Visual function and higher order aberration after implantation of aspheric and spherical multifocal intraocular lenses:a meta-analysis 被引量:6
1
作者 Jian-Ping Liu Fan Zhang +2 位作者 Jiang-Yue Zhao Li-Wei Ma Jin-Song Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第5期690-695,共6页
AIMTo assess the visual outcomes of aspheric multifocal intraocular lenses (IOLs) compared with spherical multifocal IOL after cataract surgery.
关键词 aspheric multifocal intraocular lens uncorrected near visual acuity uncorrected distance visual acuity spherical multifocal intraocular lens higher order aberration META-ANALYSIS
下载PDF
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
2
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
下载PDF
Higher order aberration comparison between two aspherical intraocular lenses: MC6125AS and Akreos advanced optics 被引量:5
3
作者 Mohammad Taher Rajabi Sara Korouji +4 位作者 Mahgol Farjadnia Mohammad Naderan Mohammad Bagher Rajabi Bahram Khosravi Seyed Mehdi Tabatabaie 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第3期565-568,共4页
AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty... AIM: To compare higher order aberrations in two aspherical intraocular lenses(IOLs): Akreos advanced optics(AO) and Dr. Schmidt Microcrystalline 6125 aspheric anterior surface(MC6125AS) with each other. METHODS: Forty eyes of 39 patients underwent phacoemulsification and Akreos AO and MC6125 AS were implanted in their eyes in a random manner. Three months post-operatively, higher order aberrations including spherical aberration, coma aberration, and total aberrations were measured and compared.RESULTS: The total aberration was 0.24±0.17 in eyes with Dr. Schmidt and 0.20 ±0.01 in eyes with Akreos AO(P =0.361). The mean of coma aberration was 0.17 ±0.21 and 0.09 ±0.86 in Dr. Schmidt and Akreos lenses,respectively(P =0.825). Total spherical aberration was almost the same in both groups(mean: 0.05, P =0.933).Best corrected visual acuity in Akreos AO(0.10±0.68) and Dr. Schmidt(0.09±0.67) did not differ significantly(P =0.700). CONCLUSION: There is no statistically significant difference in the higher order aberrations between these two aspherical lenses. 展开更多
关键词 aspherical lenses higher order aberrations CATARACT intraocular lens
下载PDF
Changes in visual performance after implantation of different intraocular lenses
4
作者 Bo-Wen Li Hao Huang +10 位作者 Man-Sha Huang Shuang-Lin Guo Lu Gao Yu-Ying Zeng Lu Cheng Si-Yang Yao Jian-Qiang Lin Lin Liu Ye Yang Xiao-Ming Lu Hao Cheng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1273-1282,共10页
AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmenta... AIM:To evaluate the trending visual performance of different intraocular lenses(IOLs)over time after implantation.METHODS:Ninety-one patients received cataract surgery with implantations of monofocal(Mon)IOLs,segmental refractive(SegRef)IOLs,diffractive(Dif)IOLs,and extendeddepth-of-focus(EDoF)IOLs were included.The aberrations and optical quality collected with iTrace and OQAS within postoperative 6mo were followed and compared.RESULTS:Most of the visual parameters improved over the postoperative 6mo.The postoperative visual acuity(POVA)of the Mon IOL,SegRef IOL,and EDoF IOL groups achieved relative stability in earlier states compared with the Dif IOL group.Nevertheless,the overall visual performance of the 3 IOLs continued to upturn in small extents within the postoperative 6mo.The optical quality initially improved in the EDoF IOL group,then in the Mon IOL,SegRef IOL,and Dif IOL groups.POVA and objective visual performance of the Mon IOL and EDoF IOL groups,as well as POVA and visual quality of the Dif IOL group,improved in the postoperative 1mo and stabilized.Within the postoperative 6mo,gradual improvements were observed in the visual acuity and objective visual performance of the SegRef IOL group,as well as in the postoperative optical quality of the Dif IOL group.CONCLUSION:The visual performance is different among eyes implanted with different IOLs.The findings of the current study provide a potential reference for ophthalmologists to choose suitable IOLs for cataract patients in a personalized solution. 展开更多
关键词 intraocular lenses visual performance changing characteristics high-order wavefront aberration
下载PDF
Evaluation of visual quality of spherical and aspherical intraocular lenses by Optical Quality Analysis System 被引量:11
5
