期刊文献+
共找到61,562篇文章
< 1 2 250 >
每页显示 20 50 100
Effects of Low-Intensity Ultrasound on Cell Proliferation and Reproductivity
1
作者 杨春梅 蒋学慧 +1 位作者 杜康 蔡启亮 《Transactions of Tianjin University》 EI CAS 2016年第2期125-131,共7页
Ultrasound has been widely used in clinics. Cellular responses to low-intensity ultrasound are parameter-dependent. Proper parameter setting is vital to its exact use. To get guidelines for parameter setting, lowinten... Ultrasound has been widely used in clinics. Cellular responses to low-intensity ultrasound are parameter-dependent. Proper parameter setting is vital to its exact use. To get guidelines for parameter setting, lowintensity ultrasound stimulation on the proliferation and reproductivity of Hep G2 and 3T3 cells in vitro was examined with a 1.06 MHz-generator by changing the parameters(including intensity, pulse repetition frequency and duty cycle)in a wide range. Cell viability and reproductivity at different time after sonication were measured by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide(MTT)and colony formation assay to indicate timerelated proliferation. The results illustrate that ultrasound irradiation at 0.4—0.8 W/cm^2 and high pulse repetition frequency(100 Hz)can facilitate cell proliferation, while above 0.8 W/cm^2 would resist it. The extent of resistance closely correlated with duty cycle and pulse repetition frequency. Resistance effect at low pulse repetition frequency(1 Hz)is greater than that at high pulse repetition frequency(100 Hz)and not time-related. The influence of high pulse repetition frequency is time-accumulated, indicating cellular process involved. These findings would provide valuable guidelines for the application of low-intensity ultrasound in stem cell transformation and tissue engineering. 展开更多
关键词 low-intensity ultrasound cell viability cell morphology cell proliferation cell reproductivity
下载PDF
Low-intensity ultrasound for regeneration of injured peripheral nerve
2
作者 Wei Zhou1, Wenzhi Chen2, Kun Zhou2, Zhibiao Wang2 1Third Department of Internal Medicine, Guang’an People’s Hospital, Guang’an 638000, Sichuan Province, China 2Institute of Ultrasound Engineering in Medicine, Biomedical Engineering Department, Chongqing Medical University, the National Key Laboratory of Chongqing Ultrasound Medical Engineering Department, Chongqing 400016, China 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第7期605-608,共4页
BACKGROUND: Ultrasound is a kind of mechanical wave and characterized by mechanical effect, heat effect and physical and chemical effect. Ultrasound can promote regeneration of peripheral nerves after a slight injury ... BACKGROUND: Ultrasound is a kind of mechanical wave and characterized by mechanical effect, heat effect and physical and chemical effect. Ultrasound can promote regeneration of peripheral nerves after a slight injury based on its mechanical effect. However, whether it can promote regeneration of peripheral nerves after a severe injury or not is still unclear. OBJECTIVE: To study the effect of low-intensity ultrasound (LIU) on regeneration of injured peripheral nerve, through examining sciatic nerve function index, the sensory nerve conduction velocity and the thickness of myelin sheath. DESIGN: Single factor design of contrast observation. SETTING: Institute of Ultrasound Engineering, Chongqing Medical University. MATERIALS: A total of 64 female Wistar rats, of clean grade, aged 3 months, weighing 200-250 g, were provided by Experimental Animal Center of Chongqing Medical University. All rats were randomly divided into treatment group and control group with 32 in each group. In addition, rats were observed at 4 time points, including 2, 4, 6 and 8 weeks, with 8 at each time point. The main equipments were detailed as follows: forceps (Medical Treatment Apparatus Company, Chongqing), low-intensity ultrasound treatment instrument (Institute of Ultrasound Engineering in Medicine), the analysis instrument of diagram resembles and arithmetic figure (the United States Bio-RAD Company), ultrasound coupling agent (Xunde Image material factory, Hangzhou), Osmium Tetraoxide (Next Chimica, South Africa). METHODS: The experiment was carried out in Institute of Ultrasound Engineering of Chongqing Medical University from December 2003 to May 2004. The right sciatic nerves of 64 rats were crushed with forceps for 30 s to form the experimental animal models. Then they were treated at 3 days after operation. Rats in the treatment group received the LIU exposure. LIU was applied every other day to the crush site of rats, which had a spatial peak, time-averaged intensity of 0.25 W/cm2 operated at 1 MHz for 1 minute per application for total 8 weeks. At various stages after operation, the sciatic nerve function index(SFI), the sensory nerve conduction velocity and its histology were detected. Rats in the control received a sham exposure. MAIN OUTCOME MEASURES: SFI; sensory nerve conduction velocity; density of myelinated nerve fiber; velocity of nerve regeneration; histological examination. RESULTS: Among 64 Wistar rats, 2 were lost during the experiment and another 2 were supplied. ① Histological examination: Two weeks after treatment, degeneration of axis-cylinder and myelin sheath was obvious in treatment group as compared with that in control group. Within 4-8 weeks after treatment, regeneration of axis-cylinder and myelin sheath of nerve fiber was superior in treatment group to that in control group. At 8 weeks after treatment, axis-cylinder and myelin sheath in treatment group were closed to normal value. Quantity of nerve fiber was less in control group than that in treatment group and the arrangement was disorder. At 2, 4 and 6 weeks after treatment, proliferation of Schwann cells was superior in treatment group to that in control group. At 6 and 8 weeks after treatment, proliferation of fiber tissue in nerve was severer in control group than that