期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Local failure mechanism of sand-blocking fence in latticed dune along desert roads
1
作者 LI Liangying LV Lele +3 位作者 LI Qi WANG Zhenqiang YANG Youhai YIN Wenhua 《Journal of Mountain Science》 SCIE CSCD 2024年第2期526-537,共12页
The latticed dunes in the Tengger Desert are widely distributed,and the sand-blocking fence placed here are highly susceptible to local failure due to complex wind-sand activities,posing a serious threat to the safe o... The latticed dunes in the Tengger Desert are widely distributed,and the sand-blocking fence placed here are highly susceptible to local failure due to complex wind-sand activities,posing a serious threat to the safe operation of the highway.To explore the local failure mechanism of sand-blocking fence in the latticed dune area,the local failure of sand-blocking fence in the latticed dune areas along the Wuhai-Maqin Highway in China was observed.Taking the first main ridge of the latticed dune as the placement location,the structure of the wind-sand flow field of sand-blocking fence placed at top,the bottom and the middle of windward slope was analyzed by Computational Fluid Dynamics(CFD).The results show that when placed at top of the first main ridge,the wind speed near the sand-blocking fence is the highest,up to 15.23 m/s.Therefore,the wind load strength on the sand barrier is correspondingly larger,up to 232.61 N∙m-2.As the strength of material continues to decrease,the nylon net is prone to breakage.The roots of the angle steel posts are susceptible to hollowing by vortex action,which can cause sand-blocking fence to fall over in strong wind conditions.When placed at the bottom of windward slope,wind speed drop near sand-blocking fence is greatest,with the decrease of 12.48-14.32 m/s compared to the original wind speed.This is highly likely to lead to large-scale deposition of sand particles and burial of the sand-blocking fence.When placed in the middle of windward slope,sand-blocking fence is subjected to less wind load strength(168.61N∙m-2)and sand particles are mostly deposited at the bottom of windward slope,with only a small amount of sand accumulating at the root of sand-blocking fence.Based on field observations and numerical modelling results,when the sand-blocking fence is placed in latticed dune area,it should be placed in the middle of the windward slope of the first main ridge as a matter of priority.Besides the sand-blocking fence should be placed at the top of the first main ridge,and sand fixing measures should be added. 展开更多
关键词 Latticed dune Sand-blocking fence local failure Numerical simulation Desert roads
下载PDF
THREE-DIMENSIONAL CONFORMAL RADIATION THERAPY FOR LOCALLY RECURRENT NASOPHARYNGEAL CARCINOMA
2
作者 郑小康 马骏 +1 位作者 夏云飞 陈龙华 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2001年第3期221-225,共5页
Objective: To investigate the safety and effectiveness of three-dimensional conformal radiation therapy (3-D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: From April 1998 to March 2000, 34 patien... Objective: To investigate the safety and effectiveness of three-dimensional conformal radiation therapy (3-D CRT) for locally recurrent nasopharyngeal carcinoma (NPC). Methods: From April 1998 to March 2000, 34 patients who had undergone previous external beam radiation therapy were retreated with 3-D CRT for locally recurrent NPC (33 poorly differentiated squamous cell carcinomas, 1 adenoma). The patients were re-staged according to Huaqing staging system with the following distribution: T1N0M0 in 5 cases, T2N0M0 in 11 cases, T3N0M0 in 12 cases, T4N0M0 in 6 cases. The maximal dimension of the gross tumor volume (GTV) ranged from 1.0 cm to 5.0 cm (median: 2.9 cm). CT simulation and 3-D planning were used to ensure full and conformal coverage of the planning target volume (PTV) by treated volume, while minimizing the absorbed dose of the adjacent normal tissue. 5–7 static conformal coplanar or noncoplanar portals were delivered for each fraction irradiation. The total dose delivered ranged from 65–70 Gy, with 2.5 Gy per fractionation, one fractionation per day, 5 days a week. Median follow-up time from 3-D CRT was 25 months (range: 12–36 months). Results: Over the follow-up period, local recurrence was observed in 3 patients, regional failure in 3, distant metastasis in 3, and six patients died; 88.2% (30/34) of the patient maintained local control, 82.4% (28/34) survived, and 76.5% (26/34) survived with no evidence of tumor. Acute complications were minor and few. The overall incidence of late complication was 20.6% (7/34), and severe complication was 14.7% (5/34), after re-irradiation with 3-D CRT. Conclusion: 3-D CRT is safety and effectiveness for most of the patients with locally recurrent NPC. Our preliminary results indicate a high local control rate and a low complication rate. The long-term curative effect and sequelae await further study. 展开更多
关键词 Nasopharyngeal neoplasms RADIOTHERAPY local failure 3-D conformal
下载PDF
Field investigation on severely damaged aseismic buildings in 2014 Ludian earthquake 被引量:13
3
作者 Lin Xuchuan Zhang Haoyu +2 位作者 Chen Hongfu Chen Hao Lin Junqi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期169-176,共8页
The 2014 magnitude 6.5 Ludian earthquake caused a death toll of 617, many landslides and tens of thousands of collapsed buildings. A field investigation to evaluate the damage to buildings was carried out immediately ... The 2014 magnitude 6.5 Ludian earthquake caused a death toll of 617, many landslides and tens of thousands of collapsed buildings. A field investigation to evaluate the damage to buildings was carried out immediately after the occurrence of the earthquake. Severely damaged aseismic buildings, which were basically observed in the downtown of Longtoushan Town, were carefully examined one by one with the aim to improve design codes. This paper summarizes the damage observed to the investigated aseismic buildings in both the structural and local levels. A common failure mode was observed that most of the aseismic buildings, such as RC frame structures and confined masonry structures, were similarly destroyed by severe damage or complete collapse of the first story. The related strong ground motion, which was recorded at the nearby station, had a short duration of less than 20 s but a very large PGA up to 1.0 g. The RC frames based on the new design codes still failed to achieve the design target for "strong column, weak beam". Typical local failure details, which were related to the interaction between RC columns and infill walls and between constructional columns and masonry walls, are summarized with preliminary analyses. 展开更多
关键词 Ludian earthquake field investigation aseismic buildings structural collapse local failure
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部