期刊文献+
共找到1,314篇文章
< 1 2 66 >
每页显示 20 50 100
Upper-rim-modified thioether thiacalix[4]arene used for liquid-liquid extraction of Au(Ⅲ)and Pd(Ⅱ)in hydrochloric acid medium
1
作者 Sheng Wan Rong Xie +1 位作者 Jianhong Fan Kewen Tang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第2期110-118,共9页
Gold(Au)and palladium(Pd)play an increasing role in the production and human life;Therefore,it is of great significance to study their recovery.A 5,11,17,23-tetra-ethylthio-25,26,27,28-tetra-hydroxyl thiacalix[4]arene... Gold(Au)and palladium(Pd)play an increasing role in the production and human life;Therefore,it is of great significance to study their recovery.A 5,11,17,23-tetra-ethylthio-25,26,27,28-tetra-hydroxyl thiacalix[4]arene(TCAET)was synthesized specifically for the capture of Au(Ⅲ)and Pd(Ⅱ)from HCl medium by liquid-liquid extraction.In a 0.1 mol·L^(-1)HCl medium,the transfer of Au(Ⅲ)and Pd(Ⅱ)from the aqueous phase to the organic phase was highly efficient,with a transfer ratio of 100%for Au(Ⅲ)and 98%for Pd(Ⅱ).Furthermore,the extraction equilibrium time for Au(Ⅲ)was just 5 min.Job's method data demonstrated that TCAET formed complexes with Au(Ⅲ)and Pd(Ⅱ)in a ratio of 2:3 and 1:1,respectively,during the extraction process.TCAET showed high selectivity toward Pd(Ⅱ)and Au(Ⅲ)over other competing metal ions.Moreover,both Au(Ⅲ)and Pd(Ⅱ)could be successfully stripped from the loaded organic phases with a 1.0 mol·L^(-1)thiourea in 0.5 mol·L^(-1)HCl and 0.5 mol·L^(-1)thiourea in 0.5 mol·L^(-1)HCl,respectively.Results obtained from five consecutive extraction-stripping cycles showed good reusability of TCAET toward Au(Ⅲ)and Pd(Ⅱ)recovery.The conclusion can provide a certain reference for thiacalixarene in the recovery of precious metal species. 展开更多
关键词 arene Upper-rim modification liquid-liquid extraction Precious metal THIOETHER
下载PDF
Ten-year observation of corneal densitometry and associated factors following small incision lenticule extraction
2
作者 Xiao-Song Han Fei Xia +4 位作者 Zhuo-Yi Chen Pei-Jun Yao Dong-Mei Yang Jing Zhao Xing-Tao Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期485-490,共6页
●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equival... ●AIM:To investigate the long-term changes of corneal densitometry(CD)and its contributing elements after small incision lenticule extraction(SMILE).●METHODS:Totally 31 eyes of 31 patients with mean spherical equivalent of-6.46±1.50 D and mean age 28.23±7.38y were enrolled.Full-scale examinations were conducted on all patients preoperatively and during followup.Visual acuity,manifest refraction,axial length,corneal thickness,corneal higher-order aberrations,and CD were evaluated.●RESULTS:All surgeries were completed successfully without complications or adverse events.Ten-year safety index was 1.17±0.20 and efficacy 1.04±0.28.CD value of 0–6 mm zones in central layer was statistically significantly lower 10y postoperatively,compared with preoperative values(0–2 mmΔ=-1.62,2–6 mmΔ=-1.24,P<0.01).There were no correlations between CD values and factors evaluated.●CONCLUSION:SMILE is a safe and efficient procedure for myopia on a long-term basis.CD values get lower 10y postoperatively,whose mechanism is to be further discussed. 展开更多
关键词 MYOPIA small incision lenticule extraction corneal densitometry
下载PDF
Changes in posterior corneal elevation after small incision lenticule extraction for different myopic diopters
3
作者 Xiao-Tong Sun Yang Zhang +5 位作者 Xiao-Kun Mei Nan-Nan Zheng Ling-Zhi Niu Xiao-Li Qu Ai-Ping Song Jian Zhuo 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期491-498,共8页
●AIM:To study the changes and effect factors of posterior corneal surface after small incision lenticule extraction(SMILE)with different myopic diopters.●METHODS:Ninety eyes of 90 patients who underwent SMILE were i... ●AIM:To study the changes and effect factors of posterior corneal surface after small incision lenticule extraction(SMILE)with different myopic diopters.●METHODS:Ninety eyes of 90 patients who underwent SMILE were included in this retrospective study.Patients were allocated into three groups based on the preoperative spherical equivalent(SE):low myopia(SE≥-3.00 D),moderate myopia(-3.00 D>SE>-6.00 D)and high myopia(SE≤-6.00 D).Posterior corneal surfaces were measured by a Scheimpflug camera preoperatively and different postoperative times(1wk,1,3,6mo,and 1y).Posterior mean elevation(PME)at 25 predetermined points of 3 concentric circles(2-,4-,and 6-mm diameter)above the best fit sphere was analyzed.●RESULTS:All surgeries were completed uneventfully and no ectasia was found through the observation.The difference of myopia group was significant at the 2-mm ring at 1 and 3mo postoperatively(1mo:P=0.017;3mo:P=0.018).The effect of time onΔPME was statistically significant(2-mm ring:P=0.001;4-mm ring:P<0.001;6-mm ring:P<0.001).The effect of different corneal locations onΔPME was significant except 1wk postoperatively(1mo:P=0.000;3mo:P=0.000;6mo:P=0.001;1y:P=0.001).Posterior corneal stability was linearly correlated with SE,central corneal thickness,ablation depth,residual bed thickness,percent ablation depth and percent stromal bed thickness.●CONCLUSION:The posterior corneal surface changes dynamically after SMILE.No protrusion is observed on the posterior corneal surface in patients with different degrees of myopia within one year after surgery.SMILE has good stability,accuracy,safety and predictability. 展开更多
