期刊文献+
共找到1,072篇文章
< 1 2 54 >
每页显示 20 50 100
Genetic Transformation of Watermelon with Pumpkin DNA by Low Energy Ion Beam-mediated Introduction 被引量:8
1
作者 王浩波 高秀武 +2 位作者 郭金华 黄群策 余增亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2002年第6期1591-1596,共6页
The No.601 watermelon (citrullus lanatus) seeds were treated with 25 keV N+ implantation at the dosage of 7.8 ×1016 ions/cm2. After treatment, watermelon seeds were incubated with 380μg/μl pumpkin (Cucubita, ma... The No.601 watermelon (citrullus lanatus) seeds were treated with 25 keV N+ implantation at the dosage of 7.8 ×1016 ions/cm2. After treatment, watermelon seeds were incubated with 380μg/μl pumpkin (Cucubita, maxima Duch) DNA solution at 35 ℃ for 5 hours. By two-generations of selection and resistance screening at seedling stage, one transformed material was selected out, whose rind color is similar to that of the donor pumpkin and whose size of seeds is between that of the donor and the receptor. Using AFLP (amplified fragment length polymorphism) technique, two polymorphic DNA fragments were amplified. This primarily testified that the donor DNA fragments/gene were introduced into the receptor cell and integrated into the genomic DNA of the receptor. 展开更多
关键词 low energy ion beam pumpkin DNA WATERMELON genetic transformation AFLP
下载PDF
Bioeffects of Low Energy Ion Beam Implantation:DNA Damage,Mutation and Gene Transter 被引量:2
2
作者 汤明礼 余增亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第4期513-518,共6页
Low-energy ion beam implantation (10 - 200 keV) has been proved to have a wide range of biological effects and is broadly used in the breeding of crops and micro-organisms.To understand its mechanisms better and fac... Low-energy ion beam implantation (10 - 200 keV) has been proved to have a wide range of biological effects and is broadly used in the breeding of crops and micro-organisms.To understand its mechanisms better and facilitate its applications, the developments in the bioeffects of low energy ion beam implantation in the past twenty years are summarized in this paper. 展开更多
关键词 low energy ion beam IMPLANTATION DNA damage MUTATION gene transfer
下载PDF
Preliminary Studies on Base Substitutions and Repair of DNA Mismatch Damage Stimulated by Low Energy N^+ Ion Beam Implantation in Escherichia coli 被引量:4
3
作者 谢传晓 郭金华 +1 位作者 程备久 余增亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第1期1677-1682,共6页
Ever since the low energy N+ ion beam has been accepted that the mutation effects of ionizing radiation are attributed mainly to direct or indirect damage to DNA. Evidences based on naked DNA irradiation in support of... Ever since the low energy N+ ion beam has been accepted that the mutation effects of ionizing radiation are attributed mainly to direct or indirect damage to DNA. Evidences based on naked DNA irradiation in support of a mutation spectrum appears to be consistent, but direct proof of such results in vivo are limited. Using mutS, dam and/or dcm defective Eschericha coli imitator strains, an preliminary experimental system on induction of in vivo mutation spectra of low energy N+ ion beam has been established in this study. It was observed that the mutation rates of rifampicin resistance induced by N+ implantation were quite high, ranging from 9.2 x 10~8 to 4.9× 10~5 at the dosage of 5.2×1014 ions/cm2. Strains all had more than 90-fold higher mutation rate than its spontaneous mutation rate determined by this method. It reveals that base substitutions involve in induction of mutation of low energy nitrogen ion beam implantation. The mutation rates of mutator strains were nearly 500-fold (GM2929), 400-fold (GM5864) and 6-fold larger than that of AB1157. The GM2929 and GM5864 both lose the ability of repair DNA mismatch damage by virtue of both dam and dcm pathways defective (GM2929) or failing to assemble the repair complex (GM5864) respectively. It may explain the both strains had a similar higher mutation rate than GM124 did. It indicated that DNA cytosine methylase might play an important role in mismatch repair of DNA damage induced by N+ implantation. The further related research were also discussed. 展开更多
