Evaluation of the intraoperative trauma degree and postoperative speech function of low-temperature plasma radiofrequency surgery treatment of children with OSAHS 被引量:1
1
作者 He Liu Liang Ma Zhong-Wu Sun 《Journal of Hainan Medical University》 2017年第9期70-74,共5页
Objective:To evaluate the intraoperative trauma degree and postoperative speech function of low-temperature plasma radiofrequency surgery treatment of children with obstructive sleep apnea hypopnea syndrome (OSAHS).Me... Objective:To evaluate the intraoperative trauma degree and postoperative speech function of low-temperature plasma radiofrequency surgery treatment of children with obstructive sleep apnea hypopnea syndrome (OSAHS).Methods: A total of 118 children with OSAHS were divided into the control group (n=59) who received general surgery and the observation group (n=59) who received the low-temperature plasma radiofrequency surgery according to the random number table. Before operation and 24 h after operation, serum levels of stress hormones, acute phase proteins and inflammatory markers of two groups of children were determined, and the speech function parameter levels were assessed.Results:Before operation, differences in serum contents of stress hormones, acute phase proteins and inflammatory factors as well as speech function parameter levels were not statistically significant between two groups of patients. 24 h after operation, serum stress hormones adrenocorticotropic hormone (ACTH), angiotensin-2 (Ang-2), norepinephrine (NE), cortisol (Cor) contents of observation group were lower than those of control group, serum acute phase proteins haptoglobin (HP), ceruloplasmin (CER), and prealbumin (PA) contents were lower than those of control group, and serum inflammatory factors interleukin-1 (IL-1), interleukin-4 (IL-4), interleukin-27 (IL-27), tumor necrosis factorα(TNF-α) contents were lower than those of control group;speech function parameters NNE and NHR levels of observation group were higher than those of control group.Conclusion:Compared with routine surgery, low-temperature plasma radiofrequency surgery treatment of children with OSAHS causes less surgical trauma and more greatly improves the postoperative speech level. 展开更多
关键词 OBSTRUCTIVE sleep apnea-hypopnea syndrome low-temperature plasma radiofrequency TRAUMA DEGREE Speech function
下载PDF
Experimental Research of Inactivation Effect of Low-Temperature Plasma on Bacteria 被引量:10
2
作者 石兴民 袁育康 +3 位作者 孙岩洲 袁网 彭风玲 邱毓昌 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第5期569-572,共4页
The killing logarithms index in killing a vegetative form in an explosure of about 90s and a spore in an explosure of about 120s, by using a low-temperature plasma produced by dielectric barrier discharge (DBD), rea... The killing logarithms index in killing a vegetative form in an explosure of about 90s and a spore in an explosure of about 120s, by using a low-temperature plasma produced by dielectric barrier discharge (DBD), reached 5. The speed in killing the strains tested, by using a low-temperature plasma, was the highest with E. Coli, then S. Aureus and B. Subtilis var niger spore. The results of the scanning electron microscope showed that the low-temperature plasma destroyed the outer structure of the bacteria and that the vegetative form was more susceptible to the inactivation effect of the low-temperature plasma than was the spore. This indicated that the effects of the high voltage and high velocity particle flow, in plasma, penetrating through the outer structure of the bacteria might play a dominant role during the inactivation of the bacteria. 展开更多
关键词 dielectric barrier discharge low-temperature plasma vegetative form SPORE
下载PDF
Surface Modification of Polyvinylidene Fluoride (PVDF) Membranes by Low-Temperature Plasma with Grafting Styrene 被引量:3
3
作者 陈剑 李继定 陈翠仙 《Plasma Science and Technology》 SCIE EI CAS CSCD 2009年第1期42-47,共6页
