期刊文献+
共找到2,087篇文章
< 1 2 105 >
每页显示 20 50 100
Joint observation of long period tremor signals with broadband seismometer,tiltmeter and gravimeter 被引量:25
1
作者 张雁滨 蒋骏 +2 位作者 廖盈春 李胜乐 钟铁涛 《地震学报》 CSCD 北大核心 2008年第6期626-633,共8页
We report here the observation result of joint observation of long period tremor signals with broadband seismome-ter,tiltmeter and gravimeter at the HUST(Huazhong University of Science and Technology)station.The obser... We report here the observation result of joint observation of long period tremor signals with broadband seismome-ter,tiltmeter and gravimeter at the HUST(Huazhong University of Science and Technology)station.The observed data were compared and analyzed.Since 2005,the several tens of abnormal tremor signals which are weak,com-plex and duration of 2 to 3 days have been synchronously recorded by the different instruments.The tremor signals have the periodic domain in the range of 3 to 5 minutes,20 to 30 minutes and even more than 1 hour.The observa-tion shows such tremors are a physical existence.The analysis indicates that a part of the tremors caused by the typhoon from the western Pacific Ocean.These tremors have a close relationship with wind velocity of typhoon and distance between the typhoon center and the station.Except these,the cause of others is still unclear. 展开更多
关键词 宽频地震观测 重力观测 倾斜观测 长周期信号 震颤 台风
下载PDF
Microstructure characterization and corrosion behavior of Mg-Y-Zn alloys with different long period stacking ordered structures 被引量:15
2
作者 Lisha Wang Jinghua Jiang +2 位作者 Huan Liu Bassiouny Saleh Aibin Ma 《Journal of Magnesium and Alloys》 SCIE EI CAS 2020年第4期1208-1220,共13页
Mg-Y-Zn alloys with long period stacking ordered(LPSO)structure have received much attention recently and exhibit great potential in applications such as automotive,aerospace and in bio-medical fields.This paper aimed... Mg-Y-Zn alloys with long period stacking ordered(LPSO)structure have received much attention recently and exhibit great potential in applications such as automotive,aerospace and in bio-medical fields.This paper aimed to investigate the effect of different phase constitution of LPSO structures on corrosion rate of bio-medical Mg-Y-Zn alloys.The results showed that as-cast Mg98.5Y1Zn0.5 alloys containing only 18R structure exhibited the highest corrosion resistance with the corrosion rate of 2.78 mm/year.The precipitation of 14H lamellas within a-Mg grains during solid solution treatment introduced the crystallographic orientation corrosion by accelerating micro-galvanic corrosion.The increase of 18R/14H interfaces deteriorated the corrosion resistance,and the grain boundaries also suffered from severe electrochemical dissolution.This work suggested that Mg-Y-Zn alloys with single LPSO structure(either 18R or 14H)exhibited better corrosion resistance than alloys with co-existence 18R and I4H LPSO structures. 展开更多
关键词 Corrosion behavior long period stacking ordered phase Magnesium alloys Solution treatment Bio-materials
下载PDF
Recent developments on corrosion behaviors of Mg alloys with stacking fault or long period stacking ordered structures 被引量:7
3
作者 Yujin Nie Jianwei Dai +1 位作者 Xuan Li Xiaobo Zhang 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2021年第4期1124-1148,共25页
Corrosion is one of the most drawbacks which restricts the wide applications of Mg alloys.In the last decade,the corrosion behaviors of Mg alloys with stacking fault(SF)and/or long period stacking ordered(LPSO)structu... Corrosion is one of the most drawbacks which restricts the wide applications of Mg alloys.In the last decade,the corrosion behaviors of Mg alloys with stacking fault(SF)and/or long period stacking ordered(LPSO)structures have obtained increasing attention.However,the corrosion mechanism of the SF–or LPSO–containing Mg alloys has not been well illustrated and even reverse results have been reported.In this paper,we have reviewed recent reports on corrosion behaviors of SF–or LPSO–containing Mg alloys to better clarify and understand the significance and mechanism.Moreover,some deficiencies are presented and advises are proposed for the development of corrosion resistant Mg alloys with SF or LPSO structures. 展开更多
