<div style="text-align:justify;"> An intracavity frequency doubling acousto-optically Q-switched Neodymium-doped Yttrium Orthvanadate (Nd:YVO<sub>4</sub>) 457 nm blue laser by employing a t...<div style="text-align:justify;"> An intracavity frequency doubling acousto-optically Q-switched Neodymium-doped Yttrium Orthvanadate (Nd:YVO<sub>4</sub>) 457 nm blue laser by employing a three-mirror folded cavity was demonstrated. With the incident pump power of 40.4 W, the maximum average output power of 439 mW 457 nm laser, and the minimum pulse duration of 86.14 ns and the maximum peak power of 510 W were achieved at 10 kHz. The M<sup>2</sup> factors are 1.23 and 1.61 in X and Y directions, respectively. The power stability in two hours is better than 2%. </div>展开更多
We present a Brillouin–Raman random fiber laser(BRRFL)with full-open linear cavity structure to generate broadband Brillouin frequency comb(BFC)with double Brillouin-frequency-shift spacing.The incorporation of a reg...We present a Brillouin–Raman random fiber laser(BRRFL)with full-open linear cavity structure to generate broadband Brillouin frequency comb(BFC)with double Brillouin-frequency-shift spacing.The incorporation of a regeneration portion consisting of an erbium-doped fiber and a single-mode fiber enables the generation of broadband BFC.The dynamics of broadband BFC generation changing with the pump power(EDF and Raman)and Brillouin pump(BP)wavelength are investigated in detail,respectively.Under suitable conditions,the bidirectional BRRFL proposed can produce a flatamplitude BFC with 40.7-nm bandwidth ranging from 1531 nm to 1571.7 nm,and built-in 242-order Brillouin Stokes lines(BSLs)with double Brillouin-frequency-shift spacing.Moreover,the linewidth of single BSL is experimentally measured to be about 2.5 kHz.The broadband bidirectional narrow-linewidth BRRFL has great potential applications in optical communication,optical sensing,spectral measurement,and so on.展开更多
We present a detailed study of a combined actively and passively Q-switched (CAPQ) laser with an acousto-optic modulator (AOM) and a codoped Cr^4+, Nd^3+ :YAG crystal The hybrid Q-switch approach is used to pro...We present a detailed study of a combined actively and passively Q-switched (CAPQ) laser with an acousto-optic modulator (AOM) and a codoped Cr^4+, Nd^3+ :YAG crystal The hybrid Q-switch approach is used to produce a short laser pulse with stable and tunable repetition rates. The timing jitter, average pulse width, and average pulse amplitude vary periodically with the AOM modulation frequency under a fixed pump power. The repetition rate of the CAPQ laser can be turned approximately from 4 kHz to 16 kHz with the jitter less than 400 ns.展开更多
The wavelength-tunable and switchable narrow bandwidth mode-locking operation is demonstrated in an all fiber laser based on semiconductor-saturable absorber mirror (SESAM). Two narrow-band fiber Bragg gratings cent...The wavelength-tunable and switchable narrow bandwidth mode-locking operation is demonstrated in an all fiber laser based on semiconductor-saturable absorber mirror (SESAM). Two narrow-band fiber Bragg gratings centered at 1029.9nm and 1032nm respectively with a polarization controller inserted between them are used to realize the wavelength switchable between 1029.9nm and 1032nm. The laser delivers different pulse widths of 7.5ps for 1030nm and 20ps for 1032nm. The maximum output power for both could reach -6.5mW at single pulse operation. The output wavelength couM be tuned to about 0.gnm intervals ranging from 1030.2nm to 1031.1 nm and from 1032.15nm to 1033.7nm with the temperature change of the fiber Bragg grating, respectively.展开更多
In order to optimize the laser ablation performance of a micro-thruster with 1U dimensions,which employs a micro semiconductor laser,the impacts of pulse width and glycidyl azide polymer(GAP)thickness on thrust perfor...In order to optimize the laser ablation performance of a micro-thruster with 1U dimensions,which employs a micro semiconductor laser,the impacts of pulse width and glycidyl azide polymer(GAP)thickness on thrust performance were researched.The results showed that with a GAP thickness of 200μm,the single-pulse impulse(I)increased gradually with the increase in the laser pulse width from 50 to 800μs,while the specific impulse(I_(sp)),impulse coupling coefficient(Cm)and ablation efficiency(η)all reached optimal values with a 200μs pulse width.It is worth noting that the optimal pulse width is identical to the ignition delay time.Both Cmandηpeaked with a pulse width of 200μs,reaching 242.22μN W^(-1)and 35.4%,respectively.With the increase in GAP thickness,I and Cmincreased gradually.GAP of different thicknesses corresponded to different optimal laser pulse widths.Under a certain laser pulse width,the optimal GAP thickness should be the most vertical thickness of the ablation pit,and the various propulsion performance parameters at this time were also optimal.With the current laser parameters,the optimal GAP thickness was approximately 150μm,I_(sp)was approximately 322.22 s,andηwas approximately 34.94%.展开更多
The influence of the single photon laser altimeter range-gate width on the detection probability and ranging accuracy is discussed and analyzed,according to the LiDAR equation,single photon detection equation and the ...The influence of the single photon laser altimeter range-gate width on the detection probability and ranging accuracy is discussed and analyzed,according to the LiDAR equation,single photon detection equation and the Monte Carlo method to simulate the experiment.The simulated results show that the probability of detection is not affected by the range gate,while the probability of false alarm is relative to the gate width.When the gate width is 100 ns,the ranging accuracy can accord with the requirements of satellite laser altimeter.But when the range gate width exceeds 400 ns,ranging accuracy will decline sharply.The noise ratio will be more as long as the range gate to get larger,so the refined filtering algorithm during the data processing is important to extract the useful photons effectively.In order to ensure repeated observation of the same point for 25 times,we deduce the quantitative relation between the footprint size,footprint,and frequency repetition according to the parameters of ICESat-2.The related conclusions can provide some references for the design and the development of the domestic single photon laser altimetry satellite.展开更多
Pulsed and continuous-wave(CW)lasers have been widely used as the light sources for photodynamic therapy(PDT)treatment.Singlet oxygen(^(1)O_(2))is known to be a major cytotoxic agent in type-II PDT and can be directly...Pulsed and continuous-wave(CW)lasers have been widely used as the light sources for photodynamic therapy(PDT)treatment.Singlet oxygen(^(1)O_(2))is known to be a major cytotoxic agent in type-II PDT and can be directly detected by its near-infrared luminescence at 1270 nm.As compared to CW laser excitation,the effiects of pulse width and repetition rate of pulsed laser on the kinetics and production of^(1)O_(2)luminescence were quantitatively studied during photosensitization of Rose Bengal.Significant di®erence in kinetics of^(1)O_(2)luminescence was found under the excitation with various pulse widths of nanosecond,microsecond and CW irradiation with power of 20mW.The peak intensity and duration of^(1)O_(2)production varied with the pulse widths for pulsed laser excitation,while the^(1)O_(2)was generated continuously and its production reached a steady state with CW excitation.However,no significant di®erence(P>0:05)in integral^(1)O_(2)production was observed.The results suggest that the PDT efficacy using pulsed laser may be identical to the CW laser with the same wavelength and the same average°uence rate below a threshold in solution.展开更多
