Calculation of the Standard Model Parameters and Particles Based on a SU(4) Preon Model
1
作者 Jan Helm 《Journal of Modern Physics》 2024年第1期64-124,共61页
This paper describes an extension and a new foundation of the Standard Model of particle physics based on a SU(4)-force called hyper-color, and on preon subparticles. The hyper-color force is a generalization of the S... This paper describes an extension and a new foundation of the Standard Model of particle physics based on a SU(4)-force called hyper-color, and on preon subparticles. The hyper-color force is a generalization of the SU(2)-based weak interaction and the SU(1)-based right-chiral self-interaction, in which the W-and the Z-bosons are Yukawa residual-field-carriers of the hyper-color force, in the same sense as the pions are the residual-field-carriers of the color SU(3) interaction. Using the method of numerical minimization of the SU(4)-action based on this model, the masses and the inner structure of leptons, quarks and weak bosons are calculated: the mass results are very close to the experimental values. We calculate also precisely the value of the Cabibbo angle, so the mixing matrices of the Standard model, CKM matrix for quarks and PMNS matrix for neutrinos can also be calculated. In total, we reduce the 29 parameters of the Standard Model to a total of 7 parameters. 展开更多
关键词 SU(4) Generalization of Weak Interaction Extension of standard Model Numerical Minimization of Action Hyper-Color Preon
下载PDF
新标09CrCuSb耐酸钢的耐50%H_(2)SO_(4)腐蚀性能
2
作者 郑健 张佳伟 +3 位作者 袁渊 张成元 黄峰 刘静 《腐蚀与防护》 CAS CSCD 北大核心 2024年第4期8-13,共6页
通过电化学测试和全浸腐蚀试验,研究了不同温度(25,50,60,70℃)条件下新标09CrCuSb耐酸钢在50%H_(2)SO_(4)溶液中的腐蚀行为。结果表明:随着温度从25℃升至70℃,新标09CrCuSb钢的腐蚀速率整体呈现增大趋势,在70℃时,腐蚀速率达到最高,为... 通过电化学测试和全浸腐蚀试验,研究了不同温度(25,50,60,70℃)条件下新标09CrCuSb耐酸钢在50%H_(2)SO_(4)溶液中的腐蚀行为。结果表明:随着温度从25℃升至70℃,新标09CrCuSb钢的腐蚀速率整体呈现增大趋势,在70℃时,腐蚀速率达到最高,为2.70 g/(m^(2)·h),这与随温度升高,腐蚀产物中具有保护性作用的Fe_(3)O_(4)含量减少,无保护作用的FeSO_(4)·H_(2)O含量增加以及锈层中微孔变化有关。另外,由于新标调整了09CrCuSb钢中Cu、Mo、Sn、Sb、W等元素的含量,与旧标09CrCuSb钢相比,阳极维钝电流密度J维钝降低,同等温度条件下,新标09CrCuSb钢的耐蚀性得到较大改善。 展开更多
关键词 新标09CrCuSb耐酸钢 50%H_(2)SO_(4)溶液 腐蚀 温度影响
下载PDF
基于4C培训法的医患沟通技能课程设计与实施
3
作者 王辰 李颖 +1 位作者 丛鲁红 朱宇清 《中国毕业后医学教育》 2024年第4期291-295,共5页
