Background: Acute dislocation of the thumb carpometacarpal (CMC) joint is a rare and challenging injury, and its treatment remains controversial. The purpose of the study was to evaluate the clinical outcome after sur...Background: Acute dislocation of the thumb carpometacarpal (CMC) joint is a rare and challenging injury, and its treatment remains controversial. The purpose of the study was to evaluate the clinical outcome after surgical repair of the dorsal capsulo-ligamentous complex. Materials and methods: Eight patients with a mean age of 39.8 years (range, 23 - 56 years) treated for the thumb CMC joint were treated in our hospital between 2008 and 2018. The ruptured dorsal capsulo-ligamentous complex was repaired using suture anchors in all patients, and the joint was immobilized with a Kirschner wire pinning and splint for 3 weeks. The clinical outcome was assessed by measuring the range of motion of the thumb CMC joint and the Japanese Society for Surgery of the Hand version of the Quick Disability of the Arm, Shoulder, and Hand (Q-DASH-JSSH) score. Results: The mean radial abduction of the thumb CMC joint was 66°, and the volar abduction was 63°. The mean Q-DASH-JSSH score was 4.8 (range, 0 - 15.6). There were no cases of infection, nerve disturbance, or osteoarthritis. Anatomical reduction was observed in seven patients at the final follow-up and in a rugby football player at 6 months of follow-up;however, subluxation of the thumb CMC joint at 12 months of follow-up due to reinjury was observed. Conclusion: Surgical repair of the dorsal capsulo-ligamentous complex with suture anchors is a reliable and simple treatment for acute unstable dislocation of the thumb CMC joint.展开更多
AIM To present the long-term results of complex knee injuries, treated early using the Ligament Augmentation and Reconstruction System(LARS) artificial ligament to reconstruct posterior cruciate ligament(PCL).METHODS ...AIM To present the long-term results of complex knee injuries, treated early using the Ligament Augmentation and Reconstruction System(LARS) artificial ligament to reconstruct posterior cruciate ligament(PCL).METHODS From September 1997 to June 2010, thirty-eight complex knee injuries were treated, where early arthroscopic PCL reconstructions were undergone, using the LARS(Surgical Implants and Devices, Arc-sur-Tille, France) artificial ligament. Exclusion criteria were: Late(> 4 wk) reconstruction, open technique, isolated PCL reconstruction, knee degenerative disease, combinedfracture or vascular injury and use of allograft or autograft for PCL reconstruction. Clinical and functional outcomes were assessed with IKDC Subjective Knee Form, KOS-ADLS questionnaire, Lysholm scale and SF-12 Health Survey. Posterior displacement(PD) was measured with the Telos Stress Device. RESULTS Seven patients were excluded; two because of coexisting knee osteoarthritis and the remaining five because of failure to attend the final follow-up. The sample consisted of 31 patients with mean age at the time of reconstruction 33.2 ± 12.5 years(range 17-61). The postoperative follow-up was on average 9.27 ± 4.27 years(range 5-18). The mean average IKDC and KOS scores were 79.32 ± 17.1 and 88.1 ± 12.47% respectively. Average PD was 3.61 ± 2.15 mm compared to 0.91 ± 1.17 mm in the uninjured knees(one with grade 1+ and two with grade 2 +). Dial test was found positive in one patient, whereas the quadriceps active drawer test was positive in three patients. None was tested positive on the reverse-pivot shift test. The range of motion(ROM) was normal in thirty knees, in comparison with the contralateral one. There was no extension deficit. Osteoarthritic changes were found in three knees(9.6%).CONCLUSION Early treatment of complex knee injuries, using LARS artificial ligament for PCL reconstruction sufficiently reduces posterior tibia displacement and provides satisfactory long-term functional outcomes.展开更多
BACKGROUND Surgical site infections following anterior cruciate ligament(ACL)reconstruction are an uncommon but potentially devastating complication.In this study,we present an unusual case of recurrent infection of t...BACKGROUND Surgical site infections following anterior cruciate ligament(ACL)reconstruction are an uncommon but potentially devastating complication.In this study,we present an unusual case of recurrent infection of the knee after an ACL reconstruction,and discuss the importance of accurate diagnosis and appropriate management,including the issue of graft preservation versus removal.CASE SUMMARY A 33-year-old gentleman underwent ACL reconstruction using a hamstring tendon autograft with suspensory Endobutton fixation to the distal femur and an interference screw fixation to the proximal tibia.Four years after ACL reconstruction,he developed an abscess over the proximal tibia and underwent incision and drainage.Remnant suture material was found at the base of the abscess and was removed.Five years later,he re-presented with a lateral distal thigh abscess that encroached the femoral tunnel.He underwent incision and