期刊文献+
共找到44,892篇文章
< 1 2 250 >
每页显示 20 50 100
Plasma nitrogen fixation system with dual-loop enhancement for improved energy efficiency and its efficacy for lettuce cultivation
1
作者 韩泽阳 张梦雪 +8 位作者 张頔 何欣 井天军 葛知轩 李玉鸽 朱童 任云鸿 仲崇山 季方 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第1期82-92,共11页
Plasma nitrogen fixation(PNF)has been emerging as a promising technology for greenhouse gasfree and renewable energy-based agriculture.Yet,most PNF studies seldom address practical application-specific issues.In this ... Plasma nitrogen fixation(PNF)has been emerging as a promising technology for greenhouse gasfree and renewable energy-based agriculture.Yet,most PNF studies seldom address practical application-specific issues.In this work,we present the development of a compact and automatic PNF system for on-site agricultural applications.The system utilized a gliding-arc discharge as the plasma source and employed a dual-loop design to generate NO_(x)from air and water under atmospheric conditions.Experimental results showed that the system with a dualloop design performs well in terms of energy costs and production rates.Optimal operational parameters for the system were determined through experimentation,resulting in an energy cost of 13.9 MJ mol^(-1)and an energy efficiency of 16 g kWh^(-1)for NO_(3)^(-)production,respectively.Moreover,the concentration of exhausted NO_(x)was below the emission standards.Soilless lettuce cultivation experiments demonstrated that NO_(x)^(-)produced by the PNF system could serve as liquid nitrate nitrogen fertilizer.Overall,our work demonstrates the potential of the developed PNF system for on-site application in the production of green-leaf vegetables. 展开更多
关键词 plasma nitrogen fixation gliding arc soilless cultivation LETTUCE
下载PDF
Microfluidic-oriented synthesis of enriched iridium nanodots/carbon architecture for robust electrocatalytic nitrogen fixation
2
作者 Hengyuan Liu Xingjiang Wu +2 位作者 Yuhao Geng Xin Li Jianhong Xu 《Green Energy & Environment》 SCIE EI CAS CSCD 2024年第3期544-555,共12页
Electrocatalytic nitrogen reduction reaction(NRR)is considered as a promising candidate to achieve ammonia synthesis because of clean electric energy,moderate reaction condition,safe operating process and harmless by-... Electrocatalytic nitrogen reduction reaction(NRR)is considered as a promising candidate to achieve ammonia synthesis because of clean electric energy,moderate reaction condition,safe operating process and harmless by-products.However,the chemical inertness of nitrogen and poor activated capacity on catalyst surface usually produce low ammonia yield and faradic efficiency.Herein,the microfluidic technology is proposed to efficiently fabricate enriched iridium nanodots/carbon architecture.Owing to in-situ co-precipitation reaction and microfluidic manipulation,the iridium nanodots/carbon nanomaterials possess small average size,uniform dispersion,high conductivity and abundant active sites,producing good proton activation and rapid electrons transmission and moderate adsorption/desorption capacity.As a result,the as-prepared iridium nanodots/carbon nanomaterials realize large ammonia yield of 28.73 μg h^(-1) cm^(-2) and faradic efficiency of 9.14%in KOH solution.Moreover,the high ammonia yield of 11.21 μg h^(-1) cm^(-2) and faradic efficiency of 24.30%are also achieved in H_(2)SO_(4) solution.The microfluidic method provides a reference for large-scale fabrication of nano-sized catalyst materials,which may accelerate the progress of electrocatalytic NRR in industrialization field. 展开更多
关键词 Iridium nanodots CARBON Microfluidic technology Efficient synthesis Electrocatalytic nitrogen fixation
下载PDF
Intermittent sliding-lock-knot suture for limbal conjunctival autograft fixation in pterygium surgery:a technique note
3
作者 Ling Zhang Run-Hua Lyu +3 位作者 Jing-Ru Wang Wen-Jian Shi Feng Zheng Ying-Ying Gao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期838-844,共7页
