期刊文献+
共找到120篇文章
< 1 2 6 >
每页显示 20 50 100
Acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction 被引量:9
1
作者 Li Yi-Ling Ma Qing-Yu +1 位作者 Zhang Dong Xia Rong-Min 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第8期263-270,共8页
An acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction (MAT-MI) is pro- posed, based on the analyses of one-dimensional tissue vibration, three-dimensional acoustic dipole radiatio... An acoustic dipole radiation model for magnetoacoustic tomography with magnetic induction (MAT-MI) is pro- posed, based on the analyses of one-dimensional tissue vibration, three-dimensional acoustic dipole radiation and acoustic waveform detection with a planar piston transducer. The collected waveforms provide information about the conductiv- ity boundaries in various vibration intensities and phases due to the acoustic dipole radiation pattern. Combined with the simplified back projection algorithm, the conductivity configuration of the measured layer in terms of shape and size can be reconstructed with obvious border stripes. The numerical simulation is performed for a two-layer cylindrical phantom model and it is also verified by the experimental results of MAT-MI for a tissue-like sample phantom. The proposed model suggests a potential application of conductivity differentiation and provides a universal basis for the further study of conductivity reconstruction for MAT-MI. 展开更多
关键词 magnetoacoustic tomography with magnetic induction acoustic dipole radiation beampattern biological tissues
下载PDF
Reception pattern influence on magnetoacoustic tomography with magnetic induction 被引量:4
2
作者 孙晓冬 王欣 +2 位作者 周雨琦 马青玉 章东 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第1期329-337,共9页
Based on the acoustic radiation theory of a dipole source, the influence of the transducer reception pattern is studied for magnetoacoustic tomography with magnetic induction(MAT-MI). Numerical studies are conducted... Based on the acoustic radiation theory of a dipole source, the influence of the transducer reception pattern is studied for magnetoacoustic tomography with magnetic induction(MAT-MI). Numerical studies are conducted to simulate acoustic pressures, waveforms, and reconstructed images with unidirectional, omnidirectional, and strong directional transducers.With the analyses of equivalent and projection sources, the influences of the model dimension and the layer effect are qualitatively analyzed to evaluate the performance of MAT-MI. Three-dimensional simulation studies show that the strong directional transducer with a large radius can reduce the influences of equivalent sources, projection sources, and the layer effect effectively, resulting in enhanced pressure and improved image contrast, which is beneficial for boundary pressure extraction in conductivity reconstruction. The reconstructed conductivity contrast images present the conductivity boundaries as stripes with different contrasts and polarities, representing the values and directions of the conductivity changes of the scanned layer. The favorable results provide solid evidence for transducer selection and suggest potential practical applications of MAT-MI in biomedical imaging. 展开更多