关键词 MYOPIA posterior corneal elevation corneal ectasia small incision lenticule extraction
下载PDF
Small-scale fire tests in the underwater tunnel section model with new sidewall smoke extraction
4
作者 Shunyu Yue Ruifeng Miao +2 位作者 Huihang Cheng Maohua Zhong Xiujun Yang 《Deep Underground Science and Engineering》 2024年第2期247-254,共8页
The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the t... The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the tunnel has a new smoke exhaust system that combines a horizontal smoke exhaust cross section at the top and sidewall smoke exhaust holes.In order to evaluate the potential fire hazards of this type of tunnel,a 1:30 tunnel model was established and 140 smallscale experiments on underwater tunnel fires were conducted.By changing the fire power,fire location,and fan operation mode,different scenarios of submarine immersed tunnel fire were simulated and the related key parameters such as fire smoke diffusion behavior and smoke temperature distribution were studied.On this basis,the optimal smoke control strategy was proposed for different fire scenarios.The research results indicate that the new smoke exhaust system can fully utilize the smoke flow characteristics,significantly improve smoke exhaust efficiency,and increase available evacuation time,thus further enhancing the fire safety of super large cross-section subsea tunnels. 展开更多
关键词 sidewall smoke extraction system small‐scale fire tests smoke control
下载PDF
Analysis of Ultrasonic Emulsification Surgery and Small Incision Cataract Extracapsular Extraction Surgery for Cataract Clinical Treatment Level Improvement
5
作者 Chunyan Ji 《Journal of Clinical and Nursing Research》 2024年第2期196-200,共5页
Objective:To analyze the efficacy of ultrasonic emulsification and small incision cataract extracapsular extraction in cataract patients.Methods:96 cataract patients admitted from May 2021 to May 2023 were selected an... Objective:To analyze the efficacy of ultrasonic emulsification and small incision cataract extracapsular extraction in cataract patients.Methods:96 cataract patients admitted from May 2021 to May 2023 were selected and randomly grouped into group A(ultrasonic emulsification)and group B(small-incision extracapsular cataract extraction),with 48 cases each.Results:At 1 week,1-month,and 3 months post-operation,the visual acuity of group A was higher and the astigmatism value was lower than that of group B(P<0.05);at 12h,24h,and 48h post-operation,the intraocular pressure of group A was higher than that of group B(P<0.05);the thickness of macular area of group A was lower than that of group B at 1 week and 1-month post-operation(P<0.05).Conclusion:Ultrasonic emulsification in cataract patients was slightly better than small incision cataract extracapsular extraction in correcting astigmatism,improving visual acuity,and regulating macular thickness.However,due to the high energy of ultrasonic emulsification,the risk of complications such as high postoperative intraocular pressure was higher.Small-incision extracapsular cataract extraction has better application value in economically disadvantaged areas. 展开更多
关键词 CATARACT Cataract ultrasonic emulsification small incision cataract extracapsular extraction Therapeutic efficacy
下载PDF
Postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens implantation versus small incision lenticule extraction in myopic eyes:a Meta-analysis 被引量:2
6
作者 Hong-Yu Li Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期442-452,共11页
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W... AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group. 展开更多
关键词 implantable collamer lens small incision lenticule extraction MYOPIA refractive surgery META-ANALYSIS
下载PDF
The extraction of aromatics using N-methylpyrrolidone: Liquid-liquidequilibrium determination and mechanism exploration 被引量:1
7
作者 Yanjing Li Shilong Dong +3 位作者 Lili Wang Xiaoyan Sun Wenying Zhao Shuguang Xiang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第12期117-127,共11页
