Vitek 2 Compact和MicroScan WalkAway 40 SI检测MRSA的性能评价 被引量:8
1
作者 魏丹丹 刘洋 万腊根 《实验与检验医学》 CAS 2014年第5期505-507,共3页
目的评价Vitek 2 Compact和MicroScan WalkAway 40 SI两台全自动微生物鉴定仪检测耐甲氧西林金黄色葡萄球菌(MRSA)的性能。方法将临床分离的124株金黄色葡萄球菌随机分成39株和85株,分别用Vitek 2 COMPACT和MicroScan WalkAway 40 SI全... 目的评价Vitek 2 Compact和MicroScan WalkAway 40 SI两台全自动微生物鉴定仪检测耐甲氧西林金黄色葡萄球菌(MRSA)的性能。方法将临床分离的124株金黄色葡萄球菌随机分成39株和85株,分别用Vitek 2 COMPACT和MicroScan WalkAway 40 SI全自动微生物鉴定仪进行细菌鉴定及药敏分析,确认表型是否为MRSA;同时用PCR方法检测mecA及mecC基因以确定为MRSA;以PCR检测结果为金标准评价两台细菌分析仪检测MRSA的灵敏度、特异度和符合率。结果 Vitek 2 Compact和MicroScan WalkAway 40 SI检测MRSA的检出率分别为56.41%(22/39),51.76%(44/85);PCR方法检出mecA阳性菌株分别为22株、44株,均未检出mecC阳性菌株,即PCR法检测MRSA的检出率为分别为56.41%(22/39),51.76%(44/85);以PCR方法为金标准,则Vitek 2 Compact检测MRSA的灵敏度为95.45%,特异性为94.12%,符合率为94.87%;MicroScan WalkAway 40 SI检测MRSA的敏感度为93.18%,特异度为92.68%,符合率为92.94%。结论 Vitek 2COMPACT全自动微生物鉴定仪对MRSA的检出率、灵敏度、特异度和符合率均优于MicroScan WalkAway 40 SI,二者的差异无统计学意义(P>0.05),均可用于MRSA的检测。 展开更多
关键词 VITEK 2 COMPACT microscan WalkAway 40 SI MRSA 性能评价
下载PDF
MicroScan WalkAway仪器对碳青霉烯类耐药肠杆菌科细菌检测能力的评价 被引量:2
2
作者 赵志常 刘茂柏 +5 位作者 李彬 陈玮媛 张婧玲 黄丽雅 刘蕊 林齐立 《中国感染与化疗杂志》 CAS CSCD 北大核心 2017年第1期42-45,共4页
目的评价MicroScanWalkAway 96 Plus(MSW)全自动微生物分析仪在碳青霉烯类耐药肠杆菌科细菌(CRE)鉴定与预警中的指导价值。方法同时用PCR法和MSW系统检测福建医科大学附属协和医院实验室保存的81株CRE。以纸片扩散法和PCR法为金标准,比... 目的评价MicroScanWalkAway 96 Plus(MSW)全自动微生物分析仪在碳青霉烯类耐药肠杆菌科细菌(CRE)鉴定与预警中的指导价值。方法同时用PCR法和MSW系统检测福建医科大学附属协和医院实验室保存的81株CRE。以纸片扩散法和PCR法为金标准,比较该分析仪器对CRE菌株鉴定及预测是否产碳青霉烯酶的可靠性。结果 MSW判定CRE的符合率为69.1%(56/81)。PCR检测有48株细菌携带碳青霉烯类耐药基因;仪器法检测这些菌株时,高级专家系统(AES)预测产碳青霉烯酶的灵敏度为93.8%,特异度为42.4%,阳性预测值为70.3%,阴性预测值为82.4%,准确度为72.8%。结论 MSW系统对CRE具有较强的检测能力。 展开更多
关键词 microscan WalkAway 96 Plus仪器 碳青霉烯类耐药肠杆菌科细菌 高级专家系统
下载PDF
MicroScan AS-4自动微生物分析仪鉴定139株常见病原菌结果分析
3
作者 李忠新 周小梅 +1 位作者 李伟雄 陈萍 《上海医学检验杂志》 北大核心 2003年第2期86-86,共1页
关键词 microscan AS-4自动微生物分析仪 鉴定 病原菌
下载PDF
MicroScan快速真菌鉴定板的应用结果分析 被引量:1
4
作者 李光亮 《中国检验医学与临床》 2002年第1期22-22,共1页
关键词 快速真菌鉴定板 标本分离 菌种鉴定 药敏试验 细菌培养 微生物检验 microscan 抗生素
下载PDF
MicroScan AutoScan-4对凝固酶阴性葡萄球菌的鉴定及药敏分析
5
作者 曹海燕 陈国强 +1 位作者 廖惠贞 李鹤维 《中原医刊》 2002年第8期50-51,共2页