The 975 nm multimode diode lasers with high-order surface Bragg diffraction gratings have been simulated and calcu-lated using the 2D finite difference time domain(FDTD)algorithm and the scattering matrix method(SMM)....The 975 nm multimode diode lasers with high-order surface Bragg diffraction gratings have been simulated and calcu-lated using the 2D finite difference time domain(FDTD)algorithm and the scattering matrix method(SMM).The periods and etch depth of the grating parameters have been optimized.A board area laser diode(BA-LD)with high-order diffraction grat-ings has been designed and fabricated.At output powers up to 10.5 W,the measured spectral width of full width at half maxi-mum(FWHM)is less than 0.5 nm.The results demonstrate that the designed high-order surface gratings can effectively nar-row the spectral width of multimode semiconductor lasers at high output power.展开更多
A novel ridge-waveguide multisection (MS) distributed feedback (DFB) laser, which consists of two identical DFB sections but different ridge widths, is proposed to generate beating-type self-pulsations (SPs). Th...A novel ridge-waveguide multisection (MS) distributed feedback (DFB) laser, which consists of two identical DFB sections but different ridge widths, is proposed to generate beating-type self-pulsations (SPs). The spatiotemporal dynamic response of such a multisection DFB laser is calculated based on a large-signal travelling-wave model. Self-pulsating output at about 150GHz is predicted, and evidences for the beating mechanism of the SPs are provided. To the best of our knowledge, this is the first report on SP generated by MS-DFB lasers with varied ridge width. Compared to other alternatives, such devices are much easier to implement and also enjoy the advantages of lower cost and higher design freedom.展开更多
The aim of this study was to determine the relationship between inter canine width (ICW) and inter alar width (IAW), inter commissural width (ICoW), and inter canthal distance (ICaD) in Bantu population. Materials and...The aim of this study was to determine the relationship between inter canine width (ICW) and inter alar width (IAW), inter commissural width (ICoW), and inter canthal distance (ICaD) in Bantu population. Materials and Methods: It was a pilot study included all participants who were aged at least 18 years, without a history of orthodontics treatment from Prosthodontics Department, Faculty of Dental Medicine, University of Kinshasa. The Ethics committee of the National Center of Research for Dental Sciences in DR Congo approved the study protocol (CNRSB 1504.218). The participants medical records were obtained from the interview and dental examination. Nature of the study was explained with participant information sheet, and an informed consent of all participants was obtained. The inclusion criteria were no missing maxillary and mandibular teeth, no diastema, and no anterior restorations, 18 years old before enrollment in the study. The exclusion criteria were inability to meet the above requirements, pregnancy, and refusal to participate in the study. The inter-canine width (ICW), inter alar width (IAW), inter canthal distance (ICaD) and inter-commissural width (ICoW) of each participant were measured with a digital Vernier caliper (Mitutoyo, UK Ltd.,) (0.01 mm) three times and the average value was recorded. The inter canthal distance (ICaD) was measured without applying pressure by bringing the recording parts of the caliper just in contact with the medial angle. The inter alar width (IAW) was marked with a fine marked pencil on the widest outer surface of the alae of the nose on either side or width. Those two points were measured without applying pressure by bringing the recording parts of the caliper just in contact with the outer surface. The participant was told to stop breathing shortly to avoid any change in shape of the nose. The inter-commissural width (ICoW) was determined by measuring the maxillary lip vermilion from commissure to commissure without the application of pressure on the tissue in the relaxed state. The inter-canine width (ICW) was measured indirectly using a dental floss. A dental floss was marked on one end prior to placement in the mouth. Using that point as reference, the dental floss was circumference along the curvature of the anterior dentition such that it passed along the contact point of all the teeth. The distal end of the canine teeth on both sides was then marked on the floss while it was stretched in the patients mouth. Floss was marked on both sides with the marker pencil. The distance between the two proximal contact points was measured and recorded. Data, analysis and validation were performed by the SPSS software (version 22.0, IBM SPSS Statistics, Chicago, IL, USA). Unpaired t-test was used, of Kolmogorov-Smirnov test. Analysis of variance (ANOVA) test was used to test for comparability between socio-demographic characteristics dental measurements. Pearsons correlation coefficients test was calculated to determine the relationship between facial and dental parameters. Significance was set at P 0.01. Results: Of 314 participants enrolled, 202 were included. The age ranged from 18 to 68 years, with a mean age of 40.62 12.99 years. Although the Pearsons correlation coefficients were negative. Ninety-three participants (46%) were men and one hundred and nine (54%) were women. The overall mean age was 40.62 12.99 years. Facial and dental measurements were greater in women than men with significant differences for ICW (p = 0.04). However, no significant difference was seen between men and women for IAW, ICaD and ICoW (p = 0.44, p = 0.23, p = 0.31 respectively). The correlation including Pearsons correlation coefficient and P-values for all participants is not demonstrated. Conclusion: Within the limitations of this study, the results suggest that IAW, ICaD and ICoW cannot be used as a preliminary method for determining the width of the maxillary for anterior teeth for edentulous patients.展开更多
A wavelength-interval switchable Brillouin–Raman random fiber laser(BRRFL) based on Brillouin pump(BP) manipulation is proposed in this paper. The proposed wavelength-interval switchable BRRFL has a full-open cavity ...A wavelength-interval switchable Brillouin–Raman random fiber laser(BRRFL) based on Brillouin pump(BP) manipulation is proposed in this paper. The proposed wavelength-interval switchable BRRFL has a full-open cavity configuration, featuring multiwavelength output with wavelength interval of double Brillouin frequency shifts. Through simultaneously injecting the BP light and its first-order stimulated Brillouin-scattered light into the cavity, the laser output exhibits a wavelength interval of single Brillouin frequency shift. The wavelength-interval switching effect can be manipulated by controlling the power of the first-order stimulated Brillouin scattering light. The experimental results show the multiwavelength output can be switched between double Brillouin frequency shift multiwavelength emission with a broad bandwidth of approximately 60 nm and single Brillouin frequency shift multiwavelength emission of 44 nm. The flexible optically controlled random fiber laser with switchable wavelength interval makes it useful for a wide range of applications and holds significant potential in the field of wavelength-division multiplexing optical communication.展开更多