LLE data of cyclooctane/3-methylpentane + benzene/toluene + N-methylpyrrolidone (NMP) at 298.15 Kand 313.15 K under a pressure of 101.3 kPa were measured in this work. The Othmer-Tobias and Handequations were adopted ... LLE data of cyclooctane/3-methylpentane + benzene/toluene + N-methylpyrrolidone (NMP) at 298.15 Kand 313.15 K under a pressure of 101.3 kPa were measured in this work. The Othmer-Tobias and Handequations were adopted to validate the reliability of LLE data, where the correlation coefficients (R2) wereclose to unity, indicating the high reliability of the experimental data. The experimental data were analyzed using the distribution coefficient (D) and separation factor (S), and the effect of NMP extracting benzene and toluene from aromatics was explored. Meanwhile, the reason for the different extractionefficiencies of benzene and toluene using NMP was analyzed by quantum chemical calculations. TheNRTL and UNIQUAC thermodynamic models were used to correlate the liquid–liquid equilibrium data,and the relevant binary interaction parameters were obtained. The calculated root mean square deviation(RMSD) were all less than 0.0063, indicating that the obtained binary interaction parameters can be usedto simulate and calculate the extraction of aromatics using NMP. 展开更多
关键词 extraction liquid-liquid equilibrium Thermodynamic models Quantum chemistry calculation
下载PDF
Small incision lenticule extraction and femtosecond-assisted laser in situ keratomileusis in patients with deep corneal opacity:case series 被引量:2
8
作者 Zhi Fang Xiao-Ying He Wei Han 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第2期301-308,共8页
AIM:To report the safety,efficacy,and accuracy of small-incision lenticule extraction(SMILE)or femtosecondassisted laser in situ keratomileusis(FS-LASIK)for the correction of myopia or myopic astigmatism in patients w... AIM:To report the safety,efficacy,and accuracy of small-incision lenticule extraction(SMILE)or femtosecondassisted laser in situ keratomileusis(FS-LASIK)for the correction of myopia or myopic astigmatism in patients with deep corneal opacity denoted by anterior segment optical coherence tomography(AS-OCT).METHODS:Four patients with monocular corneal opacity(3 due to mechanical injury,1 due to a firecracker wound)were recruited and treated with refractive surgery(3 for SMILE,1 for FS-LASIK combined with limbal relaxing incision(LRI).Preoperative ocular manifestations,surgical details,postoperative visual outcomes,corneal opacity parameters,and corneal topography were analyzed.RESULTS:Preoperatively,spherical diopter ranged from-3.0 D to-4.75 D with cylinder ranging from-0.75 to-5.0 D,and corrected distance visual acuity(CDVA)ranging from 20/25 to 20/20.One eye’s corneal opacity was located in the central zone and three were in the mid-peripheral optical zone.Three patients underwent uneventful SMILE in both eyes,whilst one patient underwent FS-LASIK for high astigmatism in both eyes and LRI in the right eye.CDVA of the eye with corneal opacity ranged from 20/22to 20/20 one to six weeks postoperatively.Two patients achieved better CDVA and no patients lost Snellen lines.The postoperative diopter was within±0.75 D for all eyes.Significant edema existed above the corneal opacity in one eye and dissipated soon.No eccentric corneal topography or morphological anomaly of the corneal cap or flap was observed.CONCLUSION:The cases demonstrate that SMILE or FS-LASIK is safe and effective to treat myopic astigmatism combined with deep corneal opacity lesions after comprehensive preoperative evaluation and appropriate candidate selection.FS-LASIK combined with LRI is also sufficient for correcting high astigmatism due to corneal scarring. 展开更多
关键词 small incision lenticule extraction femtosecond-assisted laser in situ keratomileusis corneal opacity
下载PDF
Effectiveness and the nomogram of small incision lenticule extraction in the correction of myopic anisometropia in adults 被引量:1
9
作者 Tong Zhang Lu Zhu +12 位作者 Hang-Jia Zuo Zhi-Jun Chen Yan Ji Xin Yang Xiao-Rong Lu Qiong Wu Qing Wang Jiu-Yi Xia Meng Li Chun-Jiang Zhou Yao Wang Ke Hu Wen-Juan Wan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1838-1844,共7页
