Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3D...Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3DE in the diagnosis of atrial septal defect (ASD) and its use in the guidance for transcatheter ASD occlusion. Twelve patients with secundum ASD underwent RT-3DE examination and 9 of the 12 were subjected to transcatheter closure of ASD. Stereoscopic vision was generated with a high-performance volume renderer with red-green stereoscopic glasses. S-3DE was compared with standard RT-3D display for the assessment of the shape, size, and the surrounding tis-sues of ASD and for the guidance of ASD occlusion. The appearance rate of coronary sinus and the mean formation time of the IVC, SVC were compared. Our results showed that S-3DE could measure the diameter of ASD accurately and there was no significant difference in the measurements between S-3DE and standard 3D display (2.89±0.73 cm vs 2.85±0.72 cm, P〉0.05; r=0.96, P〈0.05). The appearance of coronary sinus for S-3DE was higher as compared with the standard 3D display (93.3% vs 100%). The mean time of the IVC, SVC for S-3DE monitor was slightly shorter than that of the standard 3D display (11.0±3.8 s vs 10.3±3.6 s, P〉0.05). The mean completion time of interven-tional procedure was shortened with S-3DE display as compared with standard 3D display (17.3±3.1 min vs 23.0±3.9 min, P〈0.05). Stereoscopic three-dimensional echocardiography could improve the visualization of three-dimensional echocardiography, facilitate the identification of the adjacent structures, decrease the time required for interventional manipulation. It may be a feasible, safe, and efficient tool for guiding transcatheter septal occlusion or the surgical interventions.展开更多
针对多视图三维重建任务中点云完整性欠佳的问题,提出一种基于空间传播的多视图深度估计网络(SPMVSNet)。引入空间传播思想用于复杂条件下的稠密点云重建,并分别设计基于空间传播的混合深度假设策略和空间感知优化模块。混合深度假设策...针对多视图三维重建任务中点云完整性欠佳的问题,提出一种基于空间传播的多视图深度估计网络(SPMVSNet)。引入空间传播思想用于复杂条件下的稠密点云重建,并分别设计基于空间传播的混合深度假设策略和空间感知优化模块。混合深度假设策略采用由粗糙到精细的深度推理方式,将深度估计视为多标签分类任务,对正则化概率体执行交叉熵损失以约束代价体,从而避免回归方法过拟合和收敛速度过慢的问题。空间感知优化模块从包含高级语义特征表示的特征图中获得引导,在进行置信度检查后采用卷积空间传播网络,通过构建亲和矩阵来细化最终的深度图。同时,为解决大多数方法存在的对不满足多视图一致性的不可靠区域重建质量较低的问题,进一步结合注意力机制设计具有样本自适应能力的动态特征提取网络,用于增强模型的局部感知能力。实验结果表明,在DTU数据集上,SP-MVSNet的重建完整性相比于CVP-MVSNet提升32.8%,整体质量提升11.4%。在Tanks and Temples基准和Blended MVS数据集上,SP-MVSNet的表现也优于大多数已知方法,取得了良好的三维重建效果。展开更多
文摘Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3DE in the diagnosis of atrial septal defect (ASD) and its use in the guidance for transcatheter ASD occlusion. Twelve patients with secundum ASD underwent RT-3DE examination and 9 of the 12 were subjected to transcatheter closure of ASD. Stereoscopic vision was generated with a high-performance volume renderer with red-green stereoscopic glasses. S-3DE was compared with standard RT-3D display for the assessment of the shape, size, and the surrounding tis-sues of ASD and for the guidance of ASD occlusion. The appearance rate of coronary sinus and the mean formation time of the IVC, SVC were compared. Our results showed that S-3DE could measure the diameter of ASD accurately and there was no significant difference in the measurements between S-3DE and standard 3D display (2.89±0.73 cm vs 2.85±0.72 cm, P〉0.05; r=0.96, P〈0.05). The appearance of coronary sinus for S-3DE was higher as compared with the standard 3D display (93.3% vs 100%). The mean time of the IVC, SVC for S-3DE monitor was slightly shorter than that of the standard 3D display (11.0±3.8 s vs 10.3±3.6 s, P〉0.05). The mean completion time of interven-tional procedure was shortened with S-3DE display as compared with standard 3D display (17.3±3.1 min vs 23.0±3.9 min, P〈0.05). Stereoscopic three-dimensional echocardiography could improve the visualization of three-dimensional echocardiography, facilitate the identification of the adjacent structures, decrease the time required for interventional manipulation. It may be a feasible, safe, and efficient tool for guiding transcatheter septal occlusion or the surgical interventions.
文摘针对多视图三维重建任务中点云完整性欠佳的问题,提出一种基于空间传播的多视图深度估计网络(SPMVSNet)。引入空间传播思想用于复杂条件下的稠密点云重建,并分别设计基于空间传播的混合深度假设策略和空间感知优化模块。混合深度假设策略采用由粗糙到精细的深度推理方式,将深度估计视为多标签分类任务,对正则化概率体执行交叉熵损失以约束代价体,从而避免回归方法过拟合和收敛速度过慢的问题。空间感知优化模块从包含高级语义特征表示的特征图中获得引导,在进行置信度检查后采用卷积空间传播网络,通过构建亲和矩阵来细化最终的深度图。同时,为解决大多数方法存在的对不满足多视图一致性的不可靠区域重建质量较低的问题,进一步结合注意力机制设计具有样本自适应能力的动态特征提取网络,用于增强模型的局部感知能力。实验结果表明,在DTU数据集上,SP-MVSNet的重建完整性相比于CVP-MVSNet提升32.8%,整体质量提升11.4%。在Tanks and Temples基准和Blended MVS数据集上,SP-MVSNet的表现也优于大多数已知方法,取得了良好的三维重建效果。