期刊文献+
共找到13,918篇文章
< 1 2 250 >
每页显示 20 50 100
Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
1
作者 Pan Lijing Chen Weiwei Yuan Minjia 《China Detergent & Cosmetics》 CAS 2023年第4期30-36,共7页
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte... An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics. 展开更多
关键词 ultra performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS) OLEUROPEIN COSMETICS
下载PDF
Determination of Voriconazole in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry: Application in Therapeutic Drug Monitoring
2
作者 Waleed Alhussaini Ezzeldeen Ghanem +4 位作者 Magd Alsahly Amani Kurdi Eman Alharbi Imadul Islam Majed Aljeraisy 《American Journal of Analytical Chemistry》 2023年第9期378-389,共12页
A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with flucona... A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM. 展开更多
关键词 VORICONAZOLE Human Plasma liquid chromatography tandem mass spectrometry Therapeutic Drug Monitoring
下载PDF
Rapid analysis of fifteen sulfonamide residues in pork and fish samples by automated on-line solid phase extraction coupled to liquid chromatography–tandem mass spectrometry 被引量:6
3
作者 Junmei Ma Sufang Fan +3 位作者 Lei Sun Liangna He Yan Zhang Qiang Li 《Food Science and Human Wellness》 SCIE 2020年第4期363-369,共7页
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples... The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish. 展开更多
关键词 liquid chromatographytandem mass spectrometry On-line solid phase extraction SULFONAMIDES Internal standard quantification
下载PDF
Determination of urine catecholamines and metanephrines by reversed-phase liquid chromatography-tandem mass spectrometry 被引量:6
4
作者 CHEUK Man-Yung LO Yun-Chuen POON Wing-Tat 《色谱》 CAS CSCD 北大核心 2017年第10期1042-1047,共6页
The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tande... The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for determining catecholamines and metanephrines in urine to replace an existing liquid chromatographic method using electrochemical detection.Urine samples were prepared using Oasis weak-cation-exchange cartridges.The eluate was analyzed on an Agilent ZORBAX Eclipse Plus Phenyl-Hexyl column in 3 min.Adrenaline,noradrenaline,dopamine,metanephrine,normetanephrine,and their deuterated internal standards were monitored in positive electrospray ionization mode by multiple reaction monitoring(MRM).No evidence of ion suppression was observed.The assay was linear up to 5μmol/L for adrenaline,5μmol/L for noradrenaline,6.1μmol/L for dopamine,5.6μmol/L for metanephrine,and 34.6μmol/L for normetanephrine,with lower limits of quantification of 5,5,12,6 and 7nmol/L,respectively.The intra-day and inter-day precisions for all analytes ranged from 0.59%to 4.64%and1.98%to 4.80%,respectively.External quality assurance samples were assayed and showed excellent agreement with the target values.This simple method provides an improved assay for determining urine catecholamines and metanephrines. 展开更多
关键词 liquid chromatography-tandem mass spectrometry (LC-MS/MS) METANEPHRINES CATECHOLAMINES PHEOCHROMOCYTOMA URINE
下载PDF
Simultaneous determination of 15 pesticide residues in Chinese cabbage and cucumber by liquid chromatography-tandem mass spectrometry utilizing online turbulent flow chromatography 被引量:5
5
作者 Sufang Fan Junmei Ma +5 位作者 Meirong Cao Juan Wang Leilei Zhang Yan Zhang Qiang Li Jia Chen 《Food Science and Human Wellness》 SCIE 2021年第1期78-86,共9页