关键词 low energy N^+ ion beam base substitutions dam(DNA adenine methylase) dcm(DNA cytosine methylase) MUTS MMR (mismatch repair) Escherichia coli mutator strain
下载PDF
A segmented conical electric lens for optimization of the beam spot of the low-energy muon facility at PSI: a Geant4 simulation analysis 被引量:1
4
作者 Ran Xiao Elvezio Morenzoni +2 位作者 Zaher Salman Bang-Jiao Ye Thomas Prokscha 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第3期13-22,共10页
The low-energy muon facility at PSI provides nearly fully polarized positive muons with tunable energies in the ke V range to carry out muon spin rotation(LE-μSR)experiments with nanometer depth resolution on thin fi... The low-energy muon facility at PSI provides nearly fully polarized positive muons with tunable energies in the ke V range to carry out muon spin rotation(LE-μSR)experiments with nanometer depth resolution on thin films,heterostructures, and near-surface regions. The low-energy muon beam is focused and transported to the sample by electrostatic lenses. In order to achieve a minimum beam spot size at the sample position and to enable the steering of the beam in the horizontal and vertical direction, a special electrostatic device has been implemented close to the sample position. It consists of a cylinder at ground potential followed by four conically shaped electrodes,which can be operated at different electric potential. In LE-μSR experiments, an electric field at the sample along the beam direction can be applied to accelerate/decelerate muons to different energies(0.5–30 keV). Additionally, a horizontal or vertical magnetic field can be superimposed for transverse or longitudinal field μSR experiments. The focusing properties of the conical lens in the presence of these additional electric and magnetic fields have been investigated and optimized by Geant4 simulations. Some experimental tests were also performed and show that the simulation well describes the experimental setup. 展开更多
关键词 MUON beam MUON spin rotation low-ENERGY MUON beam size GEANT4
下载PDF
Electron-beam radiation effects on the structure and properties of polypropylene at low dose rates 被引量:5
5
作者 Heng-Ti Wang Hai-Qing Jiang +4 位作者 Rong-Fang Shen Xiao-Jun Ding Cong Zhang Lin-Fan Li Jing-Ye Li 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第6期101-109,共9页
While the high-energy radiation effects on polypropylene, which are crucial for the cable industry for nuclear power plants, have been thoroughly studied, the property changes of PP at low-dose-rate electron-beam irra... While the high-energy radiation effects on polypropylene, which are crucial for the cable industry for nuclear power plants, have been thoroughly studied, the property changes of PP at low-dose-rate electron-beam irradiation are far from elucidated. Herein, the influence of electron-beam irradiation on the structure and properties of PP was examined. The static EB irradiation conditions were 1.2 MeV at a low dose rate of 20 kGy/h to achieve absorbed doses ranging from 45, to 60, 100, and 200 kGy.The molecular structure was first evaluated by measuring the carboxyl index and the relative radical concentrations via Fourier transform infrared spectroscopy and electron spin resonance, respectively. Mechanical, differential scanning colorimetric, and rheological tests were carried out to further investigate the changes in the properties(tensile, crystalizing, and viscoelastic properties) of irradiated PP, which showed good agreement with the structural analysis results. We found that radio-oxidative degradation(chain scission) was predominant, which can be due to the low dose rate facilitating oxygen diffusion into the PP matrix during electron-beam irradiation. 展开更多