目的探讨4 C培训法在医患沟通技能培训方面对提高住院医师沟通技能的效果。方法选取2021年10月—2023年6月年中日友好医院住院医师67名,按照4 C培训法实施医患沟通技能培训,培训前后使用SEGUE量表评估沟通技能变化情况,并完成课程满意... 目的探讨4 C培训法在医患沟通技能培训方面对提高住院医师沟通技能的效果。方法选取2021年10月—2023年6月年中日友好医院住院医师67名,按照4 C培训法实施医患沟通技能培训,培训前后使用SEGUE量表评估沟通技能变化情况,并完成课程满意度调查,培训后鼓励上报临床工作中沟通技能应用感受。结果住院医师沟通培训后在沟通开始、信息采集、信息提供、情感沟通及结束谈话等沟通模块均较培训前明显进步,差异有统计学意义(P<0.01)。中医医患沟通技巧及特殊人群沟通模块满意度稍低,其余模块满意度均较高。培训后26名住院医师汇报了沟通技巧在临床实践中应用情况。结论采用4 C培训法的医患沟通技能培训可以在较短时间内提升住院医师的医患沟通能力,但需要加强信息采集和情感沟通方面的培训。 展开更多
关键词 医患沟通 4 C培训法 住院医师规范化培训
下载PDF
三维有限元方法分析“All-on-4”技术的生物力学特征
4
作者 陆婧 李英 +5 位作者 孟茂花 王欢 舒佳玉 李文杰 罗云彩 董强 《中国组织工程研究》 CAS 北大核心 2024年第22期3591-3596,共6页
背景:随着无牙颌修复需求增加,“All-on-4”技术被广泛应用。种植体与天然牙的载荷传递方式不同,三维有限元分析可研究功能载荷作用下种植体及周围骨组织的应力分布,并在此基础上为寻找适合的种植体材料、优化种植体的几何结构、设计临... 背景:随着无牙颌修复需求增加,“All-on-4”技术被广泛应用。种植体与天然牙的载荷传递方式不同,三维有限元分析可研究功能载荷作用下种植体及周围骨组织的应力分布,并在此基础上为寻找适合的种植体材料、优化种植体的几何结构、设计临床手术方案提供了研究方法。目的:对三维有限元分析法在“All-on-4”技术方面的相关研究作一综述。方法:检索中国知网和PubMed数据库2003-2023年相关文献,英文检索词为“Finite Element Method,All-on-4,edentulous,Biomechanics”,中文检索词为“有限元,All-on-4,无牙颌,生物力学”,根据纳入排除标准筛选符合标准的文献,最终纳入65篇文献进行综述。结果与结论:①对水平骨量不足的情况,研究者们可以选择应用窄直径种植体,但需要注意悬臂的存在对应力分布的影响,降低失败的风险。②“All-on-4”概念通过倾斜远中种植体的方法,减少骨的应力分布,但在不同的颌骨类型中,远中种植体倾斜的理想角度还需要进一步的研究。③悬臂的存在会增加种植失败的风险,将悬臂长度/AP距(CL/AP)的比值控制在0.9时,有助于减少机械并发症的发生。④用弹性模量较低的材料制作支架时,支架自身的应力较小,但会增加种植体、中央螺丝、基台及种植体周围骨组织的应力,相反使用弹性模量较大的材料,会降低修复体组件和种植体周围骨组织的应力,但支架本身的应力较高。⑤“All-on-4”概念可以实现较好的力学平衡,但需结合患者自身的具体情况制定一个长期有效的治疗方案。⑥合理的咬合设计是影响种植治疗成功的关键,尖牙引导牙合和组牙功能牙合在修复体的寿命方面无差异。然而,影响咬合设计的原因有很多,未来还需要进一步的体外实验以及大量临床研究来探索“All-on-4”理想的咬合设计。 展开更多
关键词 有限元 All-on-4 无牙颌 窄种植体 标准种植体 倾斜种植体 悬臂梁 短种植体 支架材料 咬合设计 生物力学
下载PDF
药物中间体5-(4-溴苯基)-4,6-二氯嘧啶有关物质和含量分析方法
5
作者 柳毅 张卫 +1 位作者 王文标 高军龙 《广州化工》 CAS 2024年第2期184-186,共3页
建立了5-(4-溴苯基)-4,6-二氯嘧啶高效液相色谱法测定有关物质和含量的分析方法。以自身对照法计算未知杂质含量,按外标法计算已知杂质和主成分含量。使用Waters XBridge■-C_(18)色谱柱,流动相为0.1%磷酸和乙腈,梯度洗脱;检测波长210 n... 建立了5-(4-溴苯基)-4,6-二氯嘧啶高效液相色谱法测定有关物质和含量的分析方法。以自身对照法计算未知杂质含量,按外标法计算已知杂质和主成分含量。使用Waters XBridge■-C_(18)色谱柱,流动相为0.1%磷酸和乙腈,梯度洗脱;检测波长210 nm。已知杂质在0.1~2.0μg·mL^(-1)浓度范围内线性关系良好,平均加样回收率在90%~110%,其RSD小于5%。该方法快速、准确,适用于5-(4-溴苯基)-4,6-二氯嘧啶有关物质和含量分析方法的检测。 展开更多
关键词 5-(4-溴苯基)-4 6-二氯嘧啶 高效液相色谱 自身对照 外标法
下载PDF
MEPG-4中的二进制格式场景描述 被引量:1
6
作者 周俊茂 宋建新 《电视技术》 北大核心 2002年第12期47-49,共3页
描述了MPEG-4中二进制格式场景描述的特征,并对其流化多媒体、实现高压缩性、实现用户交互性等一组功能进行了介绍。
关键词 mepg-4 二进制格式场景 视听对象 多媒体 交互性
下载PDF
Low-temperature heat capacities and standard molar enthalpy of formation of 4-(2-aminoethyl)-phenol (C_8H_(11)NO)
7
作者 邸友莹 孔玉霞 +1 位作者 杨伟伟 谭志诚 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第9期3276-3283,共8页