AIM:To evaluate the safety,effectiveness,and predictability of small incision lenticule extraction(SMILE)for the treatment of anisometropia,and to explore the personalized design scheme of SMILE in correcting adult my... AIM:To evaluate the safety,effectiveness,and predictability of small incision lenticule extraction(SMILE)for the treatment of anisometropia,and to explore the personalized design scheme of SMILE in correcting adult myopia anisometropia based on the nomogram.METHODS:It’s a prospective cohort study.Patients with anisometropic myopia of refractive difference≥2.0 diopters(D)who underwent SMILE between September 2020 and March 2021 were enrolled.Clinical features and visual function were assessed preoperatively and at 1wk,1,3,and 6mo after the operation.The examination included tests for uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),refractive errors,effectiveness index(preoperative CDVA/postoperative UDVA),safety index(postoperative CDVA/preoperative CDVA),nomogram and stereoscopic function.Paired t-test,Wilcoxon signed-rank test and repeated-measures analyses of variance were used for continuous variables,and Pearson Chi-squared test was used for categorical variables.RESULTS:The study involved 45 consecutive patients(average age:25.0±6.9y;82 out of 90 eyes underwent SMILE,while 8 eyes were not operated).The average preoperative spherical equivalent(SE)was-4.74±0.22 D.Six months after surgery,the effectiveness index was 1.05±0.12,and the safety index was 1.09±0.11.Seventy eyes(85.4%)exhibited SE correction error within±0.5 D.The percentage of eyes with Titmus stereoscopic function equal to or less than 200”significantly increased from 55.6%preoperatively to 88.9%postoperatively(P<0.05).There was statistically significant difference between higher myopia eyes and contralateral eyes in average nomogram value/spherical refraction ratio.CONCLUSION:SMILE is safe,effective and predictable in correcting myopic anisometropia,and it improves stereoscopic visual function of anisometropia patients.The precise and individualized design of the nomogram is a vital element to ensure the balance of both eyes after SMILE. 展开更多
关键词 refractive surgery small incision lenticule extraction ANISOMETROPIA NOMOGRAM
下载PDF
A 3-month comparison study of subjective and objective visual quality of small incision lenticule extraction and transepithelial photorefractive keratectomy in patients with low and moderate myopia 被引量:1
10
作者 Li-Xiang Wang Xiao-Li Wang +3 位作者 Jing Tang Ke Ma Hong-Bo Yin Ying-Ping Deng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第4期608-615,共8页
AIM:To compare the subjective and objective visual quality between small incision lenticule extraction(SMILE)and transepithelial photorefractive keratectomy(t PRK)in patients with low and moderate myopia.METHODS:Patie... AIM:To compare the subjective and objective visual quality between small incision lenticule extraction(SMILE)and transepithelial photorefractive keratectomy(t PRK)in patients with low and moderate myopia.METHODS:Patients undertaking SMILE or t PRK for the correction of low and moderate myopia were consecutively recruited in this prospective cohort study with a 3-month follow-up period.Objective evaluation[visual acuity test,manifest refraction,wavefront aberrations,the total cut-off value of the total modulation transfer function(MTFcut-off),and Strehl ratio(SR)]and subjective evaluation of visual quality(quality-of-life questionnaire)were conducted before surgery and at days 1,7,30,and 90 after surgery.RESULTS:A total of 47 patients(94 eyes)with SMILE and 22 patients(22 eyes)with t PRK were enrolled.The uncorrected visual acuity(UCVA)was better in SMILE patients on day 7 after surgery(1.13±0.13 vs 0.99±0.17,t=4.85,P<0.001)but was comparable at days 30 and 90.At day 90,the SMILE group had a lower spherical equivalent(SE)than the t PRK group(0.04±0.31 vs 0.19±0.43,t=2.08,P=0.042).Total higher order aberrations(HOAs)were induced in both surgical types,which were more evident in the t PRK group with 3-mm pupil diameter(0.16±0.07 vs0.11±0.05,t=4.27,P<0.001)and 5-mm pupil diameter(0.39±0.17 vs 0.36±0.11,t=2.33,P=0.022).The MTFcut-offand SR showed a trend of improvement in both SMILE and t PRK patients but were statistically better in the SMILE group with both pupil diameters.There was a significant improvement of contrast sensitivity(CS)over baseline levels at the spatial frequency of 18 cycles/degree(c/d)in the SMILE group(F=2.72,P=0.033)and at 3 c/d(F=3.03,P=0.031),12 c/d(F=3.72,P=0.013),and 18 c/d(F=4.62,P=0.004)in the t PRK group.The subjective quality of life questionnaire showed a steady improvement in the SMILE group(F=8.31,P<0.001)but not the t PRK group.CONCLUSION:SMILE and t PRK are both safe and effective ways to correct low and moderate myopia.A generally better and quicker recovery of visual quality favors the application of SMILE in qualified patients. 展开更多
关键词 corneal refractive surgery small incision lenticule extraction transepithelial photorefractive keratectomy MYOPIA visual quality
下载PDF
Comparative study of functional optical zone:small incision lenticule extraction versus femtosecond laser assisted excimer laser keratomileusis 被引量:1
11