关键词 性质变化 低剂量率 聚丙烯 电子 横梁 结构 放射 FOURIER
下载PDF
Impact of Low-Energy Ion Beam Implantation on the Expression of Ty1-copia-like Retrotransposons in Wheat(Triticum aestivum) 被引量:6
6
作者 押辉远 焦浈 +3 位作者 谷运红 王卫东 秦广雍 霍裕平 《Plasma Science and Technology》 SCIE EI CAS CSCD 2007年第5期626-633,共8页
Retrotransposon-like elements are major constituents of most eukaryotic genomes. For example, they account for roughly 90% of the wheat (Triticum aestivum) genome, Previous study on a wheat strain treated by low-ene... Retrotransposon-like elements are major constituents of most eukaryotic genomes. For example, they account for roughly 90% of the wheat (Triticum aestivum) genome, Previous study on a wheat strain treated by low-energy N^+ ions indicated the variations in AFLP (Amplified Fragment Length Polymorphism ) markers, One such variation was caused by the re-activation of Tyl-copia-like retrotransposons, implying that the mutagenic effects of lowenergy ions might work through elevated activation of retrotransposons, In this paper an expression profile of Tyl-copia-like retrotransposons in wheat treated by low-energy N^+ ions is reported, The reverse transcriptase (RT) domains of these retrotransposons were amplified by reverse-transcriptional polymerase chain reaction (RT-PCR) and sequentially cloned, 42 and 65 clones were obtained from the treated (CL) and control materials (CK), respectively, Sequence analysis of each clone was performed by software. Phylogeny and classification were calculated responding to the sequences of the RT domains. All the results show that there is much difference in the RT domain between the control sample and the treated sample, Especially, the RT domains from the treated group encode significantly more functional ORF (open reading frames) than those from the control sample, This observation suggests that the treated sample has higher activation of retrotransposons, possibly as a consequence of low-energy ion beam irradiation, It also suggests that retrotransposons in the two groups impact the host gene expression in two different ways and carry out different functions in wheat cells. 展开更多
关键词 low-energy ion beam mutation mechanism Tyl-copia-like Retrotransposons phylogeny gene expression
下载PDF
The feasibility and safety of high-intensity focused ultrasound combined with low-dose external beam radiotherapy as supplemental therapy for advanced prostate cancer following hormonal therapy 被引量:3
7
作者 Rui-Yi Wu Guo-Min Wang +4 位作者 Lei Xu Bo-Heng Zhang Ye-Qing Xu Zhao-Chong Zeng Bing Chen 《Asian Journal of Andrology》 SCIE CAS CSCD 2011年第3期499-504,515,共7页
The aim of this study was to investigate the feasibility and safety of high-intensity focused ultrasound (HIFU) combined with (+) low-dose external beam radiotherapy (LRT) as supplemental therapy for advanced p... The aim of this study was to investigate the feasibility and safety of high-intensity focused ultrasound (HIFU) combined with (+) low-dose external beam radiotherapy (LRT) as supplemental therapy for advanced prostate cancer (PCa) following hormonal therapy (HT). Our definition of HIFU+LRT refers to treating primary tumour lesions with HIFU in place of reduced field boost irradiation to the prostate, while retaining four-field box irradiation to the pelvis in conventional-dose external beam radiotherapy (CRT). We performed a prospective, controlled and non-randomized