作者 Yan Chen Xue Wang +1 位作者 Chuan-Di Zhou Qiang Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第6期914-918,共5页
AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four ... AIM: To evaluate the impact of spherical and aspherical intraocular lenses on the postoperative visual quality of age-related cataract patients using Optical Quality Analysis System (OQAS). METHODS: Seventy-four eyes with age-related cataracts were randomly divided into spherical and aspherical lens implantation groups. Best-corrected visual acuity (BCVA) was measured preoperatively, one day, one week, two weeks, one month and two months after surgery. A biometric systems analysis using the OQAS objective scattering index (OSI) was performed. RESULTS: There were no significant differences in visual acuity (P〉0.05) before and after spherical and aspheric lens implantation. There was a negative linear correction between the OSI value and BCVA (t-=-0.634, P=-0.000), and positive corrections between the OSI value and the lens LOCUS III value of nucleus color (NC), nucleus opacity (NO), cortex (C) and posterior lens capsular (P) (r=0.704, P=0.000; r=0.514, P=0.000; r=0.276, P=0.020; r=0.417, P=-0.000, respectively). OSI values of spherical vs aspherical lenses were 11.5±3.6 vs 11.8±3.4, 4.1±0.9 vs 3.3±0.8, 3.5±0.9 vs 2.7±0.7, 3.3±0.8 vs 2.6±0.7, 3.2±0.7 vs 2.5±0.8, and 3.2±0.8 vs 2.50.8 before and ld, 1, 2wk, 1 and 2mo after surgery, respectively. All time points varied significantly (P〈0.01) between the two groups. CONCLUSION: Aspherical IOLs does not significantly affect visual acuity compared with spherical IOLs. The OSI value, was significantly lower in the aspherical lens group compared with the spherical lens. This study shows that objective visual quality of aspheric IOLs is better than that of the spherical lens by means of OQAS biological measurement method. 展开更多
关键词 optical quality analysis system age-relatedcataract spherical lens aspherical lens objective scatteringindex
下载PDF
Visual outcome and optical quality after bilateral implantation of aspheric diffractive multifocal, aspheric monofocal and spherical monofocal intraocular lenses: a prospective comparison 被引量:5
6
作者 Pan-Pan Ye Xia Li Ke Yao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2013年第3期300-306,共7页
·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ... ·AIM: To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs). ·METHODS: Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively: monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) for distance, intermediate and near, spherical aberration (SA), contrast and glare sensitivity, near point refractive power, uncorrected and best corrected near stereoscopic acuity (NSA). Patient satisfaction was assessed by a questionnaire. ·RESULTS:Threemonthspostoperatively,themonocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups. ·CONCLUSION: Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractive power than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo. · 展开更多
关键词 intraocular lens ABERRATION visual acuity MULTIFOCAL
下载PDF
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
7
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
下载PDF
Considerations in the management of single-piece intraocular lenses outside the capsular bag
8
作者 Anna K Junk 《World Journal of Ophthalmology》 2014年第3期87-91,共5页
AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who... AIM: To investigate the outcomes of off label singlepiece acrylic intraocular lenses(SPA-IOL) ciliary sulcus placement compared to three-piece IOL(3P-IOL). METHODS: The charts of eight consecutive eyes of patients who received sulcus-placed SPA-IOLs between 2006 and 2009 were reviewed. None of the patients underwent IOL exchange. Charts of six age-matched patients who received sulcus placed 3P-IOLs were reviewed as a control group. RESULTS: Mean follow up was 16 mo for SPA-IOL and 23 mo for 3P-IOL. Five of 8 patients in the SPA-IOL group required chronic use of IOP lowering medications at final follow up. Of these, one patient needed glaucoma implant surgery for uncontrolled IOP. One patient in the 3P-IOL group used chronic aqueous suppression pre- and postoperatively. Four of eight eyes with SPAIOL were treated with chronic topical steroids and or non-steroidal anti-inflammatory drugs for cystoid macu-la edema, chronic uveitis, pigment dispersion syndrome or a combination of the above, compared to none in the control group. Mean best-corrected visual acuity was 20/35 in the SPA-IOL group and 20/47 in the 3PIOL group.CONCLUSION: Sulcus placed SPA-IOLs are associated with increased ocular morbidity. In select cases good visual acuity may be achieved. Due to postoperative rotation of sulcus placed toric SPA-IOLs stable astigmatism correction cannot be achieved. Alternative intraocular lenses should be considered when in-the-bag placement of SPA-IOL is not possible. 展开更多