In this experiment,a liquid chromatography tandem mass spectrometry method was built to determine 15 pesticide residues in Chinese cabbage and cucumber samples based on online turbulent flow chromatography purificatio... In this experiment,a liquid chromatography tandem mass spectrometry method was built to determine 15 pesticide residues in Chinese cabbage and cucumber samples based on online turbulent flow chromatography purification.After modified quick,easy,cheap,effective,rugged,and safe(QuEChERS)extraction,extracts were directly injected to the TLX(TurboFlow Liquid Xcalibur)system and brought to TurboFlow™columns for on-line purification and then transferred to analytical column for further separation and analysis.TurboFlow™columns types,transfer flow rate,and transfer time were optimized.Limits of detection and limits of quantification of the method obtained for 15 pesticide residues were ranged between 0.2–1.0μg/kg and 0.5–2.0μg/kg in Chinese cabbage and cucumber samples.Recoveries of pesticide residues were in range of 75.3%–103.7%.Matrix effects for 15 pesticides were in range of 5.6%–106.6%.The developed method has been successfully used for the determination of 15 pesticide residues in real samples. 展开更多
关键词 Pesticide residues Online turbulent flow chromatography liquid chromatography-tandem mass spectrometry
下载PDF
Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study 被引量:2
6
作者 Ravi Kumar Konda Babu Rao Chandu +1 位作者 B.R.Challa Chandrasekhar B.Kothapalli 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期342-349,共8页
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo... The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. 展开更多
关键词 High performance liquid chromatography mass spectrometry RASAGILINE liquid-liquid extraction
下载PDF
Determination of Steroid Hormone Residues in Fish Tissues Using Gel Permeation Chromatography and Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:3
7
作者 LI Peipei YAN Zhongyong +3 位作者 SUN Xiumei CHEN Si CHEN Yin ZHANG Xiaojun 《Journal of Ocean University of China》 SCIE CAS CSCD 2018年第5期1171-1177,共7页
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s... A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues. 展开更多
关键词 ultra performance liquid chromatography-tandem mass spectrometry anabolic hormone gel permeation chromatography fish tissue
下载PDF
Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry for Simultaneous Determination of Metformin and Glimepiride in Beagle Dog Plasma and Bioequivalence Study 被引量:1
8
作者 BAI Jing SHI Xiao-wei +3 位作者 DU Ying-feng XIANG Bai WANG Shuai CAO De-ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第3期399-405,共7页
A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glip... A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium ace- tate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, pre- cision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepi- ride in beagle dogs. 展开更多
关键词 liquid chromatography-electrospray ionization tandem mass spectrometry(LC-ESI-MS/MS) Simultaneousdetermination METFORMIN GLIMEPIRIDE GLIPIZIDE BIOEQUIVALENCE
下载PDF
Uncertainty Evaluation of Determination of Microcystin MC-LR in Environmental Samples by Solid Phase Extraction-Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry 被引量:1
9
作者 Zhao Bin Zhang Min Zhang Fuhai 《Meteorological and Environmental Research》 CAS 2016年第6期54-57,共4页
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first... To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2). 展开更多
关键词 Uncertainty SOLID phase extraction Ultra performance liquid chromatography tandem mass spectrometry MICROCYSTIN MC-LR China
下载PDF
Simultaneous determination of seven flavonoids in Epimedium by liquid chromatography-tandem mass spectrometry method 被引量:5
10
作者 Cai Sheng Wu Bao Lin Guo +1 位作者 Yu Xin Sheng Jin Lan Zhang 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第3期329-332,共4页
In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoid... In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-O-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources. 展开更多
关键词 FLAVONOIDS EPIMEDIUM liquid chromatography-electrospray ionization-mass spectrometry Quantitative determination
下载PDF
Development of a Liquid Chromatography-tandem Mass Spectrometry Method for Determination of Butoconazole Nitrate in Human Plasma and Its Application to a Pharmacokinetic Study 被引量:2
11
作者 贾萌萌 周莹 +4 位作者 何晓梦 吴义来 李虎群 谌辉 黎维勇 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2014年第3期431-436,共6页