drainage of the abscess which was later complicated by a chronic discharging sinus.Repeated magnetic resonance imaging revealed a fistulous communication between the lateral thigh wound extending toward the femoral tunnel with suggestion of osteomyelitis.Decision was made for a second surgery and the patient was counselled about the need for graft removal should there be intraarticular involvement.Knee arthroscopy revealed the graft to be intact with no evidence of intra-articular involvement.As such,the decision was made to retain the ACL graft.Re-debridement,excision of the sinus tract and removal of Endobutton was also performed in the same setting.Joint fluid cultures did not grow bacteria.However,tissue cultures from the femoral tunnel abscess grew Enterobacter cloacae complex,similar to what grew in tissue cultures from the tibial abscess five years earlier.In view of the recurrent and indolent nature of the infection,antibiotic therapy was escalated from Clindamycin to Ertapenem.He completed a six-week course of intravenous antibiotics and has been well for six months since surgery,with excellent knee function and no evidence of any further infection.CONCLUSION Prompt and accurate diagnosis of surgical site infection following ACL reconstruction,including the exclusion of intra-articular involvement,is important for timely and appropriate treatment.Arthroscopic debridement and removal of implant with graft preservation,together with a course of antibiotics,is a suitable treatment option for extra-articular knee infections following ACL reconstruction.展开更多
文摘Background: Acute dislocation of the thumb carpometacarpal (CMC) joint is a rare and challenging injury, and its treatment remains controversial. The purpose of the study was to evaluate the clinical outcome after surgical repair of the dorsal capsulo-ligamentous complex. Materials and methods: Eight patients with a mean age of 39.8 years (range, 23 - 56 years) treated for the thumb CMC joint were treated in our hospital between 2008 and 2018. The ruptured dorsal capsulo-ligamentous complex was repaired using suture anchors in all patients, and the joint was immobilized with a Kirschner wire pinning and splint for 3 weeks. The clinical outcome was assessed by measuring the range of motion of the thumb CMC joint and the Japanese Society for Surgery of the Hand version of the Quick Disability of the Arm, Shoulder, and Hand (Q-DASH-JSSH) score. Results: The mean radial abduction of the thumb CMC joint was 66°, and the volar abduction was 63°. The mean Q-DASH-JSSH score was 4.8 (range, 0 - 15.6). There were no cases of infection, nerve disturbance, or osteoarthritis. Anatomical reduction was observed in seven patients at the final follow-up and in a rugby football player at 6 months of follow-up;however, subluxation of the thumb CMC joint at 12 months of follow-up due to reinjury was observed. Conclusion: Surgical repair of the dorsal capsulo-ligamentous complex with suture anchors is a reliable and simple treatment for acute unstable dislocation of the thumb CMC joint.
文摘AIM To present the long-term results of complex knee injuries, treated early using the Ligament Augmentation and Reconstruction System(LARS) artificial ligament to reconstruct posterior cruciate ligament(PCL).METHODS From September 1997 to June 2010, thirty-eight complex knee injuries were treated, where early arthroscopic PCL reconstructions were undergone, using the LARS(Surgical Implants and Devices, Arc-sur-Tille, France) artificial ligament. Exclusion criteria were: Late(> 4 wk) reconstruction, open technique, isolated PCL reconstruction, knee degenerative disease, combinedfracture or vascular injury and use of allograft or autograft for PCL reconstruction. Clinical and functional outcomes were assessed with IKDC Subjective Knee Form, KOS-ADLS questionnaire, Lysholm scale and SF-12 Health Survey. Posterior displacement(PD) was measured with the Telos Stress Device. RESULTS Seven patients were excluded; two because of coexisting knee osteoarthritis and the remaining five because of failure to attend the final follow-up. The sample consisted of 31 patients with mean age at the time of reconstruction 33.2 ± 12.5 years(range 17-61). The postoperative follow-up was on average 9.27 ± 4.27 years(range 5-18). The mean average IKDC and KOS scores were 79.32 ± 17.1 and 88.1 ± 12.47% respectively. Average PD was 3.61 ± 2.15 mm compared to 0.91 ± 1.17 mm in the uninjured knees(one with grade 1+ and two with grade 2 +). Dial test was found positive in one patient, whereas the quadriceps active drawer test was positive in three patients. None was tested positive on the reverse-pivot shift test. The range of motion(ROM) was normal in thirty knees, in comparison with the contralateral one. There was no extension deficit. Osteoarthritic changes were found in three knees(9.6%).CONCLUSION Early treatment of complex knee injuries, using LARS artificial ligament for PCL reconstruction sufficiently reduces posterior tibia displacement and provides satisfactory long-term functional outcomes.