This paper reports that low-temperature heat capacities of 4-(2-aminoethyl)-phenol (C8H11NO) are measured by a precision automated adiabatic calorimeter over the temperature range from 78 to 400 K. A polynomial eq... This paper reports that low-temperature heat capacities of 4-(2-aminoethyl)-phenol (C8H11NO) are measured by a precision automated adiabatic calorimeter over the temperature range from 78 to 400 K. A polynomial equation of heat capacities as a function of the temperature was fitted by the least square method. Based on the fitted polynomial, the smoothed heat capacities and thermodynamic functions of the compound relative to the standard reference temperature 298.15K were calculated and tabulated at the interval of 5K. The energy equivalent, εcalor, of the oxygen-bomb combustion calorimeter has been determined from 0.68g of NIST 39i benzoic acid to be εcalor=(14674.69±17.49)J·K^-1. The constant-volume energy of combustion of the compound at T=298.15 K was measured by a precision oxygen-bomb combustion calorimeter to be ΔcU=-(32374.25±12.93)J·g^-1. The standard molar enthalpy of combustion for the compound was calculated to be ΔcHm = -(4445.47 ± 1.77) kJ·mol^-1 according to the definition of enthalpy of combustion and other thermodynamic principles. Finally, the standard molar enthalpy of formation of the compound was derived to be ΔfHm(C8H11NO, s)=-(274.68 ±2.06) kJ·mol^-1, in accordance with Hess law. 展开更多
关键词 4-(2-aminoethyl)-phenol adiabatic calorimetry low-temperature heat capacity standard molar enthalpy of formation
下载PDF
A Study on the Application of National Competency Standards(NCS)to 4-year Universities in South Korea—Focused on the Case of K-Univ.-
8
作者 Su-Won Kim Kyu-Suk Chung 《Journalism and Mass Communication》 2018年第1期22-34,共13页
In South Korea,the vocational education and training institutions,such as the vocational colleges,the vocational high schools,and the vocational training institutions is applying the National Competency Standards(NCS)... In South Korea,the vocational education and training institutions,such as the vocational colleges,the vocational high schools,and the vocational training institutions is applying the National Competency Standards(NCS).NCS is function as a key link in development of the human resource development(HRD),linking work,education and training,and qualifications by analyzing and presenting systematically the job demands of the industrial field.The 4-year universities that focus generally on the theoretical studies do not yet have applied NCS in South Korea.However,in the case of 4-year universities,the importance