期刊文献+
共找到51,840篇文章
< 1 2 250 >
每页显示 20 50 100
Screening potential mitochondria-targeting compounds from traditional Chinese medicines using a mitochondria-based centrifugal ultrafiltration/liquid chromatography/mass spectrometry method 被引量:5
1
作者 Xing-Xin Yang Yu-Zhen Zhou +5 位作者 Feng Xu Jie Yu Gegentana Ming-Ying Shang Xuan Wang Shao-Qing Cai 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2018年第4期240-249,共10页
Mitochondria regulate numerous crucial cell processes, including energy production, apoptotic cell death, oxidative stress, calcium homeostasis and lipid metabolism. Here, we applied an efficient mitochondria-based ce... Mitochondria regulate numerous crucial cell processes, including energy production, apoptotic cell death, oxidative stress, calcium homeostasis and lipid metabolism. Here, we applied an efficient mitochondria-based centrifugal ultrafiltration/liquid chromatography/mass spectrometry(LC/MS) method,also known as screening method for mitochondria-targeted bioactive constituents(SM-MBC). This method allowed searching natural mitochondria-targeting compounds from traditional Chinese medicines(TCMs), including Puerariae Radix(PR) and Chuanxiong Radix(CR). A total of 23 active compounds were successfully discovered from the two TCMs extracts. Among these 23 hit compounds, 17 were identified by LC/MS, 12 of which were novel mitochondria-targeting compounds. Among these, 6 active compounds were analyzed in vitro for pharmacological tests and found able to affect mitochondrial functions. We also investigated the effects of the hit compounds on Hep G2 cell proliferation and on loss of cardiomyocyte viability induced by hypoxia/reoxygenation injury. The results obtained are useful for in-depth understanding of mechanisms underlying TCMs therapeutic effects at mitochondria level and for developing novel potential drugs using TCMs as lead compounds. Finally, we showed that SM-MBC was an efficient protocol for the rapid screening of mitochondria-targeting constituents from complex samples such as PR and CR extracts. 展开更多
关键词 MITOCHONDRIA Bioactive constituents Traditional Chinese medicines Centrifugal ultrafiltration liquid chromatography/mass spectrometry
下载PDF
Biological Fingerprinting Analysis of Interaction Between Taxoids in Taxus and Microtubule Protein by Microdialysis Coupled with High-performance Liquid Chromatography/Mass Spectrometry for Screening Antimicrotubule Agents 被引量:1
2
作者 LEI Xiao-yuan KONG Liang +2 位作者 SU Xing-ye GUO Ming ZOU Han-fa 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2008年第4期411-419,共9页
Some natural products, such as traditional Chinese medicines(TCMs), contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies. A quick and con... Some natural products, such as traditional Chinese medicines(TCMs), contain compounds with anticancer activity and have attracted a great interest in recent years as alternative anticancer therapies. A quick and convenient assay for screening antimicrotubule compounds in which in vitro microdialysis/high-performance liquid chromatography (HPLC) is used to monitor the binding of the compounds extracted from TCM Taxus cuspidata Siebold & Zucc(Taxus) to microtubules is reported. It was observed that the extract of Taxus contains at least five compounds which have affinity interaction with microtubules by biological fingerprinting analysis, and they were identified as the taxoids of taxol, baccatin III, 10-deacetylbaccatin Ⅲ(10-DAB), cephalomannine and 7-epi-10-deacetyltaxol (7-epi-10-DAT) based on the comparison of their high-performance liquid chromatographic/mass spectrometric and UV spectra with those of the standard samples, both assembly-promoting and disassembly-inhibiting characteristics of those compounds were evaluated. It was observed that baccatin Ⅲ and 10-DAB bound to microtubules and the binding degrees were influenced by GTP. Competitive binding behavior of taxol with other four taxoids to microtubules was also investigated. 展开更多
关键词 Microdialysis/high-performance liquid chromatography(HPLC) Biological fingerprinting analysis TAXOIDS MICROTUBULE TAXUS
下载PDF