In order to control the surface pore sizes of polyvinylidene fluoride membranes and their distribution, low temperature plasma-induced grafting modifications of PVDF were studied to prepare hydrophobe membranes. By ar... In order to control the surface pore sizes of polyvinylidene fluoride membranes and their distribution, low temperature plasma-induced grafting modifications of PVDF were studied to prepare hydrophobe membranes. By argon (Ar) treating and subsequent grafting reaction, a hydrophobe monomer, styrene, was introduced into the PVDF membrane. Fourier transform infrared attenuated total reflection (FTIR-ATR) was utilized to characterize the chemical and physical changes in the Ar plasma modified membrane. The surface modifications of PVDF membranes were investigated by using scanning electron microscopy (SEM), atomic force microscopy (AFM) and differential scanning calorimeter (DSC). The water permeability and the solute rejection were measured by PVDF membrane modified in different graft conditions. Results demonstrated that the pores in the modified membranes get smaller and the distribution of pores gets narrowed with the increase in grafting reaction duration. Longer graft time caused the water flux of PVDF membrane to decrease from 578 kg/(m^2· h) to 23 kg/(m^2· h) and the solute rejection to increase from 73% to 92%. 展开更多
关键词 Ar low-temperature plasma surface grafting STYRENE PVDF membrane
下载PDF
Low-temperature Plasma Promotes Fibroblast Proliferation in Wound Healing by ROS-activated NF-κB Signaling Pathway 被引量:3
4
作者 石兴民 许桂敏 +6 位作者 张冠军 刘进仁 吴月明 高菱鸽 杨阳 常正实 姚聪伟 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2018年第1期107-114,共8页
Low-temperature plasma(LTP) has shown great promise in wound healing,although the underlying mechanism remains poorly understood.In the present study,an argon atmospheric pressure plasma jet was employed to treat L9... Low-temperature plasma(LTP) has shown great promise in wound healing,although the underlying mechanism remains poorly understood.In the present study,an argon atmospheric pressure plasma jet was employed to treat L929 murine fibroblasts cultured in vitro and skin wounds in BALB/c mice.The in vitro analysis revealed that treatment of fibroblasts with LTP for 15 s resulted in a significant increase in cell proliferation,secretion of epidermal growth factor(EGF) and transforming growth factor-β1(TGF-β1),production of intracellular reactive oxygen species(ROS),and the percentage of cells in S phase,protein expression of phosphorylated p65(P-p65) and cyclin D1,but a noted decrease in the protein expression of inhibitor kappa B(IκB).The in vivo experiments demonstrated that 30-s LTP treatment enhanced the number of fibroblasts and the ability of collagen synthesis,while 50-s treatment led to the opposite outcomes.These results suggested that LTP treatment promotes the fibroblast proliferation in wound healing by inducing the generation of ROS,upregulating the expression of P-p65,downregulating the expression of IκB,and activating the NF-κB signaling pathway and consequently altering cell cycle progression(increased DNA synthesis in S phage). 展开更多
关键词 low-temperature plasma fibroblast proliferation NF-κB signaling pathway cell cycle reactive oxygen species
下载PDF
Sensitivity of two drug-resistant bacteria to low-temperature air plasma in catheterassociated urinary tract infections under different environments 被引量:1
5
作者 何媛媛 丁呈彪 +5 位作者 金涛 范玥瑶 吴征威 孙梦雯 王琨 纪拓 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第6期137-143,共7页
The high incidence of catheter-associated urinary tract infections,which are dominated by drugresistant bacteria,has attracted an increasing number of researchers interested in solving this public health problem.The p... The high incidence of catheter-associated urinary tract infections,which are dominated by drugresistant bacteria,has attracted an increasing number of researchers interested in solving this public health problem.The purpose of this study was to explore the killing effect of lowtemperature air plasma(LTAP)on extended-spectrum beta-lactamase-producing Escherichia coli and high level gentamycin resistance enterococci under two simulated environments in vitro.The results showed that the survival rate of these two kinds of bacteria decreased to less than20%after being treated by LTAP in different environments for 5 min.A comparison of the LTAP treatments showed that the killing efficacy of the two kinds of bacteria in the early stage(0-1 min)was up to 50%.Moreover,the results of transmission electron microscopy,reactive nitrogen species measurement,and a temperature test indicated that the bactericidal effect of the LTAP treatment on the two kinds of bacteria worked through the destruction of the ribosome and other organelles inside the bacteria,rather than the thermal effect,to achieve sterilization. 展开更多
关键词 CAUTI low-temperature air plasma ANTIBACTERIAL transmission electron microscopy
下载PDF
