With the huge rise of energy demand,the power system in the current era is moving to a new standard with increased access to renewable energy sources(RESs)integrated with distribution generation(DG)network.The RESs ne...With the huge rise of energy demand,the power system in the current era is moving to a new standard with increased access to renewable energy sources(RESs)integrated with distribution generation(DG)network.The RESs necessitate interfaces for controlling the power generation.The multilevel inverter(MLI)can be exploited for RESs in two diverse modes,namely,the power generation mode(stand-alone mode),and compensator mode(statcom).Few works have been carried out in optimization of controller gains with the load variations of the single type such as reactive load variation in different cases.Nevertheless,this load type may be unbalanced hence,to overcome such issues.So,a sophisticated optimization algorithm is important.This paper aims to introduce a control design via an optimization assisted PI controller for a 7-level inverter.In the present technique,the gains of the PI controller are adjusted dynamically by the adopted hybrid scheme,grey optimizer with dragon levy update(GD-LU),based on the operating conditions of the system.Here,the gains are adjusted such that the error between the reference signal and fault signal should be minimal.Thus,better dynamic performance could be attained by the present optimized PI controller.The proposed algorithm is the combined version of grey wolf optimization(GWO)and dragonfly algorithm(DA).Finally,the performance of the proposed work is compared and validated over other state-of-the-art models concerning error measures.展开更多
文摘With the huge rise of energy demand,the power system in the current era is moving to a new standard with increased access to renewable energy sources(RESs)integrated with distribution generation(DG)network.The RESs necessitate interfaces for controlling the power generation.The multilevel inverter(MLI)can be exploited for RESs in two diverse modes,namely,the power generation mode(stand-alone mode),and compensator mode(statcom).Few works have been carried out in optimization of controller gains with the load variations of the single type such as reactive load variation in different cases.Nevertheless,this load type may be unbalanced hence,to overcome such issues.So,a sophisticated optimization algorithm is important.This paper aims to introduce a control design via an optimization assisted PI controller for a 7-level inverter.In the present technique,the gains of the PI controller are adjusted dynamically by the adopted hybrid scheme,grey optimizer with dragon levy update(GD-LU),based on the operating conditions of the system.Here,the gains are adjusted such that the error between the reference signal and fault signal should be minimal.Thus,better dynamic performance could be attained by the present optimized PI controller.The proposed algorithm is the combined version of grey wolf optimization(GWO)and dragonfly algorithm(DA).Finally,the performance of the proposed work is compared and validated over other state-of-the-art models concerning error measures.