Derivatization in Liquid Chromatography/Mass Spectrometric Analysis of Neurosteroids 被引量:5
3
作者 Kuniko MITAMURA, Kazutake SHIMADA (Faculty of Pharmaceutical Sciences, Kanazawa University 13 1, Takara machi, Kanazawa 920 0934, Japan) 《色谱》 CAS CSCD 北大核心 2001年第6期508-512,共5页
Liquid chromatography/mass spectrometry (LC/MS) is now considered to be the most promising analytical method for the determination of biological substances, especially nonvolatile or highly polar substances However, s... Liquid chromatography/mass spectrometry (LC/MS) is now considered to be the most promising analytical method for the determination of biological substances, especially nonvolatile or highly polar substances However, some compounds do not show enough sensitivity in LC/MS and soft ionization methods commonly used in LC/MS, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), sometimes do not give satisfactory structural information This report presents an overview of the derivatization methods in the LC/MS analysis of neurosteroids or neuroactive neurosteroids, which are synthesized and accumulated in the nervous system The derivatization of pregnenolone 3 sulfate, one of these steroids, with 4 ( N,N dimethylaminosulfonyl) 7 hydrazino 2,1,3 benzoxadiazole gave a satisfactory sensitivity during the quantitative analysis using LC/ESI MS The obtained results are much lower than those previously obtained using gas chromatography/mass spectrometry or radioimmunoassay On the other hand, the derivatization to acetate was useful for the treatment of labile catechol estrogens in rat brains and gave enough structural information in LC/APCI MS, which confirmed the existence of catechol estrogens in mammalian 展开更多
关键词 神经类固醇 分析 液相色谱 质谱 联用技术 衍生化方法
下载PDF
Determination of Voriconazole in Human Plasma by Liquid Chromatography Tandem Mass Spectrometry: Application in Therapeutic Drug Monitoring
4
作者 Waleed Alhussaini Ezzeldeen Ghanem +4 位作者 Magd Alsahly Amani Kurdi Eman Alharbi Imadul Islam Majed Aljeraisy 《American Journal of Analytical Chemistry》 2023年第9期378-389,共12页
A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with flucona... A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM. 展开更多
关键词 VORICONAZOLE Human Plasma liquid chromatography Tandem mass Spectrometry Therapeutic Drug Monitoring
下载PDF
Determination of egg and milk allergen in food products by liquid chromatography-tandem mass spectrometry based on signature peptides and isotope-labeled internal standard
5
作者 Sufang Fan Junmei Ma +4 位作者 Zhuo Liu Yawei Ning Meicong Cao Qiang Li Yan Zhang 《Food Science and Human Wellness》 SCIE CSCD 2023年第3期728-736,共9页
The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLD... The aim of this work was to develop a liquid chromatography-tandem mass spectrometry method for the determination of milk allergen and egg allergen in food products.Signature peptides GGLEPINFQTAADQAR,VGINYWLAHK,VLVLDTDYK,FFVAPFPEVFGK,and NAVPITPTLNR were confirmed and synthesized as the quantitative peptide of ovalbumin,α-lactalbumin,β-lactoglobulin,α_(S1)-casein andα_(S2)-casein,the relative isotope-labeled internal standards were used in the quantitative analysis.Linear range was in the range of0.5-5000.0 nmol/L for egg and milk allergen in bread,cake,cookie,rice crust and wheat flour samples with free from egg and milk,the limits of detection of milk allergens and egg allergen were in the range between0.94 mg/100 g and 56.71 mg/100 g,limits of quantification of milk allergens and egg allergen were in the range between 2.36 mg/100 g and 141.78 mg/100 g.The recoveries ranged from 76.7%to 122.8%,the relative standard deviations were in the range of 1.60%-15.60%.The developed method has been successfully used for the detection of egg and milk allergen in various food samples. 展开更多
关键词 liquid chromatography-tandem mass spectrometry Egg and milk allergen Signature peptides Isotope-labeled internal standards
下载PDF
Simultaneous Determination of 14 β-Receptor Agonists Residues in Mutton by High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS)
6
作者 Zhe MENG Jianhua WANG +5 位作者 Bo LIU Yuhang GUO Haoshuang DONG Pingyang SHAN Dawei WANG Yajuan SONG 《Agricultural Biotechnology》 CAS 2023年第5期55-58,共4页
[Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-g... [Objectives]A high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)method was established for the determination of 14β-receptor agonist residues in mutton.[Methods]Samples were hydrolyzed byβ-glucuronidase and extracted with 5%acetic acid-acetonitrile(1:99,V/V)solution.An Eclipse plus C 18 column was used for separation,and the MRM mode was used for qualitative analysis,and the external standard method was used for quantitative analysis of matrix standard solutions.[Results]Under the optimal conditions,the retention time of the 14 kinds ofβ-receptor agonists ranged from 1.0 to 9.5 min.When the mass concentration was in the range of 0.05-0.50μg/ml,the linear relationship ofβ-receptor agonists was good,with correlation coefficients(r)≥0.9992.The detection limits of the method were in the range of 0.04-0.87μg/kg,and the quantitative limits were in the range of 0.35-1.86μg/kg.The average recovery values were in the range of 82.8%-108.9%,with RSDs(n=6)in the range of 1.9%-6.7%.[Conclusions]The method is simple,sensitive,reproducible,accurate,and can be used for simultaneous determination of the 14 kinds ofβ-receptor agonist residues in mutton. 展开更多
关键词 MUTTON High performance liquid chromatography-tandem mass spectrometry β-receptor agonist RESIDUE
下载PDF
Determination of Oleuropein in Cosmetics by Ultra Performance Liquid Chromatography-Triple Quadrupole Tandem Mass Spectrometry
7
作者 Pan Lijing Chen Weiwei Yuan Minjia 《China Detergent & Cosmetics》 CAS 2023年第4期30-36,共7页
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte... An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics. 展开更多
关键词 ultra performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS) OLEUROPEIN COSMETICS
下载PDF
Analysis of ganciclovir and its related substances using high performance liquid chromatography and liquid chromatography-mass spectrometry methods 被引量:1
8
作者 Cheng-Ping Li1,2,Mao Mao1,Lan-Jun Zheng1,Wei-Guang Shan11.College of Pharmaceutical Sciences,Zhejiang University of Technology,Hangzhou 310032 2.College of Biology and Environment Engineering,Zhejiang Shuren University,Hangzhou 310015,China 《Journal of Pharmaceutical Analysis》 SCIE CAS 2010年第4期218-222,共5页
Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 co... Objective High performance liquid chromatography(HPLC)and liquid chromatography-mass spectrometry(LC/MS)methods were developed for the determination of ganciclovir and its related substances.Methods A Hypersil ODS2 column(4.6 mm×250 mm,5 μm)was used with a mobile phase of 0.02 M potassium dihydrogen phosphate buffer(pH 6.0)-methanol(92∶8)at a flow rate of 1.0 mL/min,and UV detector set at 254 nm was used for monitoring the eluents.Results The method was simple,rapid,selective and capable of separating all related substances at trace level with a detection limit of 0.04 μg/mL.It has been validated with respect to accuracy,precision,linearity,and limits of detection and quantification.The linearity range was 10.2-153.0 μg/mL with r=0.9998.The percentage recoveries ranged from 96.7% to 101.6%,and RSD was 1.24%-1.96%(n=5).Conclusion The method was found to be suitable not only for monitoring the reactions during the process development but also for quality control of ganciclovir.For identification of related substances,LC/MS was used.The mainly related substances of ganciclovir active pharmaceutical ingredients(API)were determined as guanine,(1,3-dioxolan-4-yl)methyl acetate,and diacetyl guanine. 展开更多
关键词 GANCICLOVIR related substances high performance liquid chromatography high performance liquid chromatography/mass spectrometry
下载PDF
Efficient and selective extraction of uranium from seawater based on a novel pulsed liquid chromatography radionuclide separation method 被引量:2
9
作者 Jian‑Hua Ye Tao Yu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第2期13-27,共15页
