Background Sirolimus-eluting stents (SES) are reported to be associated with reduced late lumen loss (LLL), resulting in less frequent restenosis when compared to bare-metal stent. The current study aimed to asses...Background Sirolimus-eluting stents (SES) are reported to be associated with reduced late lumen loss (LLL), resulting in less frequent restenosis when compared to bare-metal stent. The current study aimed to assess the difference in LLL between SES with biodegradable and with permanent polymer. Methods From March 2010 to June 2011, 300 consecutive patients having only biodegradable polymers or permanent polymer SES for all diseased vessels were included. Serial quantitative coronary analysis was performed on both the "in-stent" and "segment" area, including the stented segment, as well as both five mm margins proximal and distal to the stent. The primary endpoint was the LLL defined as the minimal lumen diameter (MLD) post-stenting minus the MLD at nine-month after the indexed procedure. Results LLL was comparable between the two stents. Importantly, LLL for the distal segment (median 0.05 mm, interquartile 0 to 0.09 mm) was less severe compared with in-stent (median 0.13 mm, interquartile 0.08 to 0.18 mm) and proximal segment LLL (median 0.12 mm, interquartile 0.06 to 0.14 mm, all P 〈0.001 ). In general, the LLL was associated with the post-procedure MLD (b=0.28, P=0.002), hyperlipidemia (b=0.14, P=0.021), and calcified lesions (b=0.58, P=-0.001). The R2 and Radj of the multiple regression model were 0.651 and 0.625, respectively. Conclusions SES with either biodegradable or permanent polymer had lower value of LLL. The small amount of LLL at the distal segment possibly contributed to the less distal edge stenosis.展开更多
Background:Treatment of coronary bifurcation lesions remains challenging;a simple strategy has been preferred as of late,but the disadvantage is ostium stenosis or even occlusion of the side branch(SB).Only a few sing...Background:Treatment of coronary bifurcation lesions remains challenging;a simple strategy has been preferred as of late,but the disadvantage is ostium stenosis or even occlusion of the side branch(SB).Only a few single-center studies investigating the combination of a drug-eluting stent in the main branch followed by a drug-eluting balloon in the SB have been reported.This prospective,multicenter,randomized study aimed to investigate the safety and efficacy of a paclitaxel-eluting balloon(PEB)compared with regular balloon angioplasty(BA)in the treatment of non-left main coronary artery bifurcation lesions.Methods:Between December 2014 and November 2015,a total of 222 consecutive patients with bifurcation lesions were enrolled in this study at ten Chinese centers.Patients were randomly allocated at a 1:1 ratio to a PEB group(n=113)and a BA group(n=109).The primary efficacy endpoint was angiographic target lesion stenosis at 9 months.Secondary efficacy and safety endpoints included target lesion revascularization,target vessel revascularization,target lesion failure,major adverse cardiac and cerebral events(MACCEs),all-cause death,cardiac death,non-fatal myocardial infarction,and thrombosis in target lesions.The main analyses performed in this clinical trial included case shedding analysis,base-value equilibrium analysis,effectiveness analysis,and safety analysis.SAS version 9.4 was used for the statistical analyses.Results:At the 9-month angiographic follow-up,the difference in the primary efficacy endpoint of target lesion stenosis between the PEB(28.7%±18.7%)and BA groups(40.0%±19.0%)was-11.3%(95%confidence interval:-16.3%to-6.3%,Psuperiority<0.0001)in the intention-to-treat analysis,and similar results were recorded in the per-protocol analysis,demonstrating the superiority of PEB to BA.Late lumen loss was significantly lower in the PEB group than in the BA group(-0.06±0.32 vs.0.18±0.34 mm,P<0.0001).For intention-to-treat,there were no significant differences between PEB and BA in the 9-month percentages of MACCEs(0.9%vs.3.7%,P=0.16)or non-fatal myocardial infarctions(0 vs.0.9%,P=0.49).There were no clinical events of target lesion revascularization,target vessel revascularization,target lesion failure,all-cause death,cardiac death or target lesion thrombosis in either group.Conclusions:In de novo non-left main coronary artery bifurcations treated with provisional T stenting,SB dilation with the PEB group demonstrated better angiographic results than treatment with regular BA at the 9-month follow-up in terms of reduced target lesion stenosis.Trial registration:ClinicalTrials.gov,NCT02325817;https://clinicaltrials.gov.展开更多