of professional education is emphasized by being derived and independed from more precise the individual science through the advancement of science and technology,and the division of social functions.Therefore,it is desirable to apply NCS to improve the practical expertise of 4-year university students.For this purpose,this study aims to compare the curriculum of national K-University and the NCS contents,and to find out how to apply it to the curriculum of 4-year universities in order to bring about the functions and the characteristics of education and training. 展开更多
关键词 NATIONAL COMPETENCY standards(NCS) 4-year UNIVERSITIES curriculum application
下载PDF
气相色谱法测定2-甲基-4-氯苯酚反应液中6种组分含量
9
作者 张晓霞 夏雪强 +3 位作者 王艳 崔庆霞 王瑞菲 岳涛 《化工科技》 CAS 2023年第3期58-64,共7页
采用气相色谱法测定2-甲基-4-氯苯酚反应液中6种组分的含量。通过优化色谱条件,样品中6种待测组分经TG 1701MS毛细管柱分离,使用氢火焰离子化检测器(FID)检测,以对甲酚为内标物,采用内标法定量,2-氯-6-甲基苯酚、邻甲酚(原料)、对甲酚(... 采用气相色谱法测定2-甲基-4-氯苯酚反应液中6种组分的含量。通过优化色谱条件,样品中6种待测组分经TG 1701MS毛细管柱分离,使用氢火焰离子化检测器(FID)检测,以对甲酚为内标物,采用内标法定量,2-氯-6-甲基苯酚、邻甲酚(原料)、对甲酚(内标)、2,4-二氯-6-甲基苯酚、2-甲基-3-氯苯酚、2-甲基-4-氯苯酚(产物)、2-甲基-5-氯苯酚与相邻色谱峰分离较好,在测定浓度下有良好的线性关.系,线性相关系数r均大于0.999;方法的回收率为97%~105%,相对标准偏差RSD<3%,符合分析方法的要求。该分析方法操作简便、准确度高,可为2-甲基-4-氯苯酚的工艺优化和中控分析提供有效数据。 展开更多
关键词 气相色谱法 内标法 2-甲基-4-氯苯酚 反应液
下载PDF
Announcement of Newly Approved National Standards of P.R.China 2009 No.4 (total No.144)
10
《China Standardization》 2010年第1期48-81,共34页
General Administration of Quality Supervision, Inspection and Quarantine of P.R. China and Standardization Administration of China and Standardization Administration of China have approved the following 314 national s... General Administration of Quality Supervision, Inspection and Quarantine of P.R. China and Standardization Administration of China and Standardization Administration of China have approved the following 314 national standards. 展开更多
关键词 GB total No.144 Announcement of Newly Approved National standards of P.R.China 2009 No.4
下载PDF
Low-Cost 4-20 mA Loop Calibrator
11
作者 Joel Arumun Emmanuel Eronu 《Journal of Flow Control, Measurement & Visualization》 2023年第3期49-63,共15页
Instrument calibration is vital to a successful control system because signal inputs to the system controllers come from such instruments. This paper presents a method for actualizing a standard low-cost loop calibrat... Instrument calibration is vital to a successful control system because signal inputs to the system controllers come from such instruments. This