关键词 Cataract surgery Sulcus intraocular lens implant Single piece intraocular lenses Three piece intraocular lenses Posterior capsule tear Cataract surgery complication Pigment dispersion Cystoid macula edema Anterior vitrectomy
下载PDF
Flapless one-knot suture:a novel surgical technique for transscleral fixation of C-loop intraocular lenses
9
作者 Qing-Qing Long Bao-Jiang Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第5期736-742,共7页
AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectiv... AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique. 展开更多
关键词 C-loop intraocular lens implantation lens dislocation transscleral fixation four-haptics intraocular lens
下载PDF
A new software for automated counting of glistenings in intraocular lenses in vivo
10
作者 Nick Stanojcic Christopher C.Hull +2 位作者 Eduardo Mangieri Nathan Little David O’Brart 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1237-1242,共6页
AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually an... AIM:To assess the performance of a bespoke software for automated counting of intraocular lens(IOL)glistenings in slit-lamp images.METHODS:IOL glistenings from slit-lamp-derived digital images were counted manually and automatically by the bespoke software.The images of one randomly selected eye from each of 34 participants were used as a training set to determine the threshold setting that gave the best agreement between manual and automatic grading.A second set of 63 images,selected using randomised stratified sampling from 290 images,were used for software validation.The images were obtained using a previously described protocol.Software-derived automated glistenings counts were compared to manual counts produced by three ophthalmologists.RESULTS:A threshold value of 140 was determined that minimised the total deviation in the number of glistenings for the 34 images in the training set.Using this threshold value,only slight agreement was found between automated software counts and manual expert counts for the validating set of 63 images(κ=0.104,95%CI,0.040-0.168).Ten images(15.9%)had glistenings counts that agreed between the software and manual counting.There were 49 images(77.8%)where the software overestimated the number of glistenings.CONCLUSION:The low levels of agreement show between an initial release of software used to automatically count glistenings in in vivo slit-lamp images and manual counting indicates that this is a non-trivial application.Iterative improvement involving a dialogue between software developers and experienced ophthalmologists is required to optimise agreement.The results suggest that validation of software is necessary for studies involving semi-automatic evaluation of glistenings. 展开更多
关键词 new software automated counting glistenings intraocular lenses slit-lamp images
下载PDF
Rotational stability of plate haptic toric intraocular lenses after combined 25-gauge vitrectomy and cataract surgery
11
作者 Lara Buhl Julian Langer +3 位作者 Stefan Kassumeh Thomas C.Kreutzer Wolfgang J.Mayer Siegfried G.Priglinger 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1231-1236,共6页
AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL... AIM:To evaluate the postoperative intraocular lens(IOL)rotational stability and residual refractive astigmatism following combined 25-gauge vitrectomy and cataract surgery with implantation of a plate haptic toric IOL.METHODS:In this retrospective case series,32 eyes of 32 patients underwent a combined 25-gauge vitrectomy and phacoemulsification for vitreoretinal diseases and cataract with regular corneal astigmatism of at least 1 diopter(D).A plate haptic toric IOL(AT Torbi 709M,Carl Zeiss Meditec AG)was implanted in all eyes.The outcome measures were rotational stability and refractive astigmatism up to 6mo postoperatively as well as the best corrected visual acuity(BCVA).RESULTS:Preoperative refractive astigmatism was 2.14±1.17 