In this paper, a synthetic mathematical model of load flow for flexible AC transmission systems (FACTS) with unified power flow controller (UPFC) is presented based on the analysis of basic principle and operation sta...In this paper, a synthetic mathematical model of load flow for flexible AC transmission systems (FACTS) with unified power flow controller (UPFC) is presented based on the analysis of basic principle and operation state of UPFC. The model can use the fast P Q decoupled load flow method. Examples of test systems show that the proposed model and method have good convergence. An effective tool is provided by the load flow computer program to analyze the load flow and initial valve calculation of the dynamic state of FACTS.展开更多
In this paper, we use the method of mixed-type series to derive the analytical solutions of cylindrical shell, which is simply supported along the transverse edges and subjected to the local vertical loads, and give t...In this paper, we use the method of mixed-type series to derive the analytical solutions of cylindrical shell, which is simply supported along the transverse edges and subjected to the local vertical loads, and give the analytical expressions of the solutions for this kind of shell under five types of local vertical loading. A numerical example for a cylindrical shell roof, which is simply supported along the trans verse edges and is free along the longitudinal edges, is given in this paper and from the calculated results it may he seen that the convergence of the solutions is considerably satisfactory. Using the solutions of this paper, we can deal with some practical problems of underground structure.展开更多
Two calculation modes for the effect of external load on slope stability, i.e., mode I in which the external load is thought to act on slope surface, and mode II in which the external load is thought to act on slip su...Two calculation modes for the effect of external load on slope stability, i.e., mode I in which the external load is thought to act on slope surface, and mode II in which the external load is thought to act on slip surface along the force action line, were considered. Meanwhile, four basic distribution patterns of external load were used, of which complex external loads could be composed. In analysis process, several limit equilibrium methods, such as Swedish method, simplified Bishop method, simplified Janbu method, Spencer method, Morgenstern-Price(M-P) method, Sarma method, and unbalanced thrust method, were also adopted to contrast their differences in slope stability under the external load. According to parametric analysis, some conclusions can be obtained as follows:(1) The external load, with the large magnitude, small inclination angle, and acting position close to the slope toe,has more positive effect on slope stability;(2) The results calculated using modes I and II of external load are similar, indicating that the calculation mode of external load has little influence on slope stability;(3) If different patterns of external loads are equivalent to each other, their slope stability under these external loads are the same, and if not, the external load leads to the better slope stability,as action position of the resultant force for external load is closer to the lower sliding point of slip surface.展开更多
In the calculation of submarine air conditioning load of the early stage, the obtained heat is regarded as cooling load. The confusion of the two words causing the cooling load figured out is abnormally high, and the ...In the calculation of submarine air conditioning load of the early stage, the obtained heat is regarded as cooling load. The confusion of the two words causing the cooling load figured out is abnormally high, and the change of air conditioning cooling load can not be indicated. In accordance with submarine structure and heat transfer characteristics of its inner components, Laplace transformation to heat conduction differential equation of cylinder wall is carried out. The dynamic calculation of submarine conditioning load based on this model is also conducted, and the results of calculation are compared with those of static cooling load calculation. It is concluded that the dynamic cooling load calculation methods can illustrate the change of submarine air conditioning cooling load more accurate than the static one.展开更多
The concentration of runoff depends upon that of soil loss and the latter is assumed to be linear to the value of EI that equals the product of total storm energy E times the maximum 30-min intensity I 30 for a giv...The concentration of runoff depends upon that of soil loss and the latter is assumed to be linear to the value of EI that equals the product of total storm energy E times the maximum 30-min intensity I 30 for a given rainstorm. Usually, the maximum accumulative amount of rain for a rainstorm might bring on the maximum amount of runoff, but it does not equal the maximum erosion and not always lead the maximum concentration. Thus, the average concentration weighted by amount of runoff is somewhat unreasonable. An improvement for the calculation method of non-point source pollution load put forward by professor Li Huaien is proposed. In replacement of the weight of runoff, EI value of a single rainstorm is introduced as a new weight. An example of Fujing River watershed shows that its application is effective.展开更多