AIM:To report a technique used with intermittent slidinglock-knot(ISLK)fixation for limbal conjunctival autografts in pterygium surgery and compared with those of routine intermittent(RI)fixation.METHODS:Consecutive p... AIM:To report a technique used with intermittent slidinglock-knot(ISLK)fixation for limbal conjunctival autografts in pterygium surgery and compared with those of routine intermittent(RI)fixation.METHODS:Consecutive patients with primary pterygium who had undergone pterygium excision combined with limbal conjunctival autograft transplantation between March 2021 and March 2022 at our institute were retrospectively analyzed.Primary outcome measures were mean duration of surgery and suture removal,degree of conjunctival hyperemia on postoperative day 1,pain score at suture removal,postoperative symptoms at 6mo,including conjunctival hyperemia,foreign body sensation,and graft stability.RESULTS:Ninety-eight patients underwent monocular surgery and were divided into ISLK(51 eyes)and RI(47 eyes)groups according to the type of conjunctiva autograft fixation method planned.There was no significant difference in mean duration of surgery between the two groups(18.59±2.39min vs 18.15±2.20min,P=0.417);however,compared to the RI group,shorter suture removal times were observed in the ISLK group[0.58min(0.42-0.87)vs 3.00min(2.21-4.15),P<0.001].The degree of conjunctival hyperemia on postoperative day 1 was milder in the ISLK group(P<0.001).Pain scores at suture removal were lower in the ISLK group than in RI group[1(0-3)vs 2(1-4),P<0.001].Postoperative symptoms at 6mo were comparable between the groups(P=0.487),with no recurrence.CONCLUSION:ISLK is an innovative method for limbal conjunctival autograft fixation after pterygium excision.Compared to RI fixation,ISLK facilitates suture removal and reduces discomfort,with comparable surgery duration and less conjunctival hyperemia. 展开更多
关键词 intermittent sliding-lock-knot fixation pterygium suture removal
下载PDF
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
4
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
下载PDF
Health economics for intra-capsular hip fractures undertaking fixation
5
作者 Anatole Wiik Thomas Ashdown Ian Holloway 《World Journal of Orthopedics》 2024年第1期30-38,共9页
BACKGROUND Hip fracture is a common musculoskeletal injury in the elderly requiring surgery worldwide.The operative mainstay of intra-capsular hip fractures is arthroplasty with a smaller proportion for fixation.AIM T... BACKGROUND Hip fracture is a common musculoskeletal injury in the elderly requiring surgery worldwide.The operative mainstay of intra-capsular hip fractures is arthroplasty with a smaller proportion for fixation.AIM To determine the most beneficial method of fixation for patients with intracapsular hip fractures.METHODS A registered audit from 2012-2018 was conducted on all intra-capsular hip fractures treated with 2 commonly used fixation methods.Patient notes,electronic records and clinical codes for cost benefit were evaluated.A validated quality of life measure was collected at least 1 year after surgery.RESULTS A total of 83 patients were identified with intra-capsular fractures undergoing fixation during the retrospective period.There were 47 cannulated cancellous screw and 36 sliding hip screw fixations with the case mix comparable for age,gender,co-morbidities and fracture configuration.There was no significant difference in blood loss,tip apex distance,radiation exposure,length of stay,radiological union time,collapse,avascular necrosis or re-operation between fixation methods.Logistic regression analysis demonstrated displaced intracapsular hip fractures correlated significantly with an undesirable outcome conferring a relative odds ratio of 7.25.There were 9(19%)and 4(11%)patients respectively,who required re-operation.There was no significant difference in health resource group tariff and implant cost with comparable EQ-5D and visual CONCLUSION No significant advantage was identified with differing fixation type,but irrespective there were a high number of patients requiring re-operation.This was predicted by initial fracture displacement and patient age.Arthroplasty may need to be carefully considered for health economics and patient benefit. 展开更多
关键词 Hip fracture fixation Patient reported outcome measure COST
下载PDF
In vitro performance of a biodegradable zinc alloy adjustable-loop cortical suspension fixation for anterior cruciate ligament reconstruction
6
