期刊文献+
共找到49篇文章
< 1 2 3 >
每页显示 20 50 100
A Reflectron Time-of-Flight Mass Spectrometer with a Nano-Electrospray Ionization Source for Study of Metal Cluster Compounds
1
作者 吴小虎 谢华 +3 位作者 刘志凌 苏海峰 林水潮 唐紫超 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2016年第4期401-406,I0001,共7页
An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-o... An experiment facility has been set up for the study of metal cluster compounds in our laboratory, which consists of a nano-electrospray ionization source, an ion transmission and focus system, and a reflectron time-of-fight mass spectrometer. Taking advantage of the nano-electrospray ionization source, polyvalent ions are usually produced in the "ionization" process and the obtained mass resolution of the equipment is over 8000. The molecular ion peaks of metal cluster compounds [Au20(PPhpy2)10Cl2](SbF6)4, where PPhpy2=bis(2- pyridyl)phenylphosphine, and [AuaAg2(C)L6](BF4)4, where L=2-(diphenylphosphino)-5- methylpyridine, are distinguished in the respective mass spectrum, accompanied by some fragment ion peaks. In addition, the mass-to-charge ratios of the parent ions are determi- nated. Preliminary results suggest that the device is a powerful tool for the study of metal cluster compounds. It turns out that the information obtained by the instrumentation serves as an essential supplement to single crystal X-ray diffraction for structure characterization of metal cluster compounds. 展开更多
关键词 Nano-electrospray ionization source Ion transmission and focus system Reflectron time-of-flight mass spectrometer Metal cluster compounds Single crystal X-ray diffraction
下载PDF
Modification of Reflectron Time-of-Flight Mass Spectrometer for Photodissociation of Mass-Selected Cluster lons 被引量:3
2
作者 Yu-chao Zhao Zeng-guang Zhang +2 位作者 Jin-yun Yuan Hong-guang Xu Wei-jun Zheng 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2009年第6期655-662,J0002,共9页
We introduce a modification of reflectron time-of-flight mass spectrometer for laser photodissociation of mass-selected ions. In our apparatus, the ions of interests were selected by a mass gate near the first space f... We introduce a modification of reflectron time-of-flight mass spectrometer for laser photodissociation of mass-selected ions. In our apparatus, the ions of interests were selected by a mass gate near the first space focus point and decelerated right after the mass gate, were then crossed by a laser beam for dissociation. The daughter ions and surviving parent ions were re-accelerated and analyzed by the reflectron time-of-flight mass spectrometer. Compared to the designs