The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation met... The novel pulsed liquid chromatography radionuclide separation method presented here provides a new and promising strategy for the extraction of uranium from seawater.In this study,a new chromatographic separation method was proposed,and a pulsed nuclide automated separation device was developed,alongside a new chromatographic column.The length of this chromatographic column was 10 m,with an internal warp of 3 mm and a packing size of 1 mm,while the total separation units of the column reached 12,250.The most favorable conditions for the separation of nuclides were then obtained through optimizing the separation conditions of the device:Sample pH in the column=2,sample injection flow rate=5.698 mL/min,chromatographic column heating temperature=60℃.Separation experiments were also carried out for uranium,europium,and sodium ions in mixed solutions;uranium and sodium ions in water samples from the Ganjiang River;and uranium,sodium,and magnesium ions from seawater samples.The separation factors between the different nuclei were then calculated based on the experimental data,and a formula for the separation level was derived.The experimental results showed that the separation factor in the mixed solution of uranium and europium(1:1)was 1.088,while achieving the initial separation of uranium and europium theoretically required a 47-stage separation.Considering the separation factor of 1.50for the uranium and sodium ions in water samples from the Ganjiang River,achieving the initial separation of uranium and sodium ions would have theoretically required at least a 21-stage separation.Furthermore,for the seawater sample separation experiments,the separation factor of uranium and sodium ions was 1.2885;therefore,more than 28 stages of sample separation would be required to achieve uranium extraction from seawater.The novel pulsed liquid chromatography method proposed in this study was innovative in terms of uranium separation and enrichment,while expanding the possibilities of extracting uranium from seawater through chromatography. 展开更多
关键词 Pulsed liquid chromatography Nuclide separation Seawater uranium extraction Uranium enrichment
下载PDF
EGFR/cell membrane chromatography-online-high performance liquid chromatography/mass spectrometry method for screening EGFR antagonists from Radix Angelicae Pubescentis 被引量:5
10
作者 SiCen Wang Meng Sun +2 位作者 YanMin Zhang Jie Zhang LangChong He 《Science China Chemistry》 SCIE EI CAS 2010年第11期2357-2362,共6页
The intracellular kinase domains of the epidermal growth factor receptor(EGFR) in some tumor cells are significant targets for drug discovery.We have developed a new EGFR cell membrane chromatography(EGFR/CMC)-online-... The intracellular kinase domains of the epidermal growth factor receptor(EGFR) in some tumor cells are significant targets for drug discovery.We have developed a new EGFR cell membrane chromatography(EGFR/CMC)-online-high performance liquid chromatography/mass spectrometry(HPLC/MS) method for screening anti-EGFR antagonists from medicinal herbs such as Radix Angelicae Pubescentis.In this study,the HEK293 EGFR cells with high expression of EGFR were used to prepare cell membrane stationary phase(CMSP) in the EGFR/CMC model.The retention fractions on the EGFR/CMC model were directly analyzed by combining a 10 port columns switcher with a HPLC/MS system online.As a result,osthole from Radix Angelicae Pubescentis was found to be the active component acting on EGFR like dasatinib as the control drug.There was a good relationship between their inhibiting effects on EGFR secretion and HEK293 EGFR cell growth in vitro.This new EGFR/CMC-online-HPLC/MS method can be applied for screening anti-EGFR antagonists from TCMs,for instance,Radix Angelicae Pubescentis.It will be a useful method for drug discovery with natural medicinal herbs as a leading compound resource. 展开更多
关键词 EGFR cell membrane chromatography high performance liquid chromatography/mass SPECTROMETRY ANTI-EGFR ANTAGONISTS RADIX Angelicae Pubescentis
原文传递
Determination of urine catecholamines and metanephrines by reversed-phase liquid chromatography-tandem mass spectrometry 被引量:6
11
作者 CHEUK Man-Yung LO Yun-Chuen POON Wing-Tat 《色谱》 CAS CSCD 北大核心 2017年第10期1042-1047,共6页