Summary: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of butoconazole in human plasma. Human plasma samples of 0.2 μL were pretreated by a si... Summary: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of butoconazole in human plasma. Human plasma samples of 0.2 μL were pretreated by a single step protein precipitation procedure and analyzed using a high performance liquid chromatography (HPLC) electrospray tandem mass spectrometer system. The compounds were eluted isocratically on an Inertsil ODS-SP column (100 min×2.1 mm, 3 μm), ionized using a positive ion atmospheric pressure electrospray ionization source and analyzed using multiple reaction monitoring (MRM) mode. The ion transitions monitored were m/z 412.8→q65.1 for butoconazole and m/z 453.4→230.3 for the internal standard. The chromatographic run time was 3.5 min per injection, with retention time of 2.47 rain and 2.15 min for butoconazole and repaglinide, respectively. The method was validated to be linear over the range of 20 to 8000 pg/mL (r〉0.999) by using a weighted (1/x2) quadratic regression. The mean recovery rate was more than 86.7%, and the intra- and inter-day precision of the quality control samples (QCs) was less than 8.3% and the accuracy ranged from 96.0% to 110.2%, which indicated that the quantitative method was reliable and accurate. The method is simple, rapid, and has been applied successfully to a pharmacokinetics study of butoconazole nitrate suppositories in healthy Chinese females. 展开更多
关键词 liquid chromatography-tandem mass spectrometry human plasma PHARMACOKINETICS bu- toconazole nitrate
下载PDF
Rapid Quantitative Determination of Isoprene Monomer in Living Taraxacum kok-saghyz by Ultra-High Performance Liquid Chromatography Tandem Mass Spectrometry 被引量:1
12
作者 Xiang Tong Guo Tianyang +5 位作者 Zhang Xi Chen Yunhan Dong Yiyang Zhang Jichuan Ma Qiang Zhang Liqun 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS 2020年第2期30-36,共7页
Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In t... Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In this paper,a rapid and quantitative ultra-high performance liquid chromatography tandem mass spectrometry(UHPLCMS/MS)method was established for determination of macromolecular biosynthesis substrate(dimethylallyl pyrophosphate,DMAPP)and initiator(farnesyl pyrophosphate,FPP)contained in TKS.A Kromasil C18 chromatographic column was used for separation,and the multi-reaction monitoring mode(MRM)of triple quadrupole mass spectrometry was used for detection.Quantification was performed by external calibration method.The results showed that the limit of detection(LOD)and the limit of quantitation(LOQ)of DMAPP were 2.42μg/L and 7.26μg/L,respectively,and the LOQ and the LOD of FPP were 1.02μg/L and 3.05μg/L,respectively.At a concentration of 1—1000μg/L,both analytes had good determination coefficients(>0.999)of calibration curve.The recoveries of DMAPP and FPP were between 99.0%and 117.1%.In real samples detection,the contents of DMAPP and FPP in TKS samples were between 23.32—82.77μg/L and 12.03—85.67μg/L,respectively.Thus,this approach is a reliable method to quantify DMAPP and FPP in TKS. 展开更多
关键词 QUANTITATION Taraxacum kok-saghyz(TKS) ISOPRENOIDS ultra-high performance liquid chromatography tandem mass spectrometry(UHPLC-MS/MS) natural rubber(NR)
下载PDF
Stable Isotope Dilution Analysis of Gibberellin Residues in Tomato Paste by Liquid Chromatography-Tandem Mass Spectrometry 被引量:1
13
作者 SUN Li ZHAO Yan-sheng +4 位作者 NIE Xue-mei LING Yun CHU Xiao-gang SHANG De-jun DONG Ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2012年第5期797-801,共5页