There has been a growing trend in the development of offshore deep-water ports in China. For such deep sea projects, all-vertical-piled wharves are suitable structures and generally located in open waters, greatly aff...There has been a growing trend in the development of offshore deep-water ports in China. For such deep sea projects, all-vertical-piled wharves are suitable structures and generally located in open waters, greatly affected by wave action. Currently, no systematic studies or simplified numerical methods are available for deriving the dynamic characteristics and dynamic responses of all-vertical-piled wharves under wave cyclic loads. In this article, we compare the dynamic characteristics of an all-vertical-piled wharf with those of a traditional inshore high-piled wharf through numerical analysis; our research reveals that the vibration period of an all-vertical-piled wharf under cyclic loading is longer than that of an inshore high-piled wharf and is much closer to the period of the loading wave. Therefore, dynamic calculation and analysis should be conducted when designing and calculating the characteristics of an all-vertical-piled wharf. We establish a dynamic finite element model to examine the dynamic response of an all-vertical-piled wharf under wave cyclic loads and compare the results with those under wave equivalent static load; the comparison indicates that dynamic amplification of the structure is evident when the wave dynamic load effect is taken into account. Furthermore, a simplified dynamic numerical method for calculating the dynamic response of an all-vertical-piled wharf is established based on the P-Y curve. Compared with finite element analysis, the simplified method is more convenient to use and applicable to large structural deformation while considering the soil non-linearity. We confirmed that the simplified method has acceptable accuracy and can be used in engineering applications.展开更多
This paper presents practical distribution system equipment models such as various distributed generators, voltage regulators, and loads for fast three phase unbalanced load flow calculation in distribution systems. T...This paper presents practical distribution system equipment models such as various distributed generators, voltage regulators, and loads for fast three phase unbalanced load flow calculation in distribution systems. The method can calculate voltage and current of distribution systems, in which distributed generators are introduced. The calculation time of the proposed method is about 40 times faster than that of the Newton-Raphson method. Moreover, an introduction effect evaluation tool for distributed generators using the proposed three phase unbalanced load flow calculation is presented. It provides various functions such as a power system network diagram creation function and a voltage profile chart display function. Therefore, the introduction effect evaluation of distributed generators in distribution systems can be evaluated quite easily.展开更多
文摘In this paper, a synthetic mathematical model of load flow for flexible AC transmission systems (FACTS) with unified power flow controller (UPFC) is presented based on the analysis of basic principle and operation state of UPFC. The model can use the fast P Q decoupled load flow method. Examples of test systems show that the proposed model and method have good convergence. An effective tool is provided by the load flow computer program to analyze the load flow and initial valve calculation of the dynamic state of FACTS.
基金Project Supported by the National Natural Science Foundation of Chinaby Scientific and Technical Fund of Ministry of UrbanRural Construction and Environmental Protection
文摘In this paper, we use the method of mixed-type series to derive the analytical solutions of cylindrical shell, which is simply supported along the transverse edges and subjected to the local vertical loads, and give the analytical expressions of the solutions for this kind of shell under five types of local vertical loading. A numerical example for a cylindrical shell roof, which is simply supported along the trans verse edges and is free along the longitudinal edges, is given in this paper and from the calculated results it may he seen that the convergence of the solutions is considerably satisfactory. Using the solutions of this paper, we can deal with some practical problems of underground structure.
基金Project(2015M580702)supported by the China Postdoctoral Science FoundationProject(51608541)supported by the National Natural Science Foundation of ChinaProject(2014122006)supported by the Guizhou Provincial Department of Transportation Foundation,China
文摘Two calculation modes for the effect of external load on slope stability, i.e., mode I in which the external load is thought to act on slope surface, and mode II in which the external load is thought to act on slip surface along the force action line, were considered. Meanwhile, four basic distribution patterns of external load were used, of which complex external loads could be composed. In analysis process, several limit equilibrium methods, such as Swedish method, simplified Bishop method, simplified Janbu method, Spencer method, Morgenstern-Price(M-P) method, Sarma method, and unbalanced thrust method, were also adopted to contrast their differences in slope stability under the external load. According to parametric analysis, some conclusions can be obtained as follows:(1) The external load, with the large magnitude, small inclination angle, and acting position close to the slope toe,has more positive effect on slope stability;(2) The results calculated using modes I and II of external load are similar, indicating that the calculation mode of external load has little influence on slope stability;(3) If different patterns of external loads are equivalent to each other, their slope stability under these external loads are the same, and if not, the external load leads to the better slope stability,as action position of the resultant force for external load is closer to the lower sliding point of slip surface.