The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tande... The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for determining catecholamines and metanephrines in urine to replace an existing liquid chromatographic method using electrochemical detection.Urine samples were prepared using Oasis weak-cation-exchange cartridges.The eluate was analyzed on an Agilent ZORBAX Eclipse Plus Phenyl-Hexyl column in 3 min.Adrenaline,noradrenaline,dopamine,metanephrine,normetanephrine,and their deuterated internal standards were monitored in positive electrospray ionization mode by multiple reaction monitoring(MRM).No evidence of ion suppression was observed.The assay was linear up to 5μmol/L for adrenaline,5μmol/L for noradrenaline,6.1μmol/L for dopamine,5.6μmol/L for metanephrine,and 34.6μmol/L for normetanephrine,with lower limits of quantification of 5,5,12,6 and 7nmol/L,respectively.The intra-day and inter-day precisions for all analytes ranged from 0.59%to 4.64%and1.98%to 4.80%,respectively.External quality assurance samples were assayed and showed excellent agreement with the target values.This simple method provides an improved assay for determining urine catecholamines and metanephrines. 展开更多
关键词 liquid chromatography-tandem mass SPECTROMETRY (LC-MS/MS) METANEPHRINES CATECHOLAMINES PHEOCHROMOCYTOMA URINE
下载PDF
Offline two-dimensional liquid chromatography coupled with ion mobility-quadrupole time-of-flight mass spectrometry enabling fourdimensional separation and characterization of the multicomponents from white ginseng and red ginseng 被引量:9
12
作者 Tiantian Zuo Chunxia Zhang +7 位作者 Weiwei Li Hongda Wang Ying Hu Wenzhi Yang Li Jia Xiaoyan Wang Xiumei Gao Dean Guo 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2020年第6期597-609,共13页
Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensi... Inherent complexity of plant metabolites necessitates the use of multi-dimensional information to accomplish comprehensive profiling and confirmative identification.A dimension-enhanced strategy,by offline two-dimensional liquid chromatography/ion mobility-quadrupole time-of-flight mass spectrometry(2 D-LC/IM-QTOF-MS)enabling four-dimensional separations(2 D-LC,IM,and MS),is proposed.In combination with in-house database-driven automated peak annotation,this strategy was utilized to characterize ginsenosides simultaneously from white ginseng(WG)and red ginseng(RG).An offline 2 DLC system configuring an Xbridge Amide column and an HSS T3 column showed orthogonality 0.76 in the resolution of ginsenosides.Ginsenoside analysis was performed by data-independent high-definition MSE(HDMSE)in the negative ESI mode on a Vion?IMS-QTOF hybrid high-resolution mass spectrometer,which could better resolve ginsenosides than MSEand directly give the CCS information.An in-house ginsenoside database recording 504 known ginsenosides and 58 reference compounds,was established to assist the identification of ginsenosides.Streamlined workflows,by applying UNIFI?to automatedly annotate the HDMSEdata,were proposed.We could separate and characterize 323 ginsenosides(including 286 from WG and 306 from RG),and 125 thereof may have not been isolated from the Panax genus.The established 2 D-LC/IM-QTOF-HDMSEapproach could also act as a magnifier to probe differentiated components between WG and RG.Compared with conventional approaches,this dimensionenhanced strategy could better resolve coeluting herbal components and more efficiently,more reliably identify the multicomponents,which,we believe,offers more possibilities for the systematic exposure and confirmative identification of plant metabolites. 展开更多
关键词 Dimension-enhanced strategy Multicomponent characterization GINSENOSIDE Offline two-dimensional liquid chromatography Ion mobility-quadrupole time-of-flight mass spectrometry In-house database
下载PDF
Determination of Tetracyclines and Their Epimers in Agricultural Soil Fertilized with Swine Manure by Ultra-High-Performance Liquid Chromatography Tandem Mass Spectrometry 被引量:9
13
作者 ZHENG Wen-li ZHANG Li-fang +2 位作者 ZHANG Ke-yu WANG Xiao-yang XUE Fei-qun 《Journal of Integrative Agriculture》 SCIE CSCD 2012年第7期1189-1198,共10页