An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction... An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction to high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) with electrospray ionization based stable isotope dilution analysis(SIDA). The isotope labeled internal standard can compensate for the losses during the extraction and cleanup steps and for discrimination due to ion suppression. After extraction from methanol, hydrophile lipophilic balance(HLB) solid phase extraction(SPE) column was tested for the capacity of the cleanup of the tomato paste in compared with C18 SPE column which is the common way to the detection of GAs, and the former gained better result. Spiked experiments were performed in the non-contaminated tomato pastes and the recoveries of GA3, GA4 and GA7 were 42.6%―75.0% in external standard method(ESM) and 91.1%―103.8% in internal standard method(ISM) respectively. The validities of this method were investigated and good analytical performance for the three GAs was obtained, including low limits of method detection(2 ng/g for GA3 and GA4, 0.3 ng/g for GA7), excellent linear dynamic ranges(5―500 ng/g for GA3 and GA4, 1―100 ng/g for GA7) and good relative standard deviation ranges(4.8%―9.4% for the intra-day test and 3.5%―11.9% for the inter-day test). 展开更多
关键词 GIBBERELLIN Tomato paste liquid chromatography-tandem mass spectrometry(LC-MS/MS) Stable isotope dilution analysis(SIDA)
下载PDF
Application of Liquid Chromatography-Tandem Mass Spectrometry in Determination of Veterinary Drug Residues 被引量:1
14
作者 FU Shi-jun GUO Shi-jin +1 位作者 ZHANG Zhi-mei SHEN Zhi-qiang 《Animal Husbandry and Feed Science》 CAS 2013年第2期101-104,共4页
With the long -term and irrational use of veterinary drugs and drug additives in the process of animal feeding, the veterinary drug resi- dues in animals and their additives can be ingested into the human body and pos... With the long -term and irrational use of veterinary drugs and drug additives in the process of animal feeding, the veterinary drug resi- dues in animals and their additives can be ingested into the human body and pose potential threat to human health. Detection of veterinary drug resi- dues are extremely important practical significance to protect the ecological environment and human health. In recent years, liquid chromatography -tandem mass spectrometry has been widely used in vetednary drug residue detection because of its applicability, qualitative and quantitative fea- tures as well as high sensitivity. This article summarized the application of liquid chromatography -tandem mass spectrometry in detection veterinary drug residues from feed, animal products, arid udne as well as illicit drugs and harmful additives. 展开更多
关键词 liquid chromatography-tandem mass spectrometry Veterinary Drug Residues APPLICATION
下载PDF
Liquid Chromatography-Tandem Mass Spectrometry Assay to Detect Ethyl Glucuronide in Human Fingernail: Comparison to Hair and Gender Differences 被引量:1
15
作者 Joseph Jones Mary Jones +4 位作者 Charles Plate Douglas Lewis Michael Fendrich Lisa Berger Daniel Fuhrmann 《American Journal of Analytical Chemistry》 2012年第1期83-91,共9页
Over the past decade, the use of hair specimens for the long-term detection of the alcohol biomarker ethyl glucuronide has been increasing in popularity and usage. We evaluated the usefulness of fingernail clippings a... Over the past decade, the use of hair specimens for the long-term detection of the alcohol biomarker ethyl glucuronide has been increasing in popularity and usage. We evaluated the usefulness of fingernail clippings as a suitable alterna-tive to hair for ethyl glucuronide detection. A liquid chromatography-tandem mass spectrometry method for the detection of ethyl glucuronide in fingernail clippings was fully validated and used to analyze the hair and/or fingernail specimens of 606 college-aged study participants. The limit of detection was 2 pg/mg, the limit of quantitation was 8 pg/mg and the method was linear from 8 to 2000 pg/mg. Intra- and inter-assay imprecision studies at three different concentrations (20, 40, 200 pg/mg) were all within 7.8% and all intra- and inter-assay bias studies at these levels were within 115.1% of target concentration. Ethyl glucuronide levels in fingernail (mean = 29.1 ± 55.6 pg/mg) were higher than ethyl glucuronide levels in hair (mean = 9.48 ± 22.3 pg/mg) and a correlation of the matched pairs was observed (r = 0.552, P < 0.01, n = 529). Evaluating each gender separately revealed that the correlation of male fingernail to male hair was large and significant (r = 0.782, P < 0.01, n = 195) while female hair to female fingernail was small yet sig-nificant (r = 0.249, P < 0.01, n = 334). The study results demonstrated that fingernail may be a suitable alternative to hair for ethyl glucuronide detection and may be the preferred sample type due to the lack of a gender bias. 展开更多