study on 120 patients with advanced PCa after HT who received HIFU, CRT, HIFU+LRT and HT alone, respectively. CT/MR imaging showed the primary tumours and pelvic lymph node metastases visibly shrank or even disappeared after HIFU +LRT treatment. There were significant differences among four groups with regard to overall survival (OS) and disease-specific survival (DSS) curves (P=0.018 and 0.015). Further comparison between each pair of groups suggested that the long-term DSS of the H IFU + LRT group was higher than those of the other three groups, but there was no significant difference between the HIFU+LRT group and the CRT group. Multivariable Cox's proportional hazard model showed that both HIFU+LRT and CRT were independently associated with DSS (P=0.001 and 0.035) and had protective effects with regard to the risk of death. Compared with CRT, HIFU +LRT significantly decreased incidences of radiation-related late gastrointestinal (GI) and genitourinary (GU) toxicity grade ≥ II. In conclusion, long-term survival of patients with advanced PCa benefited from strengthening local control of primary tumour and reRional lymph node metastases after HT. As an alternative to CRT, HIFU+LRT showed Rood efficacy and better safety. 展开更多
关键词 COMPLICATION high-intensity focused ultrasound hormonal therapy low-dose external beam radiotherapy prostate cancer survival rate
下载PDF
Mutation Breeding of an Organic Phosphorus-Solubilizing Bacterium B3 by Low Energy Ion Beam Implantation
8
作者 张祥胜 李友国 +3 位作者 吴跃进 周俊初 陈大松 雷磊 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第5期645-650,共6页
A preliminary study on the mutation breeding of an organic phosphorus-solubilizing bacterium B3 by low-energy N^+ ion beam was conducted. Analysis of dosage vs. survival rate and mutation rate showed that the dosage ... A preliminary study on the mutation breeding of an organic phosphorus-solubilizing bacterium B3 by low-energy N^+ ion beam was conducted. Analysis of dosage vs. survival rate and mutation rate showed that the dosage of 3×10^15 ions/cm^2 was optimal for the mutation. Some parameters for determining the efficient phosphorus content were studied to simplify the protocols for screening. Ultimately one reliable mutant was screened out under plating and flask-culturing screening conditions. Importantly, a novel phosphorus-dissolving mechanism is reported for the first time in terms of bio-surfactant production, which indicates that bio-surfactant might play a vital role in phosphorus-dissolving for some phosphobacteria. 展开更多
关键词 MUTATION phosphorus-dissolving bacteria Bacillus subtilis var phosphaticum low energy ion beam
下载PDF
Evidence for Base Substitutions and Repair of DNA Mismatch Damage Induced by Low Energy N^+ Ion Beam Implantation in E. coli
9
作者 谢传晓 Guo +6 位作者 Jinhua Yao Jianmin Wu Lijun Yu Zengliang 《High Technology Letters》 EI CAS 2003年第2期1-6,共6页
Ever since the low energy N + ion beam has been accepted, the mutations of ionizing radiation are attributable mainly to avoidance of DNA damages repair. Evidences based on in vivo proof results are limited. Using the... Ever since the low energy N + ion beam has been accepted, the mutations of ionizing radiation are attributable mainly to avoidance of DNA damages repair. Evidences based on in vivo proof results are limited. Using the E.coli wild type and mutator strains, the mutant frequencies suggest that base substitutions in rpoB gene are induced by the N + implantation. A highly conserved region is selected to get the direct evidence for base substitutions by sequence of the high fidelity PCR amplification products in mutants. Most of the mutants (90.9%, 40/44) have at least one base substitution in the amplification region. The evidences for CG to TA (55%, 22/40), AT to GC (20%, 8/40) and TA to CG (5%, 2/40) transitions are identified. The transversions are AT to TA (15%, 6/40) and GC to CG (5%, 2/40). It is suggested that DNA cytosine methylase might play an important role in mismatch repair of DNA damage induced by N + implantation by analysis of the mutant frequencies of mutator strains. 展开更多
