煤质成分的快速、高精度定量分析是工厂对能源高效利用的重要环节。本文通过利用搭建的激光诱导击穿技术煤质快速分析仪,对所采集煤样工业特性固定碳(FixC),灰分(Ash),干燥无灰基的挥发分(Vdaf),热值(Q)进行了定量测量,并对测得的数据与实验室人工测量数据进行对比分析,检验得出该方法在煤质分析方面准确快速。通过对设备稳定性和动态精密度的测试,结果表明了快速煤质分析仪具有较高的稳定性,满足国标规定值。在预测灰分值分布跨度为5%~60%的煤样时,通过增加样品量,增加模型中对大灰分煤样的预测权重,实现预测均方根误差RMSEP<1%的预测精度,挥发分和全硫的RMSEP<1%,热值的RMSEP<0.18 MJ/kg。预测结果均达到工业分析要求,可以满足工业现场的应用需求,具有应用于煤质在线检测方面的广阔前景。 展开更多
关键词 激光诱导击穿光谱 定量分析 快速煤质分析 稳定性
下载PDF
基于LIBS光谱实现燃煤企业碳排放量高精度快速预测
3
作者 王猛 刘树林 +4 位作者 刘晓东 孙浩瀚 张颖 李安 刘瑞斌 《西安科技大学学报》 CAS 北大核心 2024年第3期597-603,共7页
准确预测煤炭的碳排放数据是实现中国“双碳”目标的重要基础。在煤炭入炉前完成碳排放量数据和煤质指标的精确、快速预测,将转变目前“先排放,后检测”的碳排放数据计算方式,对落实“双碳”战略意义重大。以煤炭碳含量和煤质指标的精... 准确预测煤炭的碳排放数据是实现中国“双碳”目标的重要基础。在煤炭入炉前完成碳排放量数据和煤质指标的精确、快速预测,将转变目前“先排放,后检测”的碳排放数据计算方式,对落实“双碳”战略意义重大。以煤炭碳含量和煤质指标的精准预评估为研究目标,通过自行搭建激光诱导击穿光谱(Laser Induced Breakdown Spectroscopy,LIBS)系统和LIBS光谱统计分析,利用主成分分析-偏最小二乘(PCA-PLS)结合小样本算法对训练集进行回归训练,建立了一种煤炭的碳排放预测模型,并通过在新疆A电厂和山东B电厂中的实际应用,证明了LIBS系统在煤质指标分析中的可靠性。结果表明:所提出的预测方法与传统方法相比绝对误差最大为0.0256 t,表现出较好的碳排放预测能力。所提方法可以用于燃煤企业碳排放量的精准预测,为实现煤炭碳排放和煤质指标的预评估提供了一种较为高效的技术解决路径。 展开更多
关键词 激光诱导击穿光谱技术 碳排放 高精度快速预测
下载PDF
Laser-Induced Breakdown Spectroscopy (LIBS) Applied in the Differentiation of <i>Arabica</i>and <i>Robusta</i>Coffee
4
作者 Abigail María Díaz Guerrero Luis Vidal Ponce Cabrera +1 位作者 Teresa Flores Reyes Rogelio Ortega Izaguirre 《Optics and Photonics Journal》 2017年第10期181-195,共15页
Coffee is one of the most consumed and commercialized crops in the world, which is why there is a potential risk to find arabica coffee (an expensive variety) adulterated with robusta coffee (a cheaper variety). The c... Coffee is one of the most consumed and commercialized crops in the world, which is why there is a potential risk to find arabica coffee (an expensive variety) adulterated with robusta coffee (a cheaper variety). The currently used technique for certifying coffee, High Performance Liquid Chromatography (HPLC), requires the sample to be subjected to a chemical treatment prior to analysis;in addition, the equipment is bulky and can not be moved easily. Laser Induced Breakdown Spectroscopy (LIBS) is a technique which does not require that samples be subjected to a chemical pretreatment, and equipment is small and portable, this can save valuable time in coffee trading. The purpose of this research was to demonstrate that LIBS can be applied to solve various problems related with the coffee authentication. Green coffee pills with different concentrations of arabica and robusta varieties were analyzed by LIBS, the results were used in the construction of calibration curves for the detection of the degree of simulated adulteration in coffee. It was found that the relative intensities of Ca (392.4 nm), Sr (407.1 nm), N (500.5 nm) and Na (588.7 nm), as well as the intensity ratios of Ca II (392.4 nm)/N I (500.5 nm), Sr I (407.1 nm)/N I (500.5 nm)and N I (500.5 nm)/Na I (588.7 nm) can be used for this purpose. It is concluded that the differentiation of coffee and the detection of its adulteration is possible with the use of LIBS. Further, with the use of an Artificial Neural Network (ANN) of type Multilayer Perceptron, it was possible to correctly classify the spectra of arabica and robusta roasted coffee. 展开更多
关键词 laser Induced breakdown spectroscopy (libs) Calibration Curves Artificial Neural Network (ANN) Multilayer PERCEPTRON
下载PDF
Comparison of Calibration Curve Method and Partial Least Square Method in the Laser Induced Breakdown Spectroscopy Quantitative Analysis 被引量:1
5
作者 Zhi-bo Cong Lan-xiang Sun +2 位作者 Yong Xin Yang Li Li-feng Qi 《Journal of Computer and Communications》 2013年第7期14-18,共5页