作者 Ting Wang Zhangzhi Shi +7 位作者 Hongyong Zhong Xiangmin Li Jinling Sun Wei Yin Xiaojing Ji Qiang Wang Anqi Zhao Luning Wang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期887-898,共12页
Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,part... Anterior cruciate ligament(ACL)injuries of the knee are one of the most common and serious athletic injuries.The widely used cortical suspension fixation buttons for ligament reconstruction are permanent implants,particularly those made from conventional steel or titanium alloys.In this study,a biodegradable Zn-0.45Mn-0.2Mg(ZMM42)alloy with the yield strength of 300.4 MPa and tensile strength of 329.8 MPa was prepared through hot extrusion.The use of zinc alloys in the preparation of cortical suspension fixation buttons was proposed for the first time.After 35 d of immersion in simulated body fluids,the ZMM42 alloy fixation buttons were degraded at a rate of 44μm/a,and the fixation strength was retained(379.55 N)in the traction loops.Simultaneously,the ZMM42 alloy fixation buttons exhibited an increase in MC3T3-E1 cell viability and high antibacterial activity against Escherichia coli and Staphylococcus aureus.These results reveal the potential of biodegradable zinc alloys for use as ligament reconstruction materials and for developing diverse zinc alloy cortical suspension fixation devices. 展开更多
关键词 anterior cruciate ligament reconstruction zinc alloy fixation buttons mechanical property corrosion behavior BIOCOMPATIBILITY
下载PDF
Lateral femoral tunnel preparation and graft fixation for anterior cruciate ligament reconstruction–A discussion
7
作者 Mehak Chandanani Andrea Volpin 《World Journal of Clinical Cases》 SCIE 2024年第17期3277-3280,共4页
This article provides a discussion and commentary around the recent advances in arthroscopic anterior cruciate ligament reconstruction(ACLR),with a focus on the aspects of lateral femoral tunnel preparation and graft ... This article provides a discussion and commentary around the recent advances in arthroscopic anterior cruciate ligament reconstruction(ACLR),with a focus on the aspects of lateral femoral tunnel preparation and graft fixation techniques.The paper explores and comments on a recently published review by Dai et al,titled"Research progress on preparation of lateral femoral tunnel and graft fixation in ACLR",while providing insight into its relevance within the field of ACLR,and recommendations for future research. 展开更多
关键词 Anterior cruciate ligament reconstruction Arthroscopic surgery Lateral femoral tunnel Graft fixation techniques Anterior cruciate ligament tear BIOMECHANICS Knee injuries
下载PDF
High piezo/photocatalytic efficiency of Ag/Bi_(5)O_(7)I nanocomposite using mechanical and solar energy for N2 fixation and methyl orange degradation 被引量:1
8
作者 Lu Chen Wenqian Zhang +6 位作者 Junfeng Wang Xiaojing Li Yi Li Xin Hu Leihong Zhao Ying Wu Yiming He 《Green Energy & Environment》 SCIE EI CSCD 2023年第1期283-295,共13页
In this work,Ag/Bi_(5)O_(7)I nanocomposite was prepared and firstly applied in piezo/photocatalytic reduction of N2 to NH3 and methyl orange(MO)degradation.Bi_(5)O_(7)I was synthesized via a hydrothermal-calcination m... In this work,Ag/Bi_(5)O_(7)I nanocomposite was prepared and firstly applied in piezo/photocatalytic reduction of N2 to NH3 and methyl orange(MO)degradation.Bi_(5)O_(7)I was synthesized via a hydrothermal-calcination method and shows nanorods morphology.Ag nanoparticles(NPs)were photo deposited on the Bi_(5)O_(7)I nanorods as electron trappers to improve the spatial separation of charge carriers,which was confirmed via XPS,TEM,and electronic chemical analyses.The catalytic test indicates that Bi_(5)O_(7)I presents the piezoelectric-like behavior,while the loading of Ag NPs can strengthen the character.Under ultrasonic vibration,the optimal Ag/Bi_(5)O_(7)I presents high efficiency in MO degradation.The degradation rate is determined to be 0.033 min1,which is 4.7 folds faster than that of Bi_(5)O_(7)I.The Ag/Bi_(5)O_(7)I also presents a high performance in piezocatalytic N2 fixation.The piezocatalytic NH3 generation rate reaches 65.4 μmol L^(-1)g^(-1)h^(-1)with water as a hole scavenger.The addition of methanol can hasten the piezoelectric catalytic reaction.Interestingly,when ultrasonic vibration and light irradiation simultaneously act on the Ag/Bi_(5)O_(7)I catalyst,higher performance in NH3 generation and MO degradation is observed.However,due to the weak adhesion of Ag NPs,some Ag NPs would fall off from the Bi_(5)O_(7)I surface under long-term ultrasonic vibration,which would greatly reduce the piezoelectric catalytic performance.This result indicates that a strong binding force is required when preparing the piezoelectric composite catalyst.The current work provides new insights for the development of highly efficient catalysts that can use multiple energies. 展开更多