reported by other research groups, our selection-deceleration-dissociation-reacceleration approach has better daughter-parent-ions-separation, easier laser timing, and better overlapping between the ion beam and laser beam. We also conducted detailed cal- culations on the parent ion and daughter ion flight times, and provided a simplified formula for the calibration of daughter ion mass. 展开更多
关键词 Reflectron time-of-flight mass spectrometer PHOTODISSOCIATION mass-selection CLUSTER
下载PDF
Design and simulation of a liquid-microjet time-of-flight mass spectrometer with a femtosecond laser ionization source
3
作者 Jinyou Long Jie Wei +2 位作者 Yaping Wang Song Zhang Bing Zhang 《Chinese Journal of Chemical Physics》 2024年第6期797-806,I0042,共11页
A liquid-microjet(LJ)linear time-of-flight(TOF)mass spectrometer,coupled with a femtosecond laser ionization source,has been designed for direct measurements of mass spectra of liquid aqueous solutions.Two main featur... A liquid-microjet(LJ)linear time-of-flight(TOF)mass spectrometer,coupled with a femtosecond laser ionization source,has been designed for direct measurements of mass spectra of liquid aqueous solutions.Two main features of our designed spectrometer involve the coupling of a liquid microjet nozzle to a conventional ion optics and the application of femtosecond pulses for mass spectral ionization.The detailed design,construction,and simulation of this new spectrometer are presented.More importantly,we combined the experimental tests with the simulated electric fields and ion trajectories to investigate the performance of the designed spectrometer,especially the kind of disturbances of the nozzle electric field on the conventional ion optics.In our current design,the optimal E/R(E:extractor,R:repeller)electrode voltage ratio was found to be∼0.71 when the voltages on the R,E and G(ground)electrodes were set to be 1500,1060 and 0 V,respectively,whilst the voltage on the N nozzle electrode was required to be around 1250 V.The capability of the designed spectrometer has been demonstrated by recording the simulated mass spectra of the water,benzene and cytidine with their mass/charge ratios of 18,76 and 243,respectively.This work shall be helpful for the development of new all-liquid-phase mass spectral technology to be employed in the diagnosis of diseases by the mass analysis of human body fluids. 展开更多
关键词 Liquid microjet time-of-flight mass spectrometer Aqueous solution
下载PDF
Mass Spectrometric Studies on Metal-hexafluorobenzene Anionic Complexes(M=Ag, Au, Pd, Pt, Pb and Bi)
4