The Laser Induced Breakdown Spectroscopy (LIBS) is a fast, non-contact, no sample preparation analytic technology;it is very suitable for on-line analysis of alloy composition. In the copper smelting industry, analysi... The Laser Induced Breakdown Spectroscopy (LIBS) is a fast, non-contact, no sample preparation analytic technology;it is very suitable for on-line analysis of alloy composition. In the copper smelting industry, analysis and control of the copper alloy concentration affect the quality of the products greatly, so LIBS is an efficient quantitative analysis tech- nology in the copper smelting industry. But for the lead brass, the components of Pb, Al and Ni elements are very low and the atomic emission lines are easily submerged under copper complex characteristic spectral lines because of the matrix effects. So it is difficult to get the online quantitative result of these important elements. In this paper, both the partial least squares (PLS) method and the calibration curve (CC) method are used to quantitatively analyze the laser induced breakdown spectroscopy data which is obtained from the standard lead brass alloy samples. Both the major and trace elements were quantitatively analyzed. By comparing the two results of the different calibration method, some useful results were obtained: both for major and trace elements, the PLS method was better than the CC method in quantitative analysis. And the regression coefficient of PLS method is compared with the original spectral data with background interference to explain the advantage of the PLS method in the LIBS quantitative analysis. Results proved that the PLS method used in laser induced breakdown spectroscopy was suitable for simultaneous quantitative analysis of different content elements in copper smelting industry. 展开更多
关键词 laser-INDUCED breakdown spectroscopy (libs) PARTIAL Least SQUARE Method (PLS) Matrix Effects Quantitative Analysis
下载PDF
基于共焦LIBS技术结合机器学习的矿石分类识别方法 被引量:2
6
作者 苏云鹏 贺春景 +3 位作者 李昂泽 徐可米 邱丽荣 崔晗 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2023年第3期692-697,共6页
矿物分类与识别是地质研究领域的重要内容,对地质勘探和环境演化的研究具有重要意义。然而,传统的矿石分类识别方法依靠专业人员通过矿石的外形及物理性质进行人工鉴定,主观性强,准确率低,激光诱导击穿光谱技术(LIBS)由于其元素“指纹... 矿物分类与识别是地质研究领域的重要内容,对地质勘探和环境演化的研究具有重要意义。然而,传统的矿石分类识别方法依靠专业人员通过矿石的外形及物理性质进行人工鉴定,主观性强,准确率低,激光诱导击穿光谱技术(LIBS)由于其元素“指纹”特性、灵敏度高以及快速在线检测的特点,非常适合用于地质研究领域。利用共焦激光诱导击穿光谱技术与机器学习结合,提高了矿石分类识别的精准度,利用共焦LIBS系统获得8种天然矿石样品(金矿、铜矿、银辉矿、赤铁矿、铝矿、方铅石、磷灰石以及闪锌矿)的光谱数据,采用主成分分析方法(PCA)对数据进行降维处理,并对降维后的数据采用线性判别分析(LDA)、最邻近规则(KNN)以及支持向量机(SVM)三种方法进行特征谱线的高精准分类识别。首先,采用标准铜片作为样品,对比了非共焦LIBS系统和共焦LIBS系统的稳定性及其对PCA主成分累计贡献率的影响,结果表明与非共焦LIBS系统相比,共焦LIBS系统的稳定性提升了63.75%,主成分累计贡献率提高了17.81%;然后,采用共焦LIBS系统获取上述8种矿石样品的光谱信息,并进行去噪等预处理,采用PCA对矿石特征数据进行提取,并保留累计贡献率达到99.4%的前10维特征空间;最后,将特征数据分别与LDA,KNN以及SVM结合构建分类模型,进行种类识别。结果表明,PCA方法与LDA和KNN方法结合的分类准确度分别为95.78%和92.58%,而与SVM相结合的方法,准确率可达到97.89%。因此,采用共焦激光诱导击穿光谱技术与PCA和SVM相结合的方法,可为地质勘探和矿物识别领域提供一种快速、高准确度的分类识别方式,具有广阔的应用前景。 展开更多
关键词 激光诱导击穿光谱 共焦libs 主成分分析 机器学习
下载PDF
Quantitative analysis of C, Si, Mn, Ni, Cr and Cu in low-alloy steel under ambient conditions via laser-induced breakdown spectroscopy 被引量:4
7
作者 罗丹 刘英 +3 位作者 李香宇 赵珍阳 王世功 张勇 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第7期152-158,共7页