关键词 Ag/Bi_(5)O_(7)I Piezocatalysis Photocatalysis N2 fixation MO degradation
下载PDF
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
9
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 Volar plate Internal fixation Closed reduction External fixation PLASTER SPLINT Distal radius fracture Meta analysis
下载PDF
Medium-term outcomes of laparoscopic pubocervical fascia reconstruction and sacrospinous ligament fixation with posterior approach for a pelvic organ prolapse:A retrospective study of 124 cases
10
作者 Yunshan Zhu Xiao Zhang +4 位作者 Danxia Chen Guangxiao Li Shanliang Shang Jianqiong Li Jianhua Yang 《Laparoscopic, Endoscopic and Robotic Surgery》 2023年第4期154-159,共6页
Objective:Pelvic organ prolapse(POP)is a common gynecological disease in middle-aged and older women that seriously affects patients'physical health and quality of life,increases the financial burden for patients,... Objective:Pelvic organ prolapse(POP)is a common gynecological disease in middle-aged and older women that seriously affects patients'physical health and quality of life,increases the financial burden for patients,and becomes a major public health concern.The aim of this study was to investigate the medium-term outcomes of laparoscopic pubocervical fascia reconstruction and sacrospinous ligament fixation with a posterior approach for patients with severe POP.Methods:Patients with severe POP quantitation stage III-IV who underwent laparoscopic pubocervical fascia reconstruction and sacrospinous ligament fixation with a posterior approach at the Department of Obstetrics and Gynecology,Sir Run Run Shaw Hospital,Zhejiang University School of Medicine between September 2016 and December 2020 were enrolled in this study.The results and complications were recorded.Data were retrospectively reviewed.Results:In total,124 patients were analyzed.Patients were followed up for 32.2712.90 months.The objective cure rate for patients who underwent hysterectomy was 917%(100/109),with 7(6.4%)patients had anterior vaginal wall prolapse and 2(1.8%)patients had posterior vaginal wall prolapse.The objective cure rate for patients who retained uterus was 66.7%(10/15).All 5 patients with recurrence had uterine prolapse,and 3(20.0%)of them also had anterior vaginal wall prolapse.Conchusions:Laparoscopic pubocervical fascia reconstruction and sacrospinous ligament fixation with the posterior approach is a safe,minimally invasive,and effective method for patients with severe POP.Long-term follow-up is needed to confirm the clinical effects. 展开更多
关键词 Pelvic organ prolapse LAPAROSCOPY Pubocervical fascia reconstruction Sacrospinous ligament fixation
下载PDF
Flapless one-knot suture:a novel surgical technique for transscleral fixation of C-loop intraocular lenses
11
作者 Qing-Qing Long Bao-Jiang Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第5期736-742,共7页
AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectiv... AIM:To describe a novel suture approach for transscleral fixation of C-loop intraocular lenses(IOL)and to compare the surgical outcomes with the four-haptics posterior chamber(PC)-IOL technique.METHODS:We retrospectively analyzed 16 eyes of 16 patients who underwent transscleral fixation of C-loop PCIOLs using a flapless one-knot suture technique,which were followed up for longer than 17mo.In this technique,the capsulorless IOL was suspended using a single suture for transscleral fixation of four feet.Then we compared its surgical outcomes and complications with the four-haptics PC-IOLs using the Student's t test and Chi-square test.RESULTS:Sixteen patients of 16 eyes with a mean age of 58.3±10.1y(42-76y)who