Bone cutting is of importance in orthopaedic surgery but is also challenging due to its nature of brittleness—where severe mechanical and thermal damages can be introduced easily in conventional machining.Laser machi...Bone cutting is of importance in orthopaedic surgery but is also challenging due to its nature of brittleness—where severe mechanical and thermal damages can be introduced easily in conventional machining.Laser machining is a new technology that can allow for complex cut geometries whilst minimising surface defects i.e.,smearing,which occur in mechanical methods.However,comparative studies on the influence of lasers with different pulse characteristics on necrotic damage and surface integrity have not been reported yet.This paper for the first time investigates the effects of laser type on the necrotic damage and surface integrity in fresh bovine cortical bone after ex-situ laser machining.Three lasers of different pulse widths,i.e.,picosecond,nanosecond and continuous wave lasers have been investigated with different feed speeds tested to study the machining efficiency.The cutting temperature,and geometrical outputs have been measured to investigate the thermal influence on the cooling behaviour of the bone samples while high-speed imaging was used to compare the material removal mechanisms between a pulsed and continuous wave laser.Furthermore,an in-depth histological analysis of the subsurface has revealed that the nanosecond laser caused the largest necrotic depth,owing to the high pulse frequency limiting the dissipation of heat.It has also been observed that surface cracks positioned perpendicular to the trench direction were produced after machining by the picosecond laser,indicative of the photomechanical effect induced by plasma explosions.Therefore,the choice of laser type(i.e.,in terms of its pulse width and frequency)needs to be critically considered for appropriate application during laser osteotomy with minimum damage and improved healing.展开更多
In this paper we investigate the effects of base width variation on performance of long wavelength transistor laser. In our structure with increasing the base width, the cut off frequency increases until 367 nm with 2...In this paper we investigate the effects of base width variation on performance of long wavelength transistor laser. In our structure with increasing the base width, the cut off frequency increases until 367 nm with 24.5 GHz and then abruptly fall. In 100 nm base width, we have 17.5 GHz cut off frequency, and overall ac performances become optimized, although, other parameters like optical losses and threshold current density are not optimized.展开更多
Near-IR(wavelength≈1μm)laser ablation of bulk,chemically-inert gold in water was compared for different laser pulse width in broad the range of 300 fs–100 ns,comparing a number of key ablation characteristics:mass ...Near-IR(wavelength≈1μm)laser ablation of bulk,chemically-inert gold in water was compared for different laser pulse width in broad the range of 300 fs–100 ns,comparing a number of key ablation characteristics:mass loss,singleshot crater volume and extinction coefficient of the generated colloidal solutions taken in the spectral ranges of interband transitions and localized plasmon resonance.Comparing to related air-based ablation results,at the given fluences laser ablation in the liquid resulted in the maximum ablation yield per unit energy and maximum NP yield per pulse and per unit energy for the picosecond lasers,occurring at subcritical peak pulse powers for laser self-focusing.The self-focusing effect was demonstrated to yield in incomplete,effectively weaker focusing in the water filaments of ultrashort laser pulses with supercritical peak powers,comparing to linear(geometrical)focusing at sub-critical peak powers.At the other,nanosecondpulse extreme the high ablation yield per pulse,but low ablation yield per unit energy and low NP yield per pulse and per unit energy were related to strong ablation plasma screening,providing mass removal according to the well-established scaling relationships for plasma.Illustrative comparison of the ablation and nanoparticle generation efficiency versus the broad fs–ns laser pulse width range was enabled in terms of productivity,economicity,and ergonomicity,using the proposed universal quantitative criteria.展开更多
The phenomenon of a target echo peak overlapping with the backscattered echo peak significantly undermines the detection range and precision of underwater laser fuzes.To overcome this issue,we propose a four-quadrant ...The phenomenon of a target echo peak overlapping with the backscattered echo peak significantly undermines the detection range and precision of underwater laser fuzes.To overcome this issue,we propose a four-quadrant dual-beam circumferential scanning laser fuze to distinguish various interference signals and provide more real-time data for the backscatter filtering algorithm.This enhances the algorithm loading capability of the fuze.In order to address the problem of insufficient filtering capacity in existing linear backscatter filtering algorithms,we develop a nonlinear backscattering adaptive filter based on the spline adaptive filter least mean square(SAF-LMS)algorithm.We also designed an algorithm pause module to retain the original trend of the target echo peak,improving the time discrimination accuracy and anti-interference capability of the fuze.Finally,experiments are conducted with varying signal-to-noise ratios of the original underwater target echo signals.The experimental results show that the average signal-to-noise ratio before and after filtering can be improved by more than31 d B,with an increase of up to 76%in extreme detection distance.展开更多
Recently,the increasing interest in wearable technology for personal healthcare and smart virtual/augmented reality applications has led to the development of facile fabrication methods.Lasers have long been used to d...Recently,the increasing interest in wearable technology for personal healthcare and smart virtual/augmented reality applications has led to the development of facile fabrication methods.Lasers have long been used to develop original solutions to such challenging technological problems due to their remote,sterile,rapid,and site-selective processing of materials.In this review,recent developments in relevant laser processes are summarized under two separate categories.First,transformative approaches,such as for laser-induced graphene,are introduced.In addition to design optimization and the alteration of a native substrate,the latest advances under a transformative approach now enable more complex material compositions and multilayer device configurations through the simultaneous transformation of heterogeneous precursors,or the sequential addition of functional layers coupled with other electronic elements.In addition,the more conventional laser techniques,such as ablation,sintering,and synthesis,can still be used to enhance the functionality of an entire system through the expansion of applicable materials and the adoption of new mechanisms.Later,various wearable device components developed through the corresponding laser processes are discussed,with an emphasis on chemical/physical sensors and energy devices.In addition,special attention is given to applications that use multiple laser sources or processes,which lay the foundation for the all-laser fabrication of wearable devices.展开更多
Laser anti-drone technology is entering the sequence of actual combat,and it is necessary to consider the vulnerability of typical functional parts of UAVs.Since the concept of"vulnerability"was proposed,a v...Laser anti-drone technology is entering the sequence of actual combat,and it is necessary to consider the vulnerability of typical functional parts of UAVs.Since the concept of"vulnerability"was proposed,a variety of analysis programs for battlefield targets to traditional weapons have been developed,but a comprehensive assessment methodology for targets'vulnerability to laser is still missing.Based on the shotline method,this paper proposes a method that equates laser beam to shotline array,an efficient vulnerability analysis program of target to laser is established by this method,and the program includes the circuit board and the wire into the vulnerability analysis category,which improves the precision of the vulnerability analysis.Taking the UAV engine part as the target of vulnerability analysis,combine with the"life-death unit method"to calculate the laser penetration rate of various materials of the UAV,and the influence of laser weapon system parameters and striking orientation on the killing probability is quantified after introducing the penetration rate into the vulnerability analysis program.The quantitative analysis method proposed in this paper has certain general expansibility,which can provide a fresh idea for the vulnerability analysis of other targets to laser.展开更多