A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors,... A diode-pumped solid-state laser (DPSSL) with a high energetic stability and long service life is applied to ablate the steel samples instead of traditional Nd:YAG laser pumped by a xenon lamp, and several factors, such as laser pulse energy, repetition rate and argon flow rate, that influence laser-induced breakdown spectroscopy (LIBS) analytical performance are investigated in detail. Under the optimal experiment conditions, the relative standard deviations for C, Si, Mn, Ni, Cr and Cu are 3.3%-8.9%, 0.9%-2.8%, 1.2%-4.1%, 1.7%-3.0%, 1.1%-3.4% and 2.5%-8.5%, respectively, with the corresponding relative errors of 1.1%-7.9%, 1.0%-6.3%, 0.4%-3.9%, 1.5%-6.3%, 1.2%-4.0% and 1.2%-6.4%. Compared with the results of the traditional spark discharge optical emission spectrometry technique, the analytical performance of LIBS is just a little inferior due to the less stable laser-induced plasma and smaller amount of ablated sample by the laser. However, the precision, detection limits and accuracy of LIBS obtained in our present work were sufficient to meet the requirements for process analysis. These technical performances of higher stability of output energy and longer service life for DPSSL, in comparison to the Q-switch laser pumped by xeon lamp, qualify it well for the real time online analysis for different industrial applications. 展开更多
关键词 laser-induced breakdown spectroscopy (libs diode-pumped solid-state laser(DPSSL) optical emission spectrometry laser-induced plasma
下载PDF
A rapid classification method of aluminum alloy based on laser-induced breakdown spectroscopy and random forest algorithm 被引量:6
8
作者 詹浏洋 马晓红 +4 位作者 方玮骐 王锐 刘泽生 宋阳 赵华凤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期148-154,共7页
As an important non-ferrous metal structural material most used in industry and production,aluminum(Al) alloy shows its great value in the national economy and industrial manufacturing.How to classify Al alloy rapidly... As an important non-ferrous metal structural material most used in industry and production,aluminum(Al) alloy shows its great value in the national economy and industrial manufacturing.How to classify Al alloy rapidly and accurately is a significant, popular and meaningful task.Classification methods based on laser-induced breakdown spectroscopy(LIBS) have been reported in recent years. Although LIBS is an advanced detection technology, it is necessary to combine it with some algorithm to reach the goal of rapid and accurate classification. As an important machine learning method, the random forest(RF) algorithm plays a great role in pattern recognition and material classification. This paper introduces a rapid classification method of Al alloy based on LIBS and the RF algorithm. The results show that the best accuracy that can be reached using this method to classify Al alloy samples is 98.59%, the average of which is 98.45%. It also reveals through the relationship laws that the accuracy varies with the number of trees in the RF and the size of the training sample set in the RF. According to the laws, researchers can find out the optimized parameters in the RF algorithm in order to achieve,as expected, a good result. These results prove that LIBS with the RF algorithm can exactly classify Al alloy effectively, precisely and rapidly with high accuracy, which obviously has significant practical value. 展开更多
关键词 laser-INDUCED breakdown spectroscopy(libs) RANDOM forest(RF) aluminum(Al)alloy classification
下载PDF
Laser Induced Breakdown Spectroscopy for Comparative Quantitative Analysis of Betel Leaves from Pakistan 被引量:1
9
作者 I Rehan K Rehan +1 位作者 S Sultana R Muhammad 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2018年第10期3295-3302,共8页
Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean ... Laser induced breakdown Spectroscopy(LIBS)was applied for the elemental analysis and exposure of the heavy metals in betel leaves in air.Pulsed Nd∶YAG(1064 nm)in conjunction with a suitable detector(LIBS 2000+,Ocean Optics,Inc)having the optical resolution of 0.06 nm was used to record the emission spectra from 220 to 720 nm.Elements like Al,Ba,Ca,Cr,Cu,P,Fe,K,Mg,Mn,Na,P,S,Sr,and Zn were found to present in the samples.The relative abundances of the observed elements were calculated through standard calibration curve method,integrated intensity ratio method,and weight percentage LIBS approach.LIBS findings were validated by comparing its results with the results obtained using a typical analytical technique of Inductively Coupled plasma-optical emission spectroscopy(ICP-OES).Limit of detection(LOD)of the LIBS system was also estimated for heavy metals.The experience gain through this work implies that LIBS could be highly applicable for testing the quality and purity of food products. 展开更多
关键词 laser induced breakdown spectroscopy(libs) Spectral analysis inductively coupled plasma-optical emission SPECTROMETRY Limit of detection(LOD)
下载PDF
Simultaneous Measurements of Coal Ash Composition by Laser-induced Breakdown Spectroscopy in Different Optical Collection 被引量:4
10
作者 YAO Shunchun LU Jidong DONG Meirong ZHENG Jianping LI Jun ZHANG Bo 《中国电机工程学报》 EI CSCD 北大核心 2013年第11期I0008-I0008,10,共1页
针对燃煤组分分布不均匀的特性,研究不同收光模式对激光诱导击穿光谱技术同步测量灰成分的影响。选用具有不同灰成分含量梯度的燃煤样品作为检测对象,对比分析同向收光和侧向收光下灰成分组成元素谱线信号探测的强度和稳定性及SiO2、A... 针对燃煤组分分布不均匀的特性,研究不同收光模式对激光诱导击穿光谱技术同步测量灰成分的影响。选用具有不同灰成分含量梯度的燃煤样品作为检测对象,对比分析同向收光和侧向收光下灰成分组成元素谱线信号探测的强度和稳定性及SiO2、Al2O3、Fe2O3、CaO、MgO和TiO2含量定量分析的精确度。研究结果表明,相同实验条件下同向收光模式的光谱信号稳定性和定量分析精确度更好,检验样品中各灰成分的预测值和参考值之间的拟合度均在0.986以上。而侧向收光模式下探测到的光谱信号强度更强,光谱探测下限可以达到190nm。 展开更多
关键词 激光诱导 光谱仪 粉煤灰 同时测量 击穿 眼镜 组成 安全经济运行
下载PDF
Laser-induced breakdown spectroscopy applied to the characterization of rock by support vector machine combined with principal component analysis 被引量:6
11
作者 杨洪星 付洪波 +3 位作者 王华东 贾军伟 Markus W Sigrist 董凤忠 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第6期290-295,共6页
Laser-induced breakdown spectroscopy(LIBS) is a versatile tool for both qualitative and quantitative analysis.In this paper,LIBS combined with principal component analysis(PCA) and support vector machine(SVM) is... Laser-induced breakdown spectroscopy(LIBS) is a versatile tool for both qualitative and quantitative analysis.In this paper,LIBS combined with principal component analysis(PCA) and support vector machine(SVM) is applied to rock analysis.Fourteen emission lines including Fe,Mg,Ca,Al,Si,and Ti are selected as analysis lines.A good accuracy(91.38% for the real rock) is achieved by using SVM to analyze the spectroscopic peak area data which are processed by PCA.It can not only reduce the noise and dimensionality which contributes to improving the efficiency of the program,but also solve the problem of linear inseparability by combining PCA and SVM.By this method,the ability of LIBS to classify rock is validated. 展开更多
关键词 laser-induced breakdown spectroscopy(libs principal component analysis(PCA) support vector machine(SVM) lithology identification
下载PDF
Determination of Iron in Water Solution by Time-Resolved Femtosecond Laser-Induced Breakdown Spectroscopy 被引量:3
12
作者 Sergey S.GOLIK Alexey A.ILYIN +3 位作者 Michael Yu.BABIY Yulia S.BIRYUKOVA Vladimir V.LISITSA Oleg A.BUKIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期975-978,共4页
The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphi... The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphire laser radiation with pulse duration 〈45 fs and energies up to 7 mJ is determined. A calibration curve was obtained for Fe3+ concentration range from 0.5 g/L to the limit of detection in water solution, and its saturation was detected for concentrations above 0.25 g/L, which is ascribed to self-absorption. The 3σ- limit of detection obtained for Fe in water solution is 2.6 mg/L in the case of 7 mJ laser pulse energy. It is found that an increase of laser pulse energy insignificantly affects on LOD in the time-resolved LIBS and leads to a slight improvement of the limit of detection. 展开更多