作者 SUN Zhang SUN Shu-tao +3 位作者 LIU Hong-tao ZHU Qi-he GAO Zhen TANG Zi-chao 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2009年第2期228-233,共6页
The anionic products from the reactions between metal(M=Ag, Au, Pd, Pt, Pb and Bi) vapour produced by laser ablation and hexafluorobenzene seeded in carrier gas(Ar) were studied by means of a homemade reflectron t... The anionic products from the reactions between metal(M=Ag, Au, Pd, Pt, Pb and Bi) vapour produced by laser ablation and hexafluorobenzene seeded in carrier gas(Ar) were studied by means of a homemade reflectron time-of-flight mass spectrometry(RTOF-MS). Experimental results show that the dominant products were [MmC6F6]^- complexes for the reactions ofAg, Au, Pd and Pt with C6F6, while the dominant products were [MmC6F5]^- complexes for the reactions of Pb and Bi with C6F6. The formation mechanisms of the products, including the adsorption of metal cluster anions on hexafluorobenzene and the C--F cleavage induced by metal cluster anions, were discussed. 展开更多
关键词 time-of-flight mass spectrometer Metal cluster Anionic complex Reaction mechanism
下载PDF
A collinear tandem time-of-flight mass spectrometer for infrared photodissociation spectroscopy of mass-selected ions 被引量:2
5
作者 WANG GuanJun CHI ChaoXian +2 位作者 XING XiaoPeng DING ChuanFan ZHOU MingFei 《Science China Chemistry》 SCIE EI CAS 2014年第1期172-177,共6页
An apparatus based on collinear tandem time-of-flight mass spectrometer has been designed for the measurement of infrared photodissociation spectroscopy of mass-selected ions in the gas phase.The ions from a pulsed la... An apparatus based on collinear tandem time-of-flight mass spectrometer has been designed for the measurement of infrared photodissociation spectroscopy of mass-selected ions in the gas phase.The ions from a pulsed laser vaporization supersonic ion source are skimmed and mass separated by a Wiley-McLaren time-of-flight mass spectrometer.The ion of interest is mass selected,decelerated and dissociated by a tunable IR laser.The fragment and parent ions are reaccelerated and mass analyzed by the second time-of-flight mass spectrometer.A simple new assembly integrated with mass gate,deceleration and reacceleration ion optics was designed,which allows us to measure the infrared spectra of mass selected ions with high sensitivity and easy timing synchronization. 展开更多
关键词 infrared PHOTODISSOCIATION spectroscopy time-of-flight mass spectrometer mass selection ion SPECTROSCOPY
原文传递
Radiofrequency field enhanced chemical ionization with vacuum ultraviolet lamp for miniature time-of-flight mass spectrometer 被引量:1
6