BACKGROUND For compensated advanced chronic liver disease(cACLD)patients,the first decompensation represents a dramatically worsening prognostic event.Based on the first decompensation event(DE),the transition to deco...BACKGROUND For compensated advanced chronic liver disease(cACLD)patients,the first decompensation represents a dramatically worsening prognostic event.Based on the first decompensation event(DE),the transition to decompensated advanced chronic liver disease(dACLD)can occur through two modalities referred to as acute decompensation(AD)and non-AD(NAD),respectively.Clinically Significant Portal Hypertension(CSPH)is considered the strongest predictor of decompensation in these patients.However,due to its invasiveness and costs,CSPH is almost never evaluated in clinical practice.Therefore,recognizing noninvasively predicting tools still have more appeal across healthcare systems.The red cell distribution width to platelet ratio(RPR)has been reported to be an indicator of hepatic fibrosis in Metabolic Dysfunction-Associated Steatotic Liver Disease(MASLD).However,its predictive role for the decompensation has never been explored.AIM In this observational study,we investigated the clinical usage of RPR in predicting DEs in MASLD-related cACLD patients.METHODS Fourty controls and 150 MASLD-cACLD patients were consecutively enrolled and followed up(FUP)semiannually for 3 years.At baseline,biochemical,clinical,and Liver Stiffness Measurement(LSM),Child-Pugh(CP),Model for End-Stage Liver Disease(MELD),aspartate aminotransferase/platelet count ratio index(APRI),Fibrosis-4(FIB-4),Albumin-Bilirubin(ALBI),ALBI-FIB-4,and RPR were collected.During FUP,DEs(timing and modaities)were recorded.CSPH was assessed at the baseline and on DE occurrence according to the available Clinical Practice Guidelines.RESULTS Of 150 MASLD-related cACLD patients,43(28.6%)progressed to dACLD at a median time of 28.9 months(29 NAD and 14 AD).Baseline RPR values were significantly higher in cACLD in comparison to controls,as well as MELD,CP,APRI,FIB-4,ALBI,ALBI-FIB-4,and LSM in dACLD-progressing compared to cACLD individuals[all P<0.0001,except for FIB-4(P:0.007)and ALBI(P:0.011)].Receiving operator curve analysis revealed RPR>0.472 and>0.894 as the best cut-offs in the prediction respectively of 3-year first DE,as well as its superiority compared to the other non-invasive tools examined.RPR(P:0.02)and the presence of baseline-CSPH(P:0.04)were significantly and independently associated with the DE.Patients presenting baseline-CSPH and RPR>0.472 showed higher risk of decompensation(P:0.0023).CONCLUSION Altogether these findings suggest the RPR as a valid and potentially applicable non-invasive tool in the prediction of timing and modalities of decompensation in MASLD-related cACLD patients.展开更多
Objective: Flexible ureteroscopy (fURS) has become a widely accepted and effective technique for treating kidney stones. With the development of new laser systems, the fURS approach has evolved significantly. This lit...Objective: Flexible ureteroscopy (fURS) has become a widely accepted and effective technique for treating kidney stones. With the development of new laser systems, the fURS approach has evolved significantly. This literature review aims to examine the current state of knowledge on fURS treatment of kidney stones, with a particular focus on the impact of the latest laser technologies on clinical outcomes and patient safety.Methods: We conducted a search of the PubMed/PMC, Web of Science Core Collection, Scopus, Embase (Ovid), and Cochrane Databases for all randomized controlled trial articles on laser lithotripsy in September 2023 without time restriction.Results: We found a total of 22 relevant pieces of literature. Holmium laser has been used for intracavitary laser lithotripsy for nearly 30 years and has become the golden standard for the treatment of urinary stones. However, the existing holmium laser cannot completely powder the stone, and the retropulsion of the stone after the laser emission and the thermal damage to the tissue have caused many problems for clinicians. The introduction of thulium fiber laser and Moses technology brings highly efficient dusting lithotripsy effect through laser innovation, limiting pulse energy and broadening pulse frequency.Conclusion: While the holmium:yttrium-aluminum-garnet laser remains the primary choice for endoscopic laser lithotripsy, recent technological advancements hint at a potential new gold standard. Parameter range, retropulsion effect, laser fiber adaptability, and overall system performance demand comprehensive attention. The ablation efficacy of high-pulse-frequency devices relies on precise targeting, which may pose practical challenges.展开更多
Memristors as non-volatile memory devices have gained numerous attentions owing to their advantages in storage,in-memory computing, synaptic applications, etc. In recent years, two-dimensional(2D) materials with moder...Memristors as non-volatile memory devices have gained numerous attentions owing to their advantages in storage,in-memory computing, synaptic applications, etc. In recent years, two-dimensional(2D) materials with moderate defects have been discovered to exist memristive feature. However, it is very difficult to obtain moderate defect degree in 2D materials, and studied on modulation means and mechanism becomes urgent and essential. In this work, we realized memristive feature with a bipolar switching and a configurable on/off ratio in a two-terminal MoS_(2) device(on/off ratio ~100), for the first time, from absent to present using laser-modulation to few-layer defect-free MoS_(2)(about 10 layers), and its retention time in both high resistance state and low resistance state can reach 2×10^(4) s. The mechanism of the laser-induced memristive feature has been cleared by dynamic Monte Carlo simulations and first-principles calculations. Furthermore, we verified the universality of the laser-modulation by investigating other 2D materials of TMDs. Our work will open a route to modulate and optimize the performance of 2D semiconductor memristive devices.展开更多
文摘<div style="text-align:justify;"> An intracavity frequency doubling acousto-optically Q-switched Neodymium-doped Yttrium Orthvanadate (Nd:YVO<sub>4</sub>) 457 nm blue laser by employing a three-mirror folded cavity was demonstrated. With the incident pump power of 40.4 W, the maximum average output power of 439 mW 457 nm laser, and the minimum pulse duration of 86.14 ns and the maximum peak power of 510 W were achieved at 10 kHz. The M<sup>2</sup> factors are 1.23 and 1.61 in X and Y directions, respectively. The power stability in two hours is better than 2%. </div>
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 62175116 and 91950105)the 1311 Talent Plan of Nanjing University of Posts and Telecommunications, Chinathe Postgraduate Research & Practice Innovation Program, Jiangsu Province, China (Grant No. SJCX21_0276)
文摘We present a Brillouin–Raman random fiber laser(BRRFL)with full-open linear cavity structure to generate broadband Brillouin frequency comb(BFC)with double Brillouin-frequency-shift spacing.The incorporation of a regeneration portion consisting of an erbium-doped fiber and a single-mode fiber enables the generation of broadband BFC.The dynamics of broadband BFC generation changing with the pump power(EDF and Raman)and Brillouin pump(BP)wavelength are investigated in detail,respectively.Under suitable conditions,the bidirectional BRRFL proposed can produce a flatamplitude BFC with 40.7-nm bandwidth ranging from 1531 nm to 1571.7 nm,and built-in 242-order Brillouin Stokes lines(BSLs)with double Brillouin-frequency-shift spacing.Moreover,the linewidth of single BSL is experimentally measured to be about 2.5 kHz.The broadband bidirectional narrow-linewidth BRRFL has great potential applications in optical communication,optical sensing,spectral measurement,and so on.