Background First generation drug-eluting stents (DES) were associated with a high incidence of late stent thrombosis (ST),mainly due to delayed healing and re-endothelization by the durable polymer coating.This st...Background First generation drug-eluting stents (DES) were associated with a high incidence of late stent thrombosis (ST),mainly due to delayed healing and re-endothelization by the durable polymer coating.This study sought to assess the safety and efficacy of the Nano polymer-free sirolimus-eluting stent (SES) in the treatment of patients with de novo coronary artery lesions.Methods The Nano trial is the first randomized trial designed to compare the safety and efficacy of the Nano polymer-free SES and Partner durable-polymer SES (Lepu Medical Technology,Beijing,China) in the treatment of patients with de novo native coronary lesions.The primary endpoint was in-stent late lumen loss (LLL) at 9-month follow-up.The secondary endpoint was major adverse cardiac events (MACE),a composite of cardiac death,myocardial infarction or target lesion revascularization.Results A total of 291 patients (Nano group:n=143,Partner group:n=148) were enrolled in this trial from 19 Chinese centers.The Nano polymer-free SES was non-inferior to the Partner durable-polymer DES at the primary endpoint of 9 months (P 〈0.001).The 9-month in-segment LLL of the polymer-free Nano SES was comparable to the Partner SES (0.34±0.42) mm vs.(0.30±0.48) mm,P=0.21).The incidence of MACE in the Nano group were 7.6% compared to the Partner group of 5.9% (P=0.75) at 2 years follow-up.The frequency of cardiac death and stent thrombosis was low for both Nano and Partner SES (0.8% vs.0.7%,0.8% vs.1.5%,both P=1.00).Conclusions In this multicenter randomized Nano trial,the Nano polymer-free SES showed similar safety and efficacy compared with the Partner SES in the treatment of patients with de novo coronary artery lesions.Trials in patients with complex lesions and longer term follow-up are necessary to confirm the clinical performance of this novel Nano polymer-free SES.展开更多
Background The zotarolimus-eluting stent has shown larger in-stent late lumen loss compared to sirolimus-eluting stents in previous studies. However, this has not been thoroughly evaluated in ST elevation myocardial i...Background The zotarolimus-eluting stent has shown larger in-stent late lumen loss compared to sirolimus-eluting stents in previous studies. However, this has not been thoroughly evaluated in ST elevation myocardial infarction. Methods This was a prospective, randomized, controlled trial evaluating angiographic outcomes in patients presenting with ST elevation myocardial infarction, treated with zotarolimus-eluting stents or sirolimus-eluting stents. From March 2007 to February 2009, 122 patients were randomized to zotarolimus-eluting stents or sirolimus-eluting stents in a 1:1 fashion. The primary endpoint was 9-month in-stent late lumen loss confirmed by coronary angiography, and secondary endpoints were percent diameter stenosis, binary restenosis rate, major adverse cardiac events (a composite of cardiac death, non-fatal myocardial infarction, and target vessel revascularization), and late-acquired incomplete stent apposition. Results Angiographic in-stent late lumen loss was significantly higher in the zotarolimus-eluting stent group compared to the sirolimus-eluting stent group ((0.49±0.65) mm vs. (0.10±0.46) mm, P=0.001). Percent diameter stenosis at 9-month follow-up was also larger in the zotarolimus-eluting stent group ((30.0±17.9)% vs. (17.6±14.0)%, P 〈0.001). In-segment analysis showed similar findings. There were no significant differences in binary restenosis rate, major adverse cardiac events, and late-acquired incomplete stent apposition. Conclusions Compared to sirolimus-eluting stents, the zotarolimus-eluting stent is associated with significantly higher in-stent late lumen loss at 9-month angiographic follow-up in the treatment of ST elevation myocardial infarction. Although there was no significant difference in 1-year clinical outcomes, the clinical implication of increased late lumen loss should be further studied.展开更多