作者 Lijuan Zhou Jichun Jiang +5 位作者 Kun Zhao Jinxu Li Chenxin Wu Haiyang Li Di Tian Keyong Hou 《Chinese Chemical Letters》 SCIE CAS CSCD 2018年第5期707-710,共4页
It is difficult to rapidly and on-line detect trace volatile organic compounds for miniature massspectrometry due to its limited sampling volume at slow pumping speed. In this paper, we developed anew radiofrequency f... It is difficult to rapidly and on-line detect trace volatile organic compounds for miniature massspectrometry due to its limited sampling volume at slow pumping speed. In this paper, we developed anew radiofrequency field enhanced chemical ionization source (RF-ECI) with vacuum ultraviolet (VUV)lamp by coupling radiofrequency electric field and direct-current field together. The experiment resultsshowed that the sensitivity of benzene, toluene, hydrogen sulfide and other compounds increased by 2-3orders of magnitude under the introduction of RF-ECI comparing to traditional single photon ionization(SPI). At the same time, the reagent ion of O2+ realized the charge transfer reaction chemical ionization,and the RF-ECI effectively expanded the detection range of the VUV lamp based SPI. The VUV lamp hasinherent advantages in the on-site analytical instrument for its small size and low power consumption,and the VUV lamp based RF-ECI miniature time-of-flight mass spectrometer (TOFMS) has a limit-of-detection for H2S as low as 0.0571 mg/m3, and it is expected to be used widely in the field of on-site rapidanalvsis. 展开更多
关键词 Radio-frequency field enhanced chemical ionization Vacuum ultraviolet lamp Single photon ionization Miniature time-of-flight mass spectrometer On site analysis
原文传递
Improved identification of glycerophospholipids using a linear ion trap mass spectrometer(LTQ) with Pulsed Q Collision Induced Dissociation(PQD)
7
作者 Tanxi Cai, Jing Li, Peng Xue, Zhengsheng Xie, Ziyou Cui, Junjie Hou, Xiulan Chen, Peng Wu, Pingsheng Liu, Fuquan Yang Proteomic Platform & National Laboratory of Biomacromolecules, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China, 100101 《生物物理学报》 CAS CSCD 北大核心 2009年第S1期191-191,共1页
Phospholipids are the major building blocks of the biological membranes. Additionally, phospholipids modulate membrane trafficking and metabolites derived from their
关键词 PQD with Pulsed Q Collision Induced Dissociation Improved identification of glycerophospholipids using a linear ion trap mass spectrometer
原文传递
固相萃取-超高效液相色谱-三重四极杆/线性离子阱质谱法检测水中大环内酯类抗生素
8
作者 范素素 蔡萌 +2 位作者 方烨渟 王丽婕 石健 《分析科学学报》 CAS CSCD 北大核心 2024年第3期293-299,共7页