paper presents a method for actualizing a standard low-cost loop calibrator for the famous 4-20 mA electrical signaling scheme. The loop calibrator generates a linear current signal from 4 to 20 mA over a 250 ? typical process instrument load for calibration. The realization of the loop calibrator relies on a voltage-to-current converter to build a constant current source. The voltage controlled constant current source is built from discrete components and an op-amp to keep the cost low. Results from simulations and the prototype demonstrate the performance of the 4-20 mA loop calibrator which utilizes a greatly reduced number of components. The cost of these components is approximately 34% of the least expensive calibrator sampled, though other production costs are not included. This conclusion reinforces the fact that loop calibrators can be cheaper. 展开更多
关键词 INSTRUMENTS CALIBRATION 4-20 mA standard Loop Calibrator
下载PDF
恶性肿瘤风险指数、国际卵巢肿瘤分析组织简易标准联合血清CA125、HE4检测在卵巢肿瘤定性诊断中的效能
12
作者 张文栋 《中国民康医学》 2023年第13期130-132,136,共4页
目的:分析恶性肿瘤风险指数(RMI)、国际卵巢肿瘤分析组织(IOTA)简易标准联合血清糖类抗原125(CA125)、人附睾蛋白4(HE4)检测在卵巢肿瘤定性诊断中的效能。方法:选取2020年1月至2021年12月该院收治的100例卵巢肿瘤患者进行前瞻性研究,检... 目的:分析恶性肿瘤风险指数(RMI)、国际卵巢肿瘤分析组织(IOTA)简易标准联合血清糖类抗原125(CA125)、人附睾蛋白4(HE4)检测在卵巢肿瘤定性诊断中的效能。方法:选取2020年1月至2021年12月该院收治的100例卵巢肿瘤患者进行前瞻性研究,检测患者血清CA125、HE4水平,联合RMI、IOTA简易标准进行评估,以病理诊断结果为金标准,分析RMI、IOTA简易标准联合血清CA125、HE4单项及联合检测在卵巢肿瘤定性诊断中的效能。结果:病理诊断结果显示,100例卵巢肿瘤患者中恶性35例,良性65例;血清CA125检测检出恶性22例,良性46例;血清HE4检测检出恶性23例,良性46例;RMI检出恶性24例,良性47例;IOTA简易标准检出恶性23例,良性47例;RMI、IOTA简易标准、血清CA125、HE4联合检测在卵巢肿瘤定性诊断中的灵敏度、特异度、准确度、阳性预测值、阴性预测值均高于各单项检测,差异有统计学意义(P<0.05)。结论:RMI、IOTA简易标准、血清CA125、HE4联合检测在卵巢肿瘤定性诊断中的效能高于各单项检测。 展开更多
关键词 糖类抗原125 人附睾蛋白4 恶性肿瘤风险指数 国际卵巢肿瘤分析组织简易标准 卵巢肿瘤 诊断 效能
下载PDF
“四得当”范式作为标准制定的共同基础研究
13
作者 黄永军 《中国标准化》 2024年第16期40-44,49,共6页
“四得当”范式是对事物要素、结构、环境、功能相互关系的结构化表达,并包含了事物演化的得当取向,对完满认知事物和有效开展实践提供了整体框架。本文将这一普适范式与标准化实际相结合,特别是把它作为各种标准制定的共同基础,发现对... “四得当”范式是对事物要素、结构、环境、功能相互关系的结构化表达,并包含了事物演化的得当取向,对完满认知事物和有效开展实践提供了整体框架。本文将这一普适范式与标准化实际相结合,特别是把它作为各种标准制定的共同基础,发现对于夯实标准系统观基础、统一认知标准、提升标准审视意识和完满标准结构,以及对于提升综合标准化水平和贯标效果等具有积极意义。 展开更多
关键词 “四得当”范式 标准制定 共同基础 意义
下载PDF
Announcement of Newly Approved National Standards of P.R.China 2008 No.4(total No.117)
14
《China Standardization》 2008年第3期53-53,共1页
General Administration of Quality Supervision,Inspection and Quarantine of P.R. China and Standardization Administration of China have approved the following 3 national standards and publicize now.