关键词 femtosecond laser-induced breakdown spectroscopy libs femtosecond plasma IRON analysis of water atomic emission spectroscopy limit of detection
下载PDF
Characterization of the Delamination Defects in Marine Steel Using Laser-Induced Breakdown Spectroscopy 被引量:2
13
作者 杨春 贾云海 +5 位作者 张勇 李冬玲 刘佳 陈吉文 陈永彦 刘英 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第8期671-675,共5页
In this paper, two types of comparison analyses, bulk analysis and defect analysis, were carried out for marine steel. The results of laser-induced breakdown spectroscopy (LIBS) were compared with those of spark opt... In this paper, two types of comparison analyses, bulk analysis and defect analysis, were carried out for marine steel. The results of laser-induced breakdown spectroscopy (LIBS) were compared with those of spark optical emission spectrometry (Spark-OES) and scanning electron microscopy/energy dispersion spectroscopy (SEM/EDS) in the bulk and defect analyses. The comparison of the bulk analyses shows that the chemical contents of C, Si, Mn, P, S and Cr obtained from LIBS agree well with those determined using Spark-OES. The LIBS is slightly less precise than Spark-OES. Defects were characterized in the two-dimensional distribution analysis mode for Al, Mg, Ca, Si and other elements. Both the LIBS and SEM/EDS results show the enrichment of Al, Mg, Ca and Si at the defect position and the two methods agree well with each other. SEM/EDS cannot provide information about the difference in the chemical constituents when the differences between the defect position and the normal position are not significant. However, LIBS can provide this information, meaning that the sensitivity of LIBS is higher than that of SEM/EDS. LIBS can be used to rapidly characterize marine steel defects and provide guidance for improving metallurgical processes. 展开更多
关键词 laser-induced breakdown spectroscopy (libs marine steel defects in ironand steel
下载PDF
Development of a Laboratory Cement Quality Analysis Apparatus Based on Laser-Induced Breakdown Spectroscopy 被引量:2
14
作者 樊娟娟 张雷 +10 位作者 王鑫 李郁芳 弓瑶 董磊 马维光 尹王保 王哲 李政 张向杰 李逸 贾锁堂 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期897-903,共7页
Determination of the chemical composition of cement and ratio values of clinker plays an important role in cement plants as part of the optimal process control and product quality evaluation. In the present paper, a l... Determination of the chemical composition of cement and ratio values of clinker plays an important role in cement plants as part of the optimal process control and product quality evaluation. In the present paper, a laboratory laser-induced breakdown spectroscopy (LIBS) apparatus mainly comprising a sealed optical module and an analysis chamber has been designed for possible application in cement plants for on-site quality analysis of cement. Emphasis is placed on the structure and operation of the LIBS apparatus, the sealed optical path, the temperature controlled spectrometer, the sample holder, the proper calibration model established for minimizing the matrix effects, and a correction method proposed for overcoming the 'drift' obstacle. Good agreement has been found between the laboratory measurement results from the LIBS method and those from the traditional method. The absolute measurement errors presented here for oxides analysis are within 0.5%, while those of ratio values are in the range of 0.02 to 0.05. According to the obtained results, this laboratory LIBS apparatus is capable of performing reliable and accurate, composition and proximate analysis of cement and is suitable for application in cement plants. 展开更多