received transscleral C-loop IOL implantation due to trauma,vitrectomy,or cataract surgery with inadequate capsule support showed improved visual acuity.The difference was not significant between two IOLs except the surgery time(P>0.05).The mean operation times of C-loop IOL surgery was 24.1±1.83min and 31.3±4.47min of the four-haptics PC-IOL method(P<0.0001).In the C-loop IOLs group,there was statistical difference between the preoperative and the postoperative UCVA(log MAR,1.20±0.50 vs 0.57±0.32,P=0.0003).There was no statistical difference between the preoperative and the postoperative BCVA(log MAR,0.66±0.46 vs 0.40±0.23,P=0.056).However,there was no statistically significant difference in postoperative UCVA and BCVA between the two IOLs(P>0.05).We did not detect any optic capture,IOL decentration or dislocation,suture exposed,or cystoid macular edema in patients underwent C-loop IOLs surgery.CONCLUSION:The novel flapless one-knot suture technique for transscleral fixation of C-loop IOL is a simple,reliable,and stable technique. 展开更多
关键词 C-loop intraocular lens implantation lens dislocation transscleral fixation four-haptics intraocular lens
下载PDF
Oxygen defect modulating the charge behavior in titanium dioxide for boosting photocatalytic nitrogen fixation performance
12
作者 Mengxia Ji Nianhua Liu +6 位作者 Kai Li Qing Xu Gaopeng Liu Bin Wang Jun Di Huaming Li Jiexiang Xia 《Materials Reports(Energy)》 EI 2023年第4期46-51,共6页
Extremely high-temperature and high-pressure requirement of Haber-Bosch process motivates the search for a sustainable ammonia synthesis approach under mild conditions.Photocatalytic technology is a potential solution... Extremely high-temperature and high-pressure requirement of Haber-Bosch process motivates the search for a sustainable ammonia synthesis approach under mild conditions.Photocatalytic technology is a potential solution to convert N2 to ammonia.However,the poor light absorption and low charge carrier separation efficiency in conventional semiconductors are bottlenecks for the application of this technology.Herein,a facile synthesis of anatase TiO_(2)nanosheets with an abundance of surface oxygen vacancies(TiO_(2)-OV)via the calcination treatment was reported.Photocatalytic experiments of the prepared anatase TiO_(2)samples showed that TiO_(2)-OV nanosheets exhibited remarkably increased ammonia yield for solar-driven N2 fixation in pure water,without adding any sacrificial agents.EPR,XPS,XRD,UV-Vis DRS,TEM,Raman,and PL techniques were employed to systematically explore the possible enhanced mechanism.Studies revealed that the introduced surface oxygen vacancies significantly extended the light absorption capability in the visible region,decreased the adsorption and activation barriers of inert N2,and improved the separation and transfer efficiency of the photogenerated electronhole pairs.Thus,a high rate of ammonia evolution in TiO_(2)-OV was realized.This work offers a promising and sustainable approach for the efficient artificial photosynthesis of ammonia. 展开更多
关键词 Titanium dioxide Oxygen vacancies Artificial photosynthesis Nitrogen fixation Charge separation
下载PDF
Comparative assessment of nitrogen fixation rate by ^(15)N_(2) tracer assays in the South China Sea
13
作者 Danyang Li Minfang Zheng +5 位作者 Yusheng Qiu Limin Lai Nengwang Chen Hongmei Jing Run Zhang Min Chen 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2023年第1期75-82,共8页
Nitrogen fixation is one of the most important sources of new nitrogen in the ocean and thus profoundly affects the nitrogen and carbon biogeochemical processes.The distribution,controlling factors,and flux of N2 fixa... Nitrogen fixation is one of the most important sources of new nitrogen in the ocean and thus profoundly affects the nitrogen and carbon biogeochemical processes.The distribution,controlling factors,and flux of N2 fixation in the global ocean remain uncertain,partly because of the lack of methodological uniformity.The^(15)N_(2)tracer assay(the original bubble method→the^(15)N_(2)-enriched seawater method→the modified bubble method)is the mainstream method for field measurements of N2 fixation rates(NFRs),among which the original bubble method is the most frequently used.However,accumulating