in treatment group. ② SFI: At 4, 6 and 8 weeks after treatment, SFI was higher in treatment group than that in control group (t =8.00, 12.41, 15.13, P < 0.01). ③ Sensory nerve conduction velocity: At 2, 4, 6 and 8 weeks after treatment, sensory nerve conduction velocity was faster in treatment group than that in control group (t =11.74, 10.81, 3.51, P < 0.01). ④ Density of myelinated nerve fiber: At 2, 4, 6 and 8 weeks after treatment, density of myelinated nerve fiber was higher in treatment group than that in control group (t =2.16, P < 0.05; t =3.29, 3.52, 3.23, P < 0.01). ⑤ Velocity of nerve regeneration: Velocity of nerve regeneration was (1.50±0.08) mm/d and (1.22±0.10) mm/d of treatment group and control group, respectively. This suggested that velocity of nerve regeneration was faster in treatment group than that in control group (t =2.708, P < 0.05). CONCLUSION: LIU can promote the regeneration of injured peripheral nerve from the appearance, construction, function aspect and functional recovery. Its mechanism may be through the modulation and effect of many links of nerve regeneration process. 展开更多
关键词 low-intensity ultrasound for regeneration of injured peripheral nerve
下载PDF
Feasibility of low-intensity ultrasound treatment with hydroxylamine to accelerate the initiation of partial nitrification and allow operation under intermittent aeration
3
作者 Jianxiong Jian Xiaojian Liao +7 位作者 Zhihua Mo Shoupeng Li Lei Li Shaojin Chen Zhenhua Huang Junhao Chen Wencan Dai Shuiyu Sun 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2024年第5期446-459,共14页
Partial nitrification is a key aspect of efficient nitrogen removal,although practically it suf-fers from long start-up cycles and unstable long-term operational performance.To address these drawbacks,this study inves... Partial nitrification is a key aspect of efficient nitrogen removal,although practically it suf-fers from long start-up cycles and unstable long-term operational performance.To address these drawbacks,this study investigated the effect of low intensity ultrasound treatment combined with hydroxylamine(NH2OH)on the performance of partial nitrification.Results showthat compared with the control group,low-intensity ultrasound treatment(0.10W/mL,15 min)combined with NH2OH(5 mg/L)reduced the time required for partial nitrification initiation by 6 days,increasing the nitrite accumulation rate(NAR)and ammonia nitro-gen removal rate(NRR)by 20.4% and 6.7%,respectively,achieving 96.48% NRR.Mechanis-tic analysis showed that NH2OH enhanced ammonia oxidation,inhibited nitrite-oxidizing bacteria(NOB)activity and shortened the time required for partial nitrification initiation.Furthermore,ultrasonication combined with NH2OH dosing stimulated EPS(extracellular polymeric substances)secretion,increased carbonyl,hydroxyl and amine functional group abundances and enhanced mass transfer.In addition,16S rRNA gene sequencing results showed that ultrasonication-sensitive Nitrospira disappeared from the ultrasound+NH_(2)OH system,while Nitrosomonas gradually became the dominant group.Collectively,the results of this study provide valuable insight into the enhancement of partial nitrification start-up during the process of wastewater nitrogen removal. 展开更多
关键词 Partial nitrification low-intensity ultrasound HYDROXYLAMINE Ammonia oxidizing bacteria Nitrite oxidizing bacteria
原文传递
Low-intensity pulsed ultrasound reduces alveolar bone resorption during orthodontic treatment via Lamin A/C-Yes-associated protein axis in stem cells 被引量:1
4
作者 Tong Wu Fu Zheng +7 位作者 Hong-Yi Tang Hua-Zhi Li Xin-Yu Cui Shuai Ding Duo Liu Cui-Ying Li Jiu-Hui Jiang Rui-Li Yang 《World Journal of Stem Cells》 SCIE 2024年第3期267-286,共20页
BACKGROUND The bone remodeling during orthodontic treatment for malocclusion often requires a long duration of around two to three years,which also may lead to some complications such as alveolar bone resorption or to... BACKGROUND The bone remodeling during orthodontic treatment for malocclusion often requires a long duration of around two to three years,which also may lead to some complications such as alveolar bone resorption or tooth root resorption.Low-intensity pulsed ultrasound(LIPUS),a noninvasive physical therapy,has been shown to promote bone fracture healing.It is also reported that LIPUS could reduce the duration of orthodontic treatment;however,how LIPUS regulates the bone metabolism during the orthodontic treatment process is still unclear.AIM To investigate the effects of LIPUS on bone remodeling in an orthodontic tooth movement(OTM)model and explore the underlying mechanisms.METHODS A rat model of OTM was established,and alveolar bone remodeling and tooth movement rate were evaluated via micro-computed tomography and staining of tissue sections.In vitro,human bone marrow mesenchymal stem cells(hBMSCs)were isolated to detect their osteogenic differentiation potential under compression and LIPUS stimulation by quantitative reverse transcription-polymerase chain reaction,Western blot,alkaline phosphatase(ALP)staining,and Alizarin red staining.The expression of Yes-associated protein(YAP1),the actin cytoskeleton,and the Lamin A/C nucleoskeleton were detected with or without YAP1 small interfering RNA(siRNA)application via immunofluorescence.RESULTS The force treatment inhibited the osteogenic differentiation potential of hBMSCs;moreover,the expression of osteogenesis markers,such as type 1 collagen(COL1),runt-related transcription factor 2,ALP,and osteocalcin(OCN),decreased.LIPUS could rescue the osteogenic differentiation of hBMSCs with increased expression of osteogenic marker inhibited by force.Mechanically,the expression of LaminA/C,F-actin,and YAP1 was downregulated after force treatment,which could be rescued by LIPUS.Moreover,the osteogenic differentiation of hBMSCs increased by LIPUS could be attenuated by YAP siRNA treatment.Consistently,LIPUS increased alveolar bone density and decreased vertical bone absorption in vivo.The decreased expression of COL1,OCN,and YAP1 on the compression side of the alveolar bone was partially rescued by LIPUS.CONCLUSION LIPUS can accelerate tooth movement and reduce alveolar bone resorption by modulating the cytoskeleton-Lamin A/C-YAP axis,which may be a promising strategy to reduce the orthodontic treatment process. 展开更多