文摘Background Sirolimus-eluting stents (SES) are reported to be associated with reduced late lumen loss (LLL), resulting in less frequent restenosis when compared to bare-metal stent. The current study aimed to assess the difference in LLL between SES with biodegradable and with permanent polymer. Methods From March 2010 to June 2011, 300 consecutive patients having only biodegradable polymers or permanent polymer SES for all diseased vessels were included. Serial quantitative coronary analysis was performed on both the "in-stent" and "segment" area, including the stented segment, as well as both five mm margins proximal and distal to the stent. The primary endpoint was the LLL defined as the minimal lumen diameter (MLD) post-stenting minus the MLD at nine-month after the indexed procedure. Results LLL was comparable between the two stents. Importantly, LLL for the distal segment (median 0.05 mm, interquartile 0 to 0.09 mm) was less severe compared with in-stent (median 0.13 mm, interquartile 0.08 to 0.18 mm) and proximal segment LLL (median 0.12 mm, interquartile 0.06 to 0.14 mm, all P 〈0.001 ). In general, the LLL was associated with the post-procedure MLD (b=0.28, P=0.002), hyperlipidemia (b=0.14, P=0.021), and calcified lesions (b=0.58, P=-0.001). The R2 and Radj of the multiple regression model were 0.651 and 0.625, respectively. Conclusions SES with either biodegradable or permanent polymer had lower value of LLL. The small amount of LLL at the distal segment possibly contributed to the less distal edge stenosis.
文摘Background:Treatment of coronary bifurcation lesions remains challenging;a simple strategy has been preferred as of late,but the disadvantage is ostium stenosis or even occlusion of the side branch(SB).Only a few single-center studies investigating the combination of a drug-eluting stent in the main branch followed by a drug-eluting balloon in the SB have been reported.This prospective,multicenter,randomized study aimed to investigate the safety and efficacy of a paclitaxel-eluting balloon(PEB)compared with regular balloon angioplasty(BA)in the treatment of non-left main coronary artery bifurcation lesions.Methods:Between December 2014 and November 2015,a total of 222 consecutive patients with bifurcation lesions were enrolled in this study at ten Chinese centers.Patients were randomly allocated at a 1:1 ratio to a PEB group(n=113)and a BA group(n=109).The primary efficacy endpoint was angiographic target lesion stenosis at 9 months.Secondary efficacy and safety endpoints included target lesion revascularization,target vessel revascularization,target lesion failure,major adverse cardiac and cerebral events(MACCEs),all-cause death,cardiac death,non-fatal myocardial infarction,and thrombosis in target lesions.The main analyses performed in this clinical trial included case shedding analysis,base-value equilibrium analysis,effectiveness analysis,and safety analysis.SAS version 9.4 was used for the statistical analyses.Results:At the 9-month angiographic follow-up,the difference in the primary efficacy endpoint of target lesion stenosis between the PEB(28.7%±18.7%)and BA groups(40.0%±19.0%)was-11.3%(95%confidence interval:-16.3%to-6.3%,Psuperiority<0.0001)in the intention-to-treat analysis,and similar results were recorded in the per-protocol analysis,demonstrating the superiority of PEB to BA.Late lumen loss was significantly lower in the PEB group than in the BA group(-0.06±0.32 vs.0.18±0.34 mm,P<0.0001).For intention-to-treat,there were no significant differences between PEB and BA in the 9-month percentages of MACCEs(0.9%vs.3.7%,P=0.16)or non-fatal myocardial infarctions(0 vs.0.9%,P=0.49).There were no clinical events of target lesion revascularization,target vessel revascularization,target lesion failure,all-cause death,cardiac death or target lesion thrombosis in either group.Conclusions:In de novo non-left main coronary artery bifurcations treated with provisional T stenting,SB dilation with the PEB group demonstrated better angiographic results than treatment with regular BA at the 9-month follow-up in terms of reduced target lesion stenosis.Trial registration:ClinicalTrials.gov,NCT02325817;https://clinicaltrials.gov.
