The low level red light irradiation dose that produced positive response on different cell indexes was selected through experiments.In fibroblast detection model,the low level red light irradiation dose that had posit...The low level red light irradiation dose that produced positive response on different cell indexes was selected through experiments.In fibroblast detection model,the low level red light irradiation dose that had positive response to the four indicators of mitochondrial membrane potential,ATP release,cell migration and collagen synthesis was screened.The experimental results showed that low level red light with a irradiation dose of 2 J/cm^(2) had a positive response to the above four indexes in fibroblast.The test model on fibroblast was later transferred to dermal papilla cells for further experimental verification.The results showed that low level red light with a irradiation dose of 2 J/cm^(2) also had a positive response to the four indicators of dermal papilla cells,namely,mitochondrial membrane potential,ATP release,cell proliferation rate and collagen synthesis.It is proved that the low level red light with a irradiation dose of 2 J/cm^(2) could improve the mitochondrial function,cell migration and collagen synthesis of fibroblast and dermal papilla cell,thus providing energy for cell activities,improving cell repair ability and cell anti-aging ability.展开更多
A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the...A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the basis of the model created. Three uniform random sequences are built by the linear congruential method, of which two are used to form integer number and decimal fraction parts of the new random sequence respectively and the third to shuffle the new sequence. And then a Gauss sequence is formed out of uniform distribution by a function transforming method. It actualizes the simulation in real time of quantum noise in the low light imaging system, where video flow is extracted in real time, the noise summed up and played back side by side with the original video signs by a simulation software.展开更多
A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on differe...A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on difference processing. To obtain spatial relativity, images are shifted according to the motion parameters. As a result, the processing of integral and average can be applied to images that have been shifted. The technique of frame shift and integral that includes the algorithm of motion parameter determination is discussed, experiments with low light level moving image sequences are also described. The experiment results show the effectiveness and the robustness of the parameter determination algorithm, and the improvement in the signal-to-noise ratio (SNR) of low light level moving images.展开更多
In this paper a Y-type four-level atom interacting with external fields system is investigated. It is shown that increasing the control field can reduce the probe absorption, the electromagnetically induced transparen...In this paper a Y-type four-level atom interacting with external fields system is investigated. It is shown that increasing the control field can reduce the probe absorption, the electromagnetically induced transparency (EIT) and gain can be obtained if the parameters are taken appropriately. An interesting phenomenon is found that the system appears to be probe gain in a large region if the external fields Rabi phases are taken appropriately, too.展开更多
文摘The low level red light irradiation dose that produced positive response on different cell indexes was selected through experiments.In fibroblast detection model,the low level red light irradiation dose that had positive response to the four indicators of mitochondrial membrane potential,ATP release,cell migration and collagen synthesis was screened.The experimental results showed that low level red light with a irradiation dose of 2 J/cm^(2) had a positive response to the above four indexes in fibroblast.The test model on fibroblast was later transferred to dermal papilla cells for further experimental verification.The results showed that low level red light with a irradiation dose of 2 J/cm^(2) also had a positive response to the four indicators of dermal papilla cells,namely,mitochondrial membrane potential,ATP release,cell proliferation rate and collagen synthesis.It is proved that the low level red light with a irradiation dose of 2 J/cm^(2) could improve the mitochondrial function,cell migration and collagen synthesis of fibroblast and dermal papilla cell,thus providing energy for cell activities,improving cell repair ability and cell anti-aging ability.
文摘A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the basis of the model created. Three uniform random sequences are built by the linear congruential method, of which two are used to form integer number and decimal fraction parts of the new random sequence respectively and the third to shuffle the new sequence. And then a Gauss sequence is formed out of uniform distribution by a function transforming method. It actualizes the simulation in real time of quantum noise in the low light imaging system, where video flow is extracted in real time, the noise summed up and played back side by side with the original video signs by a simulation software.
文摘A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on difference processing. To obtain spatial relativity, images are shifted according to the motion parameters. As a result, the processing of integral and average can be applied to images that have been shifted. The technique of frame shift and integral that includes the algorithm of motion parameter determination is discussed, experiments with low light level moving image sequences are also described. The experiment results show the effectiveness and the robustness of the parameter determination algorithm, and the improvement in the signal-to-noise ratio (SNR) of low light level moving images.
基金supported by the National Natural Science Foundation of China(Grant Nos.10464002 and 60278016).
文摘In this paper a Y-type four-level atom interacting with external fields system is investigated. It is shown that increasing the control field can reduce the probe absorption, the electromagnetically induced transparency (EIT) and gain can be obtained if the parameters are taken appropriately. An interesting phenomenon is found that the system appears to be probe gain in a large region if the external fields Rabi phases are taken appropriately, too.