文摘We present a detailed study of a combined actively and passively Q-switched (CAPQ) laser with an acousto-optic modulator (AOM) and a codoped Cr^4+, Nd^3+ :YAG crystal The hybrid Q-switch approach is used to produce a short laser pulse with stable and tunable repetition rates. The timing jitter, average pulse width, and average pulse amplitude vary periodically with the AOM modulation frequency under a fixed pump power. The repetition rate of the CAPQ laser can be turned approximately from 4 kHz to 16 kHz with the jitter less than 400 ns.
基金Supported by the National High Technology Research and Development Program of China under Grant No 2014AA041901NSAF Foundation of the National Natural Science Foundation of China under Grant No U1330134+1 种基金the Opening Project of Shanghai Key Laboratory of All Solid-State Laser and Applied Techniques under Grant No 2012ADL02the National Natural Science Foundation of China under Grant Nos 61308024 and 11174305
文摘The wavelength-tunable and switchable narrow bandwidth mode-locking operation is demonstrated in an all fiber laser based on semiconductor-saturable absorber mirror (SESAM). Two narrow-band fiber Bragg gratings centered at 1029.9nm and 1032nm respectively with a polarization controller inserted between them are used to realize the wavelength switchable between 1029.9nm and 1032nm. The laser delivers different pulse widths of 7.5ps for 1030nm and 20ps for 1032nm. The maximum output power for both could reach -6.5mW at single pulse operation. The output wavelength couM be tuned to about 0.gnm intervals ranging from 1030.2nm to 1031.1 nm and from 1032.15nm to 1033.7nm with the temperature change of the fiber Bragg grating, respectively.
基金supported by National Natural Science Foundation of China (Nos. 11502301, 11602304 and 62175260)
文摘In order to optimize the laser ablation performance of a micro-thruster with 1U dimensions,which employs a micro semiconductor laser,the impacts of pulse width and glycidyl azide polymer(GAP)thickness on thrust performance were researched.The results showed that with a GAP thickness of 200μm,the single-pulse impulse(I)increased gradually with the increase in the laser pulse width from 50 to 800μs,while the specific impulse(I_(sp)),impulse coupling coefficient(Cm)and ablation efficiency(η)all reached optimal values with a 200μs pulse width.It is worth noting that the optimal pulse width is identical to the ignition delay time.Both Cmandηpeaked with a pulse width of 200μs,reaching 242.22μN W^(-1)and 35.4%,respectively.With the increase in GAP thickness,I and Cmincreased gradually.GAP of different thicknesses corresponded to different optimal laser pulse widths.Under a certain laser pulse width,the optimal GAP thickness should be the most vertical thickness of the ablation pit,and the various propulsion performance parameters at this time were also optimal.With the current laser parameters,the optimal GAP thickness was approximately 150μm,I_(sp)was approximately 322.22 s,andηwas approximately 34.94%.
基金National Natural Science Foundation of China(No.41871382)Open Foundation of the Key Laboratory of Space Active Opto-electronics Technologyand Chinese Academy of Sciences(No.2018-ZDKF-1)。
文摘The influence of the single photon laser altimeter range-gate width on the detection probability and ranging accuracy is discussed and analyzed,according to the LiDAR equation,single photon detection equation and the Monte Carlo method to simulate the experiment.The simulated results show that the probability of detection is not affected by the range gate,while the probability of false alarm is relative to the gate width.When the gate width is 100 ns,the ranging accuracy can accord with the requirements of satellite laser altimeter.But when the range gate width exceeds 400 ns,ranging accuracy will decline sharply.The noise ratio will be more as long as the range gate to get larger,so the refined filtering algorithm during the data processing is important to extract the useful photons effectively.In order to ensure repeated observation of the same point for 25 times,we deduce the quantitative relation between the footprint size,footprint,and frequency repetition according to the parameters of ICESat-2.The related conclusions can provide some references for the design and the development of the domestic single photon laser altimetry satellite.
基金supported by the National Natural Science Foundation of China(61108078,61450005,81171633,61036014)the Industry Research Special Funds for Public Welfare Projects(2015SQ00057)the Fujian Provincial Natural Science Foundation(2014J07008).
文摘Pulsed and continuous-wave(CW)lasers have been widely used as the light sources for photodynamic therapy(PDT)treatment.Singlet oxygen(^(1)O_(2))is known to be a major cytotoxic agent in type-II PDT and can be directly detected by its near-infrared luminescence at 1270 nm.As compared to CW laser excitation,the effiects of pulse width and repetition rate of pulsed laser on the kinetics and production of^(1)O_(2)luminescence were quantitatively studied during photosensitization of Rose Bengal.Significant di®erence in kinetics of^(1)O_(2)luminescence was found under the excitation with various pulse widths of nanosecond,microsecond and CW irradiation with power of 20mW.The peak intensity and duration of^(1)O_(2)production varied with the pulse widths for pulsed laser excitation,while the^(1)O_(2)was generated continuously and its production reached a steady state with CW excitation.However,no significant di®erence(P>0:05)in integral^(1)O_(2)production was observed.The results suggest that the PDT efficacy using pulsed laser may be identical to the CW laser with the same wavelength and the same average°uence rate below a threshold in solution.