关键词 low energy N + ion beam base substitutions mismatch repair mutator strains
下载PDF
Low Velocity Impact Response Analysis of Shape Memory Alloy Reinforced Composite Beam
10
作者 吴永东 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2005年第3期70-73,共4页
The low velocity impact responses of shape memory alloy ( SMA ) reinforced composite beams were analyzed by employing the finite element method. The finite element dynamic equntion was solved by the Newmark direct i... The low velocity impact responses of shape memory alloy ( SMA ) reinforced composite beams were analyzed by employing the finite element method. The finite element dynamic equntion was solved by the Newmark direct integration method, the impact contact force was determined asing the Hertzian contact law, and the influence of SMA .fibers on stiffiwss matrix is studied. Numerical results show that the SMA fibers can effectively improve the low velocity impact response property of composite beam. 展开更多
关键词 shape memory alloy composite beam low velocity impact FEM
下载PDF
Analysis of a Partial Male-Sterile Mutant of Arabidopsis thaliana Isolated from a Low-Energy Argon Ion Beam Mutagenized Pool
11
作者 徐敏 卞坡 +1 位作者 吴跃进 余增亮 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第2期265-269,共5页
A screen for Arabidopsis fertility mutants, mutagenized by low-energy argon ion beam, yielded two partial male-sterile mutants tc243-1 and tc243-2 which have similar phenotypes. tc243-2 was investigated in detail. The... A screen for Arabidopsis fertility mutants, mutagenized by low-energy argon ion beam, yielded two partial male-sterile mutants tc243-1 and tc243-2 which have similar phenotypes. tc243-2 was investigated in detail. The segregation ratio of the mutant phenotypes in the M2 pools suggested that mutation behaved as single Mendelian recessive mutations, tc243 showed a series of mutant phenotypes, among which partial male-sterile was its striking mutant characteristic. Phenotype analysis indicates that there are four factors leading to male sterility, a. Floral organs normally develop inside the closed bud, but the anther filaments do not elongate sufficiently to position the locules above the stigma at anthesis, b. The anther locules do not dehisce at the time of flower opening (although limited dehiscence occurs later), c. Pollens of mutant plants develop into several types of pollens at the trinucleated stage. as determined by staining with DAPI (4',6-diamidino-2-phenylindole). which shows a variable size. shape and number of nucleus. d. The viability of pollens is lower than that of the wild type on the germination test in vivo and vitro. 展开更多
关键词 Arabidopsis thaliana Ar^+ low-energy ion beam Male-Sterile Mutant
下载PDF
Beam Characteristics at Low Dose Monitor Unit Settings for Vero4DRT
12
作者 Hideharu Miura Shuichi Ozawa +3 位作者 Shintaro Tsuda Masahiro Hayata Kiyoshi Yamada Yasushi Nagata 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2015年第4期284-289,共6页