关键词 Magnesium alloys Corrosion behavior Stacking fault long period stacking ordered
下载PDF
Effect of Li on formation of long period stacking ordered phases and mechanical properties of Mg-Gd-Zn alloy 被引量:2
4
作者 Li-yun Wei Jin-shan Zhang +3 位作者 Wei Liu Chun-xiang Xu Zhi-yong You Kai-bo Nie 《China Foundry》 SCIE 2016年第4期256-261,共6页
Alloys with composition of Mg_(96-x)Gd_3Zn_1Li_x(at.%)(x=0, 2, 4, and 6) were prepared by conventional casting. The microstructures of these alloys under as-cast and solid-solution conditions have been observed, and t... Alloys with composition of Mg_(96-x)Gd_3Zn_1Li_x(at.%)(x=0, 2, 4, and 6) were prepared by conventional casting. The microstructures of these alloys under as-cast and solid-solution conditions have been observed, and the mechanical properties were investigated. The results showed that Li is an effective element to refine the grains and break the eutectic networks in as-cast MgGd_3Zn_1 alloy. During solid solution treatment, these broken eutectic networks are spheroidized and highly dispersed. In addition, plentiful lamellar long period stacking ordered(LPSO) phases are precipitated in an α-Mg matrix when the Li addition is not more than 4%. Solid-solution treated Mg_(92)Gd_3Zn_1Li_4 alloy exhibits an optimal ultimate tensile strength(UTS) of 226 MPa and elongation of 5.8%. The strength of MgGd_3Zn_1 alloy is improved significantly, meanwhile, the toughness is apparently increased. 展开更多
关键词 Mg-Gd-Zn alloys LI second phase long period stacking ordered phase comprehensive properties
下载PDF
Effect of long period stacking ordered phase on damping capacities of as-cast Mg-Zn-Y alloys 被引量:2
5
作者 LU Ruo-peng DING Zhi-bing +1 位作者 WNANG Jing-feng ZHAO Yu-hong 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2017年第3期283-288,共6页
The microstructure and damping capacities of MgZnxYi.33x(x=l-4at.%)alloys were discussed and researched.The main phase composition of the alloys consists of a_Mg and long-period stacking ordered(LPSO)phase.Due to incr... The microstructure and damping capacities of MgZnxYi.33x(x=l-4at.%)alloys were discussed and researched.The main phase composition of the alloys consists of a_Mg and long-period stacking ordered(LPSO)phase.Due to increasedLPSO phase,grain size was refined.LPSO phase was advantageous to the damping properties of the Mg-Zn-Y alloys.Mg-7%Zn-12.8%Y has the highest damping capacity up to0.04.Due to stacking fault probability,the LPSO phase in the Mg-Zn-Yalloys could be new damping source to dissipate energy so as to contribute to the improvement of damping capacities. 展开更多
关键词 magnesium alloys DAMPING microstructure long period stacking ordered (LPSO) phase
下载PDF
Dilute long period stacking/order(LPSO)-variant phases along the composition gradient in a Mg-Ho-Cu alloy 被引量:2
6
作者 Kai Guan Daisuke Egusa Eiji Abe 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2022年第6期1573-1580,共8页
We have systematically investigated the microstructures of as-cast Mg_(97.49)Ho_(1.99)Cu_(0.43)Zr_(0.09)alloy by atomic resolution high-angle annular dark field scanning transmission electron microscopy(HAADF-STEM), r... We have systematically investigated the microstructures of as-cast Mg_(97.49)Ho_(1.99)Cu_(0.43)Zr_(0.09)alloy by atomic resolution high-angle annular dark field scanning transmission electron microscopy(HAADF-STEM), revealing the coexistence of 18R, 14H and 24R long period stacking/order(LPSO) phases with fully coherent interfaces along step-like composition gradient in a blocky intermetallic compound distributed at grain boundary. The short-range order(SRO) L1_(2)-type Cu_(6)Ho_(8)clusters embedded across AB’C’A-stacking fault layers are directly revealed at atomic scale. Importantly, the order degree of SRO clusters in the present dilute alloy is significant lower than previous 6M and 7M in-plane order reported in ternary Mg-TM(transition metal)-RE(rare earth) alloys, which can be well matched by 9M in-plane order. This directly demonstrates that SRO in-plane L1_(2)-type clusters can be expanded into more dilute composition regions bounded along the definite TM/RE ratio of 3/4. In addition, the estimated chemical compositions of solute enriched stacking fault(SESF) in all LPSO variants are almost identical with the ideal SESF composition of 9M in-plane order, regardless of the type of LPSO phases. The results further support the viewpoint that robust L1_(2)-type TM_(6)RE_(8)clusters play an important role in governing LPSO phase formation. 展开更多