关键词 Announcement of Newly Approved National standards of P.R.China 2008 No.4 total No.117
全文增补中
建设4亿亩高标准基本农田的思考与建议 被引量:79
15
作者 刘新卫 李景瑜 赵崔莉 《中国人口·资源与环境》 CSSCI 北大核心 2012年第3期1-5,共5页
近年来,高标准基本农田建设日益受到党中央和国务院的高度重视,大规模建设高标准基本农田已经上升为国家层面的战略部署和总体安排。"十二五"时期我国将在已有基础上再建成4亿亩旱涝保收高标准基本农田,此举对于增强我国粮食... 近年来,高标准基本农田建设日益受到党中央和国务院的高度重视,大规模建设高标准基本农田已经上升为国家层面的战略部署和总体安排。"十二五"时期我国将在已有基础上再建成4亿亩旱涝保收高标准基本农田,此举对于增强我国粮食安全保障能力、加快我国农业现代化发展,以及深化和扩展耕地数量、质量和生态全面管护内涵等具有重要意义。在"十二五"时期要实现既定目标,既面临着建设任务艰巨、资金存在缺口、监管难度较大等困难和挑战,但也具备较为扎实的工作基础,如初步建立了较为科学合理的工作机制、部署开展了各级土地整治规划、颁布出台了相关规章制度等。为确保"十二五"期间完成4亿亩高标准基本农田建设任务,文章建议通过积极主动的统筹谋划、大胆务实的改革创新,加快推进这项工作,主要包括:加快编制实施地方各级土地整治规划、健全高标准基本农田建设的工作机制、创新土地整治资金的使用和管理机制,以及加大高标准基本农田建设的监管力度等。 展开更多
关键词 基本农田 高标准 4亿亩 十二五时期
下载PDF
H.264编码器中1/4像素精度插值算法的VLSI实现 被引量:4
16
作者 陈光化 翟海华 +2 位作者 石旭利 张兆杨 万芬芳 《微电子学与计算机》 CSCD 北大核心 2008年第2期176-180,共5页
H.264视频编码标准中引入了1/4像素精度插值算法,大大提高了压缩效率,但同时使运算复杂度增加、存储带宽增大。针对以上问题,从运动估计的角度出发,采用一步插值法和数据复用技术,可使带宽减少26%,处理周期可减少45%;设计了相应的硬件结... H.264视频编码标准中引入了1/4像素精度插值算法,大大提高了压缩效率,但同时使运算复杂度增加、存储带宽增大。针对以上问题,从运动估计的角度出发,采用一步插值法和数据复用技术,可使带宽减少26%,处理周期可减少45%;设计了相应的硬件结构:采用了5级流水线实现一步插值算法,通过输入缓冲单元实现了参考数据的复用;针对插值过程中产生的大量数据,采用乒乓操作结构,保证数据及时传递。该结构可以显著降低带宽,提高吞吐率,完全可以应用于实时编码器中。 展开更多
关键词 H.264标准 1/4像素插值 4数据复用
下载PDF
MPEG-4实时视频传输的拥塞控制算法的改进 被引量:1
17
作者 刘国柱 王洪林 《微型机与应用》 2010年第5期39-41,44,共4页
提高视频图像的传输质量是网络拥塞控制方面的重要研究课题,在阐述了码率控制技术和实时视频传输的构架后,分析了基于丢包率和双丢包率阈值门限的拥塞控制机制以及VM8码率控制算法,指出了VM8码率控制算法的不足,所在并进行了相应的改进... 提高视频图像的传输质量是网络拥塞控制方面的重要研究课题,在阐述了码率控制技术和实时视频传输的构架后,分析了基于丢包率和双丢包率阈值门限的拥塞控制机制以及VM8码率控制算法,指出了VM8码率控制算法的不足,所在并进行了相应的改进。根据当前丢包率,对未来的发送速率的变化做出预测,从而动态地决定缓冲区目标水位参数,使得改进后的算法对发送速率具有一定的预测性。实验证明,改进后的算法有效地提高了编码后的图像质量。 展开更多
关键词 mepg-4标准 VM8算法 码率控制 编码器缓冲区
下载PDF
TMS320C6416T的MPEG-4编码优化 被引量:2
18
作者 李桂菊 陈秋萍 +2 位作者 纪华 武治国 刘艳滢 《光学精密工程》 EI CAS CSCD 北大核心 2009年第12期3096-3102,共7页
MPEG-4是当前最具影响的多媒体数据压缩编码国际标准。针对视频编码过程中计算复杂度高,系统运算量大等特点,本文提出了在TMS320C6416T上实现MPEG-4编码的优化方法。为使MPEG-4编码器达到实时应用的要求,结合C64x DSP的特点,采取了一系... MPEG-4是当前最具影响的多媒体数据压缩编码国际标准。针对视频编码过程中计算复杂度高,系统运算量大等特点,本文提出了在TMS320C6416T上实现MPEG-4编码的优化方法。为使MPEG-4编码器达到实时应用的要求,结合C64x DSP的特点,采取了一系列软件优化方法,包括合理分配存储器,在内存开辟双缓冲区结构,用汇编程序实现MPEG-4的核心算法以及对整个程序流程进行C语言级优化等。实验结果表明,该编码器可以对768 pixel×576 pixel,25 frame/s的视频图像进行实时编码。 展开更多