文摘BACKGROUND Surgical site infections following anterior cruciate ligament(ACL)reconstruction are an uncommon but potentially devastating complication.In this study,we present an unusual case of recurrent infection of the knee after an ACL reconstruction,and discuss the importance of accurate diagnosis and appropriate management,including the issue of graft preservation versus removal.CASE SUMMARY A 33-year-old gentleman underwent ACL reconstruction using a hamstring tendon autograft with suspensory Endobutton fixation to the distal femur and an interference screw fixation to the proximal tibia.Four years after ACL reconstruction,he developed an abscess over the proximal tibia and underwent incision and drainage.Remnant suture material was found at the base of the abscess and was removed.Five years later,he re-presented with a lateral distal thigh abscess that encroached the femoral tunnel.He underwent incision and drainage of the abscess which was later complicated by a chronic discharging sinus.Repeated magnetic resonance imaging revealed a fistulous communication between the lateral thigh wound extending toward the femoral tunnel with suggestion of osteomyelitis.Decision was made for a second surgery and the patient was counselled about the need for graft removal should there be intraarticular involvement.Knee arthroscopy revealed the graft to be intact with no evidence of intra-articular involvement.As such,the decision was made to retain the ACL graft.Re-debridement,excision of the sinus tract and removal of Endobutton was also performed in the same setting.Joint fluid cultures did not grow bacteria.However,tissue cultures from the femoral tunnel abscess grew Enterobacter cloacae complex,similar to what grew in tissue cultures from the tibial abscess five years earlier.In view of the recurrent and indolent nature of the infection,antibiotic therapy was escalated from Clindamycin to Ertapenem.He completed a six-week course of intravenous antibiotics and has been well for six months since surgery,with excellent knee function and no evidence of any further infection.CONCLUSION Prompt and accurate diagnosis of surgical site infection following ACL reconstruction,including the exclusion of intra-articular involvement,is important for timely and appropriate treatment.Arthroscopic debridement and removal of implant with graft preservation,together with a course of antibiotics,is a suitable treatment option for extra-articular knee infections following ACL reconstruction.
文摘目的:探讨颈椎过伸性损伤中椎间盘韧带复合体(disco-ligamentous complex,DLC)损伤的影像特点及其临床意义。方法:对2007年7月~2011年11月在我院手术治疗且病历资料完整的50例颈椎过伸性损伤患者的临床资料进行回顾性分析。均有颈脊髓损伤,脊髓功能Frankel分级:A级4例,B级8例,C级11例,D级27例。按术前患者X线片、CT及MRI显示的脊髓受压原因,将患者分为3组:单纯单个椎间盘突出(herniated nucleus pulposus,HNP)组14例,合并颈椎病(cervical spondylosis,CS)组26例,合并后纵韧带骨化(ossification of the posterior longitudinal ligament,OPLL)组10例,分析各组患者DLC损伤的影像特点及手术方式的异同。结果:50例患者均有颈椎前纵韧带和椎间盘的损伤,其中8例伴后纵韧带损伤,5例伴关节突骨折,3例伴棘突间韧带损伤。50例患者均有颈脊髓受压与损伤,均行颈椎减压、融合与内固定术,手术节段包括DLC损伤节段与脊髓受压节段。HNP组的DLC损伤均为1个节段,DLC损伤节段与脊髓受压节段一致率为92.85%,均采用前路手术。合并CS组,1个节段DLC损伤16例,2个节段6例,3个节段4例,多节段损伤时均为相邻节段,DLC损伤节段与脊髓受压节段一致率为84.61%,行前路手术23例、后路手术3例。合并OPLL组,1个节段DLC损伤4例,2个节段6例,DLC损伤节段与脊髓受压节段一致率为60%,行前路手术1例、后路手术5例、前后联合入路手术4例。术后3个月时脊髓功能Frankel分级,28例提高1级,22例无变化。结论:颈椎过伸性损伤患者的DLC损伤特点与术前的颈椎病理状态有关,DLC损伤节段与脊髓受压节段不完全一致;制定手术方案时,颈椎稳定性重建应包括DLC损伤节段,同时兼顾脊髓受压节段的减压。