关键词 Magnesium alloys long period stacking/order(LPSO)phases Short-range order(SRO)clusters High-angle annular dark field scanning transmission electron microscopy(HAADF-STEM)
下载PDF
High Sensitive Long Period Fiber Grating Sensor for Detection of Nitrite 被引量:1
7
作者 QIAN Ying YU Yong-sen +4 位作者 LI Qiu-shun WU Si-zhu ZHAO Kai-jun YANG Bai-liang ZHANG Yu-shu 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2009年第5期624-627,共4页
A high sensitive long period fiber grating(LPFG) sensor for the detection of nitrite is proposed, which is realized by coating multiple poly(sodium 4-styrensulfonate)(PSS) and poly(diallyldimethylammonium) chl... A high sensitive long period fiber grating(LPFG) sensor for the detection of nitrite is proposed, which is realized by coating multiple poly(sodium 4-styrensulfonate)(PSS) and poly(diallyldimethylammonium) chloride (PDDA) layers on the fiber grating surface. The sensitivity of this LPFG sensor is maximum when the number of assembled layers is 70. Under this condition, a nitrite concentration of 3×10^-3 mol/L, which is lower than the National Food Additive Standard, 4.2×10^-3 mol/L, can be distinguished. The sensitivity is further increased by 30% when nitrite was determined in the sucrose solution with a concentration of 65%, which provides a new solution for the best refraction index approaching matched index of the fiber cladding. Compared with chemical methods, this nitrite detection technology offers some advantages, such as high accuracy, non toxicity, high speed, low cost, without chemical reagent, and is suitable for foodstuff security detection. 展开更多
关键词 long period fiber gratings Refractive index sensor Detection of nitrite
下载PDF
Microstructure and mechanical properties of a compound reinforced Mg95Y2.5Zn2.5 alloy with long period stacking ordered phase and W phase 被引量:1
8
作者 Shou-zhong Wu Jin-shan Zhang +3 位作者 Chun-xiang Xu Kai-bo Nie Xiao-feng Niu Zhi-yong You 《China Foundry》 SCIE 2017年第1期34-38,共5页
The microstructure evolution of Mg100-2xYxZnx (x=2, 2.5, 3, 3.5) alloys was investigated. Results show that the Mg100-2xYxZnx alloys are composed of a-Mg, long period stacking ordered (LPSO) phase and eutectic str... The microstructure evolution of Mg100-2xYxZnx (x=2, 2.5, 3, 3.5) alloys was investigated. Results show that the Mg100-2xYxZnx alloys are composed of a-Mg, long period stacking ordered (LPSO) phase and eutectic structure phase (W phase), and the Mg95Y2.5Zn2.5 alloy has the best comprehensive mechanical properties. Subsequently, the microstructure evolution of the optimized alloy Mg95Y2.5Zn2.5 during solidification and heat treatment processes was analyzed and discussed by means of OM, SEM, TEM, XRD and DTA. After heat treatment, the lamellar phase 14H-LPSO precipitated in a-Mg and W phase transforms into particle phase (MgyZn2). Due to the compound reinforcement effect of the particle phase and LPSO phase (18R+14H), the mechanical properties of the alloy are enhanced. The tensile strength and elongation of the Mg95Y2.5Zn2.5 alloy is improved by 9.1% and 31.3% to 215 MPa and 10.5%, respectively, after solid-solution treatment. 展开更多
关键词 magnesium alloys Mg95Y2.5Zn2.5 alloy long period stacking ordered (LPSO) W phase compound reinforcement
下载PDF
Numerical Analysis of Fiber Bragg Grating and Long Period Fiber Grating Undergoing Linear and Quadratic Temperature Change
9
作者 袁银权 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2009年第6期952-955,共4页
The coupled-mode equations for fiber Bragg grating (FBG) and long period fiber grating (LPFG) undergoing linear and quadratic temperature change were given. The effects of temperature gradient and quadratic temper... The coupled-mode equations for fiber Bragg grating (FBG) and long period fiber grating (LPFG) undergoing linear and quadratic temperature change were given. The effects of temperature gradient and quadratic temperature change on the reflectivity spectrum of fiber Braggs grating and the transmission spectrum of long period fiber grating were investigated using the numerical simulation, and the dependence relationships of the central wavelength shift, the full-width-athalf-maximum, and the peak intensity upon temperature gradient were also obtained. These relationships may be used to design a novel fiber optical sensor which can simultaneously measure the temperature and temperature gradient. 展开更多