关键词 magnetoacoustic tomography with magnetic induction(MAT-MI) reception pattern projection source and equivalent source layer effects
下载PDF
Simulation research on effect of magnetic nanoparticles on physical process of magneto–acoustic tomography with magnetic induction 被引量:3
3
作者 Xiao-Heng Yan Ying Zhang Guo-Qiang Liu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第10期378-385,共8页
Magneto–acoustic tomography with magnetic induction(MAT-MI) is a multiphysics coupled imaging technique that is combined with electrical impedance tomography and ultrasound imaging. In order to study the influence ... Magneto–acoustic tomography with magnetic induction(MAT-MI) is a multiphysics coupled imaging technique that is combined with electrical impedance tomography and ultrasound imaging. In order to study the influence of adding magnetic nanoparticles as a contrast agent for MAT-MI on its physical process, firstly, we analyze and compare the electromagnetic and acoustical properties of MAT-MI theoretically before and after adding magnetic nanoparticles, and then construct a two-dimensional(2 D) planar model. Under the guidance of space-time separation theory, we determine the reasonable simulation conditions and solve the electromagnetic field and sound field physical processes in the two modes by using the finite element method. The magnetic flux density, sound pressure distribution, and related one-dimensional(1 D), 2 D, and three-dimensional(3 D) images are obtained. Finally, we make a qualitative and quantitative analysis based on the theoretical and simulation results. The research results show that the peak time of the time item separated from the sound source has a corresponding relationship with the peak time of the sound pressure signal. At this moment, MAMPTMI produces larger sound pressure signals, and the sound pressure distribution of the MAMPT-MI is more uniform, which facilitates the detection and completion of sound source reconstruction. The research results may lay the foundation for the MAT-MI of magnetically responsive nanoparticle in subsequent experiments and even clinical applications. 展开更多
关键词 magneto-acoustic tomography with magnetic induction magnetic nanoparticles magnetic flux density sound pressure
下载PDF
Second harmonic magnetoacoustic responses of magnetic nanoparticles in magnetoacoustic tomography with magnetic induction 被引量:1
4
作者 Gepu Guo Ya Gao +3 位作者 Yuzhi Li Qingyu Ma Juan Tu Dong Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第3期259-264,共6页