The stability of delivery of low monitor unit (MU) setting is important especially for step-and-shoot intensity-modulated radiotherapy (IMRT), because the nature of the technique is inherent to repeat beam on/off acco... The stability of delivery of low monitor unit (MU) setting is important especially for step-and-shoot intensity-modulated radiotherapy (IMRT), because the nature of the technique is inherent to repeat beam on/off according to the number of the segments. This study evaluates the dose linearity and profile flatness/symmetry under low MU settings for Vero4DRT, a new linear-accelerator based irradiation system that currently implements step-and-shoot IMRT. To evaluate the dose linearity and flatness/symmetry, the point doses and beam profiles were measured as functions of MU and dose rates. The accuracy of dose delivery depended on the dose rate. Under all dose rates, the dose was linear within 1% above 5 MU and within 2% above 3 MU. The beam symmetry was degraded in-line compared with crossline, although both profiles were symmetric within 2% at all dose settings. The profile flatness was also within 2% above 5 MU at any dose rate and showed no significant variation among the low MU settings. To ensure stable beam delivery without increasing the treatment time of Vero4DRT, we recommend a delivery of 5 MU per segment at a dose rate of 500 MU/min. 展开更多
关键词 Vero4DRT Step-and-Shoot IMRT low MONITOR UNIT beam Characteristic
下载PDF
Slice-wise reconstruction for low-dose cone-beam CT using a deep residual convolutional neural network 被引量:4
13
作者 Hong-Kai Yang Kai-Chao Liang +1 位作者 Ke-Jun Kang Yu-Xiang Xing 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第4期53-61,共9页
Because of the growing concern over the radiation dose delivered to patients, X-ray cone-beam CT(CBCT) imaging of low dose is of great interest. It is difficult for traditional reconstruction methods such as Feldkamp ... Because of the growing concern over the radiation dose delivered to patients, X-ray cone-beam CT(CBCT) imaging of low dose is of great interest. It is difficult for traditional reconstruction methods such as Feldkamp to reduce noise and keep resolution at low doses. A typical method to solve this problem is using optimizationbased methods with careful modeling of physics and additional constraints. However, it is computationally expensive and very time-consuming to reach an optimal solution. Recently, some pioneering work applying deep neural networks had some success in characterizing and removing artifacts from a low-dose data set. In this study,we incorporate imaging physics for a cone-beam CT into a residual convolutional neural network and propose a new end-to-end deep learning-based method for slice-wise reconstruction. By transferring 3D projection to a 2D problem with a noise reduction property, we can not only obtain reconstructions of high image quality, but also lower the computational complexity. The proposed network is composed of three serially connected sub-networks: a cone-to-fan transformation sub-network, a 2D analytical inversion sub-network, and an image refinement sub-network. This provides a comprehensive solution for end-to-end reconstruction for CBCT. The advantages of our method are that the network can simplify a 3D reconstruction problem to a 2D slice-wise reconstruction problem and can complete reconstruction in an end-to-end manner with the system matrix integrated into the network design. Furthermore, reconstruction can be less computationally expensive and easily parallelizable compared with iterative reconstruction methods. 展开更多
关键词 CONE-beam CT Slice-wise RESIDUAL U-net low dose Image DENOISING
下载PDF
A New Synthesis Method for Sum and Difference Beam Pattern with Low Sidelobe
14
作者 徐振华 黄建国 张群飞 《Defence Technology(防务技术)》 SCIE EI CAS 2011年第2期72-77,共6页