关键词 temperature gradient fiber Bragg grating long period fiber grating coupled- mode theory simulation
下载PDF
Numerical and experimental analysis of long period gratings in wavelength scale elliptical microfibers
10
作者 金娃 毕卫红 付广伟 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第10期147-151,共5页
We report the fabrication of long-period gratings (LPGs) in elliptical microfibers with femtosecond laser. Based on the numerical analysis of the modes and the mode coupling condition of elliptical microfibers, an L... We report the fabrication of long-period gratings (LPGs) in elliptical microfibers with femtosecond laser. Based on the numerical analysis of the modes and the mode coupling condition of elliptical microfibers, an LPG is fabricated with a very short pitch of 10 μm by periodically modifying the fiber surface, which demonstrates very strong polarization-dependent resonances, a very low temperature sensitivity of a few picometers in air, and high temperature sensitivity of -1.62 nm/℃ in refractive index oil. 展开更多
关键词 elliptical microfiber long period grating femtosecond laser temperature sensitivity
下载PDF
Characteristics of long period microtremor and validation of microtremor array measurements in inland areas of China
11
作者 CHE Ai-lan ZHANG Teng-yu FENG Shao-kong 《Journal of Mountain Science》 SCIE CSCD 2016年第11期1910-1922,共13页
To study the characteristics of long period microtremor and applicability of microtremor survey,we have made microtremor observations using long period seismometers of the China's mainland from coastal cities like... To study the characteristics of long period microtremor and applicability of microtremor survey,we have made microtremor observations using long period seismometers of the China's mainland from coastal cities like Shanghai and Tianjin through Beijing,Xi'an,to the far inland cities of Lanzhou and Tianshui.The observation shows that the level of power spectrum of long period microtremors reduced rapidly from the coast to the inland area.However,the energy of long period microtremors in Beijing,Xi'an,Lanzhou and Tianshui area are only approximately ten-thousandth to thousandth of that in Shanghai.Aiming at the complexity of the underground structure in the far inland,a series of underground structure models with different distributions were assessed using three-dimensional,dynamic finite element method(FEM) analyses.The results were used to evaluate microtremor survey methods and their limitations with regard to aggregate variability and thickness determinations.Multiple-wave reflections between layers with the change of underground structure distribution occurred,which have significant effect on the performance of the different field approaches.Information over a broad spectrum from which velocity-depth profiles were produced via inversion approaches.Neither the thickness nor the shear waveVelocity V of the subsurface layer inversion results appeared over a large evaluation with increasing slope angle.In particular,when the angle of the model reached 45°,it could not be accurately evaluated using one-dimensional inversion methods.Finally,the array microtremor survey(AMS) was carried out in Shanghai City,China.Although AMS techniques do not have the layer sensitivity or accuracy(velocity and layer thickness) of borehole techniques,the obtained shear wave velocity structure is especially useful for earthquake disaster prevention and seismic analysis. 展开更多
关键词 long period microtremor Array Microtremor survey Power spectrum INVERSION S-wave velocity structure
下载PDF
Numerical Simulation on Broad-band Er-doped Superfluorescent Fiber Source Filter Using Long Period Chirped Fiber Grating
12
作者 ZHAO Shu-ping WANG Pin-hong +3 位作者 ZHANG Xiao-xia FANG Xing HE Xu-yi XING Zi-bin 《Semiconductor Photonics and Technology》 CAS 2008年第1期28-31,共4页