文摘In the calculation of submarine air conditioning load of the early stage, the obtained heat is regarded as cooling load. The confusion of the two words causing the cooling load figured out is abnormally high, and the change of air conditioning cooling load can not be indicated. In accordance with submarine structure and heat transfer characteristics of its inner components, Laplace transformation to heat conduction differential equation of cylinder wall is carried out. The dynamic calculation of submarine conditioning load based on this model is also conducted, and the results of calculation are compared with those of static cooling load calculation. It is concluded that the dynamic cooling load calculation methods can illustrate the change of submarine air conditioning cooling load more accurate than the static one.
基金FoundationofSichuanScienceandTech nologyCommittee (No .0 1SG4 7 0 2 )
文摘The concentration of runoff depends upon that of soil loss and the latter is assumed to be linear to the value of EI that equals the product of total storm energy E times the maximum 30-min intensity I 30 for a given rainstorm. Usually, the maximum accumulative amount of rain for a rainstorm might bring on the maximum amount of runoff, but it does not equal the maximum erosion and not always lead the maximum concentration. Thus, the average concentration weighted by amount of runoff is somewhat unreasonable. An improvement for the calculation method of non-point source pollution load put forward by professor Li Huaien is proposed. In replacement of the weight of runoff, EI value of a single rainstorm is introduced as a new weight. An example of Fujing River watershed shows that its application is effective.
基金financially supported by the Major Science and Technology Project of MOT,China(Grant Nos.2013 328 224 070 and 2014 328 224 040)the National Natural Science Foundation of China(Grant No.51409134)
文摘There has been a growing trend in the development of offshore deep-water ports in China. For such deep sea projects, all-vertical-piled wharves are suitable structures and generally located in open waters, greatly affected by wave action. Currently, no systematic studies or simplified numerical methods are available for deriving the dynamic characteristics and dynamic responses of all-vertical-piled wharves under wave cyclic loads. In this article, we compare the dynamic characteristics of an all-vertical-piled wharf with those of a traditional inshore high-piled wharf through numerical analysis; our research reveals that the vibration period of an all-vertical-piled wharf under cyclic loading is longer than that of an inshore high-piled wharf and is much closer to the period of the loading wave. Therefore, dynamic calculation and analysis should be conducted when designing and calculating the characteristics of an all-vertical-piled wharf. We establish a dynamic finite element model to examine the dynamic response of an all-vertical-piled wharf under wave cyclic loads and compare the results with those under wave equivalent static load; the comparison indicates that dynamic amplification of the structure is evident when the wave dynamic load effect is taken into account. Furthermore, a simplified dynamic numerical method for calculating the dynamic response of an all-vertical-piled wharf is established based on the P-Y curve. Compared with finite element analysis, the simplified method is more convenient to use and applicable to large structural deformation while considering the soil non-linearity. We confirmed that the simplified method has acceptable accuracy and can be used in engineering applications.
文摘This paper presents practical distribution system equipment models such as various distributed generators, voltage regulators, and loads for fast three phase unbalanced load flow calculation in distribution systems. The method can calculate voltage and current of distribution systems, in which distributed generators are introduced. The calculation time of the proposed method is about 40 times faster than that of the Newton-Raphson method. Moreover, an introduction effect evaluation tool for distributed generators using the proposed three phase unbalanced load flow calculation is presented. It provides various functions such as a power system network diagram creation function and a voltage profile chart display function. Therefore, the introduction effect evaluation of distributed generators in distribution systems can be evaluated quite easily.