采用固相萃取-超高效液相色谱-三重四极杆线性离子阱质谱技术(SPE-UPLC-QTRAP MS)建立了环境水样中阿奇霉素、林可霉素、克林霉素、红霉素及替米考星5种大环内酯类抗生素的检测方法。调节水样pH为10后经HLB固相萃取柱净化、富集,然后用K... 采用固相萃取-超高效液相色谱-三重四极杆线性离子阱质谱技术(SPE-UPLC-QTRAP MS)建立了环境水样中阿奇霉素、林可霉素、克林霉素、红霉素及替米考星5种大环内酯类抗生素的检测方法。调节水样pH为10后经HLB固相萃取柱净化、富集,然后用Kinetex F5色谱柱进行分离,用0.1%甲酸水溶液和0.1%甲酸乙腈溶液进行洗脱,采用电喷雾正离子源(ESI+),多反应监测(MRM)-信息依赖采集(IDA)-增强子离子(EPI)扫描模式对样品进行检测,用多反应监测(MRM)进行定量,增强子离子(EPI)谱图库辅助定性。结果表明:5种大环内酯类抗生素线性关系良好,相关系数均大于0.9992;检出限为0.01~0.30μg·L^(-1),定量限为0.10~0.50μg·L^(-1);3种不同浓度的水样加标回收率为71.60%~111.05%,相对标准偏差均在10%以内,EPI谱库比对纯度值均大于90%。该方法将传统的MRM扫描模式结合EPI谱图库检索,实现了同时定性和定量分析,对未知物准确定性定量检测提供了重要参考。 展开更多
关键词 大环内酯类抗生素 固相萃取 线性离子阱 液质联用 残留检测
下载PDF
基于快速高分辨液相色谱串联质谱技术的代谢组学尿液分析方法的建立 被引量:21
9
作者 陈艳华 张瑞萍 +3 位作者 宋咏梅 董立佳 詹启敏 再帕尔.阿不力孜 《分析化学》 SCIE EI CAS CSCD 北大核心 2011年第2期173-177,共5页
采用快速高分辨液相色谱(RRLC)分离系统与QTRAP型及QTOF型MS/MS仪联用技术,通过考察尿液样本前处理方法,优化液相色谱条件和质谱检测参数,建立了用于尿液中代谢物分析的RRLC-MS方法。采用本方法对尿液浓度下的20种代表性代谢物进行了检... 采用快速高分辨液相色谱(RRLC)分离系统与QTRAP型及QTOF型MS/MS仪联用技术,通过考察尿液样本前处理方法,优化液相色谱条件和质谱检测参数,建立了用于尿液中代谢物分析的RRLC-MS方法。采用本方法对尿液浓度下的20种代表性代谢物进行了检测,考察了方法的灵敏度和精密度,证明本方法适用于尿液代谢组学的研究。对穿插在检测序列中的生物质控样本的监测结果表明,本方法的可重复性及获得的数据的可靠性良好。本方法已成功地应用于乳腺癌和宫颈癌的尿液代谢组学研究以及可能生物标志物的检测。 展开更多
关键词 代谢组学 快速高分辨液相色谱串联质谱技术 四极杆-线性离子阱串联质谱仪 四级杆-飞行时间串联质谱仪
下载PDF
气相色谱矩形离子阱质谱联用仪的设计与性能 被引量:7
10
作者 黄泽建 白岗 +3 位作者 江游 张小华 熊行创 方向 《分析化学》 SCIE EI CAS CSCD 北大核心 2008年第3期413-418,共6页
气相色谱离子阱质谱联用仪(GC-ITMS)广泛地应用于药物分析、环境分析、农药检测和食品分析、有机化学品分析、毒品分析以及医学和生物分析等领域。离子阱质谱作为色谱的检测器,决定了色质联用仪的分析性能,包括检出限、分辨率。离子阱... 气相色谱离子阱质谱联用仪(GC-ITMS)广泛地应用于药物分析、环境分析、农药检测和食品分析、有机化学品分析、毒品分析以及医学和生物分析等领域。离子阱质谱作为色谱的检测器,决定了色质联用仪的分析性能,包括检出限、分辨率。离子阱质量分析器从传统的双曲型3D离子阱发展到2D线性离子阱,质量歧视效应得到了极大的改善,灵敏度得到了提高。矩形离子阱作为线性离子阱,结构简单,加工和装配容易,因此应用到GCMS系统中将具有非常大的优势。介绍了矩形离子阱质谱仪的设计方案、仪器整机的性能测试、质量分辨和质量歧视效应分析,与Agilent6890组成GCMS联用仪,对实际样品进行了分析。 展开更多
关键词 气相色普 质培联用仪 离子阱质谱 线性离子阱 矩彤离子阱 质量歧视效应 串联质谱
下载PDF
基于LTQ-Orbitrap液相色谱-质谱联用技术的乳源乳清蛋白组分的差异性研究 被引量:5
11
作者 徐明芳 戴金凤 +4 位作者 向明霞 成希飞 曾晓琮 万丛庆 周卫军 《分析化学》 SCIE EI CAS CSCD 北大核心 2014年第4期501-506,共6页
利用LTQ Orbitrap XL组合型傅立叶变换高分辨质谱系统分析了乳源蛋白主要组分肽指纹图谱。对南方水牛乳与不同来源的乳清蛋白的氨基酸序列研究结果表明,乳清蛋白经酶解后主要为α-乳白蛋白(α-La)和β-乳球蛋白(β-Lg)组分,乳清蛋白肽... 利用LTQ Orbitrap XL组合型傅立叶变换高分辨质谱系统分析了乳源蛋白主要组分肽指纹图谱。对南方水牛乳与不同来源的乳清蛋白的氨基酸序列研究结果表明,乳清蛋白经酶解后主要为α-乳白蛋白(α-La)和β-乳球蛋白(β-Lg)组分,乳清蛋白肽质指纹谱的分析显示水牛乳与荷斯坦奶乳清蛋白α-La氨基酸发生变异的比率明显少于山羊奶乳清蛋白α-La,说明荷斯坦奶α-La和水牛乳α-La的差异更小,同源性更强;而水牛乳β-Lg与荷斯坦乳β-Lg氨基酸发生变异的部位比率要多于山羊奶,水牛乳β-Lg与山羊奶同源性更强;乳源酪蛋白酶解后的肽段主要组分为αs1-CN,β-CN,κ-N,通过对水牛乳酪蛋白的氨基酸序列的差异性分析,不同品种的乳源酪蛋白的氨基酸序列明显存在差异。与乳清蛋白相比,奶牛品种差异导致乳蛋白发生氨基酸差异现象更显著,酪蛋白的氨基酸序列对比表明,水牛奶酪蛋白与山羊奶酪蛋白比与乳牛酪蛋白的差异更大。 展开更多
关键词 LTQ Orbitrap质谱 乳源蛋白 酪蛋白 乳清蛋白 肽质指纹谱 差异性
下载PDF
高效液相色谱和高效液相色谱-离子阱质谱测定花生、玉米和大米中黄曲霉毒素方法比较 被引量:24
12
作者 范素芳 李培武 +3 位作者 王秀嫔 丁小霞 张文 张奇 《食品科学》 EI CAS CSCD 北大核心 2011年第12期254-258,共5页