目的 :了解凝固酶阴性葡萄球菌 (CNS)的分离分布特点及其对 19种抗生素的敏感性 ,为临床合理用药提供依据。方法 :应用MicroScanAutoScan 4半自动微生物分析仪对 46株CNS进行鉴定、药敏试验 ,同时进行苯唑西林琼脂筛选试验和 β 内酰胺... 目的 :了解凝固酶阴性葡萄球菌 (CNS)的分离分布特点及其对 19种抗生素的敏感性 ,为临床合理用药提供依据。方法 :应用MicroScanAutoScan 4半自动微生物分析仪对 46株CNS进行鉴定、药敏试验 ,同时进行苯唑西林琼脂筛选试验和 β 内酰胺酶的检测。结果 :46株CNS中 ,表皮葡萄球菌占 39.1% ( 18/46 ) ,溶血葡萄球菌占 34.8% ( 16 /46 ) ,主要分布于痰液 ( 17/46 )、脓液及分泌物 ( 11/46 )和血液 ( 9/46 )。CNS产 β 内酰胺酶率为 95 .7% ( 4 4/46 )。耐苯唑西林CNS(MRCNS)的检出率为 6 9.6 % ( 32 /46 ) ,仅对万古霉素高度敏感 ,其次为呋喃妥因 ,敏感率分别为 10 0 %和 93.8%。苯唑西林敏感CNS(MSCNS)对万古霉素、呋喃妥因、头孢唑啉和阿莫西林 /棒酸敏感性最高 ,敏感率分别为 10 0 %、10 0 %、10 0 %和 92 .9%。结论 :临床分离到的CNS以表皮、溶血葡萄球菌为主 ,在痰液标本中分布最高。CNS高产 β 内酰胺酶。MRCNS呈多重耐药性 ,治疗首选万古霉素。MSCNS治疗宜选头孢唑啉、苯唑西林和阿莫西林 /棒酸等含酶抑制剂的复合药。 展开更多
关键词 microscan AutoScan-4 凝固酶阴性葡萄球菌 药物敏感试验 鉴定
下载PDF
MicroScan WA96微生物分析仪鉴定非发酵菌的评价
6
作者 罗永慧 甘雪华 江莎莎 《江西医学检验》 2007年第3期269-269,248,共2页
非发酵革兰阴性菌是指一群不利用葡萄糖或仪以氧化形式利用葡萄糖、需氧或兼性厌氧、无芽胞的革兰阴性杆菌。该类菌株在临床标本中的分离率及其耐药率均有增加的趋势.且此类菌在鉴定上较为复杂。我们以法国梅里埃公司的细菌鉴定条板API... 非发酵革兰阴性菌是指一群不利用葡萄糖或仪以氧化形式利用葡萄糖、需氧或兼性厌氧、无芽胞的革兰阴性杆菌。该类菌株在临床标本中的分离率及其耐药率均有增加的趋势.且此类菌在鉴定上较为复杂。我们以法国梅里埃公司的细菌鉴定条板API-20NE为参照.对MicroScan WalkAway96微生物分析仪系统作进行非发酵菌鉴定中的准确性进行评估。 展开更多
关键词 microscan 微生物分析仪 细菌鉴定 非发酵菌 革兰阴性杆菌 革兰阴性菌 临床标本 葡萄糖
下载PDF
Microscan AS-4自动微生物分析仪在细菌室间质控中的评价 被引量:11
7
作者 张鑫海 《上海医学检验杂志》 2000年第1期22-23,共2页
应用 Microscan AS- 4(以下简称为 AS- 4)自动微生物鉴定 /药敏测试系统 ,对细菌室间质评中的 39株不同质控菌株进行鉴定 ,并作了 110对次平行药敏试验。AS- 4对质控菌株鉴定的总正确率为 89.7%。对肠杆菌科、非发酵菌、苛养菌、弧菌科... 应用 Microscan AS- 4(以下简称为 AS- 4)自动微生物鉴定 /药敏测试系统 ,对细菌室间质评中的 39株不同质控菌株进行鉴定 ,并作了 110对次平行药敏试验。AS- 4对质控菌株鉴定的总正确率为 89.7%。对肠杆菌科、非发酵菌、苛养菌、弧菌科以及葡萄球菌、链球菌属鉴定具有较稳定的良好效果 ;对真菌 (酵母菌 )、李斯特菌属鉴定较局限 ;对马红球菌、棒状杆菌属不能鉴定。对沙门菌属、志贺菌属仍须借助血清学分型鉴定。 AS- 4检测的 MIC与质控测定菌株药敏靶值的完全符合率达 98.2 % ,比药敏纸片的 K- B法测定符合率略高。 展开更多
关键词 微生物分析仪 药敏试验 细菌室间质评 抗生素
下载PDF
Subpixel Reconstruction Algorithm in Staring FPA Nonuniform Microscan Imaging
8
作者 陈翼男 金伟其 +1 位作者 赵磊 赵琳 《Journal of Beijing Institute of Technology》 EI CAS 2008年第4期455-461,共7页