关键词 low-intensity pulsed ultrasound Bone resorption OSTEOGENESIS Cytoskeleton-Lamin A/C-Yes-associated protein axis Bone marrow mesenchymal stem cells Orthodontic tooth movement
下载PDF
Pain Efficacy of a Home-Based Low-Intensity Continuous Ultrasound Stimulator for Knee Arthritis: A Single-Arm, Open-Label, Prospective Clinical Trial
5
作者 Md. Habibur Rahman Yeon-Gyu Jang +8 位作者 Johny Bajgai Subham Sharma Kchorng Vira Abdul-Nasir Sofian Seong Hoon Goh Yundeok Kim Cheol-Su Kim Doo-Sup Kim Kyu-Jae Lee 《Health》 2024年第7期703-716,共14页
1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee o... 1) Background: Osteoarthritis (OA) is defined as a degenerative joint disease that mainly affects the bone. This study aims to evaluate the effect of low-intensity continuous ultrasound (LICUS) treatment on the knee of osteoarthritis patients through home-based intervention using the LICUS medical device. 2) Methods: The clinical trials were designed in a single-arm, open-label, and intervention study. Thirty-five participants, including those who dropped out (12%), were screened and enrolled. The patients received LICUS (1.1 MHz, 1.5 W/cm2, collimated beams) on the knee by the instructions of the investigator at home (5 min/session, 3 times/day, for four-weeks). Outcome measures were assessed using the Visual Analog Scale (VAS) as a primary endpoint and the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) as a secondary endpoint to evaluate pain relief and functional recovery of the knee between pre-treatment (baseline) and post-treatment (four-weeks). 3) Results: Knee pain scores measured using the VAS and WOMAC indices were significantly reduced after a four-week treatment with LICUS compared to baseline. Knee stiffness and functional capacity were significantly reduced after the LICUS application. In addition, there were no reports of adverse effects during the study period. 4) Conclusion: Long-term and home-based application of LICUS can be recommended as an alternative option for the treatment of OA patients, as evidenced by the effect of pain relief and knee function recovery. 展开更多
关键词 Knee Osteoarthritis low-intensity Continuous ultrasound Stimulator Clinical Trial Visual Analogue Scale Western Ontario and McMaster Universities Osteoarthritis Index
下载PDF
Wideband frequency-dependent dielectric properties of rat tissues exposed to low-intensity focused ultrasound in the microwave frequency range
6
作者 王雪 Shi-Xie Jiang +3 位作者 黄林 迟子惠 吴丹 Hua-Bei Jiang 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期340-347,共8页
Tissue dielectric properties can vary upon the incident of an acoustic wave.The goal of this study is to quantify this change due to the acoustoelectric effect(AE),and to obtain the frequency-dependent dielectric prop... Tissue dielectric properties can vary upon the incident of an acoustic wave.The goal of this study is to quantify this change due to the acoustoelectric effect(AE),and to obtain the frequency-dependent dielectric properties of tissues exposed to low-intensity focused ultrasound(LIFU).The dielectric properties of the blood,brain,chest muscle,heart,kidney,leg muscle,liver,lung,pancreas,and spleen of rats were measured by an open-ended coaxial probe method.The acoustic intensity of LIFU focus was 2.97 MPa(67.6 W/cm^(2)),3.95 MPa(120 W/cm^(2)),and 5.17 MPa(204 W/cm^(2)),respectively,and the measurement frequency band was 0.1–7.08 GHz.The measurement results show that with the LIFU modulation,the conductivity and dielectric constant decreased in the high-frequency band,and on the contrary,they increased in the lowfrequency band,and the larger the acoustic intensity was,the more obvious the phenomenon was.This work contributes to a better understanding of the mechanisms by which ultrasound acts on the dielectric properties of biological tissues.It is expected that the findings from this study will provide a basis that the response of tissue to LIFU modulation can be monitored by noninvasive techniques such as microwave-induced thermoacoustic imaging(MTI)and microwave imaging,present a new idea for improving the endogenous contrast between different biological tissues in MTI and acoustoelectric imaging,and possibly lead to the development of a new imaging method based on the relaxation time of tissue after LIFU modulation. 展开更多
关键词 dielectric property rat tissues low-intensity focused ultrasound
下载PDF
Effects of low-intensity pulsed ultrasound stimulation on porous hydroxyapatite blocks for posterolateral fusion of lumbar spine in rabbits 被引量:2
7
作者 卓祥龙 吕红斌 +4 位作者 徐大启 刘彬 王锡阳 张莹 胡建中 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2010年第10期1921-1927,共7页
he effects of porous hydroxyapatite blocks(PHABs) and an adjunct low-intensity pulsed ultrasound stimulation(LIPUS) on the fusion rate in a rabbit spinal posterolateral fusion(PLF) model were evaluated.Twenty ra... he effects of porous hydroxyapatite blocks(PHABs) and an adjunct low-intensity pulsed ultrasound stimulation(LIPUS) on the fusion rate in a rabbit spinal posterolateral fusion(PLF) model were evaluated.Twenty rabbits underwent PLF with autograft and PHABs were randomly assigned to two groups:treated group with 20 min LIPUS daily and untreated control group for 4 weeks until euthanasia.The fused motion segments were subjected to manual palpation,gross observation,and radiographic investigation before histomorphologic and scanning electron microscopic analyses.Statistical differences between the LIPUS group and the control group are found in the fusion rate,bone density gray scale,trabecular bone formation,osteoblast-like cells,chondrocytes and positive expression of BMP-2 and TGF-β1 in the junction zone(significance level p〈0.05).The results suggest that LIPUS can increase fusion rates and accelerate bone in-growth into PHAB.Hence,PHAB and LIPUS may be used together to increase fusion rates in a rabbit spinal fusion model with a promising extension to human application. 展开更多