Destruction of Gaseous Styrene with a Low-Temperature Plasma Induced by a Tubular Multilayer Dielectric Barrier Discharge 被引量:3
6
作者 张家辉 刘娟娟 +3 位作者 张仁熙 侯惠奇 陈善平 张益 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第1期50-55,共6页
The destruction of gaseous styrene was studied using a low-temperature plasma induced by tubular multilayer dielectric barrier discharge(DBD).The results indicate that the applied voltage,gas flow rate,inlet styrene... The destruction of gaseous styrene was studied using a low-temperature plasma induced by tubular multilayer dielectric barrier discharge(DBD).The results indicate that the applied voltage,gas flow rate,inlet styrene concentration and reactor configuration play important roles in styrene removal efficiency (ηstyrene) and energy yield(EY).Values of ηstyrene and EY reached 96%and 15567 mg/kWh when the applied voltage,gas flow rate,inlet styrene concentration and layers of quartz tubes were set at 10.8 kV,5.0 m/s,229 mg/m^3 and 5 layers,respectively.A qualitative analysis of the byproducts and a detailed discussion of the reaction mechanism are also presented.The results could facilitate industrial applications of the new DBD reactor for waste gas treatment. 展开更多
关键词 low-temperature plasma styrene dielectric barrier discharge(DBD)
下载PDF
Remove of Phenolic Compounds in Water by Low-Temperature Plasma: A Review of Current Research 被引量:1
7
作者 Jufang ZHANG Jierong CHEN Xiaoyong LI 《Journal of Water Resource and Protection》 2009年第2期99-109,共11页
Phenolic compounds have very strong toxicity, so it has been paid sharply attention to find an effective way of controlling the wastewater containing phenolic compounds. The work on this subject done by domestic and o... Phenolic compounds have very strong toxicity, so it has been paid sharply attention to find an effective way of controlling the wastewater containing phenolic compounds. The work on this subject done by domestic and overseas scholars is studied in this paper, and the progress of researches on low-temperature plasma treatment is summarized through the electrical discharge types, mechanism, kinetics of phenolic compounds decomposition and combination of several methods with low-temperature plasma treatment. In addition, the crucial problem and the developing tendency on low-temperature plasma treatment for phenol-bearing wastewater are briefly discussed. 展开更多
关键词 low-temperature plasma Treatment PHENOLIC COMPOUNDS Types of Electrical DISCHARGE Mechanism Kinetics Combination of SEVERAL Methods
下载PDF
Effectiveness of Radiofrequency Inductively Coupled Plasma Sources for Space Propulsion 被引量:1
8
作者 V. A. Riaby P E. Masherov +1 位作者 V. A. Obukhov V. P. Savinov 《高电压技术》 EI CAS CSCD 北大核心 2013年第9期2077-2088,共12页
Evolution of geometric forms of antenna coils for radiofrequency(RF)inductively coupled plasma(ICP)sources is analyzed.Top effectiveness of flat ICPSs generating plasma"tablet"is shown.Especially effective a... Evolution of geometric forms of antenna coils for radiofrequency(RF)inductively coupled plasma(ICP)sources is analyzed.Top effectiveness of flat ICPSs generating plasma"tablet"is shown.Especially effective are ICPSs using antenna coils enhanced with ferromagnetic cores(FMICPS).It is found that the design of flat ICPSs is simpler and more convenient for the arrangement of plasma diagnostics in comparison with ICPSs of other geometries.Effective flat FMICPS models of different diameters ranging from 10 cm to 100cm are considered.Recommendations are given for development engineers dealing with ICPS devices in general and with radio frequency ion thrusters(RITs)in particular. 展开更多
关键词 电感耦合等离子体 等离子体源 空间推进 射频 等离子体诊断 几何形式 ICPS 离子推进器
下载PDF
Dielectric barrier discharge plasma-assisted catalytic ammonia synthesis:synergistic effect of Ni-MOF-74 catalyst and nanosecond pulsed plasma
9
作者 徐晓芳 孙萌 +4 位作者 宋勤龙 吴璇 陈冲冲 陈强 张海宝 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第6期40-49,共10页