A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxyte... A rapid, sensitive and specific ultra-high-performance liquid chromatography tandem mass spectrometry (UPLC-MS) method was developed for the analysis of tetracycline antibiotics, including tetracycline (TC), oxytetracycline (OTC), chlortetracycline (CTC) and their 4-epimers (4-epiTCs) in agricultural soil fertilized with swine manure. Soil samples were extracted and cleaned-up with 10 mL EDTA-McIlvaine buffer solution (pH 4.0), then cleaned-up and pre-concentrated using the Oasis MAX cartridge and then eluted with 1 mL solution by mixing formic acid, methanol and water at a ratio of 2:15:83 (v/v/v). The purified samples were separated by an ACQUITY UPLC BEH C18 column using acetonitrile and water containing 0.1% formic acid mobile phase and detected by a single quadrupole MS. The limits of detection for the soil extraction method (LODsoil) ranged from 0.6-2.5 lag kg-~ with recoveries from 23.3-159.2%. Finally, the method was applied to an agricultural field in an area with intensive pig-fattening farming. Tetracyclines were detected in soil from 2.8 to 42.4 μg kg-1 soil. These results demonstrate that soil from swine farms can become severely contaminated with tetracycline antibiotics and their metabolites. 展开更多
关键词 TETRACYCLINES EPIMERS ultra performance liquid chromatography SOIL solid phase extraction
下载PDF
Establishing a protein expression profile database for the normal human pituitary gland using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry 被引量:2
14
作者 Rong Xie Wei Xu +4 位作者 Weimin Bao Hang Liu Luping Chen Yiwen Shen Jianhong Zhu 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第36期2922-2928,共7页
In this study, we selected adult normal pituitary gland tissues from six patients during operations for pituitary microadenomas via the transsphenoidal approach for extended normal pituitary tissue resection around th... In this study, we selected adult normal pituitary gland tissues from six patients during operations for pituitary microadenomas via the transsphenoidal approach for extended normal pituitary tissue resection around the tumor, and analyzed the protein expression of human normal pituitary using two-dimensional high-performance liquid chromatography combined with LTQ-Orbitrap mass spectrometry proteomics technology. The ten most highly expressed proteins in normal human pituitary were: alpha 3 type VI collagen isoform 5 precursor (abundance among tall pituitary proteins 1.30%), fibrinogen beta chain preproprotein (0.99%), vimentin (0.73%), prolactin (0.69%), ATP synthase, H~ transporting and mitochondrial F1 complex beta subunit precursor (0.52%), keratin I (0.49%), growth hormone (0.45%), carbonic anhydrase I (0.40%), heat shock protein 90 kDa I (0.31%), and annexin V (0.30%). Based on the biological function classifications of these proteins, the top three categories by content were neuroendocrine proteins (abundance among all pituitary proteins, 40.1%), catalytic and metabolic proteins (28.3%), and cell signal transduction proteins (9.8%). Based on cell positioning classification, the top three categories were cell organelle (24.5%) membrane (20.8%), and cytoplasm (13.0%). Based on biological process classification, the top three categories of proteins are involved in physiological processes (42.9%), cellular processes (40.4%), and regulation of biological processes (9.1%). Our experimental findings indicate that a protein expression profile database of normal human pituitary can be precisely and efficiently established by proteomics technology. 展开更多
关键词 two-dimensional high-performance liquid chromatography mass spectrum pituitary gland PROTEINS PROTEOMICS hypophyseal tumor physiological function pathological mechanism
下载PDF
Simultaneous determination of 15 pesticide residues in Chinese cabbage and cucumber by liquid chromatography-tandem mass spectrometry utilizing online turbulent flow chromatography 被引量:5
15
作者 Sufang Fan Junmei Ma +5 位作者 Meirong Cao Juan Wang Leilei Zhang Yan Zhang Qiang Li Jia Chen 《Food Science and Human Wellness》 SCIE 2021年第1期78-86,共9页