Due to the unique magnetic, mechanical and thermal properties, magnetic nanoparticles(MNPs) have comprehensive applications as the contrast and therapeutic agents in biomedical imaging and magnetic hyperthermia. The l... Due to the unique magnetic, mechanical and thermal properties, magnetic nanoparticles(MNPs) have comprehensive applications as the contrast and therapeutic agents in biomedical imaging and magnetic hyperthermia. The linear and nonlinear magnetoacoustic responses determined by the magnetic properties of MNPs have attracted more and more attention in biomedical engineering. By considering the relaxation time of MNPs, we derive the formulae of second harmonic magnetoacoustic responses(2H-MARs) for a cylindrical MNP solution model based on the mechanical oscillations of MNPs in magnetoacoustic tomography with magnetic induction(MAT-MI). It is proved that only the second harmonic magnetoacoustic oscillations can be generated by MNPs under an alternating magnetic excitation. The acoustic pressure of the 2H-MAR is proportional to the square of the magnetic field intensity and exhibits a linear increase with the concentration of MNPs. Numerical simulations of the 2H-MAR are confirmed by the experimental measurements for various magnetic field intensities and solution concentrations using a laser vibrometer. The favorable results demonstrate the feasibility of the harmonic measurements without the fundamental interference of the electromagnetic excitation, and suggest a new harmonic imaging strategy of MAT-MI for MNPs with enhanced spatial resolution and improved signal-to-noise ratio in biomedical applications. 展开更多
关键词 magnetoacoustic tomography with magnetic induction second HARMONIC magnetoacoustic RESPONSES magnetic nanoparticles magnetic force mechanical OSCILLATIONS
下载PDF
A Magnetic Induction Tomography System for Prospective Industrial Processing Applications 被引量:2
5
作者 Hsin-Yu Wei Manuchehr Soleimani 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2012年第2期406-410,共5页
Magnetic induction tomography(MIT) is one of the newest industrial process imaging techniques.Main industrial applications of the MIT imaging are in high conductive flow imaging.However,recently it has been shown that... Magnetic induction tomography(MIT) is one of the newest industrial process imaging techniques.Main industrial applications of the MIT imaging are in high conductive flow imaging.However,recently it has been shown that the MIT may be useful for low conductive process imaging.This paper presents a cost effective hardware design for MIT in industrial applications,called Bath-MKI industrial MIT system.The system comprises 8 inductor coils and has the possibility of expansion to 16 coils.The excitation signals and the measured voltages are generated and measured