For the nonuniform microscan system where the interframe translation is no longer equivalent to accurate halfpixel, a 2-dimension non-interpolated subpixel algorithm is proposed to consider arhitrary value of microsca... For the nonuniform microscan system where the interframe translation is no longer equivalent to accurate halfpixel, a 2-dimension non-interpolated subpixel algorithm is proposed to consider arhitrary value of microscanning. The aim of the proposed algorithm is to restore double resolution from 2 × 2 undersampled frames. To solve the ill-posed problem in the process of image reconstruction, the prior boundary condition is introduced, and the proposed subpixel reconstruction algorithm is reformulated into the form of line-by-line backward propagation iteration for reducing the calculation complexity. Since the direction of movement offset relative to the accurate halfpixel determines the transfer matrix of the image degradation process, the recon- struction is classified into 4 types when 2 × 2 mieroscan model is applied. All the simulation results and experiment data demonstrate the double resolution improvement compared with the undersampled images. The focus problem, scarcely any possibility of the operation with accurate halfpixel micromotion, is figured out for en-hancing the feasibility of subpixel reconstruction used in practice. 展开更多
关键词 microscan image reconstruction infrared imaging subpixel resolution.
下载PDF
Oversample Reconstruction Based on a Strong Inter-Diagonal Matrix for an Optical Microscanning Thermal Microscope Imaging System
9
作者 Meijing Gao Ailing Tan +3 位作者 Jie Xu Weiqi Jin Zhenlong Zu Ming Yang 《Journal of Beijing Institute of Technology》 EI CAS 2018年第1期65-73,共9页
Based on a strong inter-diagonal matrix and Taylor series expansions,an oversample reconstruction method was proposed to calibrate the optical micro-scanning error. The technique can obtain regular 2 ×2 microscan... Based on a strong inter-diagonal matrix and Taylor series expansions,an oversample reconstruction method was proposed to calibrate the optical micro-scanning error. The technique can obtain regular 2 ×2 microscanning undersampling images from the real irregular undersampling images,and can then obtain a high spatial oversample resolution image. Simulations and experiments show that the proposed technique can reduce optical micro-scanning error and improve the system's spatial resolution. The algorithm is simple,fast and has low computational complexity. It can also be applied to other electro-optical imaging systems to improve their spatial resolution and has a widespread application prospect. 展开更多