In this experiment,a liquid chromatography tandem mass spectrometry method was built to determine 15 pesticide residues in Chinese cabbage and cucumber samples based on online turbulent flow chromatography purificatio... In this experiment,a liquid chromatography tandem mass spectrometry method was built to determine 15 pesticide residues in Chinese cabbage and cucumber samples based on online turbulent flow chromatography purification.After modified quick,easy,cheap,effective,rugged,and safe(QuEChERS)extraction,extracts were directly injected to the TLX(TurboFlow Liquid Xcalibur)system and brought to TurboFlow™columns for on-line purification and then transferred to analytical column for further separation and analysis.TurboFlow™columns types,transfer flow rate,and transfer time were optimized.Limits of detection and limits of quantification of the method obtained for 15 pesticide residues were ranged between 0.2–1.0μg/kg and 0.5–2.0μg/kg in Chinese cabbage and cucumber samples.Recoveries of pesticide residues were in range of 75.3%–103.7%.Matrix effects for 15 pesticides were in range of 5.6%–106.6%.The developed method has been successfully used for the determination of 15 pesticide residues in real samples. 展开更多
关键词 Pesticide residues Online turbulent flow chromatography liquid chromatography-tandem mass SPECTROMETRY
下载PDF
Rapid analysis of fifteen sulfonamide residues in pork and fish samples by automated on-line solid phase extraction coupled to liquid chromatography–tandem mass spectrometry 被引量:6
16
作者 Junmei Ma Sufang Fan +3 位作者 Lei Sun Liangna He Yan Zhang Qiang Li 《Food Science and Human Wellness》 SCIE 2020年第4期363-369,共7页
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples... The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish. 展开更多
关键词 liquid chromatography–tandem mass SPECTROMETRY On-line solid phase extraction SULFONAMIDES Internal standard quantification
下载PDF
Study on liquid–liquid two-phase mass transfer characteristics in the microchannel with deformed insert
17
作者 Qinyan Wang Yang Jin +2 位作者 Jun Li Yongbo Zhou Ming Chen 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第2期114-126,共13页
In this work, the liquid-liquid two-phase mass transfer characteristics in the microchannel with deformed insert were studied. The experiment used di-(2-ethylhexyl) phosphoric acid/kerosene-Cu^(2+)as the mass transfer... In this work, the liquid-liquid two-phase mass transfer characteristics in the microchannel with deformed insert were studied. The experiment used di-(2-ethylhexyl) phosphoric acid/kerosene-Cu^(2+)as the mass transfer evaluation system. The effects of some key factors such as the total flow velocity,channel inner diameter, channel length, insert diameter, extractant concentration on the extraction efficiency and mass transfer coefficient were systematically investigated. Compared with a simple microreactor, the liquid-liquid mass transfer enhancement effect of the insert was quantitatively analyzed. The study found that the regular deformation of the insert could cause fluid interface deformation and promote flow state chaos, effectively increasing the mass transfer rate. And the enhancement effect of the insert was more significant at high flow velocities. The highest mass transfer coefficient in the microchannel with deformed insert was 7.886 s^(-1), the enhancement factor could reach 4.17. And only needed 0.095 s to approach the extraction equilibrium. The deformed center insert exhibited an effective liquid-liquid mass transfer enhancement effect, which can be used as a micro-chemical process enhancement method to be applied in the fields of higher throughput mass transfer and chemical synthesis,and at the same time provide ideas for development and structural optimization of microreactors. 展开更多
关键词 MICROCHANNEL INSERT DEFORMATION liquidliquid extraction mass transfer enhancement
下载PDF
Development of a Liquid Chromatography-tandem Mass Spectrometry Method for Determination of Butoconazole Nitrate in Human Plasma and Its Application to a Pharmacokinetic Study 被引量:2
18
作者 贾萌萌 周莹 +4 位作者 何晓梦 吴义来 李虎群 谌辉 黎维勇 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2014年第3期431-436,共6页