关键词 laser-induced breakdown spectroscopy libs CEMENT composition analysis proximate analysis ratio values linear correction method
下载PDF
基于UVE变量筛选偏最小二乘的LIBS磷精矿浆定量分析
15
作者 房胜楠 史烨弘 +2 位作者 韩鹏程 赵振 李华昌 《矿冶》 CAS 2023年第1期109-114,共6页
利用激光诱导击穿光谱(Laser Induced Breakdown Spectroscopy, LIBS)技术采集得到磷精矿浆的光谱,基于无信息变量消除(Uniformative Variables Elimination, UVE)方法筛选出与磷元素相关的波长变量,将选择后的波长作为自变量建立偏最... 利用激光诱导击穿光谱(Laser Induced Breakdown Spectroscopy, LIBS)技术采集得到磷精矿浆的光谱,基于无信息变量消除(Uniformative Variables Elimination, UVE)方法筛选出与磷元素相关的波长变量,将选择后的波长作为自变量建立偏最小二乘(Partial Least Squares, PLS)回归模型,并与传统全谱PLS和GA-PLS(Genetic Algorithm-Partial Least Squares, GA-PLS)定标模型进行比较。相比全谱PLS,UVE-PLS定标模型的性能更优,其预测均方根误差(Root-mean-square Error of Prediction, RMSEP)由0.38%下降到0.26%,决定系数(R2)从0.59提高到0.72。相比GA-PLS定标模型,UVE方法可以克服GA(Genetic Algorithm, GA)在参量选择上存在随机性的弊端,筛选出的变量仅为全谱的8.76%,而且计算速度更快,分析精度也优于GA-PLS模型。 展开更多
关键词 激光诱导击穿光谱(libs) 无信息变量消除(UVE) 偏最小二乘法(PLS) 磷矿浆 变量筛选
下载PDF
Detection of K in soil using time-resolved laser-induced breakdown spectroscopy based on convolutional neural networks 被引量:1
16
作者 吕程序 王博 +3 位作者 姜训鹏 张俊宁 牛康 苑严伟 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期108-113,共6页
One of the technical bottlenecks of traditional laser-induced breakdown spectroscopy(LIBS) is the difficulty in quantitative detection caused by the matrix effect. To troubleshoot this problem,this paper investigated ... One of the technical bottlenecks of traditional laser-induced breakdown spectroscopy(LIBS) is the difficulty in quantitative detection caused by the matrix effect. To troubleshoot this problem,this paper investigated a combination of time-resolved LIBS and convolutional neural networks(CNNs) to improve K determination in soil. The time-resolved LIBS contained the information of both wavelength and time dimension. The spectra of wavelength dimension showed the characteristic emission lines of elements, and those of time dimension presented the plasma decay trend. The one-dimensional data of LIBS intensity from the emission line at 766.49 nm were extracted and correlated with the K concentration, showing a poor correlation of R_c^2?=?0.0967, which is caused by the matrix effect of heterogeneous soil. For the wavelength dimension, the two-dimensional data of traditional integrated LIBS were extracted and analyzed by an artificial neural network(ANN), showing R_v^2?=?0.6318 and the root mean square error of validation(RMSEV)?=?0.6234. For the time dimension, the two-dimensional data of time-decay LIBS were extracted and analyzed by ANN, showing R_v^2?=?0.7366 and RMSEV?=?0.7855.These higher determination coefficients reveal that both the non-K emission lines of wavelength dimension and the spectral decay of time dimension could assist in quantitative detection of K.However, due to limited calibration samples, the two-dimensional models presented over-fitting.The three-dimensional data of time-resolved LIBS were analyzed by CNNs, which extracted and integrated the information of both the wavelength and time dimension, showing the R_v^2?=?0.9968 and RMSEV?=?0.0785. CNN analysis of time-resolved LIBS is capable of improving the determination of K in soil. 展开更多
关键词 quantitative DETECTION potassium(K) SOIL TIME-RESOLVED laser-INDUCED breakdown spectroscopy(libs) convolutional neural networks(CNNs)