关键词 optical microscanning strong inter-diagonal matrix oversample reconstruction thermal microscope imaging system
下载PDF
Microscan助力汽车生产全程质量跟踪
10
《航空制造技术》 2008年第14期105-106,共2页
先进的发动机生产基地发动机性能的好坏直接影响汽车的质量和性能。如果可以对发动机的核心零部件进行全程跟踪,那么对于制造商和消费者而言,效益都是不可估量的。而在位于柳州的新发动机工厂内。
关键词 microscan 发动机生产 核心零部件 质量跟踪 发动机性能 全自动生产线 条码技术 二维影像
下载PDF
Microscan收购西门子机器视觉业务部
11
作者 依然 《航空制造技术》 2008年第21期76-76,共1页
2008年10月,Microscan宣布它已经收购了总部位于美国新罕布什尔州Nashua的西门子公司机器视觉业务部,即以前的Acuity CiMatrix公司。据Mi-croscan公司预期,此次收购将通过把其业务扩展到机器视觉成像与检查领域,以进一步加强它在以客户... 2008年10月,Microscan宣布它已经收购了总部位于美国新罕布什尔州Nashua的西门子公司机器视觉业务部,即以前的Acuity CiMatrix公司。据Mi-croscan公司预期,此次收购将通过把其业务扩展到机器视觉成像与检查领域,以进一步加强它在以客户为中心的可追踪性解决方案方面的技术领先地位。此次收购已于2008年9月完成。 展开更多
关键词 机器视觉 microscan 西门子公司 新罕布什尔州 可追踪性 技术领先地位 技术专长 智能相机
下载PDF
15英寸液晶显示器 ADI MicroScan i600
12
作者 刘建云 《电子测试》 2001年第5期152-152,共1页
ADI MicroScan i600 15英寸液晶显示器采用独特的无底座设计,使用空间完全根据用户的爱好自由搭配.另外,产品的体积为389 mm×307 mm×63mm,重量为4千克,和其它15英寸液晶显示器相比,这是相当小巧轻薄的产品,加上无底座设计,使... ADI MicroScan i600 15英寸液晶显示器采用独特的无底座设计,使用空间完全根据用户的爱好自由搭配.另外,产品的体积为389 mm×307 mm×63mm,重量为4千克,和其它15英寸液晶显示器相比,这是相当小巧轻薄的产品,加上无底座设计,使用户携带起来非常方便.i600采用15英寸主动式矩阵排列TFT液晶面板,可提供1024×768的屏幕分辨率,点距为0.297mm,垂直扫描频率为75Hz,显示器的亮度为200cd/m2,对比是250:1,水平视角120度、垂直视角100度,这和大多数的15英寸液晶显示器的规格差不多. 展开更多
关键词 液晶显示器 ADI microscan i600 计算机
下载PDF
心中梦已实现——ADI Microscan G710显示器试用手记
13
作者 天昊 《中国计算机用户》 2000年第42期58-58,共1页
记得曾经有一条显示器的广告如是说:“别让你的电脑没面子。”说实话,显示器的确是电脑中最不应该省钱的设备。这次我要给大家介绍一款最能让你的电脑有“面子”的设备—ADI G710纯平显示器。如果你觉得现在使用的显示器图像太小,色彩... 记得曾经有一条显示器的广告如是说:“别让你的电脑没面子。”说实话,显示器的确是电脑中最不应该省钱的设备。这次我要给大家介绍一款最能让你的电脑有“面子”的设备—ADI G710纯平显示器。如果你觉得现在使用的显示器图像太小,色彩不自然或者画面不稳定,那么恭喜你,把它换掉的时候已经到了。 展开更多
关键词 USB 接口 显像管 ADI microscan G710 屏幕显示
下载PDF
三维显示器——ADI MicroScan M510
14
作者 王欣 《电子与电脑》 2000年第12期34-34,共1页