A new method for sum and difference beam pattern synthesis with low sidelobe is proposed.In the situation of phase taper weighting,it makes use of Fourier transform pair relationship existing between the array factor ... A new method for sum and difference beam pattern synthesis with low sidelobe is proposed.In the situation of phase taper weighting,it makes use of Fourier transform pair relationship existing between the array factor and the element excitations and uses a loop iterative way to derive the array element excitations according to given array factor.The iteration does not stop until the array element excitations meet the initial sidelobe requirements.The method overcomes the defects of traditional methods,such as more searching times,larger amount of calculation and poor robustness.In addition,it can also synthesize the low sidelobe pattern in case of element failures.Simulation verifies the effectiveness of the method. 展开更多
关键词 光束合成 低副瓣 光束模式 数组元素 循环迭代 傅里叶变换 传统方法 搜索时间
下载PDF
迈腾B8前照灯结构及故障诊断逻辑分析
15
作者 张庆良 郭世璋 李程 《机械工程师》 2024年第9期114-117,共4页
介绍了迈腾B8灯光系统的主要组成:灯具、开关、保险、接地、继电器、控制单元。进而介绍迈腾B8前大灯的组成及前照灯的灯光控制系统组成。归纳、绘制了迈腾B8的前大灯电路控制原理图,表述了相关的控制单元、用电设备、开关、继电器的关... 介绍了迈腾B8灯光系统的主要组成:灯具、开关、保险、接地、继电器、控制单元。进而介绍迈腾B8前大灯的组成及前照灯的灯光控制系统组成。归纳、绘制了迈腾B8的前大灯电路控制原理图,表述了相关的控制单元、用电设备、开关、继电器的关联。在迈腾B8的远光电路控制原理基础上,解释了LED前大灯的工作机理及近光、远光的电流路径。基于电流形成路径,总结了故障诊断时的电压、电阻检测条件、方法与结果。 展开更多
关键词 迈腾B8 发光二极管 控制单元 近光灯 远光灯
下载PDF
近光灯八点配光设计
16
作者 张涛 《汽车零部件》 2024年第4期12-18,共7页
基于GB、ECE和FMVSS三个标准体系中近光灯照明区域关于Ⅲ区内八点照度的配光要求,研究通过优化近光透镜(PES)模组结构实现八点照度配光设计,论述了两种光学方案及其工作原理。采用光线追踪的方式,详细分析其结构特征、质量保证,并模拟... 基于GB、ECE和FMVSS三个标准体系中近光灯照明区域关于Ⅲ区内八点照度的配光要求,研究通过优化近光透镜(PES)模组结构实现八点照度配光设计,论述了两种光学方案及其工作原理。采用光线追踪的方式,详细分析其结构特征、质量保证,并模拟其配光结果,对比两种方案优缺点,为灯具设计提供理论依据和设计方案。 展开更多
关键词 透镜模组 近光灯 八点照度 汽车灯具
下载PDF
高黏橡胶改性沥青制备及其流变性能研究
17
作者 石福周 王瑶玉 +1 位作者 龙朵 崔武军 《合成材料老化与应用》 CAS 2024年第4期62-65,共4页
排水路面是促进可持续发展和建设海绵城市的有效方法之一,该文研究适用于排水沥青路面的高黏改性沥青,采用主要成分为SBS颗粒和高黏橡胶颗粒对基质沥青进行改性,通过正交试验,分别采用60℃动力黏度、软化点、针入度、延度、弹性恢复指... 排水路面是促进可持续发展和建设海绵城市的有效方法之一,该文研究适用于排水沥青路面的高黏改性沥青,采用主要成分为SBS颗粒和高黏橡胶颗粒对基质沥青进行改性,通过正交试验,分别采用60℃动力黏度、软化点、针入度、延度、弹性恢复指标确定高黏橡胶改性沥青的最佳掺量。选择常用的TPS改性剂和XC改性剂作为对照组进行对比分析,利用弯曲梁流变试验(BBR)和动态剪切流变试验(DSR)对三种高黏沥青的低温抗裂性和高温稳定性进行分析和评价,结果表明根据正交试验获得的最佳配方所制得的高黏橡胶改性沥青性能优良,为高黏改性沥青在道路工程领域中的开发和应用提供有价值的参考。 展开更多
关键词 正交试验 高黏沥青 动态剪切流变试验 低温弯曲梁流变试验
下载PDF
低预应力CFRP板加固RC梁模型试验研究
18
作者 常丁 庞立 雷涛 《公路工程》 2024年第3期36-41,共6页
为研究低预应力CFRP加固RC梁的力学性能,设计进行了CFRP加固方法的对比模型梁试验。通过对直接粘贴、机械张拉粘贴锚固成为低应力CFRP板及粘贴加热伸长后回缩成为低预应力CFRP板这3种方法,将同规格的CFRP板粘贴在混凝土试验梁表面,通过... 为研究低预应力CFRP加固RC梁的力学性能,设计进行了CFRP加固方法的对比模型梁试验。通过对直接粘贴、机械张拉粘贴锚固成为低应力CFRP板及粘贴加热伸长后回缩成为低预应力CFRP板这3种方法,将同规格的CFRP板粘贴在混凝土试验梁表面,通过分级加载试验,获得不同施工方法的CFRP板加固后开裂荷载、极限荷载、裂缝发展及荷载-挠度曲线等。试验结果表明:3种施工方法下进行机械张拉低预应力CFRP板加固对原梁抗剪承载力性能提高较大。在正常使用阶段,机械张拉低预应力CFRP板加固梁和加热张拉低预应力CFRP板加固梁出现斜裂缝的荷载等级高于直接粘贴CFRP加固梁出现斜裂缝的荷载等级。机械张拉低预应力CFRP板加固梁和加热张拉低预应力CFRP板加固梁产生的裂缝宽度小于直接粘贴CFRP板加固梁产生的裂缝宽度。相对最明显的是机械张拉低预应力CFRP板,裂缝一直维持在较低水平。粘贴锚固的低预应力CFRP加固方式操作相对简单,可应用于桥梁维修或拆除前临时加固工程等。 展开更多
关键词 低预应力 CFRP板 钢筋混凝土梁 力学性能
下载PDF
高增益低旁瓣宽扇形波束脊形波导缝隙天线阵列设计
19
作者 姚华飞 邱琳琳 +1 位作者 王安康 马亚东 《电波科学学报》 CSCD 北大核心 2024年第3期544-551,共8页
提出了一种具有高增益低副瓣的脊形波导缝隙阵列天线,中心工作频率为24.125 GHz,其包括一个八路馈电网络和一个尺寸为400 mm×65 mm的8×40辐射缝隙。通过波束合成方法提取天线阵列的期望激励分布,采用截止模式功率分配器灵活... 提出了一种具有高增益低副瓣的脊形波导缝隙阵列天线,中心工作频率为24.125 GHz,其包括一个八路馈电网络和一个尺寸为400 mm×65 mm的8×40辐射缝隙。通过波束合成方法提取天线阵列的期望激励分布,采用截止模式功率分配器灵活控制功率比。使用三维电磁仿真软件HFSS综合仿真计算,在中心频率处,获得仰角平面上的旁瓣电平(sidelobe level,SLL)和半功率波束宽度(half power beam width,HPBW)分别为-20.9 dB和54.5°、方位角平面上的SLL和HPBW分别为-27.8 dB和2.5°、峰值增益为23.2 dBi,仿真结果与理论分析一致。此天线可以同时实现低旁瓣的宽扇形波束,覆盖较宽的检测范围,并减轻来自其他方向的干扰,具有应用于空中探测、反无人机、气象雷达和成像雷达的潜力。 展开更多
关键词 脊形波导阵列天线 低副瓣 宽扇形波束 截止模式功率分配器 空中探测
下载PDF
L形钢管混凝土柱-钢梁节点的抗震性能试验研究及有限元分析
20
作者 张继承 卢盛庆 +1 位作者 杨浩 刘孝禹 《长江大学学报(自然科学版)》 2024年第5期128-138,共11页
为了研究异形钢管混凝土节点的抗震性能,按照1∶2缩尺比例制作了6根L形钢管混凝土柱-钢梁节点试件。通过低周往复试验,探讨了轴压比、梁柱线刚度比和是否带楼板等因素对节点抗震性能的影响。试验结果表明:试件滞回曲线饱满,试件展现出... 为了研究异形钢管混凝土节点的抗震性能,按照1∶2缩尺比例制作了6根L形钢管混凝土柱-钢梁节点试件。通过低周往复试验,探讨了轴压比、梁柱线刚度比和是否带楼板等因素对节点抗震性能的影响。试验结果表明:试件滞回曲线饱满,试件展现出较好的抗震性能;随着梁柱线刚度比的增大,试件的强度、刚度和延性均有所提高;随着轴压比的增大,其耗能能力也增加,但延性有所下降;此外,混凝土楼板的存在对节点承载力的影响较大。利用ABAQUS有限元软件建立有限元模型进行仿真模拟分析,结果显示,有限元计算结果与试验结果符合度较好,从而验证了有限元建模的准确性,为参数分析提供依据。 展开更多
关键词 异形钢管混凝土 钢梁节点 低周往复 滞回曲线 有限元
下载PDF
上一页 1 2 54 下一页 到第
使用帮助 返回顶部