作者 Yao-Wen Song Meng-Fan Cui +3 位作者 Yi Feng Min Qu Yan Gao Rui He 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第2期238-244,共7页
AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential as... AIM:To investigate the size of functional optical zone(FOZ)after small incision lenticule extraction(SMILE)versus femtosecond laser assisted excimer laser keratomileusis(FS-LASIK)for myopia correction and potential associated factors for FOZ.METHODS:A total of 133 patients who received corneal refractive surgery in our hospital between November 2018 and July 2021 were retrospectively enrolled.There were 63 patients(123 eyes)in SMILE group and 70patients(139 eyes)in FS-LASIK group.The size of FOZ was measured using Pentacam 3-dementional anterior segment analyzer before and 3mo after surgery,so as to analyze postoperative achieved functional optical zone(AFOZ)and its contributing parameters.RESULTS:When planned functional optical zone(PFOZ)was 6.5 mm for both groups,AFOZ was 1.45±0.27 and 1.67±0.25 mm smaller than preoperative FOZ in SMILE group and FS-LASIK group 3mo after surgery.AFOZ in SMILE group was significantly larger than that in FS-LASIK group(P<0.001).Variation of FOZ was negatively correlated with preoperative spherical equivalent(SE)and positively correlated with variation of mean keratometry value(△Km),variation of spherical aberration(△SA),and variation of Q-value(△Q,all P<0.001)in both groups.Multiple variable linear regression equations were△FOZ=1.354-0.1×pre-SE+0.336×△Q+1.462×△SA in SMILE group and△FOZ=1.512+0.137×△Q+0.468×△SA in FS-LASIK group.CONCLUSION:AFOZ is significantly smaller than preoperative FOZ in both SMILE and FS-LASIK groups.With the same PFOZ,larger AFOZ is achieved in SMILE group than in FS-LASIK group. 展开更多
关键词 functional optical zone small incision lenticule extraction femtosecondlaser assisted excimer laser keratomileusis spherical equivalent spherical aberration
下载PDF
Treatment of corneal dermoid with lenticules from small incision lenticule extraction surgery:a surgery assisted by fibrin glue
12
作者 Jiao-Lian Liu Jia-Yue Ji +4 位作者 Qing Ye Liu-Qing Wei Xin Zhong Lin-Zhi Jiang Jing Zeng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第4期547-553,共7页
AIM:To observe the clinical efficacy of the combined use of small incision lenticule extraction(SMILE)-derived lenticule patches in corneal dermoid excision,with fixation of the lenticule patches assisted by fibrin gl... AIM:To observe the clinical efficacy of the combined use of small incision lenticule extraction(SMILE)-derived lenticule patches in corneal dermoid excision,with fixation of the lenticule patches assisted by fibrin glue.METHODS:Seventeen eyes of 17 patients with corneal dermoid were treated with dermoid removal combined with SMILE-derived lenticule transplantation.All lenticule patches were fixed by fibrin glue.Ocular changes were assessed using slit lamp microscopy and anterior-segmental optical coherence tomography.The best-corrected visual acuity(BCVA)and ocular dioptric variations were examined preoperatively and postoperatively.Intraocular pressure(IOP)was also monitored in all visited time.RESULTS:Totally,18 lenticule patches were used on 17 eyes of 17 cornea dermoid patients.The mean follow-up time was 11.47±5.28mo.All lenticule patches we resuccessfullyg lued,kept on its location and maintained transparent during the follow-up time,with a consecutive epithelial cover for 1wk.Nine of the patients could coordinate visual and optometry exam well.Their preoperative BCVA is 0.60±0.35 in decimal,significantly improved to 0.80±0.26 in decimal at 6mo postoperatively(Z=-2.392,P=0.017),but the changes of their corneal astigmatism diopters showed no significance,with 2.22±1.91 D preoperatively,and 2.28±1.31 D at 6mo postoperatively(Z=-0.135,P=0.893).Limbal pannus formation occurred in 4(23.52%)cases and decreased with the application of tacrolimus eyedrops.IOP increased in 2(11.76%)cases,but well decreased by timolol maleate eyedrops.All the adult patients or guardians of minor patients were satisfied with the cosmetic improvement.CONCLUSION:Dermoid excision combined with transplantation of SMILE-derived lenticule patches using fibrin glue is a safe and effective novel tectonic keratoplasty procedure for corneal dermoid. 展开更多
关键词 corneal dermoid small incision lenticule extraction fibrin glue
下载PDF
Arc Extraction Analysis for Circularity Measurement of Small Cylindrical Parts by the Segmenting-stitching Method
13
作者 ZHAO Jiali WU Dan +2 位作者 ZHANG Liang SHEN Bobo LI Qiaolin 《Instrumentation》 2023年第3期1-11,共11页