Ammonia is one of the most important chemical raw materials in both manufacture and life of human.Traditionally Haber-Bosch method for ammonia synthesis involves high temperature and high pressure conditions,leading t... Ammonia is one of the most important chemical raw materials in both manufacture and life of human.Traditionally Haber-Bosch method for ammonia synthesis involves high temperature and high pressure conditions,leading to significant energy consumption and environmental pollution.Non-thermal plasma(NTP) is a promising alternative approach to ammonia synthesis at low temperature and atmospheric pressure.In this study,the synergistic effect of nanosecond pulsed dielectric barrier discharge(np-DBD) and Ni-MOF-74 catalyst was investigated in ammonia synthesis by utilizing nitrogen and hydrogen as feedstock.The results demonstrated that the plasma catalytic-synthesis process parameters play a crucial role in the synthesis process of ammonia.The highest ammonia synthesis rate of 5145.16 μmol·g^(-1)·h^(-1)with an energy efficiency of 1.27 g·kWh^(-1)was observed in the presence of the Ni-MOF-74 catalyst,which was3.7 times higher than that without Ni-MOF-74 catalyst.The synergistic effect of Ni-MOF-74catalyst and nanosecond pulsed plasma was explored by in-situ plasma discharge diagnostics. 展开更多
关键词 AMMONIA SYNTHESIS low-temperature plasma nanosecond pulsed power source Ni-MOF-74
下载PDF
Enhancing CO_(2) transport with plasma-functionalized ionic liquid membranes
10
作者 舒茹晨 许卉 +5 位作者 裴晨霄 王楠 刘新刚 侯剑源 袁圆 张仁熙 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期74-81,共8页
The ionic liquid(IL) 1-butyl-3-methylimidazolium tetrafluoroborate treated with radiofrequency plasma is proposed for functionalization and immobilization on polyethersulfone supports to form supported ionic liquid me... The ionic liquid(IL) 1-butyl-3-methylimidazolium tetrafluoroborate treated with radiofrequency plasma is proposed for functionalization and immobilization on polyethersulfone supports to form supported ionic liquid membranes for CO_(2) separation.The effects of treatment time and transmembrane pressure difference on CO_(2) permeance were evaluated.The best gas permeation performance was obtained with a treatment time of 10 min and the transmembrane pressure difference was 0.25 MPa.Characterization of the materials by Fourier transform infrared spectroscopy,x-ray photoelectron spectroscopy and nuclear magnetic resonance spectroscopy demonstrates that the IL is grafted with carboxyl groups and deprotonated through plasma treatment.A preliminary mechanism for the plasma treatment and facilitated transport of CO_(2)has been proposed on this basis. 展开更多
关键词 ionic liquids carbon dioxide supported ionic liquid membranes facilitated transport radiofrequency plasma
下载PDF
Design and characteristics investigation of a miniature low-temperature plasma spark discharge device
11
作者 李雪 周仁武 +3 位作者 张波 周儒森 Ken OSTRIKOV 方志 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第5期43-50,共8页
Atmospheric pressure low-temperature plasma is a promising tool in biomedicine applications including blood coagulation,bacterial inactivation,sterilization,and cancer treatment,due to its high chemical activity and l... Atmospheric pressure low-temperature plasma is a promising tool in biomedicine applications including blood coagulation,bacterial inactivation,sterilization,and cancer treatment,due to its high chemical activity and limited thermal damage.It is of great importance to develop portable plasma sources that are safe to human touch and suitable for outdoor and household operation.In this work,a portable and rechargeable low-temperature plasma spark discharge device(130 mm×80 mm×35 mm,300 g)was designed.The discharge frequency and plume length were optimized by the selection of resistance,capacitance,electrode gap,and ground electrode aperture.Results show that the spark plasma plume is generated with a length of 12 mm and a frequency of 10 Hz at a capacitance of 0.33μF.resistance of 1 MΩ,electrode gap of 2 mm,and ground electrode aperture of 1.5 mm.Biological tests indicate that the plasma produced by this device contains abundant reactive species,which can be applied in plasma biomedicine,including daily sterilization and wound healing. 展开更多
关键词 low-temperature plasma SPARK DISCHARGE portable plasma source plasma MEDICINE
下载PDF
Continuous Emission Spectrum Measurement for Electron Temperature Determination in Low-Temperature Collisional Plasmas
12
作者 刘秋艳 李弘 +2 位作者 陈志鹏 谢锦林 刘万东 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第4期451-457,共7页