using a LabView based system.Two 16 by 1 multiplexers are used to select between the coils.Measurements,excitation and multiplexing are all controlled by a National Instrument(NI) USB based DAQ:USB-6259 and a signal generator.Using the same electronics,the prototype is tested with two different coil arrays;one is a small scale ferrite core coil and one larger scale air cored coil.Experimental image reconstruction results are shown using both small scale and large scale coil arrays. 展开更多
关键词 magnetic induction tomography coil sensors tbrward problem inyerse solver
下载PDF
Boundary normal pressure-based electrical conductivity reconstruction for magneto–acoustic tomography with magnetic induction 被引量:1
6
作者 郭各朴 丁鹤平 +1 位作者 戴思捷 马青玉 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第8期193-200,共8页
As a kind of multi-physics imaging approach integrating the advantages of electrical impedance tomography and ul- trasound imaging with the improved spatial resolution and image contrast, magneto-acoustic tomography w... As a kind of multi-physics imaging approach integrating the advantages of electrical impedance tomography and ul- trasound imaging with the improved spatial resolution and image contrast, magneto-acoustic tomography with magnetic induction (MAT-MI) is demonstrated to have the capability of electrical impedance contrast imaging for biological tissues with conductivity differences. By being detected with a strong directional transducer, abrupt pressure change is proved to be generated by the gradient of the induced Lorentz force along the force direction at conductivity boundary. A simplified boundary normal pressure (BNP)-based conductivity reconstruction algorithm is proposed and the formula for conductivity distribution inside the object with the clear physical meaning of pressure derivative, is derived. Numerical simulations of acoustic pressure and conductivity reconstruction are conducted based on a 2-layer eccentric cylindrical phantom model using Hilbert transform. The reconstructed two-dimensional conductivity images accord well with the model, thus success- fully making up the deficiency of only imaging conductivity boundary in traditional MAT-MI. The proposed method is also demonstrated to have a spatial resolution of one wavelength. This study provides a new method of reconstructing accurate electrical conductivity and suggests the potential applications of MAT-MI in imaging biological tissues with conductivity difference. 展开更多
关键词 magneto-acoustic tomography with magnetic induction boundary normal pressure conductivityreconstruction pressure derivative Hilbert transform
下载PDF
Key Algorithm on Medical Inter net of Things Sensor Node Based on Magnetic Induction Tomography
7
作者 Hu Xiaoyan Gao Peng Yuan Jie Ma Huaxing Yuan Jing 《China Communications》 SCIE CSCD 2012年第4期110-114,共5页
