Natural radioactivity radionuclides in building materials, such as^(226)Ra,^(232)Th and^(40)K, cause indoor exposure due to their gamma-rays. In this research, in a standard dwelling room(5.0 m 9 4.0 m 9 2.8 m), with ...Natural radioactivity radionuclides in building materials, such as^(226)Ra,^(232)Th and^(40)K, cause indoor exposure due to their gamma-rays. In this research, in a standard dwelling room(5.0 m 9 4.0 m 9 2.8 m), with the floor covered by various granite stones, was set up to simulate the dose rates from the radionuclides using MCNP4 C code. Using samples of granite building products in Iran, activities of the^(226)Ra,^(232)Th and^(40)K were measured at 3.8–94.2, 6.5–172.2 and 556.9–1529.2 Bq kg^(-1),respectively. The simulated dose rates were26.31–184.36 n Gy h^(-1), while the measured dose rates were 27.70–204.17 n Gy h^(-1). With the results in good agreement, the simulation is suitable for any kind of dwelling places.展开更多
核电站中乏燃料储存格架用到的中子吸收材料需要兼具结构和功能一体化的要求,本文提出用碳纤维Cf增强B4C/Al中子吸收复合材料。利用Monte Carlo方法对碳纤维增强铝基碳化硼中子吸收材料(Cf/B4C/Al)的中子透射率进行模拟计算,研究B4C含量...核电站中乏燃料储存格架用到的中子吸收材料需要兼具结构和功能一体化的要求,本文提出用碳纤维Cf增强B4C/Al中子吸收复合材料。利用Monte Carlo方法对碳纤维增强铝基碳化硼中子吸收材料(Cf/B4C/Al)的中子透射率进行模拟计算,研究B4C含量、Cf含量、不同能量中子入射以及材料厚度变化时对中子透射率的影响,并与B4C/Al材料进行比较。结果表明,在1 e V-0.1 Me V能量范围的中子入射下,当B4C含量小于35%时,加入碳纤维能明显改善B4C/Al材料的中子屏蔽性能;在100 e V中子入射下,材料的中子透射率随B4C含量增加呈现指数下降;且Cf/B4C/Al材料的中子透射率随碳纤维含量增加持续降低;当Cf含量达到10%时,材料中子透射率降至最低,之后趋于平稳。通过模拟计算,得到Cf/B4C/Al材料的各组分的最优配比为35 vol.%B4C和10 vol.%Cf。展开更多
本文主要是对植入科学公司生产的模型3500碘-125植入治疗粒子源的一系列剂量学特征的研究。粒子源的各个剂量学参量通过使用蒙特卡罗方法计算得到。计算模型材料采用了两种等效水:固体水和液态水。粒子源的剂量学参量如剂量率常数、径...本文主要是对植入科学公司生产的模型3500碘-125植入治疗粒子源的一系列剂量学特征的研究。粒子源的各个剂量学参量通过使用蒙特卡罗方法计算得到。计算模型材料采用了两种等效水:固体水和液态水。粒子源的剂量学参量如剂量率常数、径向剂量函数和各项异性函数等的确定依照美国医学物理学家协会(American Association of Physicists in Medicine AAPM)第43次工作报告。蒙特卡罗模拟得到液态水的剂量率为0.997 cGyh-1U-1,固态水的为1.027 cGyh-1U-1。与前同类研究比较,本次研究的剂量率常数与同类研究所报道的数据较为一致。展开更多