evidence has suggested an underestimation of NFRs when using this method.To improve the availability of previous data,we compared NFRs measured by three^(15)N_(2)tracer assays in the South China Sea.Our results indicate that the relationship between NFRs measured by the original bubble method and the^(15)N_(2)-enriched seawater method varies obviously with area and season,which may be influenced by incubation time,diazotrophic composition,and environmental factors.In comparison,the relationship between NFRs measured by the original bubble method and the modified bubble method is more stable,indicating that the N2 fixation rates based on the original bubble methods may be underestimated by approximately 50%.Based on this result,we revised the flux of N2 fixation in the South China Sea to 40 mmol/(m2·a).Our results improve the availability and comparability of literature NFR data in the South China Sea.The comparison of the^(15)N_(2)tracer assay for NFRs measurements on a larger scale is urgently necessary over the global ocean for a more robust understanding of the role of N2 fixation in the marine nitrogen cycle. 展开更多
关键词 N2 fixation rate South China Sea ^(15)N_(2)tracer assay
下载PDF
Congenital stapes suprastructure fixation presenting with fluctuating auditory symptoms:A case report
14
作者 Sun Choi Seok Hyun Park +1 位作者 Ji Su Kim Jiwon Chang 《World Journal of Clinical Cases》 SCIE 2023年第1期249-254,共6页
BACKGROUND Stapes ankylosis is a rare cause of conductive hearing loss,and stapes suprastructure fixation is extremely rare with fewer than 30 reported cases.Patients usually visit the clinic with non-progressive cond... BACKGROUND Stapes ankylosis is a rare cause of conductive hearing loss,and stapes suprastructure fixation is extremely rare with fewer than 30 reported cases.Patients usually visit the clinic with non-progressive conductive hearing loss that typically began in the early years of life.CASE SUMMARY Herein,we report a case of a 37-year-old female with an isolated stapedial suprastructure fixation.The patient presented with unusual fluctuating auditory symptoms of tinnitus,ear fullness and mixed hearing loss.Pre-operative temporal bone computed tomography findings and operative findings revealed an isolated stapedial suprastructure fixation with monopod stapes caused by elongated pyramidal eminence.The hearing threshold recovered completely,and fluctuating auditory symptoms disappeared after the surgery.CONCLUSION This is the first report of stapedial suprastructure fixation with fluctuating auditory symptoms.Successful results are expected with surgical treatment. 展开更多
关键词 Isolated stapes ankylosis Stapes suprastructure fixation Elongated pyramidal eminence Stapes monopod Fluctuating auditory symptoms Exploratory tympanotomy Case report
下载PDF
Facile preparation of Ag_(2)S/KTa_(0.5)Nb_(0.5)O_(3) heterojunction for enhanced performance in catalytic nitrogen fixation via photocatalysis and piezo-photocatalysis
15
作者 Lu Chen Junfeng Wang +7 位作者 Xiaojing Li Jiayu Zhang Chunran Zhao Xin Hu Hongjun Lin Leihong Zhao Ying Wu Yiming He 《Green Energy & Environment》 SCIE EI CAS CSCD 2023年第6期1630-1643,共14页
In this work, a novel heterojunction composite Ag_(2)S/KTa_(x)Nb_(1-x)O_(3)was designed and synthesized through a combination of hydrothermal and precipitation procedures. The Ta/Nb ratio of the KTa_(x)Nb_(1-x)O_(3)an... In this work, a novel heterojunction composite Ag_(2)S/KTa_(x)Nb_(1-x)O_(3)was designed and synthesized through a combination of hydrothermal and precipitation procedures. The Ta/Nb ratio of the KTa_(x)Nb_(1-x)O_(3)and the Ag_(2)S content were optimized. The best 0.5% Ag_(2)S/KTa_(0.5)Nb_(0.5)O_(3)(KTN) sample presents an enhanced photocatalytic performance in ammonia synthesis than KTN and Ag_(2)S. Under simulated sunlight, the NH_(3)generation rate of 0.5% Ag_(2)S/KTN reaches 2.0 times that of pure KTN. Under visible light, the reaction rate ratio of the two catalysts is 6.0.XRD, XPS, and TEM analysis revealed that Ag2S was intimately decorated on the KTN nanocubes surface, which promoted the electron transfer between the two semiconductors. The band structure investigation indicated that the Ag_(2)S/KTN heterojunction established a