基金supported by the National Key R&D Program of China,No.2022YFB4601201.
文摘The 975 nm multimode diode lasers with high-order surface Bragg diffraction gratings have been simulated and calcu-lated using the 2D finite difference time domain(FDTD)algorithm and the scattering matrix method(SMM).The periods and etch depth of the grating parameters have been optimized.A board area laser diode(BA-LD)with high-order diffraction grat-ings has been designed and fabricated.At output powers up to 10.5 W,the measured spectral width of full width at half maxi-mum(FWHM)is less than 0.5 nm.The results demonstrate that the designed high-order surface gratings can effectively nar-row the spectral width of multimode semiconductor lasers at high output power.
基金Supported by the National Natural Science Foundation of China under Grant Nos 60536020 and 60390074).
文摘A novel ridge-waveguide multisection (MS) distributed feedback (DFB) laser, which consists of two identical DFB sections but different ridge widths, is proposed to generate beating-type self-pulsations (SPs). The spatiotemporal dynamic response of such a multisection DFB laser is calculated based on a large-signal travelling-wave model. Self-pulsating output at about 150GHz is predicted, and evidences for the beating mechanism of the SPs are provided. To the best of our knowledge, this is the first report on SP generated by MS-DFB lasers with varied ridge width. Compared to other alternatives, such devices are much easier to implement and also enjoy the advantages of lower cost and higher design freedom.
文摘The aim of this study was to determine the relationship between inter canine width (ICW) and inter alar width (IAW), inter commissural width (ICoW), and inter canthal distance (ICaD) in Bantu population. Materials and Methods: It was a pilot study included all participants who were aged at least 18 years, without a history of orthodontics treatment from Prosthodontics Department, Faculty of Dental Medicine, University of Kinshasa. The Ethics committee of the National Center of Research for Dental Sciences in DR Congo approved the study protocol (CNRSB 1504.218). The participants medical records were obtained from the interview and dental examination. Nature of the study was explained with participant information sheet, and an informed consent of all participants was obtained. The inclusion criteria were no missing maxillary and mandibular teeth, no diastema, and no anterior restorations, 18 years old before enrollment in the study. The exclusion criteria were inability to meet the above requirements, pregnancy, and refusal to participate in the study. The inter-canine width (ICW), inter alar width (IAW), inter canthal distance (ICaD) and inter-commissural width (ICoW) of each participant were measured with a digital Vernier caliper (Mitutoyo, UK Ltd.,) (0.01 mm) three times and the average value was recorded. The inter canthal distance (ICaD) was measured without applying pressure by bringing the recording parts of the caliper just in contact with the medial angle. The inter alar width (IAW) was marked with a fine marked pencil on the widest outer surface of the alae of the nose on either side or width. Those two points were measured without applying pressure by bringing the recording parts of the caliper just in contact with the outer surface. The participant was told to stop breathing shortly to avoid any change in shape of the nose. The inter-commissural width (ICoW) was determined by measuring the maxillary lip vermilion from commissure to commissure without the application of pressure on the tissue in the relaxed state. The inter-canine width (ICW) was measured indirectly using a dental floss. A dental floss was marked on one end prior to placement in the mouth. Using that point as reference, the dental floss was circumference along the curvature of the anterior dentition such that it passed along the contact point of all the teeth. The distal end of the canine teeth on both sides was then marked on the floss while it was stretched in the patients mouth. Floss was marked on both sides with the marker pencil. The distance between the two proximal contact points was measured and recorded. Data, analysis and validation were performed by the SPSS software (version 22.0, IBM SPSS Statistics, Chicago, IL, USA). Unpaired t-test was used, of Kolmogorov-Smirnov test. Analysis of variance (ANOVA) test was used to test for comparability between socio-demographic characteristics dental measurements. Pearsons correlation coefficients test was calculated to determine the relationship between facial and dental parameters. Significance was set at P 0.01. Results: Of 314 participants enrolled, 202 were included. The age ranged from 18 to 68 years, with a mean age of 40.62 12.99 years. Although the Pearsons correlation coefficients were negative. Ninety-three participants (46%) were men and one hundred and nine (54%) were women. The overall mean age was 40.62 12.99 years. Facial and dental measurements were greater in women than men with significant differences for ICW (p = 0.04). However, no significant difference was seen between men and women for IAW, ICaD and ICoW (p = 0.44, p = 0.23, p = 0.31 respectively). The correlation including Pearsons correlation coefficient and P-values for all participants is not demonstrated. Conclusion: Within the limitations of this study, the results suggest that IAW, ICaD and ICoW cannot be used as a preliminary method for determining the width of the maxillary for anterior teeth for edentulous patients.
基金Poject supported by the National Natural Science Foundation of China(Grant Nos.62175116 and 62311530343)the Postgraduate Research Innovation Program of Jiangsu Province,China(Grant No.KYCX22_0913)。
文摘A wavelength-interval switchable Brillouin–Raman random fiber laser(BRRFL) based on Brillouin pump(BP) manipulation is proposed in this paper. The proposed wavelength-interval switchable BRRFL has a full-open cavity configuration, featuring multiwavelength output with wavelength interval of double Brillouin frequency shifts. Through simultaneously injecting the BP light and its first-order stimulated Brillouin-scattered light into the cavity, the laser output exhibits a wavelength interval of single Brillouin frequency shift. The wavelength-interval switching effect can be manipulated by controlling the power of the first-order stimulated Brillouin scattering light. The experimental results show the multiwavelength output can be switched between double Brillouin frequency shift multiwavelength emission with a broad bandwidth of approximately 60 nm and single Brillouin frequency shift multiwavelength emission of 44 nm. The flexible optically controlled random fiber laser with switchable wavelength interval makes it useful for a wide range of applications and holds significant potential in the field of wavelength-division multiplexing optical communication.
基金The University of Nottingham,the Mexican National Council for Science and Technology(CONACYT)EPSRC through the DTP 2018–19 University of Nottingham(Grant No.EP/T517902/1)Nottingham Research Fellowship and University of Nottingham Propulsion Futures Beacon Programme.
