期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Simulation of Quantum Noise in the Low-Light-Level Imaging System 被引量:3
1
作者 邹正峰 芦汉生 +1 位作者 白廷柱 高稚允 《Journal of Beijing Institute of Technology》 EI CAS 2001年第2期186-190,共5页
A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the... A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the basis of the model created. Three uniform random sequences are built by the linear congruential method, of which two are used to form integer number and decimal fraction parts of the new random sequence respectively and the third to shuffle the new sequence. And then a Gauss sequence is formed out of uniform distribution by a function transforming method. It actualizes the simulation in real time of quantum noise in the low light imaging system, where video flow is extracted in real time, the noise summed up and played back side by side with the original video signs by a simulation software. 展开更多
关键词 SIMULATION quantum noises low light level imaging
下载PDF
Novel Frame Shift and Integral Technique for Enhancing Low-Light-Level Moving Images
2
作者 宋勇 郝群 王涌天 《Journal of Beijing Institute of Technology》 EI CAS 2006年第1期91-96,共6页
A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on differe... A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on difference processing. To obtain spatial relativity, images are shifted according to the motion parameters. As a result, the processing of integral and average can be applied to images that have been shifted. The technique of frame shift and integral that includes the algorithm of motion parameter determination is discussed, experiments with low light level moving image sequences are also described. The experiment results show the effectiveness and the robustness of the parameter determination algorithm, and the improvement in the signal-to-noise ratio (SNR) of low light level moving images. 展开更多
关键词 frame integral low light level image moving image sequence signal-to-noise ratio (SNR)
下载PDF
MTF Measurement of EBCCD Imaging System by Using Super Resolution Technique
3
作者 左昉 高岳 +2 位作者 高稚允 苏美开 周立伟 《Journal of Beijing Institute of Technology》 EI CAS 2003年第2期125-128,共4页
Existing methods of measurement MTF for discrete imaging system are analysed. A slit target is frequently used to measure the MTF for an imaging system. Usually there are four methods to measure the MTF for a discrete... Existing methods of measurement MTF for discrete imaging system are analysed. A slit target is frequently used to measure the MTF for an imaging system. Usually there are four methods to measure the MTF for a discrete imaging system by using a slit. These methods have something imperfect respectively. But for the discrete imaging systems of under sampling it is difficult to reproduce this type of target properly since frequencies above Nyquist are folded into those below Nyquist, resulting in aliasing effect. To tackle the aliasing problem, a super resolution technique is introduced into our measurement, which gives MTF values both above and below Nyquist more accurately. 展开更多
关键词 EBCCD modulation transfer function super resolution low light level imaging
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部