A clean method for preparing layered double hydroxides (LDHs) has been developed, featured by using the hydroxides of two different metals as starting materials by atom-economic reactions. The reactions were carried...A clean method for preparing layered double hydroxides (LDHs) has been developed, featured by using the hydroxides of two different metals as starting materials by atom-economic reactions. The reactions were carried out under hydrothermal conditions in either a high pressure autoclave or a microwave digester. The compositions, structural parameters and thermal behavior of the resulting LDHs are very similar to those of materials produced by using the separate nucleation and aging steps (SNAS) method. The major advantage of the new method is that no by-product is produced, so that filtration and washing processes are unnecessary. The consequent reduction in water consumption is beneficial to the environment.展开更多
Nano-sized hexagonal magnesium hydroxide (Mg(OH)2) with good dispersibility was synthesized by a double injection-hydrothermal method, utilizing polyvinylpyrrolidone (PVP) as an additive and with optimized proce...Nano-sized hexagonal magnesium hydroxide (Mg(OH)2) with good dispersibility was synthesized by a double injection-hydrothermal method, utilizing polyvinylpyrrolidone (PVP) as an additive and with optimized processing parameters. SEM and BET analysis showed that the mean particle size and specific surface area of the Mg(OH)2 particles were 174 nm and 50.77 m^2/g, respectively. The FT-IR spectra and the XRD patterns showed that PVP was adsorbed on the surface of the Mg(OH)2 crystal, thus effectively limiting particle agglomeration and hindering crystal growth along the (1 01 ) plane. TGA showed a decrease in the decomposition temperature and an increase in the weight loss of the Mg(OH)2 particles due to addition of PV/.展开更多
Objective To explore a highly sensitive and highly specific method to detect the serum MG7 antigen(Ag)level for early gastric cancer diagnosis.Methods The serum MG7-Ag level was detected by enzyme-linked immunosorbent...Objective To explore a highly sensitive and highly specific method to detect the serum MG7 antigen(Ag)level for early gastric cancer diagnosis.Methods The serum MG7-Ag level was detected by enzyme-linked immunosorbent assay(ELISA)method in 116 preoperative gastric cancer patients,63 postoperative gastric cancer patients,41 patients with precancerous lesion,37 pa-展开更多
文摘A clean method for preparing layered double hydroxides (LDHs) has been developed, featured by using the hydroxides of two different metals as starting materials by atom-economic reactions. The reactions were carried out under hydrothermal conditions in either a high pressure autoclave or a microwave digester. The compositions, structural parameters and thermal behavior of the resulting LDHs are very similar to those of materials produced by using the separate nucleation and aging steps (SNAS) method. The major advantage of the new method is that no by-product is produced, so that filtration and washing processes are unnecessary. The consequent reduction in water consumption is beneficial to the environment.
基金financial support of National Natural Science Foundation of China(Contract No. 21176266)
文摘Nano-sized hexagonal magnesium hydroxide (Mg(OH)2) with good dispersibility was synthesized by a double injection-hydrothermal method, utilizing polyvinylpyrrolidone (PVP) as an additive and with optimized processing parameters. SEM and BET analysis showed that the mean particle size and specific surface area of the Mg(OH)2 particles were 174 nm and 50.77 m^2/g, respectively. The FT-IR spectra and the XRD patterns showed that PVP was adsorbed on the surface of the Mg(OH)2 crystal, thus effectively limiting particle agglomeration and hindering crystal growth along the (1 01 ) plane. TGA showed a decrease in the decomposition temperature and an increase in the weight loss of the Mg(OH)2 particles due to addition of PV/.
文摘Objective To explore a highly sensitive and highly specific method to detect the serum MG7 antigen(Ag)level for early gastric cancer diagnosis.Methods The serum MG7-Ag level was detected by enzyme-linked immunosorbent assay(ELISA)method in 116 preoperative gastric cancer patients,63 postoperative gastric cancer patients,41 patients with precancerous lesion,37 pa-