Continuous emission spectrum measurement is applied for the inconvenient diagnos- tics of low-temperature collisional plasmas. According to the physical mechanism of continuous emission, a simplified model is presente... Continuous emission spectrum measurement is applied for the inconvenient diagnos- tics of low-temperature collisional plasmas. According to the physical mechanism of continuous emission, a simplified model is presented to analyze the spectrum in low temperature plasma. The validity of this model is discussed in a wide range of discharge parameters, including electron tem- perature and ionization degree. Through the simplified model, the continuous emission spectrum in a collisional argon internal inductively coupled plasma is experimentally measured to determine the electron temperature distribution for different gas pressures and radio-frequency powers. The inverse Abel transform is also applied for a better spatially resoluted results. Meanwhile, the result of the continuous emission spectrum measurement is compared to that of the electrostatic double probes, which indicates the effectiveness of this method. 展开更多
关键词 continuous emission spectrum DIAGNOSTICS low-temperature plasma colli- sional plasma
下载PDF
Perioperative Nursing Observation of Plasma Radiofrequency Ablation for Treatment of Lumbar Intervertebral Disc Herniation 被引量:1
13
作者 Hui Sun Guo Tang +1 位作者 Dan Li Lei Wang 《Journal of Clinical and Nursing Research》 2021年第3期28-33,共6页
Objective:To observe and analyze the perioperative nursing effect of plasma radiofrequency ablation for treatment of lumbar disc herniation.Methods:A total of 100 patients with lumbar intervertebral disc herniation re... Objective:To observe and analyze the perioperative nursing effect of plasma radiofrequency ablation for treatment of lumbar disc herniation.Methods:A total of 100 patients with lumbar intervertebral disc herniation received from October 2017 to October 2020 were selected and randomly divided into two groups with 50 cases in each group.The control group received the conventional nursing model and the experimental group received the comprehensive nursing model.The two groups of nursing care were compared on satisfaction,SDS and SAS scores before and after treatment,VAS score and JOA score before and after treatment,and treatment effect.Results:The nursing satisfaction of the experimental group,SDS and SAS scores before and after treatment,VAS score and JOA score before and after treatment,and the treatment effect were better than those of the control group.The difference was statistically significant(P<0.05).Conclusion:The comprehensive nursing model has a significant effect on the perioperative nursing of the treatment of lumbar intervertebral disc herniation by plasma radiofrequency ablation.More popularization and application will help improve the treatment effect. 展开更多
关键词 Comprehensive nursing Lumbar disc herniation plasma radiofrequency ablation
下载PDF
The Feasibility of Applying AC Driven Low-Temperature Plasma for Multi-Cycle Detonation Initiation
14
作者 郑殿峰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第11期1110-1115,共6页
Ignition is a key system in pulse detonation engines (PDE). As advanced ignition methods, nanosecond pulse discharge low-temperature plasma ignition is used in some combustion systems, and continuous alternating cur... Ignition is a key system in pulse detonation engines (PDE). As advanced ignition methods, nanosecond pulse discharge low-temperature plasma ignition is used in some combustion systems, and continuous alternating current (AC) driven low-temperature plasma using dielectric barrier discharge (DBD) is used for the combustion assistant. However, continuous AC driven plasmas cannot be used for ignition in pulse detonation engines. In this paper, experimental and numerical studies of pneumatic valve PDE using an AC driven low-temperature plasma igniter were described. The pneumatic valve was jointly designed with the low-temperature plasma igniter, and the numerical simulation of the cold-state flow field in the pneumatic valve showed that a complex flow in the discharge area, along with low speed, was beneficial for successful ignition. In the experiments ethylene was used as the fuel and air as oxidizing agent, ignition by an AC driven low-temperature plasma achieved multi-cycle intermittent detonation combustion on a PDE, the working frequency of the PDE reached 15 Hz and the peak pressure of the detonation wave was approximately 2.0 MPa. The experimental verifications of the feasibility in PDE ignition expanded the application field of AC driven low-temperature plasma. 展开更多
关键词 pulse detonation engine low-temperature plasma IGNITION detonation combustion
下载PDF
Interaction of supersonic molecular beam with low-temperature plasma
15