D,which was significantly reduced to 0.77±0.37 D six to eight weeks postoperatively and remained stable throughout the observation period(0.67±0.44 D at three months and 0.75±0.25 D at six months;for all groups:P<0.0001 compared to baseline).BCVA improved significantly from 0.36±0.33 logMAR preoperatively to 0.10±0.15 logMAR following surgery(P=0.02).Mean IOL axis deviation from the target axis was 3.4°±2.9°after six to eight weeks and significantly decreased over time(2.4°±2.6°six months after surgery;P=0.04).In one patient IOL,re-alignment was performed.CONCLUSION:Corneal astigmatism is significantly reduced following combined 25-gauge vitrectomy and cataract surgery.The plate haptic toric IOL position and axis remain stable during the observation period of six months. 展开更多
关键词 combined phaco-vitrectomy toric intraocular lens rotational stability corneal astigmatism CATARACT vitreoretinal disease
下载PDF
Above-average defocus curves in photopic and mesopic vision with multifocal intraocular lenses after laser assisted in situ keratomileusis
12
作者 Joaquín Fernández Manuel Rodríguez-Vallejo +2 位作者 Javier Martínez Ana Tauste David P Pi?ero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1620-1623,共4页
I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qv... I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qvision) hospitals in Spain. 展开更多
关键词 Figure LASIK Above-average defocus curves in photopic and mesopic vision with multifocal intraocular lenses after laser assisted in situ keratomileusis IOL
下载PDF
Multifocal and extended depth of focus intraocular lenses
13
作者 Georgios Kondylis Olga Klavdianou Sotiria Palioura 《Annals of Eye Science》 2019年第1期13-18,共6页
Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number... Advances in intraocular lens(IOL)design have rendered cataract surgery a refractive procedure.Newer IOL types include bifocal,trifocal and extended depth of focus(EDOF)IOLs.Their basic difference nestles in the number of focal points that each lens provides,which in turn leads to different visual outcomes.Familiarity of surgeons with the various characteristics of each lens is of utmost importance for accurate IOL selection to match each patient’s needs.In this review,we aim to compare the clinical outcomes after implantation of multifocal and EDOF IOLs in terms of distance,intermediate and near vision,contrast sensitivity,and reading performance.Finally,we discuss the defocus curve and the optical and photic phenomena associated with each type of IOL. 展开更多
关键词 Cataract surgery quality of vision intraocular lens implantation trifocal intraocular lens bifocal intraocular lens
下载PDF
Distance vision after bilateral implantation of AcrySof toric intraocular lenses:a randomized,controlled,prospective trial 被引量:4
14
作者 Jin-Song Zhang Jiang-Yue Zhao +1 位作者 Qi Sun and Li-Wei Ma 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2011年第2期175-178,共4页
关键词 ASTIGMATISM cataract extraction lenses intraocular PSEUDOPHAKIA
下载PDF
Clinical study inpatient-reported outcomes after binocular implantation of aspheric intraocular lens of different negative spherical aberrations 被引量:3
15
作者 Ze-Quan Xu Xu-Hua Song +2 位作者 Wen-Zhe Li Yan Dou Qiang Wu 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2017年第7期771-774,共4页
Objective: To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens(IOLs), or the MCX11 ASP IOLs or the spherical IOLs(HQ-201HEP). Methods: Prospective nonrandomized controlled trial was ... Objective: To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens(IOLs), or the MCX11 ASP IOLs or the spherical IOLs(HQ-201HEP). Methods: Prospective nonrandomized controlled trial was used. A total of 105 patients(210 eyes) were divided into three groups according to the type of IOLs: ZA9003(35 patients, 70 eyes), MCX11 ASP(35 patients, 70 eyes) or HQ-201HEP(35 patients, 70 eyes). The main outcome was scores of Catquest nine-item short-form questionnaire. Additional outcome was best corrected visual acuities, spherical aberration(SA) and total higher-order aberrations(HOAs). Results: The global score was significantly lower in the spherical IOL group than the aspherical IOL group of-020 μm SA(P < 0.05) and the aspherical IOL group of-027 μm SA(P < 0.05), and no significant difference was found in the global score between the aspherical IOL group of-020 μm SA than the aspherical IOL group of-027 μm SA(P > 0.05). Significant differences were also found in question 2, question 5, question 6 and question 8 between the spherical IOLs and the aspherical IOLs. Conclusion: Implantation of an aspherical IOL could improve vision-related quality of life compared with a spherical IOL. However, there were no statistically significant differences in vision-related quality of life between aspheric IOLs with different negative spherical aberrations. 展开更多