This paper focuses on the key issues of information processing in the new sensing technology-electromagnetic induction tomography and depth theoretical study and experimental simulation have been conducted.In this stu... This paper focuses on the key issues of information processing in the new sensing technology-electromagnetic induction tomography and depth theoretical study and experimental simulation have been conducted.In this study,Labview is used to drive the data acquisition card to control the signal generation and acquisition,and Matlab is used to achieve algorithms such as Fast Fourier Transformation (FFT) algorithm,relevant law algorithm and the classical method algorithm.The simulation results show this software system enables successful digital phase identification and the phase difference resolution of 0.10 can be achieved,which is consistent with theoretical analysis.It can also be seen that software system based on Labview and Matlab is a successful method to identify the phase difference in magnetic induction tomography system,which can meet the measurement needs of sensor nodes,laying the basis for the further development of medical IoT study. 展开更多
关键词 IOT sensor node magnetic induction tomography
下载PDF
基于改进目标场法梯度线圈的感应式磁声磁粒子浓度成像研究
8
作者 闫孝姮 淡新贤 +1 位作者 陈伟华 刘方田 《电工技术学报》 EI CSCD 北大核心 2024年第14期4305-4316,共12页
感应式磁声磁粒子浓度成像(MACT-MI)是一种基于磁声耦合效应的磁性纳米粒子(MNPs)浓度成像新方法。由于其磁声信号的信噪比低,导致系统成像质量不佳,该文提出一种改善MACT-MI信噪比的新思路:首先,基于经典目标场法(TFM)设计梯度线圈的思... 感应式磁声磁粒子浓度成像(MACT-MI)是一种基于磁声耦合效应的磁性纳米粒子(MNPs)浓度成像新方法。由于其磁声信号的信噪比低,导致系统成像质量不佳,该文提出一种改善MACT-MI信噪比的新思路:首先,基于经典目标场法(TFM)设计梯度线圈的思路,将最小化磁场相对误差定义为适应度函数,并采用鲸鱼优化算法对电流密度系数进行优化,设计了一种结构灵活、激励简单的高质量梯度磁场线圈;其次,为研究梯度磁场空间分布特征对MACT-MI的影响,该文构建不同的MNPs分布模型,并利用多物理场仿真软件COMSOL对MACT-MI的物理过程进行数值求解,得到成像区域的磁力和声压分布。仿真结果表明,磁力和声压的有效波动范围与梯度磁场均匀空间的大小成正比,且随着均匀空间的缩小,磁力和声压的峰值也随之衰减,通过提高磁场的均匀度可以有效提高磁声信号的信噪比,改善系统成像质量。研究结果可为成像装备的设计以及MACT-MI的后续实验应用提供研究基础。 展开更多
关键词 磁声磁粒子浓度成像 目标场法 梯度磁场 均匀空间
下载PDF
基于反投影的MIT动态图像重建方法研究 被引量:8
9
作者 柯丽 林筱 +1 位作者 杜强 赵璐璐 《仪器仪表学报》 EI CAS CSCD 北大核心 2013年第2期394-400,共7页
磁感应断层成像(magnetic induction tomography,MIT)是一种无创、非接触的新型医学成像技术,图像重建算法是实现MIT快速、精确成像的关键。提出一种改进的反投影图像重建算法,首先根据成像区域的磁场分布,由磁力线确定反投影路径,降低... 磁感应断层成像(magnetic induction tomography,MIT)是一种无创、非接触的新型医学成像技术,图像重建算法是实现MIT快速、精确成像的关键。提出一种改进的反投影图像重建算法,首先根据成像区域的磁场分布,由磁力线确定反投影路径,降低了直线反投影用于磁场成像的定位误差;其次根据MIT电磁关系推导,构建了边界检测数据的修正模型,据此对边界相位差数据进行修正处理,进一步提高了重建图像定位准确性;最后分别对成像区域内扰动目标电导率大小变化及位置变化2种情况,构建了序列重建图像,对该图像序列联合分析获取纵向阻抗变化信息,反映了成像体随时间变化的动态信息。实验结果表明该算法具有重建速度快、定位准确的特性,能够准确反映成像区域内部电导率变化,结合序列图像联合分析实现MIT动态成像。 展开更多
关键词 磁感应断层成像 图像重建 反投影算法 动态图像
下载PDF
MIT中反投影矩阵的计算与数据处理方法 被引量:10
10
作者 柯丽 曹冯秋 杜强 《仪器仪表学报》 EI CAS CSCD 北大核心 2014年第10期2256-2262,共7页
反投影算法是磁感应断层成像技术(MIT)中一种有效的图像重建算法。该算法中反投影矩阵的计算与检测数据的处理是提高重建图像质量的关键。依据磁感应断层像原理,提出了一种有效的MIT反投影矩阵计算方法和检测数据的处理方法。在所建立... 反投影算法是磁感应断层成像技术(MIT)中一种有效的图像重建算法。该算法中反投影矩阵的计算与检测数据的处理是提高重建图像质量的关键。依据磁感应断层像原理,提出了一种有效的MIT反投影矩阵计算方法和检测数据的处理方法。在所建立的仿真模型和实际模型基础上,分别运用该方法进行了图像重建实验与分析。实验结果表明,该方法应用在反投影算法中可以实现MIT图像重建。重建图像能准确反映成像区域内部电导率变化,具有较高分辨率,扰动目标定位准确,形状信息清晰可见。进而验证了该方法的可靠性和有效性。 展开更多