Given is an analysis of broad-band Er-doped superfluorescent fiber source(EDSFS)filter using long period chirped fiber grating by transmission matrix method.For our EDSFS attenuated amplitude demand and the flattened ... Given is an analysis of broad-band Er-doped superfluorescent fiber source(EDSFS)filter using long period chirped fiber grating by transmission matrix method.For our EDSFS attenuated amplitude demand and the flattened wavelength range demand,proposed are the key factors of designing such filters of high performances.The simulation result demonstrates that such type filters have an enough attenuation to flatten the dramatic increase in output amplified spontaneous emission(ASE)in the wavelength range of 1529nm^1535nm by choosing conformable fiber filter parameters such as chirped degree,original period,induced index change,length of the fiber filter,and then broad-band EDSFS could be achieved. 展开更多
关键词 Er-doped superfluorescent fiber source(EDSFS) numerical simulation long period chirped fibergrating
下载PDF
Comparison of Design Response Spectrum for Long Period Structures Based on Scenario Earthquakes
13
作者 Xu Dandan Lv Yuejun +1 位作者 Chen Yang Pan Long 《Earthquake Research in China》 2014年第3期403-412,共10页
Two kinds of determining methods for scenario earthquakes are presented in this paper,namely the weighted average method and maximum probability method. This paper briefly introduces the two methods,then taking a high... Two kinds of determining methods for scenario earthquakes are presented in this paper,namely the weighted average method and maximum probability method. This paper briefly introduces the two methods,then taking a high-rise building in the Yantai area as a case study,we use the weighted average method and maximum probability method to realize seismic hazard analysis, determine earthquake magnitude, the epicenter and specific space position,and then give two response spectrums of the two methods. By comparing the differences of response spectrums between the two methods,we find that the weighted average method is more suitable for long period structures,while considering long period safety. The maximum probability method is more suitable for short period structures. It is reasonable to choose a corresponding different method when the structures have different natural vibration periods. 展开更多
关键词 long period Scenario earthquake Weighted average method Maximumprobability method Response spectrum
下载PDF
Source time functions of the 1999, Jiji (Chi-Chi) earthquake from GDSN long period waveform data using aftershocks as empirical Green's functions 被引量:1
14
作者 许力生 G.Patau 陈运泰 《Acta Seismologica Sinica(English Edition)》 EI CSCD 2002年第2期121-133,共13页
A large earthquake (Mw=7.6) occurred in Jiji (Chi-Chi), Taiwan, China on September 20, 1999, and was followed by many moderate-size shocks in the following days. Two of the largest aftershocks with the magnitudes of M... A large earthquake (Mw=7.6) occurred in Jiji (Chi-Chi), Taiwan, China on September 20, 1999, and was followed by many moderate-size shocks in the following days. Two of the largest aftershocks with the magnitudes of Mw=6.1 and Mw=6.2, respectively, were used as empirical Green's functions (EGFs) to obtain the source time functions (STFs) of the main shock from long-period waveform data of the Global Digital Seismograph Network (GDSN) including IRIS, GEOSCOPE and CDSN. For the Mw=6.1 aftershock of September 22, there were 97 pairs of phases clear enough from 78 recordings of 26 stations; for the Mw=6.2 aftershock of September 25, there were 81 pairs of phases clear enough from 72 recordings of 24 stations. For each station, 2 types of STFs were retrieved, which are called P-STF and S-STF due to being from P and S phases, respectively. Totally, 178 STF individuals were obtained for source-process analysis of the main shock. It was noticed that, in general, STFs from most of the stations had similarities except that those in special azimuths looked different or odd due to the mechanism difference between the main shock and the aftershocks; and in detail, the shapes of the STFs varied with azimuth. Both of them reflected the stability and reliability of the retrieved STFs. The comprehensive analysis of those STFs suggested that this event consisted of two sub-events, the total duration time was about 26 s, and on the average, the second event was about 7 s later than the first one, and the moment-rate amplitude of the first event was about 15% larger than that of the second one. 展开更多