关键词 Catquest nine-item short-form Patient-reported outcomes Vision-related quality aspheric intraocular lens Spherical aberration
下载PDF
Visual performance after implantation of two types of phakic foldable intraocular lenses for correction of high myopia 被引量:3
16
作者 Islam M.Rizk Abd-Almonem A.Al-hessy +1 位作者 Sherief E.El-Khouly Ashraf M.Sewelam 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第2期284-290,共7页
AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and ana... AIM: To compare Visian lens(model V4 c) and Artiflex lens regarding quality(contrast sensitivity) and quantity(efficacy, predictability, safety and stability) of vision in correcting high myopia with recording and analysis of complications. METHODS: The comparative prospective study included 39 eyes of 23 patients with high myopia, 19 eyes had Visian lens implantation(model V4 c) and 20 eyes had Artiflex lens implantation. The inclusion criteria were high myopia(higher than 6.0 D) and stable refraction(<0.5 D change over one year). Outcomes included assessment of safety and efficacy indices, predictability, stability, contrast sensitivity and analysis of complications at postoperative 1 d, 1 wk and 1, 3, 6 and 12 mo. Selection of the type of phakic intraocular lens for patients was based on surgeons' preferences, which was no specific selection criteria. RESULTS: After 12 mo of follow up, difference in uncorrected and corrected distant visual acuity(CDVA) between both groups was statistically insignificant(UDVA for VisianV4 c and Artiflex lens were 0.33±0.2 logMAR and 0.37±0.2 logMAR respectively, P=0.59, CDVA for VisianV4 c and Artiflex lens were 0.155±0.1 logMAR and 0.147± 0.1 logMAR respectively, P=0.87). The efficacy index was 1.25 for VisianV4 c lens and 0.8 for Artiflex lens, 78.9% of eyes were within one diopter spherical equivalent in Visian V4 c lens group compared to 70% in the Artiflex lens group. No eye lost lines of CVDA proving a good safety index for both lenses(safety index was 1.67 for VisianV4 c lens and 1.34 for Artiflex lens). Difference in contrast sensitivity between both groups was statistically insignificant(P=0.15, 0.88, 0.27, 0.32 and 0.82 at five spatial frequencies). CONCLUSION: Both Visian ICL V4 c and Artiflex lensesare safe and effective with stable and predictable refraction and they have comparable contrast sensitivity outcomes with no vision threatening complications. 展开更多
关键词 PHAKIC intraocular lenses IMPLANTABLE collamer Visian V4c LENS foldable Artiflex LENS
下载PDF
Study on the surface properties of surface modified silicone intraocular lenses 被引量:3
17
作者 Gui-Qin Wang Han-Qing Gu and Xiu-Jun Peng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第1期84-87,共4页
AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam c... AIM: To prepare a new-type soft intraocular lens (IOL) that silicone intraocular lenses (IOLs) were modified by surface modification technique to assess IOLs biocompatibility. METHODS: With the technique of ion beam combined with low temperature and low pressure plasma, the surface characteristics of the IOLs including physical and optical properties were determined by the instruments of IOLs resolution, UV/VIS scanning spectrophotometer, contact angle measurement system, electron spectroscopy for chemical analysis (ESCA) and scanning electron microscope (SEM). RESULTS: The color of titanium (Ti) modified IOLs was light yellow and that of titanium nitride (TiN) modified IOLs was light brown. The absorptive degree of ultraviolet rays and the hydrophilicity of the surfaces of modified IOLs were increased, and appeared suitable chemical compositions. The resolution of unmodified and modified IOLs reached normal standard. The surfaces of unmodified and Ti-modified IOLs appeared uniform. The surfaces of TIN-modified IOLs presented fine porcelain structure. CONCLUSION: The optical properties of all IOLs and the surface morphology of the modified IOLs were not affected by modification processes. The surface properties of the modified IOLs were improved. 展开更多
