Objective: To investigate the correlation between radiation dose and radiation risk when patients are scanned by 64-slice spiral CT. Materials and Methods: SPSS 17.0 is used statistically for analyzing the patient’s ...Objective: To investigate the correlation between radiation dose and radiation risk when patients are scanned by 64-slice spiral CT. Materials and Methods: SPSS 17.0 is used statistically for analyzing the patient’s scanning parameters, radiation dose of monitoring and examining the patients who are scanning of their abdomen, chest and pelvic in our affiliated hospital. Results: SPSS statistical analysis shows that the factor related to radiation dose is scanning layer;the basic characteristics such as height and heart rate don’t affect the patient’s scan dose directly. Conclusion: Increasing the delay time after injection can reduce the scan numbers and monitoring layers of the machine, thus reduce the patient’s radiation dose and tube’s exposure time.展开更多
目的探讨256层螺旋CT迭代重建技术在骨盆骨折临床诊断中的应用价值。方法选取2016年1月-2018年1月本院收治并拟诊为骨盆骨折的120例患者作为研究对象,采用随机数表法将其分为A、B、C组与对照组,每组各30例。对照组为常规剂量(120 k V、2...目的探讨256层螺旋CT迭代重建技术在骨盆骨折临床诊断中的应用价值。方法选取2016年1月-2018年1月本院收治并拟诊为骨盆骨折的120例患者作为研究对象,采用随机数表法将其分为A、B、C组与对照组,每组各30例。对照组为常规剂量(120 k V、200 m As)扫描并采用滤波反投影重建(FBP),A组采用120 k V、160 m As低剂量扫描参数,B组采用120 k V、120 m As扫描参数,C组采用100k V、80 m As扫描参数,A、B、C组采用迭代i Dose4重建技术,对比四组诊断结果、图像质量以及患者所受辐射剂量情况。结果四组骨折检出率均为100.00%;四组图像质量主观评分维度中,对照组与A组、B组与C组图像噪声、图像伪影、图像对比、骨折显示评分比较均无显著差异(P>0.05),但B、C组图像噪声、图像伪影、图像对比、骨折显示评分明显低于对照组与A组(P<0.05);A、B、C三组噪声、SNR、CNR与对照组比较存在显著差异(P<0.05);但A、B、C三组组间比较无显著差异(P<0.05);四组患者CTDIvol、DLP指标比较均存在显著差异(P<0.05),并且以C组数值最低,而对照组数值最高。结论256层螺旋CT迭代重建技术能够在保证图像质量以及骨盆骨折准确正确率的前提下,显著降低患者所受辐射剂量,为患者提供一定的保护作用,同时也对降低CT球管损耗、延长球管寿命具有积极作用,在临床实际应用过程中应结合患者实际情况选择恰当的低剂量扫描参数。展开更多
文摘Objective: To investigate the correlation between radiation dose and radiation risk when patients are scanned by 64-slice spiral CT. Materials and Methods: SPSS 17.0 is used statistically for analyzing the patient’s scanning parameters, radiation dose of monitoring and examining the patients who are scanning of their abdomen, chest and pelvic in our affiliated hospital. Results: SPSS statistical analysis shows that the factor related to radiation dose is scanning layer;the basic characteristics such as height and heart rate don’t affect the patient’s scan dose directly. Conclusion: Increasing the delay time after injection can reduce the scan numbers and monitoring layers of the machine, thus reduce the patient’s radiation dose and tube’s exposure time.
文摘目的探讨256层螺旋CT迭代重建技术在骨盆骨折临床诊断中的应用价值。方法选取2016年1月-2018年1月本院收治并拟诊为骨盆骨折的120例患者作为研究对象,采用随机数表法将其分为A、B、C组与对照组,每组各30例。对照组为常规剂量(120 k V、200 m As)扫描并采用滤波反投影重建(FBP),A组采用120 k V、160 m As低剂量扫描参数,B组采用120 k V、120 m As扫描参数,C组采用100k V、80 m As扫描参数,A、B、C组采用迭代i Dose4重建技术,对比四组诊断结果、图像质量以及患者所受辐射剂量情况。结果四组骨折检出率均为100.00%;四组图像质量主观评分维度中,对照组与A组、B组与C组图像噪声、图像伪影、图像对比、骨折显示评分比较均无显著差异(P>0.05),但B、C组图像噪声、图像伪影、图像对比、骨折显示评分明显低于对照组与A组(P<0.05);A、B、C三组噪声、SNR、CNR与对照组比较存在显著差异(P<0.05);但A、B、C三组组间比较无显著差异(P<0.05);四组患者CTDIvol、DLP指标比较均存在显著差异(P<0.05),并且以C组数值最低,而对照组数值最高。结论256层螺旋CT迭代重建技术能够在保证图像质量以及骨盆骨折准确正确率的前提下,显著降低患者所受辐射剂量,为患者提供一定的保护作用,同时也对降低CT球管损耗、延长球管寿命具有积极作用,在临床实际应用过程中应结合患者实际情况选择恰当的低剂量扫描参数。