作者 刘东 曲国峰 +13 位作者 王占辉 王华杰 刘灏 王艺舟 徐子虚 李敏 杨朝文 刘星泉 林炜平 颜敏 黄宇 朱宇轩 许敏 韩纪锋 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第6期349-357,共9页
The interaction between the supersonic molecular beam(SMB)and the low-temperature plasma is a critical issue for the diagnosis and fueling in the Tokamak device.In this work,the interaction process between the argon S... The interaction between the supersonic molecular beam(SMB)and the low-temperature plasma is a critical issue for the diagnosis and fueling in the Tokamak device.In this work,the interaction process between the argon SMB and the argon plasma is studied by a high-speed camera based on the Linear Experimental Advanced Device(LEAD)in Southwestern Institute of Physics,China.It is found that the high-density SMB can extinct the plasma temporarily and change the distribution of the plasma density significantly,while the low-density SMB can hardly affect the distribution of plasma density.This can be used as an effective diagnostic technique to study the evolution of plasma density in the interaction between the SMB and plasma.Moreover,the related simulation based on this experiment is carried out to better understand the evolution of electron density and ion density in the interaction.The simulation results can be used to analyze and explain the experimental results well. 展开更多
关键词 supersonic molecular beam low-temperature plasma EMISSION electron density diagnosis highspeed camera
下载PDF
Plasma-assisted surface treatment for low-temperature annealed ohmic contact on AlGaN/GaN heterostructure field-effect transistors
16
作者 王磊 张家琦 +2 位作者 李柳暗 前田裕太郎 敖金平 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第3期474-477,共4页
In this study, a low-temperature annealed ohmic contact process was proposed on AlGaN/GaN heterostructure field effect transistors (HFETs) with the assistance of inductively coupled plasma (ICP) surface treatment.... In this study, a low-temperature annealed ohmic contact process was proposed on AlGaN/GaN heterostructure field effect transistors (HFETs) with the assistance of inductively coupled plasma (ICP) surface treatment. The effect of ICP treatment process on the 2DEG channel as well as the formation mechanism of the low annealing temperature ohmic contact was investigated. An appropriate residual AlGaN thickness and a plasma-induced damage are considered to contribute to the low-temperature annealed ohmic contact. By using a single Al layer to replace the conventional Ti/Al stacks, ohmic contact with a contact resistance of 0.35 Ω.mm was obtained when annealed at 575 ℃ for 3 min. Good ohmic contact was also obtained by annealing at 500 ℃ for 20 rain. 展开更多
关键词 AlGaN/GaN HFET low-temperature ohmic contact inductively coupled plasma (ICP) surfacetreatment
下载PDF
Application of persulfate in low-temperature atmospheric-pressure plasma jet for enhanced treatment of onychomycosis
17
作者 张群霞 方草 +1 位作者 陈祝 黄青 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第2期87-94,共8页
Fungal infection of human nails,or onychomycosis,affects 10%of the world's adult population,but current therapies have various drawbacks.In this work,we employed a self-made low-temperature plasma(LTP)device,namel... Fungal infection of human nails,or onychomycosis,affects 10%of the world's adult population,but current therapies have various drawbacks.In this work,we employed a self-made low-temperature plasma(LTP)device,namely,an atmospheric-pressure plasma jet(APPJ)device to treat the nails infected with Trichophyton rubrum(T.rubrum)with the aid of persulfate solution.We found that persulfate solution had a promoting effect on plasma treatment of onychomycosis.With addition of sodium persulfate,the APPJ therapy could cure onychomycosis after several times of treatment.As such,this work has demonstrated a novel and effective approach which makes good use of LTP technique in the treatment of onychomycosis. 展开更多
关键词 low-temperature plasma(LTP) PERSULFATE ONYCHOMYCOSIS Trichophyton rubrum(T rubrum)
下载PDF
Progress of International Low-Temperature Plasma Research──Overview of the 15th International Symposium on Plasma Chemistry
18
作者 吴承康 《Plasma Science and Technology》 SCIE EI CAS CSCD 2001年第6期1011-1018,共8页