下载PDF
Quantitative analysis of steel and iron by laser-induced breakdown spectroscopy using GA-KELM 被引量:1
17
作者 梅亚光 程树森 +4 位作者 郝中骐 郭连波 李祥友 曾晓雁 葛军亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第3期167-173,共7页
According to the multiple researches in the last couple of years, laser-induced breakdown spectroscopy(LIBS) has shown a great potential for rapid analysis in steel industry.Nevertheless, the accuracy and precision ma... According to the multiple researches in the last couple of years, laser-induced breakdown spectroscopy(LIBS) has shown a great potential for rapid analysis in steel industry.Nevertheless, the accuracy and precision may be limited by complex matrix effect and selfabsorption effect of LIBS seriously. A novel multivariate calibration method based on genetic algorithm-kernel extreme learning machine(GA-KELM) is proposed for quantitative analysis of multiple elements(Si, Mn, Cr, Ni, V, Ti, Cu, Mo) in forty-seven certified steel and iron samples.First, the standardized peak intensities of selected spectra lines are used as the input of model.Then, the genetic algorithm is adopted to optimize the model parameters due to its obvious capability in finding the global optimum solution. Based on these two steps above, the kernel method is introduced to create kernel matrix which is used to replace the hidden layer's output matrix. Finally, the least square is applied to calculate the model's output weight. In order to verify the predictive capability of the GA-KELM model, the R-square factor(R^2), Root-meansquare Errors of Calibration(RMSEC), Root-mean-square Errors of Prediction(RMSEP) of GAKELM model are compared with the traditional PLS algorithm, respectively. The results confirm that GA-KELM can reduce the interference from matrix effect and self-absorption effect and is suitable for multi-elements calibration of LIBS. 展开更多
关键词 laser-INDUCED breakdown spectroscopy(libs) alloy elements calibration genetic algorithm-kernel extreme learning machine(GA-KELM)
下载PDF
Parameters Optimization of Laser-Induced Breakdown Spectroscopy Experimental Setup for the Case with Beam Expander 被引量:1
18
作者 王鑫 张雷 +6 位作者 樊娟娟 李郁芳 弓瑶 董磊 马维光 尹王保 贾锁堂 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第11期914-918,共5页
Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quant... Improvement of measurement precision and repeatability is one of the issues currently faced by the laser-induced breakdown spectroscopy (LIBS) technique, which is expected to be capable of precise and accurate quantitative analysis. It was found that there was great potential to improve the signal quality and repeatability by reducing the laser beam divergence angle using a suitable beam expander (BE). In the present work, the influences of several experimental parameters for the case with BE are studied in order to optimize the analytical performances: the signal to noise ratio (SNR) and the relative standard deviation (RSD). We demonstrate that by selecting the optimal experimental parameters, the BE-included LIBS setup can give higher SNR and lower RSD values of the line intensity normalized by the whole spectrum area. For validation purposes, support vector machine (SVM) regression combined with principal component analysis (PCA) was used to establish a calibration model to realize the quantitative analysis of the ash content. Good agreement has been found between the laboratory measurement results from the LIBS method and those from the traditional method. The measurement accuracy presented here for ash content analysis is estimated to be 0.31%, while the average relative error is 2.36%. 展开更多