文摘Bone cutting is of importance in orthopaedic surgery but is also challenging due to its nature of brittleness—where severe mechanical and thermal damages can be introduced easily in conventional machining.Laser machining is a new technology that can allow for complex cut geometries whilst minimising surface defects i.e.,smearing,which occur in mechanical methods.However,comparative studies on the influence of lasers with different pulse characteristics on necrotic damage and surface integrity have not been reported yet.This paper for the first time investigates the effects of laser type on the necrotic damage and surface integrity in fresh bovine cortical bone after ex-situ laser machining.Three lasers of different pulse widths,i.e.,picosecond,nanosecond and continuous wave lasers have been investigated with different feed speeds tested to study the machining efficiency.The cutting temperature,and geometrical outputs have been measured to investigate the thermal influence on the cooling behaviour of the bone samples while high-speed imaging was used to compare the material removal mechanisms between a pulsed and continuous wave laser.Furthermore,an in-depth histological analysis of the subsurface has revealed that the nanosecond laser caused the largest necrotic depth,owing to the high pulse frequency limiting the dissipation of heat.It has also been observed that surface cracks positioned perpendicular to the trench direction were produced after machining by the picosecond laser,indicative of the photomechanical effect induced by plasma explosions.Therefore,the choice of laser type(i.e.,in terms of its pulse width and frequency)needs to be critically considered for appropriate application during laser osteotomy with minimum damage and improved healing.
文摘In this paper we investigate the effects of base width variation on performance of long wavelength transistor laser. In our structure with increasing the base width, the cut off frequency increases until 367 nm with 24.5 GHz and then abruptly fall. In 100 nm base width, we have 17.5 GHz cut off frequency, and overall ac performances become optimized, although, other parameters like optical losses and threshold current density are not optimized.
基金the Ministry of Science and Higher Education of the Russian Federation(Project No.075-152020-775)。
文摘Near-IR(wavelength≈1μm)laser ablation of bulk,chemically-inert gold in water was compared for different laser pulse width in broad the range of 300 fs–100 ns,comparing a number of key ablation characteristics:mass loss,singleshot crater volume and extinction coefficient of the generated colloidal solutions taken in the spectral ranges of interband transitions and localized plasmon resonance.Comparing to related air-based ablation results,at the given fluences laser ablation in the liquid resulted in the maximum ablation yield per unit energy and maximum NP yield per pulse and per unit energy for the picosecond lasers,occurring at subcritical peak pulse powers for laser self-focusing.The self-focusing effect was demonstrated to yield in incomplete,effectively weaker focusing in the water filaments of ultrashort laser pulses with supercritical peak powers,comparing to linear(geometrical)focusing at sub-critical peak powers.At the other,nanosecondpulse extreme the high ablation yield per pulse,but low ablation yield per unit energy and low NP yield per pulse and per unit energy were related to strong ablation plasma screening,providing mass removal according to the well-established scaling relationships for plasma.Illustrative comparison of the ablation and nanoparticle generation efficiency versus the broad fs–ns laser pulse width range was enabled in terms of productivity,economicity,and ergonomicity,using the proposed universal quantitative criteria.
基金supported by the 2021 Open Project Fund of Science and Technology on Electromechanical Dynamic Control Laboratory,grant number 212-C-J-F-QT-2022-0020China Postdoctoral Science Foundation,grant number 2021M701713+1 种基金Postgraduate Research&Practice Innovation Program of Jiangsu Province,grant number KYCX23_0511the Jiangsu Funding Program for Excellent Postdoctoral Talent,grant number 20220ZB245。
文摘The phenomenon of a target echo peak overlapping with the backscattered echo peak significantly undermines the detection range and precision of underwater laser fuzes.To overcome this issue,we propose a four-quadrant dual-beam circumferential scanning laser fuze to distinguish various interference signals and provide more real-time data for the backscatter filtering algorithm.This enhances the algorithm loading capability of the fuze.In order to address the problem of insufficient filtering capacity in existing linear backscatter filtering algorithms,we develop a nonlinear backscattering adaptive filter based on the spline adaptive filter least mean square(SAF-LMS)algorithm.We also designed an algorithm pause module to retain the original trend of the target echo peak,improving the time discrimination accuracy and anti-interference capability of the fuze.Finally,experiments are conducted with varying signal-to-noise ratios of the original underwater target echo signals.The experimental results show that the average signal-to-noise ratio before and after filtering can be improved by more than31 d B,with an increase of up to 76%in extreme detection distance.
基金supported by the Basic Research Program through the National Research Foundation of Korea(NRF)(Nos.2022R1C1C1006593,2022R1A4A3031263,and RS-2023-00271166)the National Science Foundation(Nos.2054098 and 2213693)+1 种基金the National Natural Science Foundation of China(No.52105593)Zhejiang Provincial Natural Science Foundation of China(No.LDQ24E050001).EH acknowledges a fellowship from the Hyundai Motor Chung Mong-Koo Foundation.
文摘Recently,the increasing interest in wearable technology for personal healthcare and smart virtual/augmented reality applications has led to the development of facile fabrication methods.Lasers have long been used to develop original solutions to such challenging technological problems due to their remote,sterile,rapid,and site-selective processing of materials.In this review,recent developments in relevant laser processes are summarized under two separate categories.First,transformative approaches,such as for laser-induced graphene,are introduced.In addition to design optimization and the alteration of a native substrate,the latest advances under a transformative approach now enable more complex material compositions and multilayer device configurations through the simultaneous transformation of heterogeneous precursors,or the sequential addition of functional layers coupled with other electronic elements.In addition,the more conventional laser techniques,such as ablation,sintering,and synthesis,can still be used to enhance the functionality of an entire system through the expansion of applicable materials and the adoption of new mechanisms.Later,various wearable device components developed through the corresponding laser processes are discussed,with an emphasis on chemical/physical sensors and energy devices.In addition,special attention is given to applications that use multiple laser sources or processes,which lay the foundation for the all-laser fabrication of wearable devices.