International Symposium on Plasma Chemistry (ISPC) is the most influencial in- ternational symposium on science and technology research of low-temperature plasma, especially in the fields related to materials processi... International Symposium on Plasma Chemistry (ISPC) is the most influencial in- ternational symposium on science and technology research of low-temperature plasma, especially in the fields related to materials processing. People can be rightly informed of the current devel- oping trend of this field from the contents of these symposia. This paper will introduce briefly a general overview of the 15th ISPC. As viewed from the number of papers and their contents, there is still abundant research on thermal plasma, and the needs fOr micro-electronic technology and high performance films have driven forward continuous and intensive development of the research on low-pressure, non-equilibrium plasmas, while the research on normal pressure, non-equilibrium plasma has become a new highlight in this field. 展开更多
关键词 In Overview of the 15th International Symposium on plasma Chemistry Progress of International low-temperature plasma Research
下载PDF
Assessment of the intraoperative wound degree as well as postoperative immune function and ventilation function of plasma radiofrequency ablation for the treatment of adenoid hypertrophy
19
作者 He Liu Liang Ma Zhong-Wu Sun 《Journal of Hainan Medical University》 2017年第8期71-74,共4页
Objective:To study the intraoperative wound degree as well as postoperative immune function and ventilation function of plasma radiofrequency ablation for the treatment of adenoid hypertrophy.Methods: A total of 118 c... Objective:To study the intraoperative wound degree as well as postoperative immune function and ventilation function of plasma radiofrequency ablation for the treatment of adenoid hypertrophy.Methods: A total of 118 children with adenoid hypertrophy who underwent surgical treatment in our hospital between May 2013 and April 2016 were selected and divided into the control group (n=59) who accepted conventional endoscopic cutting aspirator and the observation group (n=59) who accepted the plasma radiofrequency ablation according to the single-blind randomized controlled method. Before and after operation, the levels of peripheral blood trauma-related indexes, humoral immunity and complement indexes as well as nasal ventilation function indexes were determined.Results:Before operation, the differences in trauma-related indexes, humoral immunity and complement indexes as well as nasal ventilation function indexes were not statistically significant between two groups of children. Immediately after operation, the peripheral blood SP, PGE2 and CRP contents of observation group were lower than those of control group;24 h after operation, peripheral blood IgG, IgM, IgA, C3 and C4 contents of observation group were lower than those of control group;1 week after operation, TIR and TER levels of observation group were lower than those of control group while NPV and MCSA levels were higher than those of control group.Conclusion:Plasma radiofrequency ablation for treatment of adenoid hypertrophy causes smaller intraoperative wound and has more advantages in optimizing the body's immune function and ventilation function. 展开更多
关键词 ADENOID HYPERTROPHY plasma radiofrequency ablation WOUND DEGREE Immune FUNCTION Ventilation FUNCTION
下载PDF
Management of Barrett’s esophagus with dysplasia refractory to radiofrequency ablation 被引量:2
20
作者 Kara L Raphael Arvind J Trindade 《World Journal of Gastroenterology》 SCIE CAS 2020年第17期2030-2039,共10页
Radiofrequency ablation(RFA)is very effective for eradication of flat Barrett’s mucosa in dysplastic Barrett’s esophagus after endoscopic resection of raised lesions.However,in a minority of the time,RFA may be inef... Radiofrequency ablation(RFA)is very effective for eradication of flat Barrett’s mucosa in dysplastic Barrett’s esophagus after endoscopic resection of raised lesions.However,in a minority of the time,RFA may be ineffective at eradication of the Barrett’s mucosa.Achieving complete eradication of intestinal metaplasia can be challenging in these patients.This review article focuses on the management of patients with dysplastic Barrett’s esophagus refractory to RFA therapy.Management strategies discussed in this review include optimizing the RFA procedure,optimizing acid suppression(with medical,endoscopic,and surgical management),cryotherapy,hybrid argon plasma coagulation,and EndoRotor resection. 展开更多
关键词 Low-grade DYSPLASIA HIGH-GRADE DYSPLASIA radiofrequency ablation CRYOTHERAPY EndoRotor Hybrid ARGON plasma COAGULATION ARGON plasma COAGULATION
下载PDF
上一页 1 2 30 下一页 到第