关键词 视频压缩 MPEG-4标准 TMS320C6416T 软件优化
下载PDF
2-氨基-4,6-二甲基嘧啶与锌盐配合物的制备及生成焓测定(英文) 被引量:2
19
作者 陈三平 魏青 +1 位作者 焦宝娟 高胜利 《无机化学学报》 SCIE CAS CSCD 北大核心 2003年第8期885-890,共6页
The complexes of zinc chloride and zinc nitrate with 2 amino 4,6 dimethyl pyrimidine (ADMP) were prepared through reflux in alcohol. The compositions of the complexes Zn(ADMP)2Cl2 (b) and Zn(ADMP)2(NO3)2·4H2O (c)... The complexes of zinc chloride and zinc nitrate with 2 amino 4,6 dimethyl pyrimidine (ADMP) were prepared through reflux in alcohol. The compositions of the complexes Zn(ADMP)2Cl2 (b) and Zn(ADMP)2(NO3)2·4H2O (c) were determined by chemical and elemental analyses. The complexes were characterized by IR, XPS, 1H NMR and TG DTG techniques. The constant volume combustion energies of ADMP and the complexes, ΔcE, were determined by a precise rotating bomb calorimeter at 298.15K. They were (-3664.53±1.18)kJ·mol-1, (-7130.94±3.69)kJ·mol-1, and (-7637.87±5.71)kJ·mol-1. Their standard enthalpies of combustion,, and standard enthalpies of formation, , were calculated. They were (-3666.39±1.18)kJ·mol-1, (-7129.70±3.69)kJ·mol-1, (-7632.91 ±5.71)kJ·mol-1 and (19.09±1.43)kJ·mol-1, (-411.96±4.03)kJ·mol-1, (-1153.28±6.02)kJ·mol-1. 展开更多
关键词 2-氨基-4 6-二甲基嘧啶 锌盐配合物 制备 生成焓 测定 氯化锌 硝酸锌 燃烧能
下载PDF
现场可编程门阵列参数化多标准高吞吐率基4Viterbi译码器 被引量:2
20
作者 夏飞 聂晶 +1 位作者 李荣春 王文涛 《国防科技大学学报》 EI CAS CSCD 北大核心 2016年第1期86-92,共7页
为了同时达到高性能和灵活性的目标,提出一种基于现场可编程门阵列的参数化多标准自适应基4 Viterbi译码器。译码器采用3~9可变约束长度,1/2、1/3可变码率,支持任意截断长度的纠错译码,并采用码字无符号量化、加比选单元设计优化和归一... 为了同时达到高性能和灵活性的目标,提出一种基于现场可编程门阵列的参数化多标准自适应基4 Viterbi译码器。译码器采用3~9可变约束长度,1/2、1/3可变码率,支持任意截断长度的纠错译码,并采用码字无符号量化、加比选单元设计优化和归一化判断逻辑分离策略优化关键路径设计,提高译码器工作频率。实验结果表明,该译码器能根据用户设定的参数改变结构,在多种通信标准之间实现动态切换;性能达到了541 Mbps,明显优于相关工作;对GPRS,Wi MAX,LTE,CDMA,3G等通信标准都取得了良好的误码性能,可满足多种通信标准的译码需求。 展开更多
关键词 现场可编程门阵列 VITERBI译码器 参数化 多标准 4
下载PDF