期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Proposed Methodology for Generation of Building Information Model with Laserscanning
1
作者 Jrg Isele Georg Bretthauer 《Tsinghua Science and Technology》 SCIE EI CAS 2008年第S1期138-144,共7页
For refurbishment and state review of an existing old building, a new model reflecting the current state is often required especially when the original plans are no longer accessible. Laser scanners are used more and ... For refurbishment and state review of an existing old building, a new model reflecting the current state is often required especially when the original plans are no longer accessible. Laser scanners are used more and more as surveying instruments for various applications because of their high-precision scanning abilities. For buildings, the most notable and widely accepted product data model is the IFC product data model. It is designed to cover the whole lifecycle and supported by various software vendors and enables applications to efficiently share and exchange project information. The models obtained with the laser scanner, normally sets of points ('point cloud'), have to be transferred to an IFC compatible building information model to serve the needs of different planning states. This paper presents an approach designed by the German Research Center in Karlsruhe (Forschungszentrum Karlsruhe) to create an IFC compatible building information model from laser range images. The methodology through the entire process from data acquisition to the IFC compatible product model was proposed in this paper. In addition, IFC-Models with different level of detail (LoDs) were introduced and discussed within the work. 展开更多
关键词 laserscanning building information model (BIM) industry foundation classes (IFC) object rec-ognition simultaneous localization and mapping (SLAM)
原文传递
用LASERSCAN激光细度测定仪和显微投影仪对羊毛细度检测结果的比对分析 被引量:2
2
作者 郭天芬 高雅琴 +2 位作者 常玉兰 牛春娥 李维红 《中国草食动物》 2007年第z1期95-97,共3页
关键词 细度测定仪 显微投影仪 激光细度仪 LASERSCAN 检测结果 比对分析
下载PDF
国产化全自动纤维细度测试仪的应用与试验分析 被引量:1
3
作者 邓瑾 陈忠雄 +2 位作者 戴先礼 冯雷 姜峰 《中国纤检》 2011年第7期54-56,共3页
本文利用进口的LASERSCAN激光细度仪与国产自主研发的BEION F10全自动细度仪进行羊毛纤维细度自动测试的对比试验,并对试验结果进行分析。通过试验分析:在标准实验室环境条件下,利用这两种仪器分别对国际毛纺协会实验室提供的八组标准... 本文利用进口的LASERSCAN激光细度仪与国产自主研发的BEION F10全自动细度仪进行羊毛纤维细度自动测试的对比试验,并对试验结果进行分析。通过试验分析:在标准实验室环境条件下,利用这两种仪器分别对国际毛纺协会实验室提供的八组标准毛条样本和用户提供的毛条中随机选取的15个样本的平行试验结果远小于国家相关标准所规定的误差;在置信度为99%时,无显著性差异。 展开更多
关键词 LASERSCAN激光细度仪 BEION F10全自动细度仪 羊毛细度 对比试验 显著性检验
下载PDF
THE ROLES OF REACTION INHOMOGENEITY IN PHASE SEPARATION KINETICS AND MORPHOLOGY OF REACTIVE POLYMER BLENDS
4
作者 Qui Tran-Cong-Miyata Dan-Thuy Van-Pham +2 位作者 Kei Noma Tomohisa Norisuye Hideyuki Nakanishi 《Chinese Journal of Polymer Science》 SCIE CAS CSCD 2009年第1期23-36,共14页
The roles of reaction inhomogeneity in phase separation of polymer mixtures were described and summarized via two examples:photocross-link of polymer mixtures in the bulk state and photopolymerization of monomer in th... The roles of reaction inhomogeneity in phase separation of polymer mixtures were described and summarized via two examples:photocross-link of polymer mixtures in the bulk state and photopolymerization of monomer in the liquid state. The reaction kinetics,the reaction-induced elastic strain and the phase separation kinetics were monitored respectively by UV-Vis spectroscopy,Mach-Zehnder interferometry and laser-scanning confocal microscopy.It was found that phase separation in the bulk state was strongly inf... 展开更多
关键词 Photo-crosslink reaction Phase separation Reaction-induced deformation Mach-Zehnder interferometry laserscanning confocal microscopy
下载PDF
Effect of the Minimum Diameter and Its Relevant Parameters on Wool Quality
5
作者 于伟东 《Journal of Donghua University(English Edition)》 EI CAS 2003年第3期11-15,共5页
It is important to measure wool diameter as the wool quality depends on the fibre diameter D and its deviation CVD. According to IWTO standards, the fibre diameter parameters can be tested with the methods of Airflowm... It is important to measure wool diameter as the wool quality depends on the fibre diameter D and its deviation CVD. According to IWTO standards, the fibre diameter parameters can be tested with the methods of Airflowmeter, DA; Sirolan-Laserscan, DL and CVDL; and OFDA, Do and CVDo. However, these parameters only characterize the average diameter and the variation between the fibres. A single fibre analyzer (SIFAN) can be used to measure fibre profile along the fibre and fibre tensile properties simultaneously. The results obtained from the four methods show that there are i) high relationships between Laserscan values and the results of Airflow, OFDA and SIFAN in the average diameters; ii) correlations between CVDL and CVDo or CVDave; iii) the high correlation between Dave-Dmia but a low correlation between Dave-Dmax; and iv) the relationships between the wool quality and the ratio of Dmln/Dave and Dmin/DL. Based on the results and discussions, the effective measurement of wool diameter should be the SIFAN method. The new parameters of Dmin/DL and Dmin/Dave are the useful value for the evaluation of wool quality in practice. 展开更多
关键词 Fibre diameter WOOL AIRFLOW S1FAN OFDA Laserscan
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部