To reduce the stitching error of circularity measurement of small cylindrical workpieces(Diameter less than 3 mm)by the segmenting-stitching method,arc contour extraction is analyzed in this paper.The coordinates of c... To reduce the stitching error of circularity measurement of small cylindrical workpieces(Diameter less than 3 mm)by the segmenting-stitching method,arc contour extraction is analyzed in this paper.The coordinates of cross-sectional circle of a small cylindrical part are segmented into several equal arcs to be obtained by a two-dimensional coordinate measuring machine.The circularity contour of the small cylindrical part can be formed by stitching a series of arc contours which are calculated by the obtained arc coordinate data.Due to the different measuring pressure angles of different measuring positions,the accuracy of obtained arc coordinate points is different.The bigger the pressure angle is,the accurate the obtained arc coordinate data are.The experiments show that the accuracy of two ends of the arc data is not as good as the central part.Therefore,the two ends of the obtained arc data are appropriately to be cut off,namely,only the central part of the arc data are extracted to be used for the stitching.As a result,the mean value of the matching coefficient is enhanced by 12%,the deviation between the overlap part of the neighbouring arc contour is reduced by 26%,and the average curvature of the arc contours is improved with the extraction method.Thus,the accuracy of the stitched circularity contour can be improved by this extraction procedure in the segmenting-stitching method for the circularity measurement of the small cylindrical parts. 展开更多
关键词 Circularity Measurement Arc extraction small Cylindrical Workpiece Segmenting-stitching Method
下载PDF
Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism 被引量:20
14
作者 Li-Kun Xia Jing Ma +2 位作者 He-Nan Liu Ce Shi Qing Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期470-477,共8页
AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-gui... AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at lmo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=-0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=-0.54, P=0.59) from lmo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at Imo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS- LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK. 展开更多
关键词 small incision lenticule extraction wavefront-guided femtosecond laser-assisted laser in situ keratomileusis femtosecond laser refractive surgery visual outcome
下载PDF
Dry eye and corneal sensitivity after small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis:a Meta-analysis 被引量:9
15
作者 Wen-Ting Cai Qing-Yu Liu +6 位作者 Cheng-Da Ren Qing-Quan Wei Jun-Ling Liu Qian-Yi Wang Ya-Ru Du Meng-Mei He Jing Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第4期632-638,共7页
AIM:To assess the corneal sensitivity and the incidences of dry eye after small incision lenticule extraction(SMILE) and femtosecond laser-assisted in situ keratomileusis(FSLASIK).METHODS:The Meta-analysis was p... AIM:To assess the corneal sensitivity and the incidences of dry eye after small incision lenticule extraction(SMILE) and femtosecond laser-assisted in situ keratomileusis(FSLASIK).METHODS:The Meta-analysis was performed using Rev Man 5.3.We searched on Pub Med from inception to March 2016.Summary weighted mean difference(WMD) and 95% confidence intervals(CIs) were used to analyze the datum.Random-effects or fixed-effects models were chosen up to between-study heterogeneity.The main outcomes were composed of the Ocular Surface Disease Index(OSDI) scores,tear film break-up time(TBUT),Schirmer Test and corneal sensitivity.RESULTS:Eight eligible studies including 772 eyes(386 in SMILE group and 386 in FS-LASIK group) were identified.The parameters have no significiant difference heterogeneity between SMILE and FS-LASIK group preoperatively.There were significant differences between the two groups in OSDI scores at one and three months postoperatively,in TBUT at one and three months postoperatively,in corneal sensitivity at one week,about one month and three months postoperatively.However,there was no significant difference observed in Schirmer Test at the follow-up periods.CONCLUSION:Compare to FS-LASIK,dry eye and the corneal sensitivity recover better in the SMILE group,in first three months after the surgery. 展开更多
关键词 dry eye corneal sensation small incision lenticule extraction femtosecond laser-assisted in situ keratomileusis META-ANALYSIS
下载PDF
Simulation of Solvent Extraction for Naphthenic Lubricating Base Oils
16
作者 Xu Xiaoling Wang Tianqi +1 位作者 Tian Qingmei Liu Yansheng 《China Petroleum Processing & Petrochemical Technology》 SCIE CAS CSCD 2023年第3期153-164,共12页