关键词 SILICONE intraocular lenses surface modification technique surface property BIOCOMPATIBILITY
下载PDF
Visual and optical performance of eyes with different corneal spherical aberration implanted with aspheric intraocular lens 被引量:8
18
作者 Xian-Hui Gong Qin-Xiang Zheng +4 位作者 Na Wang Ding Chen Juan Zhao Jin Li and Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第3期323-328,共6页
AIM: To compare the visual and optical performance of eyes with different corneal spherical aberration (SA) implanted with spherical aberration-free intraocular lens (IOLs). METHODS: Thirty-six patients with different... AIM: To compare the visual and optical performance of eyes with different corneal spherical aberration (SA) implanted with spherical aberration-free intraocular lens (IOLs). METHODS: Thirty-six patients with different corneal SA had phacoemulsification with implantation of spherical aberration-free IOLs. Patients were divided into 3 groups according to the value of preoperative corneal SA. Eyes with corneal SA <0.10 mu m were assigned to group A, those with 0.10 <= corneal SA <0.20 mu m to Group B, and those with 0.20 <= corneal SA <0.35 mu m to Group C. Best-corrected visual acuity (BCVA), contrast sensitivity, corneal SA, total ocular aberrations, and depth of focus were recorded 3 months postoperatively. Distance-corrected near and intermediate visual acuity was studied to measure depth of focus. RESULTS: BCVA and contrast sensitivity were similar between groups. There were no significant differences in distance-corrected near or intermediate visual acuity. Corneal SA was similar before and 3 months after surgery in the 3 groups. With a 5.0mm pupil diameter, root mean square values for total ocular higher-order aberrations (HOAs) were lower in groups A and B than in group C. Total ocular SA was lower in group A than in groups B and C. SA was also lower in group B than in group C. Coma and trefoil were similar between the groups. CONCLUSION: Implantation of spherical aberration-free IOLs in eyes with different corneal SA results in similar visual performance at BCVA, contrast sensitivity and depth of focus. 展开更多
关键词 spherical aberration-free intraocular lens sherical aberration contrast sensitivity CATARACT
下载PDF
F-heparin modified intraocular lenses in Rhesus monkeys 被引量:2
19
作者 Gui-Qin Wang Han-Qing Gu +2 位作者 Jia-Qin Yuan Hui-Min Sun and Yan-Shan Xu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2010年第2期141-144,共4页
AIMIn order to improve the biocompatibility of intraocular lenses (IOL), the polymethylmethacrylate (PMMA) IOL was modified with F-heparin.
关键词 intraocular lenses F-heparin surface modification BIOCOMPATIBILITY Rhesus monkeys
下载PDF
Potential of video games for the promotion of neuroadaptation to multifocal intraocular lenses: a narrative review 被引量:3
20
作者 Maria Begona Coco-Martin Pedro LValenzuela +3 位作者 Miguel JMaldonado-López Alejandro Santos-Lozano Ainhoa Molina-Martin David P Pinero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第11期1782-1787,共6页
Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they a... Multifocal intraocular lenses(IOLs) are currently usually implanted for the treatment of cataracts because they have been proved to be superior to monofocal IOLs with respect to spectacle independence. In turn, they are associated with a higher prevalence of dysphotopsia symptoms that is one of the most common causes of patient dissatisfaction. Neuroadaptation seems to play a major role in the optimal adaptation to multifocal IOLs. In this context, the development of strategies that facilitate the neuroadaptation process to multifocality might be an effective strategy to reduce patients' dissatisfaction. Video games have been proved to be effective for the improvement of visual acuity and for the promotion of neuroplasticity in elderly subjects and other populations with cortical-related visual impairment. This narrative review highlights the physiological potential of video games as a perceptual strategy to improve visual acuity and promote neuroplasticity in patients using multifocalIOLs, although research is still needed to confirm these benefits in this specific population, with only one comparative study to this date providing evidence of them. 展开更多
关键词 multifocal intraocular lens dysphotopsia photic phenomena HALOS video games NEUROADAPTATION NEUROPLASTICITY
下载PDF