基金National Natural Science Foundation of China(Grant Nos.62005276,62175234)the Scientific and Technological Development Program of Jilin,China(Grant No.20230508111RC)to provide fund for this research。
文摘Laser anti-drone technology is entering the sequence of actual combat,and it is necessary to consider the vulnerability of typical functional parts of UAVs.Since the concept of"vulnerability"was proposed,a variety of analysis programs for battlefield targets to traditional weapons have been developed,but a comprehensive assessment methodology for targets'vulnerability to laser is still missing.Based on the shotline method,this paper proposes a method that equates laser beam to shotline array,an efficient vulnerability analysis program of target to laser is established by this method,and the program includes the circuit board and the wire into the vulnerability analysis category,which improves the precision of the vulnerability analysis.Taking the UAV engine part as the target of vulnerability analysis,combine with the"life-death unit method"to calculate the laser penetration rate of various materials of the UAV,and the influence of laser weapon system parameters and striking orientation on the killing probability is quantified after introducing the penetration rate into the vulnerability analysis program.The quantitative analysis method proposed in this paper has certain general expansibility,which can provide a fresh idea for the vulnerability analysis of other targets to laser.
文摘BACKGROUND For compensated advanced chronic liver disease(cACLD)patients,the first decompensation represents a dramatically worsening prognostic event.Based on the first decompensation event(DE),the transition to decompensated advanced chronic liver disease(dACLD)can occur through two modalities referred to as acute decompensation(AD)and non-AD(NAD),respectively.Clinically Significant Portal Hypertension(CSPH)is considered the strongest predictor of decompensation in these patients.However,due to its invasiveness and costs,CSPH is almost never evaluated in clinical practice.Therefore,recognizing noninvasively predicting tools still have more appeal across healthcare systems.The red cell distribution width to platelet ratio(RPR)has been reported to be an indicator of hepatic fibrosis in Metabolic Dysfunction-Associated Steatotic Liver Disease(MASLD).However,its predictive role for the decompensation has never been explored.AIM In this observational study,we investigated the clinical usage of RPR in predicting DEs in MASLD-related cACLD patients.METHODS Fourty controls and 150 MASLD-cACLD patients were consecutively enrolled and followed up(FUP)semiannually for 3 years.At baseline,biochemical,clinical,and Liver Stiffness Measurement(LSM),Child-Pugh(CP),Model for End-Stage Liver Disease(MELD),aspartate aminotransferase/platelet count ratio index(APRI),Fibrosis-4(FIB-4),Albumin-Bilirubin(ALBI),ALBI-FIB-4,and RPR were collected.During FUP,DEs(timing and modaities)were recorded.CSPH was assessed at the baseline and on DE occurrence according to the available Clinical Practice Guidelines.RESULTS Of 150 MASLD-related cACLD patients,43(28.6%)progressed to dACLD at a median time of 28.9 months(29 NAD and 14 AD).Baseline RPR values were significantly higher in cACLD in comparison to controls,as well as MELD,CP,APRI,FIB-4,ALBI,ALBI-FIB-4,and LSM in dACLD-progressing compared to cACLD individuals[all P<0.0001,except for FIB-4(P:0.007)and ALBI(P:0.011)].Receiving operator curve analysis revealed RPR>0.472 and>0.894 as the best cut-offs in the prediction respectively of 3-year first DE,as well as its superiority compared to the other non-invasive tools examined.RPR(P:0.02)and the presence of baseline-CSPH(P:0.04)were significantly and independently associated with the DE.Patients presenting baseline-CSPH and RPR>0.472 showed higher risk of decompensation(P:0.0023).CONCLUSION Altogether these findings suggest the RPR as a valid and potentially applicable non-invasive tool in the prediction of timing and modalities of decompensation in MASLD-related cACLD patients.
基金supported by the 1.3.5 Project for Disciplines of Excellence,West China Hospital,Sichuan University(Grant No.ZYGD18011 and No.ZYJC18015 to Wang K).
文摘Objective: Flexible ureteroscopy (fURS) has become a widely accepted and effective technique for treating kidney stones. With the development of new laser systems, the fURS approach has evolved significantly. This literature review aims to examine the current state of knowledge on fURS treatment of kidney stones, with a particular focus on the impact of the latest laser technologies on clinical outcomes and patient safety.Methods: We conducted a search of the PubMed/PMC, Web of Science Core Collection, Scopus, Embase (Ovid), and Cochrane Databases for all randomized controlled trial articles on laser lithotripsy in September 2023 without time restriction.Results: We found a total of 22 relevant pieces of literature. Holmium laser has been used for intracavitary laser lithotripsy for nearly 30 years and has become the golden standard for the treatment of urinary stones. However, the existing holmium laser cannot completely powder the stone, and the retropulsion of the stone after the laser emission and the thermal damage to the tissue have caused many problems for clinicians. The introduction of thulium fiber laser and Moses technology brings highly efficient dusting lithotripsy effect through laser innovation, limiting pulse energy and broadening pulse frequency.Conclusion: While the holmium:yttrium-aluminum-garnet laser remains the primary choice for endoscopic laser lithotripsy, recent technological advancements hint at a potential new gold standard. Parameter range, retropulsion effect, laser fiber adaptability, and overall system performance demand comprehensive attention. The ablation efficacy of high-pulse-frequency devices relies on precise targeting, which may pose practical challenges.
基金supported by the National Natural Science Foundation of China(Nos.51971070,10974037,and 62205011)the National Key Research and Development Program of China(No.2016YFA0200403)+6 种基金Eu-FP7 Project(No.247644)CAS Strategy Pilot Program(No.XDA 09020300)Fundamental Research Funds for the Central Universities(No.buctrc202122)the Open Research Project of Zhejiang province Key Laboratory of Quantum Technology and Device(No.20220401)the Open Research Project of Special Display and Imaging Technology Innovation Center of Anhui Province(No.2022AJ05001)funded by the Ph.D Foundation of Hebei University of Water Resources and Electric Engineering(No.SYBJ2202)Funded by Science and Technology Project of Hebei Education Department(No.BJK2022027)。
文摘Memristors as non-volatile memory devices have gained numerous attentions owing to their advantages in storage,in-memory computing, synaptic applications, etc. In recent years, two-dimensional(2D) materials with moderate defects have been discovered to exist memristive feature. However, it is very difficult to obtain moderate defect degree in 2D materials, and studied on modulation means and mechanism becomes urgent and essential. In this work, we realized memristive feature with a bipolar switching and a configurable on/off ratio in a two-terminal MoS_(2) device(on/off ratio ~100), for the first time, from absent to present using laser-modulation to few-layer defect-free MoS_(2)(about 10 layers), and its retention time in both high resistance state and low resistance state can reach 2×10^(4) s. The mechanism of the laser-induced memristive feature has been cleared by dynamic Monte Carlo simulations and first-principles calculations. Furthermore, we verified the universality of the laser-modulation by investigating other 2D materials of TMDs. Our work will open a route to modulate and optimize the performance of 2D semiconductor memristive devices.