An anomalous total dose effect that the long length device is more susceptible to total ionizing dose than the short one is observed with the 0.13?μm partially depleted silicon-on-insulator technology. The measured ...An anomalous total dose effect that the long length device is more susceptible to total ionizing dose than the short one is observed with the 0.13?μm partially depleted silicon-on-insulator technology. The measured results and 3D technology computer aided design simulations demonstrate that the devices with different channel lengths may exhibit an enhanced reverse short channel effect after radiation. It is ascribed to that the halo or pocket implants introduced in processes results in non-uniform channel doping profiles along the device length and trapped charges in the shallow trench isolation regions.展开更多
A study of the quenching of pyrene fluorescence by a series of alkyltriphenylphosphonium bromides indi- cated the coiling conformation of ionic surfactant in aqueous solution.Formation of pyrene excimer in cetyltriph-...A study of the quenching of pyrene fluorescence by a series of alkyltriphenylphosphonium bromides indi- cated the coiling conformation of ionic surfactant in aqueous solution.Formation of pyrene excimer in cetyltriph- enylphosphonium solution strengthened the conclusion.展开更多
For different external cavity lengths, lasing wavelength variation of fiber grating external cavity semiconductor laser (FGECSL) with ambient temperature has been investigated theoretically, and the theoretical result...For different external cavity lengths, lasing wavelength variation of fiber grating external cavity semiconductor laser (FGECSL) with ambient temperature has been investigated theoretically, and the theoretical results are in agreement with reported experimental observations.展开更多
基金Supported by the Weapon Equipment Pre-Research Foundation of China under Grant No 9140A11020114ZK34147the Shanghai Municipal Natural Science Foundation under Grant Nos 15ZR1447100 and 15ZR1447200
文摘An anomalous total dose effect that the long length device is more susceptible to total ionizing dose than the short one is observed with the 0.13?μm partially depleted silicon-on-insulator technology. The measured results and 3D technology computer aided design simulations demonstrate that the devices with different channel lengths may exhibit an enhanced reverse short channel effect after radiation. It is ascribed to that the halo or pocket implants introduced in processes results in non-uniform channel doping profiles along the device length and trapped charges in the shallow trench isolation regions.
文摘A study of the quenching of pyrene fluorescence by a series of alkyltriphenylphosphonium bromides indi- cated the coiling conformation of ionic surfactant in aqueous solution.Formation of pyrene excimer in cetyltriph- enylphosphonium solution strengthened the conclusion.
文摘For different external cavity lengths, lasing wavelength variation of fiber grating external cavity semiconductor laser (FGECSL) with ambient temperature has been investigated theoretically, and the theoretical results are in agreement with reported experimental observations.