关键词 laser-induced breakdown spectroscopy (libs relative standard deviation(RSD) signal to noise ratio (SNR) beam expander (BE) support vector machine (SVM)
下载PDF
Rapid Detection of Oil Pollution in Soil by Using Laser-Induced Breakdown Spectroscopy 被引量:2
19
作者 Ali KHUMAENI Wahyu Setia BUDI +2 位作者 Asep Yoyo WARDAYA Rinda HEDWIG Koo Hendrik KURNIAWAN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第12期1186-1191,共6页
Detection of oil pollution in soil has been carried out using laser-induced breakdown spectroscopy(LIBS). A pulsed neodymium-doped yttrium aluminum garnet(Nd:YAG) laser(1,064 nm, 8 ns, 200 mJ) was focused onto ... Detection of oil pollution in soil has been carried out using laser-induced breakdown spectroscopy(LIBS). A pulsed neodymium-doped yttrium aluminum garnet(Nd:YAG) laser(1,064 nm, 8 ns, 200 mJ) was focused onto pelletized soil samples. Emission spectra were obtained from oil-contaminated soil and clean soil. The contaminated soil had almost the same spectrum profile as the clean soil and contained the same major and minor elements. However, a C–H molecular band was clearly detected in the oil-contaminated soil, while no C–H band was detected in the clean soil. Linear calibration curve of the C–H molecular band was successfully made by using a soil sample containing various concentrations of oil. The limit of detection of the C–H band in the soil sample was 0.001 mL/g. Furthermore, the emission spectrum of the contaminated soil clearly displayed titanium(Ti) lines, which were not detected in the clean soil. The existence of the C–H band and Ti lines in oil-contaminated soil can be used to clearly distinguish contaminated soil from clean soil. For comparison, the emission spectra of contaminated and clean soil were also obtained using scanning electron microscope-energy dispersive X-ray(SEM/EDX) spectroscopy,showing that the spectra obtained using LIBS are much better than using SEM/EDX, as indicated by the signal to noise ratio(S/N ratio). 展开更多
关键词 laser-induced breakdown spectroscopy libs oil pollution soil analysis C–H molecular band
下载PDF
A Study of the Laser-Induced Breakdown Spectroscopy of Carbon in the Ultraviolet Wavelength Range Under Vacuum Conditions
20
作者 潘从元 杜学维 +3 位作者 曾强 于云偲 王声波 王秋平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第8期682-686,共5页
The influence of a vacuum on the laser-induced breakdown spectroscopy (LIBS) of carbon in the ultraviolet wavelength range is studied. Experiments are performed with graphite using a LIBS system, which consists of a... The influence of a vacuum on the laser-induced breakdown spectroscopy (LIBS) of carbon in the ultraviolet wavelength range is studied. Experiments are performed with graphite using a LIBS system, which consists of a 1064 nm Nd:YAG laser, a vacuum pump, a spectrometer and a vacuum chamber. The vacuum varies from 10 Pa to 1 atm. Atomic lines as well as singly and doubly charged ions are confirmed under the vacuums. A temporal evolution analysis of intensity is performed for the atomic lines of C I 193.09 nm and C I 247.86 nm under different vacuum conditions. Both time-integrated and time-resolved intensity evolutions under vacuums are achieved. The lifetimes of the two atomic lines have similar trends, which supports the point of view of a 'soft spot'. Variations of plasma temperature and electron density under different vacuums are measured. This study is helpful for research on carbon detection using LIBS under vacuum conditions. 展开更多
关键词 laser-induced breakdown spectroscopy (libs CARBON VACUUM EVOLUTION
下载PDF
上一页 1 2 11 下一页 到第
使用帮助 返回顶部