使用MCNP5程序模拟了能量为14.88 Me V的快中子在(W+B_4C)/Al和W/Al复合材料中的输运过程,并与铅硼聚乙烯、聚乙烯以及钨进行对比。计算了各屏蔽材料的中子衰减性能、中子透射能谱以及中子俘获过程中释放γ射线的透射能谱,为中子屏蔽材...使用MCNP5程序模拟了能量为14.88 Me V的快中子在(W+B_4C)/Al和W/Al复合材料中的输运过程,并与铅硼聚乙烯、聚乙烯以及钨进行对比。计算了各屏蔽材料的中子衰减性能、中子透射能谱以及中子俘获过程中释放γ射线的透射能谱,为中子屏蔽材料的选择提供了理论依据。模拟结果和实际结果吻合,证实了蒙特卡罗方法的可靠性。模拟结果也可以得出,对于快中子,高原子序数材料的屏蔽效果要好于低原子序数材料,含钨45%的复合材料的屏蔽性能与商用铅硼聚乙烯的屏蔽效能相近,但是激发γ射线能量低于铅硼聚乙烯,考虑到成分可调控性、使用温度以及力学性能等因素,(W+B_4C)/Al复合材料是一种极具应用潜力的新型中子屏蔽材料。展开更多
文摘Natural radioactivity radionuclides in building materials, such as^(226)Ra,^(232)Th and^(40)K, cause indoor exposure due to their gamma-rays. In this research, in a standard dwelling room(5.0 m 9 4.0 m 9 2.8 m), with the floor covered by various granite stones, was set up to simulate the dose rates from the radionuclides using MCNP4 C code. Using samples of granite building products in Iran, activities of the^(226)Ra,^(232)Th and^(40)K were measured at 3.8–94.2, 6.5–172.2 and 556.9–1529.2 Bq kg^(-1),respectively. The simulated dose rates were26.31–184.36 n Gy h^(-1), while the measured dose rates were 27.70–204.17 n Gy h^(-1). With the results in good agreement, the simulation is suitable for any kind of dwelling places.
文摘核电站中乏燃料储存格架用到的中子吸收材料需要兼具结构和功能一体化的要求,本文提出用碳纤维Cf增强B4C/Al中子吸收复合材料。利用Monte Carlo方法对碳纤维增强铝基碳化硼中子吸收材料(Cf/B4C/Al)的中子透射率进行模拟计算,研究B4C含量、Cf含量、不同能量中子入射以及材料厚度变化时对中子透射率的影响,并与B4C/Al材料进行比较。结果表明,在1 e V-0.1 Me V能量范围的中子入射下,当B4C含量小于35%时,加入碳纤维能明显改善B4C/Al材料的中子屏蔽性能;在100 e V中子入射下,材料的中子透射率随B4C含量增加呈现指数下降;且Cf/B4C/Al材料的中子透射率随碳纤维含量增加持续降低;当Cf含量达到10%时,材料中子透射率降至最低,之后趋于平稳。通过模拟计算,得到Cf/B4C/Al材料的各组分的最优配比为35 vol.%B4C和10 vol.%Cf。
文摘本文主要是对植入科学公司生产的模型3500碘-125植入治疗粒子源的一系列剂量学特征的研究。粒子源的各个剂量学参量通过使用蒙特卡罗方法计算得到。计算模型材料采用了两种等效水:固体水和液态水。粒子源的剂量学参量如剂量率常数、径向剂量函数和各项异性函数等的确定依照美国医学物理学家协会(American Association of Physicists in Medicine AAPM)第43次工作报告。蒙特卡罗模拟得到液态水的剂量率为0.997 cGyh-1U-1,固态水的为1.027 cGyh-1U-1。与前同类研究比较,本次研究的剂量率常数与同类研究所报道的数据较为一致。
文摘使用MCNP5程序模拟了能量为14.88 Me V的快中子在(W+B_4C)/Al和W/Al复合材料中的输运过程,并与铅硼聚乙烯、聚乙烯以及钨进行对比。计算了各屏蔽材料的中子衰减性能、中子透射能谱以及中子俘获过程中释放γ射线的透射能谱,为中子屏蔽材料的选择提供了理论依据。模拟结果和实际结果吻合,证实了蒙特卡罗方法的可靠性。模拟结果也可以得出,对于快中子,高原子序数材料的屏蔽效果要好于低原子序数材料,含钨45%的复合材料的屏蔽性能与商用铅硼聚乙烯的屏蔽效能相近,但是激发γ射线能量低于铅硼聚乙烯,考虑到成分可调控性、使用温度以及力学性能等因素,(W+B_4C)/Al复合材料是一种极具应用潜力的新型中子屏蔽材料。