关键词 ALCOHOL Biomarkers liquid chromatography-tandem mass spectrometry LC-MS/MS ETHYL GLUCURONIDE Fingernail HAIR
下载PDF
High Performance Liquid Chromatography-Electrospray Ionization-Mass Spectrometric Analysis of Bilobalide and Ginkgolides in Ginkgo biloba L. Leaves 被引量:1
16
作者 卢定强 韦萍 +1 位作者 欧阳平凯 陈钧 《Journal of Chinese Pharmaceutical Sciences》 CAS 2002年第2期26-30,共5页
The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi... The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy. 展开更多
关键词 High performance liquid chromatography Electrospray ionization mass spectrometry Ginkgo terpene lactones
下载PDF
Modernization of Chinese herbal compound and the high performance liquid chromatography tandem mass spectrometry (HPLC-MS)
17
作者 LI Wen-lan1,2,3,SUN Zhi1,2,DU Juan1,2(1.Engineering Research Center of natural antineoplastic drugs,Ministry of Education,Harbin 150076,China 2.Center of Research and Development on Life Sciences and Environmental Sciences,Harbin University of Commerce,Harbin 150076,China 3.Institute of Materia Medica and Postdoctoral Programme of Harbin University of Commerce,Harbin 150076,China) 《沈阳药科大学学报》 CAS CSCD 北大核心 2008年第S1期119-119,共1页
Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is ... Chinese herbal compound is playing an important role on curing human diseases.And it has been a trend that Chinese herbal compound is being used all over the world in 21 century.However,our Chinese herbal compound is facing serious challenge for the lack of canonical system of quality criterion for Chinese herbal compound so it has been a urgent problem to set up the quality control standards and reveal therapeutic basis of Chinese herbal compound.In order to give full play to the advantages of Chinese herbal compound,modern scientific and technological is used to research of Chinese herbal compound,especially the high performance liquid chromatography tandem mass spectrometry(HPLC-MS),because it is high sensitive,rapid,and obtain more information.It is very necessary that HPLC-MS is uesed to elucidate the effective components of basic substances of Chinese Herbal Compound,and endow traditional Chinese medicine with modern scientific connotation. 展开更多
关键词 MODERNIZATION of Chinese HERBAL compound the high performance liquid chromatography tandem mass spectrometry(HPLC-MS)
下载PDF
Screening and Identifying of Nephrotoxic Compounds in Lithospermum erythrorhizon Using Live-cell Fluorescence Imaging and Liquid Chromatography Coupled with Tandem Mass Spectrometry
18
作者 ZHAO Xiao-ping JIN Ye-cheng +2 位作者 ZENG Xing ZHANG Bo-li ZHANG Yu-feng 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第4期562-565,共4页
In order to identify the potential nephrotoxic compounds in traditional Chinese medicine Lithospermum erythrorhizon,it was separated into serial fractions according to their polarities.An in vitro method was utilized ... In order to identify the potential nephrotoxic compounds in traditional Chinese medicine Lithospermum erythrorhizon,it was separated into serial fractions according to their polarities.An in vitro method was utilized to determine the nephrotoxicity of these fractions with the help of fluorescence image analysis.As a result,the primary fraction A05 and its secondary fractions C06 "C09 and C12 "C14 were found to have significant toxicity to LLC-PK1 cell line,as determined by the survive rate less than 20% after they were treated with these fractions.These potential nephrotoxic fractions were further analyzed by multistage and high resolution mass spectrometry.The main compounds in these fractions were tentatively identified to be acetylshikonin,isobutyrylshikonin,β,β'-dimethyla-cryloylshikonin,and isovalerylshikonin,which may bring nephrotoxicity. 展开更多