关键词 low-intensity pulsed ultrasound stimulation lumbar posterolateral fusion porous hydroxyapatite blocks
下载PDF
Effect of low-intensity pulsed ultrasound on posterolateral lumbar fusion of rabbit 被引量:1
8
作者 Jian Wang Jian-Wei Li Lei Chen 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2015年第1期68-72,共5页
Objective:To observe the effect of low-intensity pulsed ultrasound in the posterolateral Lumbar fusion of rabbit.Methods:A total of 48 New Zealand white rabbits were randomly divided into the observation group and con... Objective:To observe the effect of low-intensity pulsed ultrasound in the posterolateral Lumbar fusion of rabbit.Methods:A total of 48 New Zealand white rabbits were randomly divided into the observation group and control group,including the autogenous iliac observation group.artificial bone observation group,artificial bone control group and autogenous iliac control group according to the different bone grafting.The posterolateral lumbar fusion of rabbits in each group was analyzed and compared.Results:After 4 weeks of treatment using the low-intensity pulsed ultrasound,the fusion in the bone grafting area of observation group was good.There was the relatively dense fusion area between the right transverse process and artificial bone.The left transverse process had been completely fused,with the clear bone trabecula through the fusion area.There was no significant fusion sign in the control group.According to the fusion comparison between two groups,the fusion rale of the observation group was 83.3%and it was significantly higher than the one of the control group(37.5%).Results of the comparison were statistically significant(P<0.05).The number of chondrocytes and the increase in the relative gray-scale in the fusion area of the iliac observation group were significantly higher than ones of the iliac control group(P<0.05).The number of chondrocytes and the increase in the relative gray-scale in the fusion area of the artificial bone observation group were significantly higher than ones of the artificial bone control group(P<0.05).The expression of IL-1.IL-6 and IL-17 4 weeks after the treatment of the observation group was significantly lower than the one of the control group,with the statistical significance(P<0.05).It indicated that the treatment of low-intensity pulsed ultrasound could reduce the expression level of inflammatory factors.Conclusions:The low-intensity pulsed ultrasound can significantly increase the bone grafting fusion rate of the rabbit's posterolateral lumbar fusion.The possible mechanism is that it promotes the lumbar posterolateral endochondral ossification and reduces the inflammatory reaction. 展开更多
关键词 low-intensity PULSED ultrasound LUMBAR POSTEROLATERAL Fusion ILIUM
下载PDF
Seeing beneath the surface:Harnessing point-of-care ultrasound for internal jugular vein evaluation 被引量:2
9
作者 Vichayut Chayapinun Abhilash Koratala Taweevat Assavapokee 《World Journal of Cardiology》 2024年第2期73-79,共7页
Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to... Point-of-care ultrasound(POCUS)of the internal jugular vein(IJV)offers a noninvasive means of estimating right atrial pressure(RAP),especially in cases where the inferior vena cava is inaccessible or unreliable due to conditions such as liver disease or abdominal surgery.While many clinicians are familiar with visually assessing jugular venous pressure through the internal jugular vein,this method lacks sensitivity.The utilization of POCUS significantly enhances the visualization of the vein,leading to a more accurate identification.It has been demonstrated that combining IJV POCUS with physical examination enhances the specificity of RAP estimation.This review aims to provide a comprehensive summary of the various sonographic techniques available for estimating RAP from the internal jugular vein,drawing upon existing data. 展开更多
关键词 Point-of-care ultrasound Bedside ultrasound Internal jugular vein Right atrial pressure Central venous pressure
下载PDF
Diagnostic and therapeutic role of endoscopic ultrasound in liver diseases:A systematic review and meta-analysis 被引量:4
10
作者 Eyad Gadour Abeer Awad +3 位作者 Zeinab Hassan Khalid Jebril Shrwani Bogdan Miutescu Hussein Hassan Okasha 《World Journal of Gastroenterology》 SCIE CAS 2024年第7期742-758,共17页
BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefor... BACKGROUND In hepatology,the clinical use of endoscopic ultrasound(EUS)has experienced a notable increase in recent times.These applications range from the diagnosis to the treatment of various liver diseases.Therefore,this systematic review summarizes the evidence for the diagnostic and therapeutic roles of EUS in liver diseases.AIM To examine and summarize the current available evidence of the possible roles of the EUS in making a suitable diagnosis in liver diseases as well as the therapeutic accuracy and efficacy.METHODS PubMed,Medline,Cochrane Library,Web of Science,and Google Scholar databases were extensively searched until October 2023.The methodological quality of the eligible articles was assessed using the Newcastle-Ottawa scale or Cochrane Risk of Bias tool.In addition,statistical analyses were performed using the Comprehensive Meta-Analysis software.RESULTS Overall,45 articles on EUS were included(28 on diagnostic role and 17 on therapeutic role).Pooled analysis demonstrated that EUS diagnostic tests had an accuracy of 92.4%for focal liver lesions(FLL)and 96.6%for parenchymal liver diseases.EUS-guided liver biopsies with either fine needle aspiration or fine needle biopsy had low complication rates when sampling FLL and parenchymal liver diseases(3.1%and 8.7%,respectively).Analysis of data from four studies showed that EUS-guided liver abscess had high clinical(90.7%)and technical success(90.7%)without significant complications.Similarly,EUS-guided interventions for the treatment of gastric varices(GV)have high technical success(98%)and GV obliteration rate(84%)with few complications(15%)and rebleeding events(17%).CONCLUSION EUS in liver diseases is a promising technique with the potential to be considered a first-line therapeutic and diagnostic option in selected cases. 展开更多