文摘Background First generation drug-eluting stents (DES) were associated with a high incidence of late stent thrombosis (ST),mainly due to delayed healing and re-endothelization by the durable polymer coating.This study sought to assess the safety and efficacy of the Nano polymer-free sirolimus-eluting stent (SES) in the treatment of patients with de novo coronary artery lesions.Methods The Nano trial is the first randomized trial designed to compare the safety and efficacy of the Nano polymer-free SES and Partner durable-polymer SES (Lepu Medical Technology,Beijing,China) in the treatment of patients with de novo native coronary lesions.The primary endpoint was in-stent late lumen loss (LLL) at 9-month follow-up.The secondary endpoint was major adverse cardiac events (MACE),a composite of cardiac death,myocardial infarction or target lesion revascularization.Results A total of 291 patients (Nano group:n=143,Partner group:n=148) were enrolled in this trial from 19 Chinese centers.The Nano polymer-free SES was non-inferior to the Partner durable-polymer DES at the primary endpoint of 9 months (P 〈0.001).The 9-month in-segment LLL of the polymer-free Nano SES was comparable to the Partner SES (0.34±0.42) mm vs.(0.30±0.48) mm,P=0.21).The incidence of MACE in the Nano group were 7.6% compared to the Partner group of 5.9% (P=0.75) at 2 years follow-up.The frequency of cardiac death and stent thrombosis was low for both Nano and Partner SES (0.8% vs.0.7%,0.8% vs.1.5%,both P=1.00).Conclusions In this multicenter randomized Nano trial,the Nano polymer-free SES showed similar safety and efficacy compared with the Partner SES in the treatment of patients with de novo coronary artery lesions.Trials in patients with complex lesions and longer term follow-up are necessary to confirm the clinical performance of this novel Nano polymer-free SES.
文摘Background The zotarolimus-eluting stent has shown larger in-stent late lumen loss compared to sirolimus-eluting stents in previous studies. However, this has not been thoroughly evaluated in ST elevation myocardial infarction. Methods This was a prospective, randomized, controlled trial evaluating angiographic outcomes in patients presenting with ST elevation myocardial infarction, treated with zotarolimus-eluting stents or sirolimus-eluting stents. From March 2007 to February 2009, 122 patients were randomized to zotarolimus-eluting stents or sirolimus-eluting stents in a 1:1 fashion. The primary endpoint was 9-month in-stent late lumen loss confirmed by coronary angiography, and secondary endpoints were percent diameter stenosis, binary restenosis rate, major adverse cardiac events (a composite of cardiac death, non-fatal myocardial infarction, and target vessel revascularization), and late-acquired incomplete stent apposition. Results Angiographic in-stent late lumen loss was significantly higher in the zotarolimus-eluting stent group compared to the sirolimus-eluting stent group ((0.49±0.65) mm vs. (0.10±0.46) mm, P=0.001). Percent diameter stenosis at 9-month follow-up was also larger in the zotarolimus-eluting stent group ((30.0±17.9)% vs. (17.6±14.0)%, P 〈0.001). In-segment analysis showed similar findings. There were no significant differences in binary restenosis rate, major adverse cardiac events, and late-acquired incomplete stent apposition. Conclusions Compared to sirolimus-eluting stents, the zotarolimus-eluting stent is associated with significantly higher in-stent late lumen loss at 9-month angiographic follow-up in the treatment of ST elevation myocardial infarction. Although there was no significant difference in 1-year clinical outcomes, the clinical implication of increased late lumen loss should be further studied.