关键词 磁感应断层成像(mit) 反投影算法 反投影矩阵 检测数据
下载PDF
MIT单通道测量的电磁关系及脑组织电导率测量参数计算 被引量:11
11
作者 秦明新 焦李成 +3 位作者 李世俊 王聪 吕华 董秀珍 《第四军医大学学报》 北大核心 2004年第21期2007-2010,共4页
目的 :基于已完成的单通道测量MIT实验系统 ,根据理想物理模型 ,推导实验系统的电磁关系 ,为系统的优化设计和改进提供理论依据 .方法 :采用电磁感应理论、理想物理模型 ,得到特定频率下目标电导率与系统测量参数的关系 .结果 :获得了... 目的 :基于已完成的单通道测量MIT实验系统 ,根据理想物理模型 ,推导实验系统的电磁关系 ,为系统的优化设计和改进提供理论依据 .方法 :采用电磁感应理论、理想物理模型 ,得到特定频率下目标电导率与系统测量参数的关系 .结果 :获得了目标电导率与系统测量线圈电流相位和幅值变化的关系 ,并计算了目标电导率为头皮、颅骨、脑脊液、脑灰质、脑白质、脑水肿时的相位和幅值变化 .结论 :为了提高单通道测量MIT实验系统性能 ,应适当增加激励频率 ;精确提取参考线圈电流与测量线圈电流的相位差 ;选用高性能的鉴相器件 . 展开更多
关键词 脑组织 非接触测量 磁感应断层成像 电导率
下载PDF
新型功率可调MIT激励源设计及其磁场分析 被引量:5
12
作者 焦明克 秦明新 +5 位作者 梁文文 胡晓彦 张华 周伟 李克 李文哲 《医疗卫生装备》 CAS 2008年第2期15-17,20,共4页
目的:设计输出功率可调的MIT激励源和3种类型的激励线圈,以提高MIT相位检测的精度。方法:通过选取PA19放大器芯片,设计200 kHz工作频率下可调输出的功率放大电路;通过计算,设计制作了螺线管线圈和2种聚焦线圈;最终测试比较各激励线圈的... 目的:设计输出功率可调的MIT激励源和3种类型的激励线圈,以提高MIT相位检测的精度。方法:通过选取PA19放大器芯片,设计200 kHz工作频率下可调输出的功率放大电路;通过计算,设计制作了螺线管线圈和2种聚焦线圈;最终测试比较各激励线圈的磁场分布,并在不同激励线圈的磁场下对圆柱形铁块进行相位测试。结果:激励源输出峰值电流大于1 A,圆形螺旋聚焦线圈的磁场由线圈轴线向两边衰减斜率最大,约为0.06 T/cm,且在该激励线圈磁场中,对铁块的相位检测结果最大。结论:该激励源输出功率可调范围大,采用圆形螺旋聚焦线圈磁场聚焦效果最佳、相位检测效果最好。 展开更多
关键词 脑磁感应断层成像 聚焦线圈 磁场分布 相位检测
下载PDF
阈值Landweber在MIT图像重建中的应用 被引量:3
13
作者 王旭 王静文 王柯元 《东北大学学报(自然科学版)》 EI CAS CSCD 北大核心 2016年第4期477-480,共4页
针对目前磁感应成像技术的图像重建质量较低、速度较慢的问题,提出了一种阈值Landweber重建算法.该算法在Landweber算法的基础上设置门限阈值,并在每次迭代中都自适应地调节阈值参数,从而提高了重建图像质量且加快Landweber方法的收敛速... 针对目前磁感应成像技术的图像重建质量较低、速度较慢的问题,提出了一种阈值Landweber重建算法.该算法在Landweber算法的基础上设置门限阈值,并在每次迭代中都自适应地调节阈值参数,从而提高了重建图像质量且加快Landweber方法的收敛速度.在Comsol Multiphysics仿真软件建立MIT系统模型的基础上,利用有限元方法求解了正问题.模拟结果表明,利用阈值Landweber图像重建算法获得的图像质量比LBP、未添加阈值的Landweber图像重建算法要好,同时也加快了收敛速度. 展开更多
关键词 磁感应成像 图像重建 Landweber 门限阈值 有限元法
下载PDF
脑MIT单通道测量的正弦时变电磁场特性 被引量:4
14
作者 秦明新 焦李成 +3 位作者 吕华 李世俊 王聪 董秀珍 《第四军医大学学报》 北大核心 2004年第23期2172-2174,共3页
目的 :探讨脑磁感应断层成像 (MIT)单通道测量的正弦时变电磁场分布 .方法 :将头颅近似为一个双层的导电球体 ,脑MIT单通道测量系统近似为由测量、激励线圈和球体组成的轴对称模型 ,采用时谐电磁场分析方法 ,推导出轴对称模型的解析解 ... 目的 :探讨脑磁感应断层成像 (MIT)单通道测量的正弦时变电磁场分布 .方法 :将头颅近似为一个双层的导电球体 ,脑MIT单通道测量系统近似为由测量、激励线圈和球体组成的轴对称模型 ,采用时谐电磁场分析方法 ,推导出轴对称模型的解析解 .结果 :获得了脑MIT单通道测量系统电磁场分布特性和求解表达式 .结论 :为脑MIT单通道测量的正弦时变电磁场的分析和计算提供了一种解析方法 . 展开更多
关键词 正弦时变电磁场 磁感应断层成像
下载PDF
基于晶体振荡器的MIT系统激励源设计及其实现 被引量:4
15
作者 吕华 秦明新 +1 位作者 李世俊 王聪 《第四军医大学学报》 北大核心 2005年第10期944-947,共4页
目的: 设计一种应用于磁感应断层成像技术(mag neticinductiontomography,MIT)系统的10MHz高性能激励源,以提高MIT系统的测量精度. 方法: 根据高频电子电路设计原理及其电磁屏蔽技术,选用高频率精度和稳定性的恒温晶体振荡器,设计和实... 目的: 设计一种应用于磁感应断层成像技术(mag neticinductiontomography,MIT)系统的10MHz高性能激励源,以提高MIT系统的测量精度. 方法: 根据高频电子电路设计原理及其电磁屏蔽技术,选用高频率精度和稳定性的恒温晶体振荡器,设计和实现了高性能激励源.结果: 激励源稳定输出10MHz正弦信号,频率稳定度优于1×10-7水平,杂波抑制和谐波抑制分别达到90dBc和45dBc,负载时输出电压峰峰值为12V,最大输出功率为1 3W. 结论: 设计的激励源提供了高频率稳定性和高信噪比的激励信号,为高精度的MIT测量奠定了基础. 展开更多
关键词 磁感应断层成像 晶体振荡器 频率稳定性 激励源
下载PDF
基于锁定放大器的MIT相位检测及细胞实验 被引量:6
16