比较花生、玉米和大米中黄曲霉毒素(AFT)测定的两种分析方法。样品经70%甲醇溶液(含NaCl 4g/100mL)提取,自制免疫亲和柱净化。洗脱液一分为二,一份经正己烷、三氟乙酸衍生后用配有荧光检测器的液相色谱检测;另一份无需衍生用液相色谱-... 比较花生、玉米和大米中黄曲霉毒素(AFT)测定的两种分析方法。样品经70%甲醇溶液(含NaCl 4g/100mL)提取,自制免疫亲和柱净化。洗脱液一分为二,一份经正己烷、三氟乙酸衍生后用配有荧光检测器的液相色谱检测;另一份无需衍生用液相色谱-串联离子阱质谱检测。液相色谱测定的AFB1、AFB2、AFG1和AFG2的检出限(RSN=3)分别为0.5~1.5μg/kg,相关系数在0.9979~0.9999,加标回收率50.29%~126.54%;液相色谱-串联质谱测定的AFB1、AFB2、AFG1和AFG2的检出限分别为0.1~0.2μg/kg;相关系数在0.9993~0.9998,加标回收率50.38%~121.27%。结果表明液相色谱-离子阱质谱法无论在选择性还是在灵敏度上都优于高效液相色谱。 展开更多
关键词 黄曲霉毒素 高效液相色谱(HPLC) 高效液相色谱-离子阱质谱(HPLC-iontrap-MS) 方法比较
下载PDF
超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱鉴别纺织品中禁用芳香胺及其异构体 被引量:14
13
作者 叶曦雯 彭燕 +4 位作者 牛增元 高永刚 罗忻 邹立 周明辉 《色谱》 CAS CSCD 北大核心 2014年第9期1005-1012,共8页
针对目前纺织品中禁用偶氮染料检测中的假阳性问题,建立了一套应用超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱(UPLC-LTQ/Orbitrap)同时筛选24种禁用芳香胺及其常见的14种异构体的方法。样品经连二亚硫酸钠还原,叔丁基甲醚提取... 针对目前纺织品中禁用偶氮染料检测中的假阳性问题,建立了一套应用超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱(UPLC-LTQ/Orbitrap)同时筛选24种禁用芳香胺及其常见的14种异构体的方法。样品经连二亚硫酸钠还原,叔丁基甲醚提取后,以水/甲醇(9/1,v/v)稀释定容,用ZORBAX SB-C18色谱柱(150 mm×2.1mm,5μm)分离,以0.1%甲酸水溶液和甲醇为流动相,电喷雾正离子(ESI+)模式电离。以准分子离子峰的精确质量数和保留时间定性,以提取的色谱图峰面积定量。38种芳香胺的线性相关系数大于0.99,方法检出限为0.5-5μg/kg。该方法可通过一次实验同时对24种禁用芳香胺及其常见的14种异构体准确定性定量,大大缩短检测周期,实际样品检测也进一步验证了其灵敏性和准确性。 展开更多
关键词 超高效液相色谱 线性离子阱 静电场轨道阱质谱 高分辨质谱 禁用偶氮染料 同分异构体 纺织品
下载PDF
超高效液相色谱-高分辨质谱法快速筛查确证调味品中的19种非食用物质 被引量:7
14
作者 徐琴 吕宁 +4 位作者 郝鹏飞 孟慧琴 徐丽 修晓丽 罗忻 《食品安全质量检测学报》 CAS 2017年第11期4174-4183,共10页
目的建立超高效液相色谱-高分辨质谱法检测调味品中19种非食用物质的分析方法。方法样品经乙酸乙酯-环己烷提取,采用凝胶渗透色谱(gel permeation chromatography,GPC)净化与在线定量浓缩,然后经C_(18)色谱柱分离,乙腈和5 mmol/L乙酸铵(... 目的建立超高效液相色谱-高分辨质谱法检测调味品中19种非食用物质的分析方法。方法样品经乙酸乙酯-环己烷提取,采用凝胶渗透色谱(gel permeation chromatography,GPC)净化与在线定量浓缩,然后经C_(18)色谱柱分离,乙腈和5 mmol/L乙酸铵(含0.1%甲酸)溶液梯度洗脱后经超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱(ultra performance liquid chromatography-linear ion trap-orbitrap high resolution mass spectrometry,UPLC-LTQ-orbitrap MS)测定。结果 19种目标物在15 min内实现良好分离,线性相关系数均≥0.996,定量限(limit of quantitation,LOQ)为5~15μg/kg,加标回收率在61.9%~105.8%之间,相对标准偏差(relative standard deviation,RSD)为2.3%~12.9%。结论本研究建立的方法准确、简单,可适用于调味品中19种非食用物质的定性定量及确证分析。 展开更多
关键词 线性离子阱静电场轨道阱 高分辨质谱 凝胶渗透色谱 调味品 非食用物质
下载PDF
测试氦质谱检漏仪线性的一种新方法 被引量:3
15
作者 王勇 孙立臣 +1 位作者 闫荣鑫 孙立志 《中国空间科学技术》 EI CSCD 北大核心 2011年第2期39-42,共4页
根据氦质谱检漏仪中机械泵的抽速在某真空范围内恒定的特性,首次提出了一种考察检漏仪线性能力的新方法,并通过试验验证了该方法的合理性。该方法通过调整检漏仪的入口压力来改变进入检漏仪的气体流量,对于氦气浓度恒定的混合气体则可... 根据氦质谱检漏仪中机械泵的抽速在某真空范围内恒定的特性,首次提出了一种考察检漏仪线性能力的新方法,并通过试验验证了该方法的合理性。该方法通过调整检漏仪的入口压力来改变进入检漏仪的气体流量,对于氦气浓度恒定的混合气体则可以改变进入检漏仪中的氦气流量,从而改变检漏仪的输出读数;通过分析检漏仪的入口压力与最终输出读数间的关系考察检漏仪的线性能力。结果表明:该方法简便、成本低廉,测试范围涵盖了工程常用的漏率范围。 展开更多
关键词 逆流 氦质谱仪 检漏 线性 航天器
下载PDF
一种光电离离子阱质谱仪技术研究 被引量:6
16
作者 黄泽建 唐晓强 方向 《质谱学报》 EI CAS CSCD 2009年第2期65-69,共5页