Summary: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of butoconazole in human plasma. Human plasma samples of 0.2 μL were pretreated by a si... Summary: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of butoconazole in human plasma. Human plasma samples of 0.2 μL were pretreated by a single step protein precipitation procedure and analyzed using a high performance liquid chromatography (HPLC) electrospray tandem mass spectrometer system. The compounds were eluted isocratically on an Inertsil ODS-SP column (100 min×2.1 mm, 3 μm), ionized using a positive ion atmospheric pressure electrospray ionization source and analyzed using multiple reaction monitoring (MRM) mode. The ion transitions monitored were m/z 412.8→q65.1 for butoconazole and m/z 453.4→230.3 for the internal standard. The chromatographic run time was 3.5 min per injection, with retention time of 2.47 rain and 2.15 min for butoconazole and repaglinide, respectively. The method was validated to be linear over the range of 20 to 8000 pg/mL (r〉0.999) by using a weighted (1/x2) quadratic regression. The mean recovery rate was more than 86.7%, and the intra- and inter-day precision of the quality control samples (QCs) was less than 8.3% and the accuracy ranged from 96.0% to 110.2%, which indicated that the quantitative method was reliable and accurate. The method is simple, rapid, and has been applied successfully to a pharmacokinetics study of butoconazole nitrate suppositories in healthy Chinese females. 展开更多
关键词 liquid chromatography-tandem mass spectrometry human plasma PHARMACOKINETICS bu- toconazole nitrate
下载PDF
On-line trapping/capillary hydrophilic-interaction liquid chromatography/mass spectrometry for sensitive determination of RNA modifications from human blood 被引量:1
19
作者 Chubo Qi Hanpeng Jiang +2 位作者 Jun Xiong Bifeng Yuan Yuqi Feng 《Chinese Chemical Letters》 SCIE CAS CSCD 2019年第3期553-557,共5页
RNA modification has recently been proposed to play important roles in biological regulation. The detection and quantification of RNA modifications generally are challenging tasks since most of the modifications exist... RNA modification has recently been proposed to play important roles in biological regulation. The detection and quantification of RNA modifications generally are challenging tasks since most of the modifications exist in low abundance in vivo. Here we developed an on-line trapping/capillary hydrophilic-interaction liquid chromatography/electrospray ionization-mass spectrometry(on-line trapping/cHILIC/MS) method for sensitive and simultaneous quantification of RNA modifications of N^6-methyladenosine(m^6A) and 5-methylcytosine(5-mC) from human blood. The hydrophilic organic-silica hybrid monolith was prepared using sol-gel combined with "thiol-ene" click reaction for the separation of nucleosides. A poly(MAA-co-EGDMA) monolithic capillary was used as the on-line trapping column.With the developed on-line trapping/cHILIC/MS analytical platform, the detection limits of m^6A and 5-mC can reach to 0.06 fmol and 0.10 fmol. We then investigated the contents of m^6A and 5-mC in human blood RNA from healthy persons at the age of 6-14 and 60-68 years. Our results showed that both m^6A and 5-mC contents were significantly decreased in elder persons, suggesting the RNA modifications of m^6A and 5-mC are correlated to aging. 展开更多
关键词 N^6-Methyladenosine 5-Methylcytosine Hydrophilic-interaction liquid chromatography CAPILLARY monolithic column mass SPECTROMETRY
原文传递
Bio-analytical method development and validation of Rasagiline by high performance liquid chromatography tandem mass spectrometry detection and its application to pharmacokinetic study 被引量:1
20
作者 Ravi Kumar Konda Babu Rao Chandu +1 位作者 B.R.Challa Chandrasekhar B.Kothapalli 《Journal of Pharmaceutical Analysis》 SCIE CAS 2012年第5期342-349,共8页
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo... The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. 展开更多
关键词 High performance liquid chromatography mass spectrometry RASAGILINE liquid-liquid extraction
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部