关键词 Focal liver lesion Liver abscess drainage Fine needle aspiration Gastric varices Endoscopic ultrasound
下载PDF
Endoscopic-ultrasound-guided biliary drainage with placement of electrocautery-enhanced lumen-apposing metal stent for palliation of malignant biliary obstruction:Updated meta-analysis 被引量:6
11
作者 Zu-Xiang Peng Fang-Fang Chen +5 位作者 Wen Tang Xu Zeng Hong-Juan Du Ru-Xian Pi Hong-Ming Liu Xiao-Xiao Lu 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第3期907-920,共14页
BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant bili... BACKGROUND Endoscopic ultrasound-guided biliary drainage using electrocautery-enhanced(ECE)delivery of lumen-apposing metal stent(LAMS)is gradually being re-cognized as a viable palliative technique for malignant biliary obstruction after endoscopic retrograde cholangiopancreatography(ERCP)failure.However,most of the studies that have assessed its efficacy and safety were small and hetero-geneous.Prior meta-analyses of six or fewer studies that were published 2 years ago were therefore underpowered to yield convincing evidence.AIM To update the efficacy and safety of ECE-LAMS for treatment of biliary ob-struction after ERCP failure.METHODS We searched PubMed,EMBASE,and Scopus databases from the inception of the ECE technique to May 13,2022.Primary outcome measure was pooled technical success rate,and secondary outcomes were pooled rates of clinical success,re-intervention,and adverse events.Meta-analysis was performed using a random-effects model following Freeman-Tukey double-arcsine transformation in R soft-ware(version 4.1.3).RESULTS Fourteen eligible studies involving 620 participants were ultimately included.The pooled rate of technical success was 96.7%,and clinical success was 91.0%.Adverse events were reported in 17.5%of patients.Overall reinter-vention rate was 7.3%.Subgroup analyses showed results were generally consistent.CONCLUSION ECE-LAMS has favorable success with acceptable adverse events in relieving biliary obstruction when ERCP is impossible.The consistency of results across most subgroups suggested that this is a generalizable approach. 展开更多
关键词 Biliary obstruction Biliary drainage Electrocautery-enhanced lumen-apposing metal stents Endoscopic ultrasound Endoscopic retrograde cholangiopancreatography failure
下载PDF
Quick and easy assessment of sarcopenia in cirrhosis: Can ultrasound be the solution? 被引量:1
12
作者 Francesca Campani Tancredi Vincenzo Li Cavoli +3 位作者 Umberto Arena Fabio Marra Erica Nicola Lynch Claudia Campani 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2287-2293,共7页
Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and aff... Cirrhosis is frequently associated with sarcopenia,with reported rates of over 80%in patients with decompensated alcohol-related liver disease.Sarcopenia nega-tively impacts the prognosis of cirrhotic patients and affects the response to treatment of patients with hepatocellular carcinoma(HCC).For these reasons,identifying an easy-to-perform method to assess sarcopenia in is a key element in the optimization of care in this patient population.Assessment of muscle mass by computed tomography is considered the standard of care for the diagnosis of sarcopenia,but exposure to radiation and high costs limit its application in this setting,especially for repeated assessments.We believe that ultrasound,a cheap and harmless technique also used for HCC screening in cirrhotic patients,could have an expanding role in the diagnosis and follow-up of sarcopenia in these patients. 展开更多
关键词 SARCOPENIA ultrasound CIRRHOSIS Hepatocellular carcinoma Computed tomography
下载PDF
Prognostic value of ultrasound in early arterial complications post liver transplant 被引量:1
13
作者 Ning-Bo Zhao Yi Chen +2 位作者 Rui Xia Jian-Bo Tang Dong Zhao 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期13-20,共8页
Liver transplantation is the primary therapeutic intervention for end-stage liver disease.However,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.The clinical ... Liver transplantation is the primary therapeutic intervention for end-stage liver disease.However,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.The clinical manifestations associated with early arterial complications following liver transplantation are often non-specific.Without timely intervention,these complications can result in graft fai-lure or patient mortality.Therefore,early diagnosis and the formulation of an op-timal treatment plan are imperative.Ultrasound examination remains the pre-dominant imaging modality for detecting complications post liver transplan-tation.This article comprehensively reviews common causes and clinical present-ations of early hepatic artery complications in the post-transplantation period and delineates abnormal sonographic findings for accurate diagnosis of these con-ditions.Overall,ultrasound offers the advantages of convenience,safety,effect-iveness,and non-invasiveness.It enables real-time,dynamic,and precise evalua-tion,making it the preferred diagnostic method for post-liver transplantation assessments.INTRODUCTION Liver transplantation stands as the primary therapeutic approach for end-stage liver disease.Continuous advancements in surgical techniques and the application of novel