介绍了自行研制的紫外光电离离子阱质谱仪的原理和性能。真空紫外灯产生能量为10.6 eV,光子照射到离子阱内部,挥发到离子阱内的样品气体被光子电离,随即被离子阱捕获。离子阱既作为电离室,同时又作为质量分析器,并且不断将样品离子富集... 介绍了自行研制的紫外光电离离子阱质谱仪的原理和性能。真空紫外灯产生能量为10.6 eV,光子照射到离子阱内部,挥发到离子阱内的样品气体被光子电离,随即被离子阱捕获。离子阱既作为电离室,同时又作为质量分析器,并且不断将样品离子富集,从而大大提高了质谱仪的检测灵敏度。样品气体分子在光子的照射作用下只产生单电荷母离子,不产生碎片离子,以该电离方式获得的质谱图非常简单,因此气体样品不需分离即可进行检测。紫外光电离和离子阱质谱仪的结合将特别适合挥发性有机污染物和有毒气体的现场快速检测,具有广泛的市场前景。 展开更多
关键词 光电离 离子阱质谱 线性离子阱 矩形离子阱
下载PDF
蛋白质组学研究中傅立叶变换离子回旋共振质谱数据采集方法的比较 被引量:2
17
作者 曾家伟 贾伟 +1 位作者 应万涛 钱小红 《分析化学》 SCIE EI CAS CSCD 北大核心 2010年第9期1238-1242,共5页
探讨了线性离子阱-傅立叶变换离子回旋共振质谱(LTQ-FT)的数据采集模式对蛋白质组鉴定结果的影响,比较和分析了针对不同复杂程度样本的最佳采集模式。对于α-乳清蛋白4种标准蛋白质酶切肽段混合物的简单体系,在傅立叶变换离子回旋共振... 探讨了线性离子阱-傅立叶变换离子回旋共振质谱(LTQ-FT)的数据采集模式对蛋白质组鉴定结果的影响,比较和分析了针对不同复杂程度样本的最佳采集模式。对于α-乳清蛋白4种标准蛋白质酶切肽段混合物的简单体系,在傅立叶变换离子回旋共振腔中选3个最强母离子进行选择离子监测扫描后,再实施二级碎裂的方法(SIM3)得到的肽段覆盖率,分别是直接选10个最强母离子进行二级碎裂(FT10)方法得到的肽段覆盖率的1.5~1.9倍。另外,对酵母蛋白酶切肽段混合物的复杂体系鉴定时,只采集双电荷和三电荷母离子进行二级扫描的方法(FT10_23)比单电荷、双电荷和三电荷都采集的方法(FT10_123)得到的图谱鉴定成功率提高64.1%。实验还对不同数据采集模式下图谱的特点进行了考察。本研究表明,针对不同复杂程度的样本,应采取不同的质谱数据采集方法。 展开更多
关键词 蛋白质组学 质谱采集模式 线性离子阱-傅立叶变换离子回旋共振质谱
下载PDF
超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱快速测定大米中15种营养成分 被引量:7
18
作者 朱丽 谭微 +3 位作者 彭祖茂 邓梦雅 张协光 杨国武 《色谱》 CAS CSCD 北大核心 2017年第9期949-956,共8页
建立了超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱(UHPLC-LTQ/Orbitrap HRMS)同时快速检测大米中15种营养成分(8种维生素E、6种γ-谷维素及β-胡萝卜素)的方法。样品经过含0.05%(v/v)2,6-二叔丁基-4-甲基苯酚(BHT)的甲醇溶液超... 建立了超高效液相色谱-线性离子阱/静电场轨道阱高分辨质谱(UHPLC-LTQ/Orbitrap HRMS)同时快速检测大米中15种营养成分(8种维生素E、6种γ-谷维素及β-胡萝卜素)的方法。样品经过含0.05%(v/v)2,6-二叔丁基-4-甲基苯酚(BHT)的甲醇溶液超声提取处理后,用Poroshell 120 PFP色谱柱(150 mm×3.0 mm,2.7μm)分离,以0.1%(v/v)甲酸水溶液和含0.1%(v/v)甲酸的甲醇溶液为流动相,在正离子模式下通过UHPLC-LTQ/Orbitrap HRMS进行全扫描分析。15种营养成分可在13 min内获得满意的分离效果。15种营养成分在各自的线性范围内线性关系良好,相关系数(r)≥0.995 0,15种营养成分的检出限(S/N=3)为0.2~1.8μg/L,定量限(S/N=10)为0.7~6.1μg/L,在3个添加水平下的平均加标回收率分别为73.2%~101.5%,相对标准偏差(RSD)为1.1%~5.0%(n=3)。该法准确,高效,可靠,适用于大米中多种营养成分的同时测定。 展开更多
关键词 超高效液相色谱 线性离子阱/静电场轨道阱高分辨质谱 营养成分 维生素E γ-谷维素 6-胡萝卜素 大米
下载PDF
四极质谱计的计量特性研究 被引量:4
19
作者 卢耀文 冯焱 李得天 《真空与低温》 2007年第4期222-228,239,共8页
四极质谱计是一种分压力测量仪器,可广泛应用于残余气体分析和真空流量的测量,其计量特性需要深入研究。用N2、Ar、He3种气体作为实验气体,对4台应用范围较广、具有一定代表性的商用四极质谱计的线性、长期稳定性、短期稳定性、离子源... 四极质谱计是一种分压力测量仪器,可广泛应用于残余气体分析和真空流量的测量,其计量特性需要深入研究。用N2、Ar、He3种气体作为实验气体,对4台应用范围较广、具有一定代表性的商用四极质谱计的线性、长期稳定性、短期稳定性、离子源参量及使用历史对灵敏度的影响等性能进行了实验研究,并分析了它们各自的计量特性与特点,其结论对四极质谱计的应用具有重要的参考价值。 展开更多
关键词 四极质谱计 线性 稳定性 计量特性
下载PDF
四极质谱计在高压力下的测量方法 被引量:2
20
作者 卢耀文 张涤新 +5 位作者 冯焱 郭美如 成永军 赵光平 赵澜 李莉 《真空与低温》 2007年第2期85-89,115,共6页
四极质谱计是一种分压力测量仪器,其线性上限一般为10-3Pa。通过对影响四极质谱计测量上限的因素进行分析,得到高压力下的分压力计算方法,并通过实验验证了该方法的可行性,得出的结论对高压力下四极质谱计的应用具有一定的参考价值。
关键词 四极质谱计 分压力 灵敏度 线性
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部