关键词 Jiji (Chi-chi) earthquake long-period waveform source time function
下载PDF
Forecasting High-Frequency Long Memory Series with Long Periods Using the SARFIMA Model
15
作者 Handong Li Xunyu Ye 《Open Journal of Statistics》 2015年第1期66-74,共9页
This paper evaluates the efficiency of the SARFIMA model at forecasting high-frequency long memory series with especially long periods. Three other models, the ARFIMA, ARMA and PAR models, are also included to compare... This paper evaluates the efficiency of the SARFIMA model at forecasting high-frequency long memory series with especially long periods. Three other models, the ARFIMA, ARMA and PAR models, are also included to compare their forecasting performances with that of the SARFIMA model. For the artificial SARFIMA series, if the correct parameters are used for estimating and forecasting, the model performs as well as the other three models. However, if the parameters obtained by the WHI estimation are used, the performance of the SARFIMA model falls far behind that of the other models. For the empirical intraday volume series, the SARFIMA model produces the worst performance of all of the models, and the ARFIMA model performs best. The ARMA and PAR models perform very well both for the artificial series and for the intraday volume series. This result indicates that short memory models are competent in forecasting periodic long memory series. 展开更多
关键词 HIGH-FREQUENCY FINANCIAL SERIES long Memory long periodS SARFIMA MONTE Carlo Simulation Intraday Volume
下载PDF
Review of Turn around Point Long Period Fiber Gratings
16
作者 Monika Gambhir Shilpi Gupta 《Journal of Sensor Technology》 2015年第4期81-89,共9页
Long period fiber gratings are emerging as a potential candidate in the list of surrounding refractive index optical fiber sensors. Their sensitivity can be enhanced greatly if the grating period, fiber dimensions and... Long period fiber gratings are emerging as a potential candidate in the list of surrounding refractive index optical fiber sensors. Their sensitivity can be enhanced greatly if the grating period, fiber dimensions and surrounding refractive index are optimized in a way to operate at a point called turn around point on phase matching curves of these gratings. Turn around point LPFGs are well known for their ultrahigh sensitivity to external parameters. Potential of operating LPFG at or near turn around point has been investigated by many researchers in various applications including physical parameter sensing, adulteration detection, radiation dose, etc. Since TAP LPFGs are in investigation phase therefore a lot of rigorous & efficient work in finding techniques for optimizing their potential as sensor in chemical, biochemical, structural health monitoring is still to be carried out. A brief review of work carried out in this domain till now is presented here and key findings from literature review are highlighted. 展开更多
关键词 LPFG (long period Fiber Grating) TAP (Turn AROUND Point) SRI (Surrounding Refractive Index) LP (Linearly Polarized)
下载PDF
Role of Flexible Macro Fibre Composite (MFC) Actuator on Bragg Wavelength Tuning in Microstructure Polymer Optical Fibre Long Period Grating for Strain Sensing Applications
17
作者 Asok K. Dikshit Akhil Raj V. L. 《Journal of Sensor Technology》 2013年第3期75-83,共9页
The microstructure polymer optical fibre (mPOF) inscribed long period grating (LPG) offers a wide field of application in strain sensors arena within the materials elastic limit. Flexible innovative macro fibre compos... The microstructure polymer optical fibre (mPOF) inscribed long period grating (LPG) offers a wide field of application in strain sensors arena within the materials elastic limit. Flexible innovative macro fibre composite (MFC) actuator generates electromechanical force under DC driving voltage. We propose a novel method for Bragg wavelength blue shifting through stretch tuning of mPOF LPG in axial direction under applied DC voltage on attached MFC with LPG. The grating period of mPOF LPG changes refractive index and causes blue shift of Bragg grating fibre wavelength. The shifting governs on the values of generated electromechanically strain transfer from flexible MFC to mPOF LPG and they have potential applications in strain sensor. 展开更多