Solvent extraction is the process of separating aromatics from vacuum distillates for the production oflubricating base oils. In this study, the authors use dimethyl sulfoxide (DMSO) instead of furfural as solvent, in... Solvent extraction is the process of separating aromatics from vacuum distillates for the production oflubricating base oils. In this study, the authors use dimethyl sulfoxide (DMSO) instead of furfural as solvent, in light of itshigher selectivity, to obtain extracts with a high aromatic content for naphthenic lubricating base oils. We systematicallyinvestigated effects of the solvent-to-oil (S/O) ratio and extraction temperature on the yield of the extract, efficiency ofaromatic removal, and composition of the extracts and raffinates. The results showed that the aromatic content of extractsfor naphthenic oils could reach a high value of about 80%. The solvent maintained a high selectivity for aromatics fornaphthenic oils even under a high S/O ratio and a high extraction temperature. Moreover, the efficiency of aromatic removalfor naphthenic lubricating base oils could be enhanced by increasing either the S/O ratio or the extraction temperature,although these measures had limited effects in practice. Following this, we used the non-random two-liquid (NRTL) modelbased on the pseudo-component approach to simulate the liquid-liquid equilibrium of the system of DMSO + naphtheniclubricating base oils, and determined the parameters of binary interaction through regression based on the data on phaseequilibrium. The modeling results showed that the predicted yield, content of the solvent, and composition of the raffinatesand extracts were in good agreement with those obtained in the experiments. This validates the reliability of the model usedto represent the DMSO + naphthenic lubricating base oil system. Both the experimental data and the method of simulationreported here can help optimize the extraction of naphthenic lubricating base oils, and provide a better understanding of thecorresponding process. 展开更多
关键词 solvent extraction naphthenic lubricating base oils liquid-liquid equilibrium thermodynamic model DMSO
下载PDF
Colorimetric determination of nanomolar concentrations of silicate in natural waters after liquid-liquid extraction using methyl isobutyl ketone 被引量:2
17
作者 REN Jingling MI Tiezhu +2 位作者 DOU Weiwei LIU Sumei ZHANG Jing 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2008年第1期137-146,共10页
A sensitive solvent extraction method for the determination of nonamolar concentrations of silicate in natural waters is developed. According to the traditional aqueous silicate method, silicomolybdenum blue formed by... A sensitive solvent extraction method for the determination of nonamolar concentrations of silicate in natural waters is developed. According to the traditional aqueous silicate method, silicomolybdenum blue formed by the reaction between silicate and ammoni- um molydate and reduced by metol-sulfite reagent is extracted by methyl isobutyl ketone. The absorbance can be enhanced substantially up to 10-folds. The detection limit of silicate is 8 nmol/dm^3 , which is one tenth smaller than the traditional method, with the precision of 4.0% at a silicate level of 50 nmol/dm^3 and 3.2% at a silicate level of 6 μmol/dm^3. Comparing the calibration curves in the distilled water and seawater, it can be seen that the salt effect also exists in the extraction method. However, the salt effect is a linear function of the salinity and can be corrected by simple calibration. The proposed method is successfully applied to the determination of silicate in natural waters. Natural concentrations of arsenate, arsenite and phosphate cause negligible interference. 展开更多
关键词 SILICATE colorimetric determination liquid-liquid extraction methyl isobutyl ketone
下载PDF
Mass transfer coefficient in the eductor liquid-liquid extraction column 被引量:1
18
作者 Bahare Esmaeeli Ahad Ghaemi +1 位作者 Mansour Shirvani Mostafa Hosseinzadeh 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第12期27-35,共9页
In this research gasoil desalting was investigated from mass transfer point of view in an eductor liquid–liquid extraction column(eductor-LLE device).Mass transfer characteristics of the eductor-LLE device were evalu... In this research gasoil desalting was investigated from mass transfer point of view in an eductor liquid–liquid extraction column(eductor-LLE device).Mass transfer characteristics of the eductor-LLE device were evaluated and an empirical correlation was obtained by dimensional analysis of the dispersed phase Sherwood number.The Results showed that the overall mass transfer coefficient of the dispersed phase and extraction efficiency have been increased by increasing Sauter mean diameter(SMD)and decreasing the nozzle diameter from 2 to 1 mm,respectively.The effects of Reynolds number(R_(e)),projection ratio(ratio of the distance between venturi throat and nozzle tip to venturi throat diameter,Rpr),venturi throat area to nozzle area ratio(R_(th-n))and two phases flow rates ratio(R_(Q))on the mass transfer coefficient(K)were determined.According to the results,K increase with increasing Re and RQ and also with decreasing Rpr and R_(th-n).Semi-empirical models of drop formation,rising and coalescence were compared with our proposed empirical model.It was revealed that the present model provided a relatively good fitting for the mass transfer model of drop coalescence.Moreover,experimental data were in better agreement with calculated data with AARE value of 0.085. 展开更多