关键词 Traditional Chinese medicine Nephrotoxic compound liquid chromatography/ion-trap mass spectrome-try(LC/IT-MS) liquid chromatography/time-of-flight mass spectrometry(LC/TOF-MS) Lithospermum erythrorhizon
下载PDF
Determination of thyreostats in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry
19
作者 Lech RODZIEWICZ Jolanta MASLOWIECKA +1 位作者 Anna SADOWSKA Halina CAR 《色谱》 CAS CSCD 北大核心 2017年第10期1048-1054,共7页
Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC... Five thyreostats(TSs),namely tapazole,thiouracil,methylthiouracil,propylthiouracil,and phenylthiouracil,were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)in positive electrospray ionization mode.Extraction and clean-up were achieved using a ChemElut cartridge with tert-butyl methyl ether,without a derivatization step.Separation was achieved on an Acquity UPLC SS T3 column.The mobile phase was acetonitrile and water containing 0.2%(v/v)formic acid.The mass spectrometer was operated in multiple reaction monitoring mode.Urine samples were spiked with TS solution at levels corresponding to 5,10,15,and 20μg/L.The accuracy(internal standard corrected)ranged from 92%to 107%,with a repeatability precision(relative standard deviation,RSD)less than 15%for all five analytes.The RSDs within-laboratory reproducibility was less than 26%.The decision limits(CCα)and detection capabilities(CCβ)were obtained from a calibration curve and were in the ranges of 3.1-6.1μg/L and 4.0-7.4μg/L,respectively.The CCαand CCβvalues were below the recommended concentration,which was set at 10μg/L.The results show that the described method is suitable for the direct detection of TSs in bovine urine.This method can also be used to determine TSs in porcine urine. 展开更多
关键词 ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) thyreostats (TSs) URINE
下载PDF
Rapid quantification of the metabolite of valacyclovir hydrochloride in human plasma by liquid chromatography-tandem mass spectrometry
20
作者 Yuan Tian1,2,Hui Lin1,2,Xue-Yu Zhang1,2,Zun-Jian Zhang1,2,Guo-Guang Mao31. Key Laboratory of Drug Quality Control and Pharmacovigilance (China Pharmaceutical University),Ministry of Education,Nanjing 210009 2. Center for Instrumental Analysis,China Pharmaceutical University,Nanjing 210009 3. Department of Clinical Pharmacology,Wannan Medical College,Wuhu 241000,China. 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第2期83-90,共8页
Objective To establish a rapid,sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of acyclovir (the metabolite of valacyclovir hydrochloride) in human plasma... Objective To establish a rapid,sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of acyclovir (the metabolite of valacyclovir hydrochloride) in human plasma. Methods After addition of ganciclovir as internal standard (IS),plasma samples were prepared by one-step protein precipitation using acetonitrile as precipitant,followed by an isocratic elution with 0.1% formic acid solution-methanol (95∶5,v/v) on an Agilent ZORBAX SB-C18 (150mm×2.1mm i.d.,3.5μm) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 226.2→152.1 for acyclovir and m/z 256.2→152.1 for the IS. Results The analytical results demonstrated a good linearity over the ranges from 0.005 to 4μg/mL (r=0.9999) for valacyclovir hydrochloride. The relative standard deviations (RSD) of intra-batch and inter-batch were less than 4.06% and 9.23%,respectively. The limit of detection and lower limit of quantification in human plasma were 2ng/mL and 5ng/mL,respectively. Conclusion The method was simple,sensitive,accurate and reproducible and has been successfully applied to a bioequivalence study of valacyclovir hydrochloride capsules in Chinese healthy male volunteers. 展开更多
关键词 valacyclovir hydrochloride ACYCLOVIR liquid chromatography-tandem mass spectrometry method validation human plasma
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部