关键词 Microstructure POLYMER Optical FIBRE (mPOF) long period Grating (LPG) MACRO FIBRE COMPOSITE (MFC) ACTUATOR Strain Sensing Blue Shifting
下载PDF
On the Validity of the Effective Index Method for Long Period Grating Photonic Crystal Fibers
18
作者 Dhia Khadri Walid Belhadj +2 位作者 Douha Gamra Fathi AbdelMalek Habib Bouchriha 《Materials Sciences and Applications》 2012年第5期310-316,共7页
This paper focuses on the investigation of modal characteristics and sensing properties of long period grating photonic crystal fibers (LPG-PCFs). An improved effective index method is employed with an objective to st... This paper focuses on the investigation of modal characteristics and sensing properties of long period grating photonic crystal fibers (LPG-PCFs). An improved effective index method is employed with an objective to study its limitations for various designs of LPG-PCFs. Results so obtained with the above method are compared with the corresponding values of multiple multipole (MMP) method results which points the range of validity and applicability of the improved effective index method to LPG-PCFs. It is shown that this method is excellent when the surrounding media is assumed to be air. However, it becomes less accurate when the fiber is immersed into a liquid with a refractive index close to that of the cladding. 展开更多
关键词 long period GRATINGS Photonic Crystal Fiber (LPG-PCF) Improved Effective Index MMP CLADDING Modes Sensor Sensitivity
下载PDF
Study on the long period ordered(LPO)phase in the Mg-TM(TM=Cu,Ni,Zn)-Y systems
19
作者 JIANG Min ZHANG Jun-feng LI Hong-xiao HAO Shi-ming 《材料与冶金学报》 CAS 2010年第4期282-284,共3页
下载PDF
Long Period Grating Imprinted on a Flat-Shaped Plastic Optical Fiber for Refractive Index Sensing
20
作者 Yuan LIU Yanfei ZHOU +1 位作者 Haiyang BAO Jie ZHENG 《Photonic Sensors》 SCIE EI CSCD 2023年第4期39-49,共11页
A corrugated surface long period grating(LPG)was fabricated on a flat-shaped plastic optical fiber(POF)as a refractive index(RI)sensor by a simple pressing with the heat pressure and mechanical die press print method.... A corrugated surface long period grating(LPG)was fabricated on a flat-shaped plastic optical fiber(POF)as a refractive index(RI)sensor by a simple pressing with the heat pressure and mechanical die press print method.The light propagation characteristics of an LPG imprinted on a multi-mode POF were analyzed by the method of geometrical optics.Theoretical and experimental results showed that the structural parameters of the sensor affected the RI sensing performance,and the sensor with a thinner flat thickness,a deeper groove depth of the corrugated surface LPG,and a longer LPG exhibited better RI sensing performance.When the POF with a diameter of 1 mm was pressed with the heat pressure to a flat shape with a thickness of 600μm,an LPG with a period of 300μm,a groove depth of 200μm,and a length of 6 cm was fabricated on it,and the RI sensitivity of 1447%/RIU was obtained with a resolution of 5.494×10^(−6) RIU.In addition,the influences of the POF cladding,tilting of LPG,and bending of the sensing structure were investigated.The results demonstrated that after removing the cladding and tilting or bending the LPG,the RI sensing performance was improved.When the LPG imprinted on the flat-shaped POF was bent with a curvature radius of 6/πcm,the highest sensitivity of 6563%/RIU was achieved with a resolution of 2.487×10^(−9) RIU in the RI range of 1.3330–1.4230.The proposed sensor is a low-cost solution for RI measurement with the features of easy fabrication,high sensitivity,and intensity modulation at the visible wavelengths. 展开更多
关键词 Plastic optical fiber fiber optic sensor flat-shaped optical fiber long period grating refractive index sensing
原文传递
上一页 1 2 105 下一页 到第
使用帮助 返回顶部