刚看到文章的标题时您可能会产生疑问,依靠硬件就能对显示器中显示的任何图像产生三维效果?如果在以前,认为这是可能的人一定会被称作是疯子。随着科技的飞速发展,这一愿望已经变成了现实。PC Computing易用性实验室评测的ADI MicroS... 刚看到文章的标题时您可能会产生疑问,依靠硬件就能对显示器中显示的任何图像产生三维效果?如果在以前,认为这是可能的人一定会被称作是疯子。随着科技的飞速发展,这一愿望已经变成了现实。PC Computing易用性实验室评测的ADI MicroScan M510显示器就可以通过3D-100套件让其上的画面显示出令人满意的三维效果。 展开更多
关键词 三维显示器 显像管 测试 分辨率 刷新率 ADI microscan M510
下载PDF
色彩丰富、层次感强 Adi MicroScan A6
15
作者 刘建云 《电子测试》 2002年第6期73-73,共1页
外形美观、小巧轻薄,并且具有较大的亮度和对比度,显示效果不错。
关键词 Adi microscan A6 液晶显示器 技术指标
下载PDF
17英寸图像美工专用传统显示器 ADI MicroScan G710
16
作者 林阿岚 《电子测试》 2001年第5期137-137,共1页
大家对于ADI MicroScan G710显示器的名字可能有点陌生,其实这款显示器就是诚洲所推出的真平17显示器.MicroScan G710内置微处理器和数字式面板操控设计,让每位使用者可以轻易地控制显示器.采用Sony全平面特丽珑显像管,克服了传统CRT的... 大家对于ADI MicroScan G710显示器的名字可能有点陌生,其实这款显示器就是诚洲所推出的真平17显示器.MicroScan G710内置微处理器和数字式面板操控设计,让每位使用者可以轻易地控制显示器.采用Sony全平面特丽珑显像管,克服了传统CRT的四角失真及反光现象,0.24mm点距,可以让画面表现出细腻的对比显像效果. 展开更多
关键词 ADI microscan G710 直平显示器 计算机 全平面特丽珑显像管
下载PDF
MicroScan微生物分析仪英文报告汉化的一种解决方案
17
作者 李劲松 《医疗设备信息》 2002年第8期23-24,共2页
本文针对MicroScan微生物分析仪英文报告的汉化问题提出了一种较为简便可行的解决方案 ,给出了其中关键的数据检索程序的设计说明和程序清单 。
关键词 microscan微生物分析仪 英文报告 汉化 数据检索 程序设计
下载PDF
MICROSCAN固定式扫描器走进我国工业生产线
18
作者 郭哲明 《条码与信息系统》 2001年第6期41-41,共1页
关键词 扫描器 microscan 生产线
下载PDF
小、快、易——MICROSCAN(迈思肯)新产品MicroHAWK发布
19
作者 本刊讯 《自动化博览》 2015年第10期3-3,共1页
〈本刊讯〉2015年9月14日,MICROSCAN(迈思肯)新产品Micro HAWK发布会在北京召开。发布会由迈思肯大中华区经理程夷武主持,首席执行官夏明伟亲临现场讲解。近20家媒体参加了此次发布会。迈思肯此次发布的新产品Micro HAWK包括3款产品:... 〈本刊讯〉2015年9月14日,MICROSCAN(迈思肯)新产品Micro HAWK发布会在北京召开。发布会由迈思肯大中华区经理程夷武主持,首席执行官夏明伟亲临现场讲解。近20家媒体参加了此次发布会。迈思肯此次发布的新产品Micro HAWK包括3款产品:ID-20、ID-30和ID-40。 展开更多
关键词 机器视觉 自动识别 大中华区 夏明 microscan MicroHAWK 物联网 新产品发布会 软硬件产品 二维码
下载PDF
MicroScan革兰阳性复合板检测葡萄球菌属诱导型克林霉素耐药的应用 被引量:1
20
作者 傅石明 《中华医院感染学杂志》 CAS CSCD 北大核心 2012年第6期1313-1314,共2页
目的评价MicroScan革兰阳性复合板检测葡萄球菌属诱导型克林霉素耐药的临床应用价值。方法用MicroScan微生物鉴定药敏分析仪检测203株葡萄球菌属细菌对克林霉素和红霉素的耐药性;在做药敏鉴定的同时,用已灭菌的微量加样器吸取1μg/ml克... 目的评价MicroScan革兰阳性复合板检测葡萄球菌属诱导型克林霉素耐药的临床应用价值。方法用MicroScan微生物鉴定药敏分析仪检测203株葡萄球菌属细菌对克林霉素和红霉素的耐药性;在做药敏鉴定的同时,用已灭菌的微量加样器吸取1μg/ml克林霉素孔55μl菌液弃去,再吸取红霉素4μg/ml孔菌液55μl于1μg/ml克林霉素孔检测诱导克林霉素耐药;每株细菌均以双纸片法D-试验作对照。结果 203株葡萄球菌属中有86株对红霉素耐药而克林霉素敏感,占42.4%;其中D-试验阳性54株,诱导型克林霉素耐药菌株的检出率为62.8%;D试验阳性菌株MicroScan革兰阳性复合板检测53株阳性,两者符合率为98.8%。结论 MicroScan革兰阳性复合板可直接检测诱导克林霉素耐药。 展开更多
关键词 microscan革兰阳性复合板 葡萄球菌属 诱导型克林霉素耐药
原文传递