Optimization Algorithm for Operation Comfortability of Master Manipulator of Minimally Invasive Surgery Robot 被引量:2
1
作者 李进华 王雪生 +3 位作者 邢元 王树新 李建民 梁科 《Transactions of Tianjin University》 EI CAS 2016年第2期95-104,共10页
To evaluate the operation comfortability in the master-slave robotic minimally invasive surgery(MIS), an optimal function was built with two operation comfortability decided indices, i.e., the center distance and volu... To evaluate the operation comfortability in the master-slave robotic minimally invasive surgery(MIS), an optimal function was built with two operation comfortability decided indices, i.e., the center distance and volume contact ratio. Two verifying experiments on Phantom Desktop and Micro Hand S were conducted. Experimental results show that the operation effect at the optimal relative location is better than that at the random location, which means that the optimal function constructed in this paper is effective in optimizing the operation comfortability. 展开更多
关键词 mis robot master manipulator operation comfortability Phantom Desktop Micro Hand S
下载PDF
Method for Latency Measurement of Visual Feedback-Based Master–Slave Minimally Invasive Surgical Robot 被引量:1
2
作者 Jinhua Li Jingchao Shen +2 位作者 He Su Shuxin Wang Jianmin Li 《Transactions of Tianjin University》 EI CAS 2018年第4期375-386,共12页
To measure the latency between human motion stimulation and stereo image display response in a visual feedback-based minimally invasive surgical(MIS) robotic system,a method was proposed by comparing the orientations ... To measure the latency between human motion stimulation and stereo image display response in a visual feedback-based minimally invasive surgical(MIS) robotic system,a method was proposed by comparing the orientations of input and output events through image-processing technology. This method used a black bar to keep pace with the measured joint rotating at a number of speeds. During tests,an external camera was placed in front of the apparatus with a proper visual field,so that it can simultaneously view orientations of both bars fixed on the corresponding joints. After quantitatively analyzing the accuracy of the proposed measurement method,the method was applied to a visual feedback-based master–slave robotic system with two-degrees-of-freedom. Experimental results show that the latency of the overall system was approximately 250 ms,and the opposite clearance of the measured joint was in the range of 1.7°–1.9°. 展开更多
关键词 MINIMALLY INVASIVE surgical(mis)robot LATENCY measurement Real time Visual feedback