type-Ⅱ band alignment with intimate contact, thus realizing the effective transfer and separation of photogenerated carriers. The change in charge separation was considered as the main reason for the enhanced photocatalytic performance. Interestingly, the Ag_(2)S/KTN composite exhibited higher NH3generation performance under the combined action of ultrasonic vibration and simulated sunlight. The enhanced piezo-photocatalytic performance can be ascribed that the piezoelectric effect of KTN improved the bulk separation of charge carriers in KTN. This study not only provides a potential catalyst for photocatalytic nitrogen fixation but also shows new ideas for the design of highly efficient catalysts via semiconductor modification and external field coupling. 展开更多
关键词 Photocatalytic nitrogen fixation Ag_(2)S/KTa_(0.5)Nb_(0.5)O_(3) Type-II heterojunction Piezo-photocatalysis Charge separation
下载PDF
Analysis of the Application of Windbreak and Sand Fixation Technology in Desert Roads
16
作者 Qianrong Yang 《Journal of World Architecture》 2023年第4期45-50,共6页
In order to solve the problems in the construction of desert roads and improve the quality of desert roads in China,this paper discusses the current windbreak and sand fixation technologies in desert areas in China,an... In order to solve the problems in the construction of desert roads and improve the quality of desert roads in China,this paper discusses the current windbreak and sand fixation technologies in desert areas in China,and puts forward relevant suggestions and corresponding solutions for each problem.This paper is written with hopes of contributing to the development of windbreak and sand fixation technologies in China as well as the development of the economy,society and environment in China's deserts. 展开更多
关键词 DESERT Windbreak and sand fixation Road construction
下载PDF
关于Rigid Internal Fixation一词译法和应用的说明
17
作者 顾晓明 《中国口腔颌面外科杂志》 CAS 2004年第1期21-21,共1页
关键词 igid INTERNAL fixation RIF 内固定 口腔颌面部 力学设计
下载PDF
One-stage Surgical Treatment for Thoracic and Lumbar Spinal Tuberculosis by Transpedicular Fixation, Debridement, and Combined Interbody and Posterior Fusion via a Posterior-only Approach 被引量:12
18
作者 冉兵 谢远龙 +1 位作者 严磊 蔡林 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2016年第4期541-547,共7页
This study examined the clinical outcomes of one-stage surgical treatment for patients with spinal tuberculosis via a posterior-only approach. Twenty-four patients with thoracic or lumbar spinal tuberculosis whose les... This study examined the clinical outcomes of one-stage surgical treatment for patients with spinal tuberculosis via a posterior-only approach. Twenty-four patients with thoracic or lumbar spinal tuberculosis whose lesions were confined to adjacent segments were admitted to our hospital and treated. The American Spinal Injury Association(ASIA) impairment scale was used to assess the neurological function. All patients were treated with one-stage surgical treatment via a posterior-only approach. The clinical efficacy was evaluated by the Japanese Orthopaedic Association(JOA) scores and oswestry disability index(ODI) of nerve function. Patients were evaluated preoperatively and postoperatively by measurement of spinal deformity using Cobb angle and radiological examination. All the patients were followed up for 13 to 27 months. They had significantly postoperative improvement in JOA score, ODI and ASIA classification scores. The kyphotic angles were significantly corrected and maintained at the final follow-up. Bone fusion was achieved within 4–12 months. It was concluded that one-stage surgical treatment via a posterior-only approach is effective and feasible for the treatment of spinal tuberculosis. 展开更多
关键词 spinal tuberculosis bone graft transpedicular fixation POSTERIOR KYPHOSIS
下载PDF
Application of internal fixation of steel-wire limited loop in early Achilles tendon rupture 被引量:10
19
作者 Zhe Chen Jia-Sen Wei +3 位作者 Zhao-Yang Hou Jiong Hu Yan-Guang Cao Qi-Xin Chen 《Asian Pacific Journal of Tropical Medicine》 SCIE CAS 2013年第11期902-907,共6页
Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of... Objective:To explore the clinical effect and safety of internal fixation of steel-wire limited loop in early Achilles tendon rupture.Methods:Seventy-six patients respectively with early transected and avulsed types of Achilles tendon rupture were selected and treated with internal fixation of steel-wire limited loop.The patients began to take exercise for their lower limbs through continous passive motion as early as possible after surgical repair,and the loops were removed after 3-5 months.Six months later,the condition of complications including Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis,cutaneous sensation in sural nerve dominance region,time back to preinjury work or learning as well as time to physical activities were observed.One year later,the therapeutic effect was evaluated,and the maximum circumferences of bilateral legs and raptured plane circumferences of Achilles tendon were measured.Results:The wound of all patients healed well,no complications like Achilles tendon re-rupture,wound fistula,wound infection and skin necrosis occured,and the cutaneous sensation in sural nerve dominance region was normal.The mean time back to preinjury work or learning as well as to pysical activities of all patients were respectively 10 and 22 weeks.Seventy out of 76 patients(92.1%) achieved an excellent effect,and 6(7.9%) good effect.The excellent and good rate came up to 100%.The maximum circumference in the affected leg decreased to 2 mm averagely compared with the offside,while the ruptured plane circumferences of Achilles tendon in the affected side increased to 2.2 mm compared with the offside.Conclusions:Kor early Achilles tendon rupture,internal fixation of steel-wire limited loop can recover the ankle function better,return to the preinjury state in the shortest lime,and has few complications. 展开更多
关键词 ACHILLES TENDON rupture Steel-wire LIMITED LOOP Internal fixation ANKLE function
下载PDF
Optimized nitrogen application methods to improve nitrogen use efficiency and nodule nitrogen fixation in a maize-soybean relay intercropping system 被引量:15
20
作者 YONG Tai-wen CHEN Ping +5 位作者 DONG Qian DU Qing YANG Feng WANG Xiao-chun LIU Wei-guo YANG Wen-yu 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2018年第3期664-676,共13页
In China, the abuse of chemical nitrogen (N) fertilizer results in decreasing N use efficiency (NUE), wasting resources and causing serious environmental problems. Cereal-legume intercropping is widely used to enh... In China, the abuse of chemical nitrogen (N) fertilizer results in decreasing N use efficiency (NUE), wasting resources and causing serious environmental problems. Cereal-legume intercropping is widely used to enhance crop yield and improve resource use efficiency, especially in Southwest China. To optimize N utilization and increase grain yield, we conducted a two-year field experiment with single-factor randomized block designs of a maize-soybean intercropping system (IMS). Three N rates, NN (no nitrogen application), LN (lower N application: 270 kg N ha-1), and CN (conventional N application: 330 kg N ha-1), and three topdressing distances of LN (LND), e.g., 15 cm (LND1), 30 cm (LND2) and 45 cm (LND3) from maize rows were evaluated. At the beginning seed stage (R5), the leghemoglobin content and nitrogenase activity of LND3 were 1.86 mg plant-1 and 0.14 mL h-1 plant-1, and those of LND1 and LND2 were increased by 31.4 and 24.5%, 6.4 and 32.9% compared with LND3, respectively. The ureide content and N accumulation of soybean organs in LND1 and LND2 were higher than those of LND3. The N uptake, NUE and N agronomy efficiency (NAE) of IMS under CN were 308.3 kg ha-1, 28.5%, and 5.7 kg grain kg-1 N, respectively; however, those of LN were significantly increased by 12.4, 72.5, and 51.6% compared with CN, respectively. The total yield in LND1 and LND2 was increased by 12.3 and 8.3% compared with CN, respectively. Those results suggested that LN with distances of 15-30 cm from the topdressing strip to the maize row was optimal in maize-soybean intercropping. Lower N input with an optimized fertilization location for IMS increased N fixation and N use efficiency without decreasing grain yield. 展开更多
关键词 relay intercropping lower nitrogen nitrogen use efficiency nitrogen fixation nitrogen uptake
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部