期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Effect of Low Frequency Electromagnetic Field on Macrosegregation of Horizontal Direct Chill Casting Aluminum Alloys
1
作者 Zhihao ZHAO, Jianzhong GUI, Jie DONG and Beijiang ZHANGThe Key Laboratory of Electromagnetic Processing of Materials, Ministry of Education, P.O. Box 314, Northeastern University, Shenyang 110004, ChinaPh.D. candidate, 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2005年第1期75-78,共4页
The horizontal direct chill (HDC) casting process is a well-established production route for aluminum alloy ingot but the ingot may suffer from macrosegregation sometimes. In order to control the defect, a low frequen... The horizontal direct chill (HDC) casting process is a well-established production route for aluminum alloy ingot but the ingot may suffer from macrosegregation sometimes. In order to control the defect, a low frequency electromagnetic field has been applied in HDC casting process and the relevant influence has been studied. The results show that application of low frequency electromagnetic field can reduce macrosegregation in HDC casting process; and two main parameters of electromagnetic field density and frequency, have great influences on the solution distribution along the diameter of ingot. Moreover, the mechanisms of reduction of macrosegregation by electromagnetic field have been discussed. 展开更多
关键词 low frequency electromagnetic field Horizontal direct chill casting MACROSEGREGATION Aluminum alloy
下载PDF
EFFECT OF LOW-FREQUENCY ELECTROMAGNETIC FIELD ON THE AS-CASTING MICROSTRUCTURES AND MECHANICAL PROPERTIES OF HDC 2024 ALUMINUM ALLOY 被引量:4
2
作者 Q.F. Zhu Z.H. Zhao J.Z. Cui Y.B. Zuo F. Qu 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2008年第3期205-210,共6页
The influences of the low frequency electromagnetic field on the horizontal direct chill casting process were investigated experimentally. Ingots of 2024 aluminum alloy with a cross size of 40 mm× 200 mm were pro... The influences of the low frequency electromagnetic field on the horizontal direct chill casting process were investigated experimentally. Ingots of 2024 aluminum alloy with a cross size of 40 mm× 200 mm were produced by the conventional horizontal chill casting process and low frequency electromagnetic horizontal chill casting processre- spectively. The as-cast structures and the mechanical property of the ingots were examined. The results showed that the low frequency electromagnetic field could sub- stantially refine the microstructures and pronouncedly reduce the macrosegregation in the horizontal direct chill casting process. Moreover, the surface quality of the ingot was prominently improved by the low frequency electromagnetic field. The fracture strength and elongation percentage of the ingot was increased with the low frequency electromagnetic field. 展开更多
关键词 Horizontal direct chill casting low frequency electromagnetic field 2024 aluminum alloy MICROSTRUCTURES MACROSEGREGATION
下载PDF
Efects of low frequency electromagnetic ield on surface quality, microstructure and hot-tearing tendency of semi-continuous casting ZK60 magnesium alloy billets 被引量:3
3
作者 Zhang Zhiqiang Le Qichi +1 位作者 Bao Lei Cui Jianzhong 《China Foundry》 SCIE CAS 2013年第6期351-354,共4页
The low frequency electromagnetic field was applied during direct chill(DC) semi-continuous casting of the ZK60 magnesium alloy billets. Effects of low frequency electromagnetic field on surface quality, microstructur... The low frequency electromagnetic field was applied during direct chill(DC) semi-continuous casting of the ZK60 magnesium alloy billets. Effects of low frequency electromagnetic field on surface quality, microstructure and hot-tearing tendency of Φ500 mm ZK60 magnesium alloy billets were investigated. The results showed that with the application of the low frequency electromagnetic field, the surface quality of the ZK60 magnesium alloy billets is markedly improved and the depth of cold fold is decreased. The microstructure of the billets is also significantly refined. Besides, the distribution of the grain size is relatively uniform from the billet surface towards its center, where the average grain size is 42 μm at surface and 50 μm at center. It also shows that the hot-tearing tendency of DC semi-continuous casting ZK60 magnesium alloy billets is significantly reduced under low frequency electromagnetic field. 展开更多
关键词 ZK60 magnesium alloy billets direct chill casting low frequency electromagnetic field REFINEMENT
下载PDF
Analysis and Simulation of the Influence of Electromagnetic Fields on Living Beings near HV Power Lines Using the FDTD Method
4
作者 Anthony Bassesuka Sandoka Nzao 《Open Journal of Applied Sciences》 2023年第12期2343-2359,共17页
Recent decades have seen rapid advances in the field of electrical engineering, such that our environment has become a sea of electrical and magnetic signals, raising questions about the possible effects of low-freque... Recent decades have seen rapid advances in the field of electrical engineering, such that our environment has become a sea of electrical and magnetic signals, raising questions about the possible effects of low-frequency electromagnetic fields on the environment and which are capable of modifying and destroying our ecosystem. Particular interest was given in this article due to a massive influx of population living near high voltage lines. The analysis and simulation of the influence of low frequency electromagnetic fields on living beings in the vicinity of high voltage sources 132 kV and 220 kV in urban areas in DR Congo is the subject of our research with a view to estimating the level of exposure of humans to low frequency electromagnetic fields. To carry out our research, we used the classic method of analyzing the field produced near a high voltage line based on Maxwell’s image theory, the Maxwell-Gauss theorem and Maxwell-Ampère theorem to model and quantify low-frequency electromagnetic fields in the vicinity of high-voltage lines. The 2D FDTD numerical formulation was developed from telegraphers’ equations and allowed us to obtain models of current and voltage induced by electromagnetic fields on living beings below and near HV lines. The different simulations carried out on the proposed models illustrate the effects of the electrical and geometric parameters of the pylons on the distribution of the electromagnetic field in the vicinity of the HV lines. The results obtained were compared to the safety limits recommended by the standards. 展开更多
关键词 low frequency electromagnetic field Modeling field and Health Maxwell’s Equations FDTD Method electromagnetic Compatibility High Voltage Line
下载PDF
Effects of Different Electromagnetic Fields on Circadian Rhythms of Some Haematochemical Parameters in Rats
5
作者 LAURA CONTALBRIGO CALOGERO STELLETTA +4 位作者 LAURA FALCIONI STEFANIA CASELLA GIUSEPPE PICCIONE MORANDO SOFFRITTI AND MASSIMO MORGANTE 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2009年第4期348-353,共6页
Objective To investigate the effects of different electromagnetic fields on some haematochemical parameters of circadian rhythms in Sprague-Dawley rats. Methods The study was carried out in 18 male and 18 female rats ... Objective To investigate the effects of different electromagnetic fields on some haematochemical parameters of circadian rhythms in Sprague-Dawley rats. Methods The study was carried out in 18 male and 18 female rats in good health conditions exposed to 50 Hz magnetic sinusoid fields at the intensity of 1000 μT, 100 μT, and 0 μT (control group) respectively, and in 18 male and 18 female rats in good health conditions exposed to 1.8 GHz electromagnetic fields at the intensity of 50 V/m, 25 V/m and 0 V/m (control group), respectively. Following haematochemical parameters for glucose, triglycerides, and total cholesterol were measured. Results Different effects of electromagnetic fields on circadian rhythms of both male and female rats were observed. Different changes occurred in some haematochemical parameters for glucose, triglycerides, and total cholesterol (P〈0.05). Conclusion Exposure to different electromagnetic fields is responsible for the variations of some haematochemical parameters in rats. 展开更多
关键词 Extremely low frequency electromagnetic fields (50 Hz) Radiofrequency electromagnetic fields (1.8 GHz) Haematochemical parameters Circadian rhythm Sprague-Dawley rat
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部