immunosuppressive agents contribute to ongoing improvements in the success rate and overall survival in patients undergoing liver transplantation procedures.Despite these advan-cements,vascular complications,particularly those involving the hepatic artery,pose significant risks to patients.During the early stages following liver transplantation(within the first 30 d),proper hepatic artery function is crucial for hepatic arterial blood flow.During later stages,collateral circulation,including arteries such as the phrenic artery,right gastric artery,and gastroduodenal artery,becomes important for maintaining hepatic blood supply.It is now understood that the establishment of effective collateral circulation is pivotal for determining the prognosis of hepatic artery complic-ations.The clinical manifestations of these complications are closely linked to factors such as timing,severity,and the specific type of onset.Insufficient hepatic arterial blood flow can lead to abnormal liver function,hepatic infarction,and the formation of hepatic abscesses.Additionally,since the hepatic artery is the sole blood supply to the biliary tract,hepatic artery-related ischemia may result in biliary stricture,obstruction,and the formation of bile ducts.Ultrasound examination remains the primary imaging modality for diagnosing complications post liver transplantation.This article comprehensively reviews common causes and clinical presentations of early hepatic artery complications in the post-transplantation period and outlines abnormal sonographic findings for accurately diagnosing these conditions.NORMAL HEPATIC ARTERY During the intraoperative phase,an ultrasound examination is typically conducted to evaluate the hepatic artery anas-tomosis.The normal internal diameter of the hepatic artery typically ranges from 2 to 5 mm.Two strong echo points are typically identified near the anastomosis.To assess blood flow dynamics,peak systolic velocity,end-diastolic velocity,and resistance index are measured at the donor and recipient sides of the anastomosis following angle correction.Anastomotic stenosis presence and severity can be evaluated by comparing the velocity at the anastomotic site with that at the recipient side.Postoperatively,direct visualization of the anastomosis site through gray ultrasound scans is often challenging.The surgical approach has a significant impact on the proper hepatic artery’s position,resulting in a lower overall success rate of continuous visualization.Color Doppler ultrasound is primarily employed to trace the artery’s path,and spectral measurements are taken at the brightest position of the Color Doppler blood flow signal,primarily used to identify the presence of high-speed turbulence.Hepatic artery spectrum examination plays a crucial role,as a favorable arterial spectral waveform and appropriate hepatic artery flow velocity typically indicate a successful anastomosis,even in cases where the hepatic artery anastomosis cannot be directly visualized by ultrasound.The hepatic artery runs alongside the portal vein,often selected as a reference due to its larger inner diameter.A normal hepatic artery spectrum displays a regular pulsation pattern with a rapid rise in systole and a slow decline in diastole.Parameters for assessing hepatic artery resistance include a resistance index between 0.5 to 0.8 and an artery systolic acceleration of less than 80 ms.Instantaneous increases in the resistance index(RI>0.8)often occur within 2 d after surgery,followed by a subsequent return to normal hepatic arterial parameters.It has been established that the maximum blood flow velocity during systole in the hepatic artery should not exceed 200 cm/s[1]. 展开更多
关键词 Liver transplantation Vascular complication Arterial complication ultrasound
下载PDF
Novel approach of ultrasound-guided lateral recess block for a patient with lateral recess stenosis: A case report 被引量:1
14
作者 Jiao Yang Xin-Ling Li Qing-Bing Li 《World Journal of Clinical Cases》 SCIE 2024年第5期1010-1017,共8页
BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultraso... BACKGROUND Ultrasound guide technology,which can provide real-time visualization of the needle tip and tissues and avoid many adverse events,is widely used in mini-mally invasive therapy.However,the studies on ultrasound-guided Lateral recess block(LRB)are limited,this is probably because there is no recognized standard method for ultrasound scanning.This study aimed to evaluate the effect of ultrasound-guided LRB in patients with lateral recess stenosis(LRS).CASE SUMMARY A 65-year-old patient complained of low back pain accompanied occasionally by pain and numbness in the left lower limb.Physical examination showed ten-derness on the spinous process and paraspinal muscles from L1 to S1,extensor hallucis longus and tibialis anterior weakness(muscle strength:4-),and a positive straight leg raising test in the left lower limb(60°).Magnetic resonance imaging showed L4–L5 disc degeneration with left LRS and nerve root entrapment.Subsequently,the patient was diagnosed with LRS.This patient was treated with a novel ultrasound-guided LRB approach.The patient’s symptoms significantly improved without any complications at 1 wk postoperatively and at the 3-month follow-up.CONCLUSION This is the first report on the LRS treatment with ultrasound-guided LRB from the contralateral spinous process along the inner side of the articular process by out-plane technique.Further studies are expected to investigate the efficacy and safety of ultrasound-guided LRB for patients with LRS. 展开更多
关键词 Lateral recess stenosis ultrasound Lateral recess block Real-time visualization Low back pain Case report
下载PDF
Use of endoscopic ultrasound-guided gallbladder drainage as a rescue approach in cases of unsuccessful biliary drainage 被引量:1
15
