The scale factor accuracy of superconducting gravimeters (SG) can be largely improved by a high repetition rate of calibration experiments. At stations where the availability of absolute gravimeters is limited, care...The scale factor accuracy of superconducting gravimeters (SG) can be largely improved by a high repetition rate of calibration experiments. At stations where the availability of absolute gravimeters is limited, carefully calibrated spring gravimeters can be used for providing the reference signal assuming the irregular drift is properly adjusted. The temporal stability of the SG scale factor is assessable by comparing the temporal variations of M2 tidal parameters observed at neighboring SG sites or from synthetic tide models. Combining these methods reduces the SG scale factor error to a few 0.1%0. The paper addresses the particular procedure required for evaluating the calibration experiments based on spring gravimeters and presents results obtained at Conrad observatory (Austria). Comparing the M2 amplitude factor modulation helped to reveal a SG scale factor offset of about 0.2%0 due to re-installation.展开更多
This work analyzes the quality of crustal tilt and strain observations during 2014, which were acquired from 269 sets of ground tiltmeters and 212 sets of strainmeters. In terms of data quality, the water tube tiltmet...This work analyzes the quality of crustal tilt and strain observations during 2014, which were acquired from 269 sets of ground tiltmeters and 212 sets of strainmeters. In terms of data quality, the water tube tiltmeters presented the highest rate of excellent quality,approximately 91%, and the pendulum tiltmeters and ground strainmeters yielded rates of81% and 78%, respectively. This means that a total of 380 sets of instruments produced high-quality observational data suitable for scientific investigations and analyses.展开更多
文摘The scale factor accuracy of superconducting gravimeters (SG) can be largely improved by a high repetition rate of calibration experiments. At stations where the availability of absolute gravimeters is limited, carefully calibrated spring gravimeters can be used for providing the reference signal assuming the irregular drift is properly adjusted. The temporal stability of the SG scale factor is assessable by comparing the temporal variations of M2 tidal parameters observed at neighboring SG sites or from synthetic tide models. Combining these methods reduces the SG scale factor error to a few 0.1%0. The paper addresses the particular procedure required for evaluating the calibration experiments based on spring gravimeters and presents results obtained at Conrad observatory (Austria). Comparing the M2 amplitude factor modulation helped to reveal a SG scale factor offset of about 0.2%0 due to re-installation.
基金supported by Special Foundation of Earthquake Science(201408006)Director Foundation of Institute of Seismology,China Earthquake Administration(201516214)
文摘This work analyzes the quality of crustal tilt and strain observations during 2014, which were acquired from 269 sets of ground tiltmeters and 212 sets of strainmeters. In terms of data quality, the water tube tiltmeters presented the highest rate of excellent quality,approximately 91%, and the pendulum tiltmeters and ground strainmeters yielded rates of81% and 78%, respectively. This means that a total of 380 sets of instruments produced high-quality observational data suitable for scientific investigations and analyses.