关键词 Gasoil desalting liquid-liquid extraction Eductor-LLE device Mass transfer coefficient extraction efficiency
下载PDF
Comparison of liquid-liquid extraction-thin layer chromatography with solid-phase extraction-high-performance thin layer chromatography in detection of urinary morphine 被引量:1
19
作者 Ali Ahadi Alireza Partoazar +1 位作者 Mohammad Hassan Abedi Khorasgani Seyed Vahid Shetab Boushehri 《The Journal of Biomedical Research》 CAS 2011年第5期362-367,共6页
Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tr... Liquid-liquid extraction-thin layer chromatography (LLE-TLC) has been a common and routine combined method for detection of drugs in biological materials. Solid-phase extraction (SPE) is gradually replacing the tra- ditional LLE method. High performance thin layer chromatography (HPTLC) has several advantages over TLC. The present work studied the higher efficiency of a new SPE-HPTLC method over that of a routine LLE-TLC method, in extraction and detection of urinary morphine. Fifty-eight urine samples, primarily identified as mor- phine-positive samples by a strip test, 'were re-screened by LLE-TLC and SPE-HPTLC. The results of LLE-TLC and SPE-HPTLC were then compared with each other. The results showed that the SPE-HPTLC detected 74% of total samples as morphine-positive samples whereas the LLE-TLC detected 48% of the same samples. We further discussed the effect of codeine abuse on TLC analysis of urinary morphine. Regarding the importance of morphine detection in urine, the present combined SPE-HPTLC method is suggested as a replacement method for detection of urinary morphine by many reference laboratories. 展开更多
关键词 morphine detection liquid-liquid extraction thin-layer chromatography solid-phase extraction highperformance thin layer chromatography
下载PDF
Early changes to dry eye and ocular surface after smallincision lenticule extraction for myopia 被引量:3
20
作者 Pei-Jin Qiu Ya-Bo Yang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第4期575-579,共5页
AIM: To investigate the early changes in dry eye symptoms, tear function and ocular surface following small-incision lenticule extraction(SMILE) for myopia.·METHODS: Ninety-seven consecutive patients(193 eye... AIM: To investigate the early changes in dry eye symptoms, tear function and ocular surface following small-incision lenticule extraction(SMILE) for myopia.·METHODS: Ninety-seven consecutive patients(193 eyes)who underwent SMILE for myopia were observed in this longitudinal and retrospective study. Parameters evaluated included: subjective dry eye symptoms(dryness, foreign body sensation and photophobia), tear film breakup time(TBUT), Schirmer Ⅰ test without anesthesia(S Ⅰ T), tear meniscus height(TMH) and corneal fluorescein staining. Each parameter was evaluated before, and subsequently at 1d, 1wk, 1 and3 mo after surgery.·RESULTS: Compared with preoperative data, dryness was noted to be significantly increased at 1wk and 1mo postoperatively(P 〈0.01). Symptoms of photophobia and foreign body sensation demonstrated significant differences at 1d and 1wk as compared with preoperative scores respectively(P 〈0.01). These values were decreased at 1 and 3mo post-surgery(P 〉0.05).Conversely the corneal staining scores were higher than the preoperative data at 1d, 1wk and 1mo(P 〈0.01), but were close to the preoperative level at 3mo postoperatively. There was a significant decrease in TMH at 1wk and 1mo(P 〈0.01), but the value was close to the preoperative level at 3mo postoperatively(P =0.16). The examination outcomes of S Ⅰ T were significantly increased at 1d then reduced at 1wk after surgery(P 〈0.01). Each value subsequently returned to the baseline value at 1 and 3mo(P 〉0.05). TBUT was significantly decreased at all postoperative time points(P 〈0.01).· CONCLUSION: SMILE resulted in mild dry eye symptoms, tear film instability and ocular surface damages; however, these complications can recover in a short period of time. 展开更多
关键词 dry eye myopia ocular surface small incision lenticule extraction
下载PDF
上一页 1 2 66 下一页 到第
使用帮助 返回顶部