作者 Alessandro Fugazza Kareem Khalaf +10 位作者 Katarzyna M Pawlak Marco Spadaccini Matteo Colombo Marta Andreozzi Marco Giacchetto Silvia Carrara Chiara Ferrari Cecilia Binda Benedetto Mangiavillano Andrea Anderloni Alessandro Repici 《World Journal of Gastroenterology》 SCIE CAS 2024年第1期70-78,共9页
This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally ... This narrative review provides an overview of the utilization of endoscopic ultrasound-guided gallbladder drainage(EUS-GBD)as a salvage approach in cases of unsuccessful conventional management.EUS-GBD is a minimally invasive and effective technique for drainage in patients with acute cholecystitis with high risk of surgery.The procedure has demonstrated impressive technical and clinical success rates with low rates of adverse events,making it a safe and effective option for appropriate candidates.Furthermore,EUS-GBD can also serve as a rescue option for patients who have failed endoscopic retrograde cholangiopancreatography or EUS biliary drainage for relief of jaundice in malignant biliary stricture.However,patient selection is critical for the success of EUS-GBD,and proper patient selection and risk assessment are important to ensure the safety and efficacy of the procedure.As the field continues to evolve and mature,ongoing research will further refine our understanding of the benefits and limitations of EUS-GBD,ultimately leading to improved outcomes for patients. 展开更多
关键词 Endoscopic ultrasound-guided gallbladder drainage Gallbladder drainage Acute cholecystitis Malignant obstruction Interventional endoscopic ultrasound Lumen-apposing metal stents
下载PDF
Contrast-enhanced guided endoscopic ultrasound procedures 被引量:1
16
作者 Marcel Ioan Gheorghiu Andrada Seicean +3 位作者 Cristina Pojoga Claudia Hagiu Radu Seicean Zeno Sparchez 《World Journal of Gastroenterology》 SCIE CAS 2024年第17期2311-2320,共10页
Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of t... Contrast-enhanced endoscopic ultrasound(CH-EUS)can overcome the limi-tations of endoscopic ultrasound-guided acquisition by identifying microvessels inside inhomogeneous tumours and improving the characterization of these tumours.Despite the initial enthusiasm that oriented needle sampling under CH-EUS guidance could provide better diagnostic yield in pancreatic solid lesions,further studies did not confirm the supplementary values in cases of tissue acquisition guided by CH-EUS.This review details the knowledge based on the available data on contrast-guided procedures.The indications for CH-EUS tissue acquisition include isoechoic EUS lesions with poor visible delineation where CH-EUS can differentiate the lesion vascularisation from the surrounding parenchyma and also the mural nodules within biliopancreatic cystic lesions,which occur in select cases.Additionally,the roles of CH-EUS-guided therapy in patients whose pancreatic fluid collections or bile ducts that have an echogenic content have indications for drainage,and patients who have nonvisualized vessels that need to be highlighted via Doppler EUS are presented.Another indication is represented if there is a need for an immediate assessment of the post-radiofrequency ablation of pancreatic neuroendocrine tumours,in which case CH-EUS can be used to reveal the incomplete tumour destruction. 展开更多
关键词 ENDOSONOGRAPHY Contrast-enhanced endoscopic ultrasound Tissue acquisition Fine needle aspiration Fine needle biopsy Drainage Pancreatic fluid collections BIOPSY PANCREAS
下载PDF
Evaluation of hand infections in the emergency department using point-of-care ultrasound
17
作者 David Ahmad Haidar David Mintz +2 位作者 Brandon M Wubben Omar Rizvi Srikar Adhikari 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第4期283-288,共6页
BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient mana... BACKGROUND:We aimed to evaluate the utility of point-of-care ultrasound(POCUS)in the assessment of hand infections that present to the emergency department(ED)and its impact on medical decision making and patient management.METHODS:We conducted a retrospective review of patients who presented to two urban academic EDs with clinical presentations concerning for skin and soft tissue infections(SSTI)of the hand between December 2015 and December 2021.Two trained POCUS fellowship physicians reviewed an ED POCUS database for POCUS examinations of the hand.We then reviewed patients’electronic health records(EHR)for demographic characteristics,history,physical examination findings,ED course,additional imaging studies,consultations,impact of POCUS on patient care and final disposition.RESULTS:We included a total of 50 cases(28 male,22 female)in the final analysis.The most common presenting symptoms and exam findings were pain(100%),swelling(90%),and erythema(74%).The most common sonographic findings were edema(76%),soft tissue swelling(78%),and fluid surrounding the tendon(57%).POCUS was used in medical decision making 68%of the time(n=34),with the use of POCUS leading to changes in management 38%of the time(n=19).POCUS use led to early antibiotic use(11/19),early consultation(10/19),and led to the performance of a required procedure(8/19).The POCUS diagnosis was consistent with the discharge diagnosis of flexor tenosynovitis 8/12 times,abscess 12/16 times,and cellulitis 14/20 times.CONCLUSION:POCUS is beneficial for evaluating of hand infections that present to the ED and can be used as an important part of medical decision making to expedite patient care. 展开更多
关键词 ultrasound Point-of-care ultrasound CELLULITIS ABSCESS Flexor tenosynovitis
下载PDF
Pictorial review of hepatic echinococcosis:Ultrasound imaging and differential diagnosis
18
作者 Yi Tao Yi-Fei Wang +4 位作者 Jun Wang Shuang Long Barnabas C Seyler Xiao-Fei Zhong Qiang Lu 《World Journal of Gastroenterology》 SCIE CAS 2024年第37期4115-4131,共17页
