We study the feasibility of endoscopic optical Doppler tomography with a micro-electro-mechanical system(MEMS) mirror based probe. The additional phase shifts introduced by the probe are tracked and formulated.The sup...We study the feasibility of endoscopic optical Doppler tomography with a micro-electro-mechanical system(MEMS) mirror based probe. The additional phase shifts introduced by the probe are tracked and formulated.The suppression method of the probe phase shifts is proposed and validated by fluid flow detection experiments.In vivo blood flow detection is also implemented on a hairless mouse. The velocities of the blood flow in two directions are obtained to be-8.1 mm/s and 6.6 mm/s, respectively.展开更多
<div style="text-align:justify;"> In this work, a design of a compact optical MEMS-based lidar scanning system with a large field of view (FOV) and small distortion is presented. The scanning system ap...<div style="text-align:justify;"> In this work, a design of a compact optical MEMS-based lidar scanning system with a large field of view (FOV) and small distortion is presented. The scanning system applies an off-axis structure and the length of the system can be reduced to about 10 cm in an optimized way. Simulation results show that a large FOV is achieved under a uniform scanning scheme. In addition, the spot size less than 20 cm at distance of 100 m is also realized. The optical scanning system can be used for the vehicle-mounted Lidar. </div>展开更多
Three-dimensional(3D)lidar has been widely used in various fields.The MEMS scanning system is one of its most important components,while the limitation of scanning angle is the main obstacle to improve the demerit for...Three-dimensional(3D)lidar has been widely used in various fields.The MEMS scanning system is one of its most important components,while the limitation of scanning angle is the main obstacle to improve the demerit for its application in various fields.In this paper,a folded large field of view scanning optical system is proposed.The structure and parameters of the system are determined by theoretical derivation of ray tracing.The optical design software Zemax is used to design the system.After optimization,the final structure performs well in collimation and beam expansion.The results show that the scan angle can be expanded from±5°to±26.5°,and finally the parallel light scanning is realized.The spot diagram at a distance of 100 mm from the exit surface shows that the maximum radius of the spot is 0.506 mm with a uniformly distributed spot.The maximum radius of the spot at 100 m is 19 cm,and the diffusion angle is less than 2 mrad.The energy concentration in the spot range is greater than 90%with a high system energy concentration,and the parallelism is good.This design overcomes the shortcoming of the small mechanical scanning angle of the MEMS lidar,and has good performance in collimation and beam expansion.It provides a design method for large-scale application of MEMS lidar.展开更多
基金Supported by the National Natural Science Foundation of China under Grant No 61705199the Natural Science Foundation of Henan Province under Grant No 162300410317+2 种基金the Henan Science and Technology Project under Grant Nos 162102310576and 172102210542the Zhengzhou Science and Technology Project under Grant No 153PKJGG125the US National Science Foundation under Grant No 1002209
文摘We study the feasibility of endoscopic optical Doppler tomography with a micro-electro-mechanical system(MEMS) mirror based probe. The additional phase shifts introduced by the probe are tracked and formulated.The suppression method of the probe phase shifts is proposed and validated by fluid flow detection experiments.In vivo blood flow detection is also implemented on a hairless mouse. The velocities of the blood flow in two directions are obtained to be-8.1 mm/s and 6.6 mm/s, respectively.
文摘<div style="text-align:justify;"> In this work, a design of a compact optical MEMS-based lidar scanning system with a large field of view (FOV) and small distortion is presented. The scanning system applies an off-axis structure and the length of the system can be reduced to about 10 cm in an optimized way. Simulation results show that a large FOV is achieved under a uniform scanning scheme. In addition, the spot size less than 20 cm at distance of 100 m is also realized. The optical scanning system can be used for the vehicle-mounted Lidar. </div>
基金the Shenzhen Fundamental Research Program(Grant No.JCYJ2020109150808037)the National Key Scientific Instrument and Equipment Development Projects of China(Grant No.62027823)the National Natural Science Foundation of China(Grant No.61775048)。
文摘Three-dimensional(3D)lidar has been widely used in various fields.The MEMS scanning system is one of its most important components,while the limitation of scanning angle is the main obstacle to improve the demerit for its application in various fields.In this paper,a folded large field of view scanning optical system is proposed.The structure and parameters of the system are determined by theoretical derivation of ray tracing.The optical design software Zemax is used to design the system.After optimization,the final structure performs well in collimation and beam expansion.The results show that the scan angle can be expanded from±5°to±26.5°,and finally the parallel light scanning is realized.The spot diagram at a distance of 100 mm from the exit surface shows that the maximum radius of the spot is 0.506 mm with a uniformly distributed spot.The maximum radius of the spot at 100 m is 19 cm,and the diffusion angle is less than 2 mrad.The energy concentration in the spot range is greater than 90%with a high system energy concentration,and the parallelism is good.This design overcomes the shortcoming of the small mechanical scanning angle of the MEMS lidar,and has good performance in collimation and beam expansion.It provides a design method for large-scale application of MEMS lidar.