Echinococcosis is a zoonotic disease caused by parasites belonging to the genus Echinococcus that primarily affect the liver.The western plateau and pastoral areas of China are high-risk regions for hepatic cystic ech... Echinococcosis is a zoonotic disease caused by parasites belonging to the genus Echinococcus that primarily affect the liver.The western plateau and pastoral areas of China are high-risk regions for hepatic cystic echinococcosis and hepatic alveolar echinococcosis(HAE).The high late mortality rate associated with HAE underscores the critical need for early diagnosis to improve cure rates and mitigate the disease burden in endemic areas.Currently,the World Health Orga-nization recommends ultrasonography as the preferred initial screening method for hepatic echinococcosis.However,distinguishing between specific types of lesions,such as those of hepatic cystic echinococcosis and HAE,and other focal liver lesions is challenging.To address this issue,contrast-enhanced ultrasound is recommended as a tool to differentiate solid and cysto-solid hepatic echino-coccosis from other focal liver lesions,significantly enhancing diagnostic accuracy.In this comprehensive review,we discuss the progression of hepatic echinococcosis and detail the imaging features of various types of echinococcosis using conventional,contrast-enhanced,and intraoperative ultrasound techniques.Our objective is to provide robust imaging evidence and guidance for early diagnosis,clinical decision making,and postoperative follow-up in regions with high disease prevalence. 展开更多
关键词 ECHINOCOCCOSIS Zoonotic disease ultrasound Contrast-enhanced ultrasound DIAGNOSIS
下载PDF
Effect of Low-Intensity Pulsed Ultrasound on Ischaemic Heart Disease Patients (Novel Technique)
19
作者 Shaza Alturifi Mhd Firas Al Hinnawi +1 位作者 Ali Khaddam Ahmad Al Khaddour 《World Journal of Cardiovascular Surgery》 2021年第3期21-28,共8页
Ischaemic Heart Disease (IHD) or Coronary heart disease means that the heart is not getting enough blood and oxygen supply through the coronary arteries. The most common cause of this disease is the process of atheros... Ischaemic Heart Disease (IHD) or Coronary heart disease means that the heart is not getting enough blood and oxygen supply through the coronary arteries. The most common cause of this disease is the process of atherosclerosis in the coronary arteries. Although significant progress has been made in the management of ischaemic heart disease (IHD) The number of severe IHD patients is increasing. The treatment options for IHD <span lang="EN-US" style="font-family:Verdana;">have</span><span lang="EN-US" style="font-family:Verdana;"> not changed much over the last three decades</span><span lang="EN-US" style="font-family:Verdana;">,</span><span lang="EN-US" style="font-size:10pt;font-family:""> </span><span lang="EN-US" style="font-family:Verdana;">w</span><span lang="EN-US" style="font-family:Verdana;">hich </span><span lang="EN-US" style="font-family:Verdana;">is </span><span lang="EN-US" style="font-family:Verdana;">divided between medications, coronary Angioplasty and Coronary artery bypass surgery. Thus it was crucial to develop new, non-invasive therapeutic strategies in case of Failure of medical or interventional therapy or in case patient is not fit for surgery or angioplasty. In this study</span><span lang="EN-US" style="font-family:Verdana;">,</span><span lang="EN-US" style="font-family:Verdana;"> we are pleased to reveal a novel technique </span><span lang="EN-US" style="font-family:Verdana;">that</span><span lang="EN-US" style="font-family:Verdana;"> was carried out on </span><span lang="EN-US" style="font-family:Verdana;">a </span><span lang="EN-US" style="font-family:Verdana;">human model. We aimed to develop low-intensity pulsed ultrasound (LIPUS) therapy for the treatment of patients with Ischaemic Heart Disease. We have set up the inclusion and exclusion criteria, the treatment protocol of LIPUS on IHD patients. In this limited group of IHD patients, We found promising clinical results and improvement on myocardial functions.</span> 展开更多
关键词 Ischaemic Heart Disease (IHD) low-intensity Pulsed ultrasound (LIPUS)
下载PDF
The Effect of Material Surface Microstructure on the Enhancement of Bone-Bonding Ability of a Hydroxyapatite-Implant by Low-Intensity Pulsed Ultrasound (LIPUS)
20
作者 Masanori Kobayashi 《Materials Sciences and Applications》 2021年第1期42-51,共10页
Excellent firm bonding between the biomaterials and bone tissue (osseointegration and osteo-conductivity) has been desired for the stability in vivo of dental implants and artificial joints. Much has been learned abou... Excellent firm bonding between the biomaterials and bone tissue (osseointegration and osteo-conductivity) has been desired for the stability in vivo of dental implants and artificial joints. Much has been learned about this concept, which has led to significant improvements in the design and surface modification of implants in the field of implant dentistry, orthopedic surgery. We have already reported that low-intensity pulsed ultrasound (LIPUS) irradiation can accelerate the bone bonding ability of the bio-conductive materials such as bioactive titanium and hydroxyapatite implant. However, it is still unclear whether the LIPUS could have same effect to different types of the bioactive-materials. Therefore, in this study, the differences of bone-like hydroxyapatite formation on some kind of hydroxyapatite surface in simulated body fluid (SBF) under the LIPUS irradiation were investigated. Two kinds of hydroxyapatite samples immersed in SBF was exposed to ultrasound waves, the bone-like apatite on the surface was analyzed by Scanning electron microscopy and X-ray diffraction. As a result, the enhancement of hydroxyapatite formation on the surface by LIPUS was confirmed, the initial epitaxial nucleation and crystal growth of apatite depended on crystal structure of the surface of matrix materials. 展开更多
关键词 low-intensity Pulsed ultrasound (LIPUS) Simulated Body Fluid (SBF) Hydroxyapatite (HA) OSSEOINTEGRATION Osteo-Conductivity
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部