作者 梁文文 秦明新 +5 位作者 焦明克 杨浩 李克 焦腾 王文勇 周伟 《中国医学物理学杂志》 CSCD 2008年第4期744-747,753,共5页
目的:实现脑磁感应成像系统中的单通道高精度相位差检测功能。材料与方法:基于高精度鉴相器射频锁定放大器SR844建立了相位差检测单元,对磁感应信号进行放大、滤波处理,检测频率为1 MHz;通过培养SD大鼠的大脑皮质神经细胞,获得脑正常神... 目的:实现脑磁感应成像系统中的单通道高精度相位差检测功能。材料与方法:基于高精度鉴相器射频锁定放大器SR844建立了相位差检测单元,对磁感应信号进行放大、滤波处理,检测频率为1 MHz;通过培养SD大鼠的大脑皮质神经细胞,获得脑正常神经细胞模型和水肿神经细胞模型;使用不同激励线圈,并在激励线圈与检测线圈之间距离不同时,分别对两种细胞模型产生的相位差进行检测实验。结果:设计的检测单元的技术指标为:检测处理的最小信号为7 mV,放大倍数为3.52 dB~49 dB,相位差分辨率为0.02°,3 dB带宽约为1.5 kHz;细胞实验结果显示SD大鼠脑水肿神经细胞模型产生的相位差小于其正常神经细胞模型产生的相位差。当两线圈相距20 cm,且使用圆形聚焦激励线圈时,检测得两种模型产生的相位差之间的最大差值为0.206°;当两线圈相距10 cm,且使用方形聚焦激励线圈时,检测得两种模型产生的相位差之间的最小差值为0.079°。结论:设计的相位差检测单元满足高精度相位差检测要求,能检测出水肿神经细胞模型与正常神经细胞模型的相位差别。从细胞层面上对脑水肿进行了实验研究,得出了有效的实验结果,为进一步的脑水肿检测打下了良好的基础。 展开更多
关键词 非接触 脑磁感应成像 相位差检测 水肿神经细胞模型 锁定放大器
下载PDF
颅脑血肿MIT涡流场仿真与分析 被引量:2
17
作者 柯丽 赵璐璐 +1 位作者 杜强 林筱 《系统仿真学报》 CAS CSCD 北大核心 2014年第3期517-522,共6页
磁感应断层成像技术(Magnetic Induction Tomography,MIT)通过生物阻抗测量和成像在颅脑疾病的诊断和监护方面具有潜在的优势。基于磁感应断层成像原理正问题的数学模型,利用1026幅颅脑X-CT图像重构了三维人体颅脑结构,并建立了颅脑磁... 磁感应断层成像技术(Magnetic Induction Tomography,MIT)通过生物阻抗测量和成像在颅脑疾病的诊断和监护方面具有潜在的优势。基于磁感应断层成像原理正问题的数学模型,利用1026幅颅脑X-CT图像重构了三维人体颅脑结构,并建立了颅脑磁感应成像仿真模型,利用有限元法进行求解;针对脑血肿病变,研究了脑血肿出血量的体积、电导率以及位置等参数发生变化时感应出的三维涡流磁场,及其变化对边界测量点的影响。仿真的实验结果给出了MIT在颅脑检测时,感应的涡流磁场随血肿变化而发生改变的具体变化规律,并给出比较敏感的检测位置。结果也表明了疾病的变化会引起系统的三维磁场发生改变,反映了MIT能够在颅脑中进行检测,为实际系统的检测以及临床应用打下基础。 展开更多
关键词 磁感应断层 三维颅脑 仿真 脑血肿 涡流磁场
下载PDF
基于LabView和Matlab混合编程的脑MIT数字鉴相方法的实现 被引量:3
18
作者 胡晓彦 秦明新 +3 位作者 梁文文 张华 焦明克 王芸 《第四军医大学学报》 北大核心 2007年第12期1144-1146,共3页
目的:为实现用于脑磁感应成像系统中的数字鉴相方法,寻求一种高精度的相位检测手段.方法:本研究采用LabView对数据采集卡编程,控制激励信号的产生和检测信号的采集;采用Matlab进行快速傅立叶变换法(FFT)法,相关法和经典法的编程,用于实... 目的:为实现用于脑磁感应成像系统中的数字鉴相方法,寻求一种高精度的相位检测手段.方法:本研究采用LabView对数据采集卡编程,控制激励信号的产生和检测信号的采集;采用Matlab进行快速傅立叶变换法(FFT)法,相关法和经典法的编程,用于实现数字鉴相.结果:得到了步进0.1°条件下的数字鉴相结果,构建了一整套包含信号产生、采集和处理的鉴相系统,最终,实现了FFT法和相关法0.1°的相位差分辨率.结论:数字鉴相方法能够应用于脑磁感应断层成像技术(MIT)检测系统中,对高精度的系统测量提供了理论依据. 展开更多
关键词 脑磁感应成像 相位检测 导电性 傅里叶分析 相关法
下载PDF
单通道BMIT系统中相位差的理论计算与实际检测 被引量:2
19
作者 李克 秦明新 +5 位作者 周伟 杨浩 张辉 焦腾 李文哲 焦明克 《中国医学物理学杂志》 CSCD 2009年第2期1097-1101,共5页
目的:研究单通道脑磁感应成像系统中相位差的理论计算与实际检测的相关性,为系统的优化和实验改进提供理论依据。方法:单通道脑磁感应成像系统是基于高精度射频锁定放大器SR844建立的,该系统的工作频率为1MHz,包括一个激励线圈和一个检... 目的:研究单通道脑磁感应成像系统中相位差的理论计算与实际检测的相关性,为系统的优化和实验改进提供理论依据。方法:单通道脑磁感应成像系统是基于高精度射频锁定放大器SR844建立的,该系统的工作频率为1MHz,包括一个激励线圈和一个检测线圈,被测目标置于两线圈之间以检测其相位差;针对该实验系统建立数学模型,推导被测目标靠近检测线圈时相位差计算公式;配制电导率为0S/m~2S/m的琼脂模型进行实验,对理论计算结果进行验证;并以培养的SD大鼠大脑皮质的神经细胞模型为检测对象进行实验。结果:检测结果与理论计算结果的趋势一致,相位差与被测目标的电导率和体积成正比。神经细胞模型引起的相位差为0.421°±0.018°;琼脂糖模型引起的相位差为0.382°±0.013°。结论:该系统能有效地检测出目标相位差,为进一步实现脑磁感应成像打下了良好的基础。 展开更多
关键词 脑磁感应成像 相位差 电导率 神经细胞模型
下载PDF
基于MIT软件鉴相系统设计和相位检测实验 被引量:1
20
作者 张华 荆西京 +2 位作者 路国华 王华 李文哲 《电子科技》 2011年第9期143-145,148,共4页
为解决脑磁感应成像(MIT)系统中相位差检测问题,改进并实现了MIT软件鉴相平台。软件部分采用LabVIEW2009,相位差检测选用FFT鉴相算法;硬件部分选用NI PXI 5122采集卡对数据进行100 MS.s-1的实时采样,选用考虑电磁安全性的增益放大模块... 为解决脑磁感应成像(MIT)系统中相位差检测问题,改进并实现了MIT软件鉴相平台。软件部分采用LabVIEW2009,相位差检测选用FFT鉴相算法;硬件部分选用NI PXI 5122采集卡对数据进行100 MS.s-1的实时采样,选用考虑电磁安全性的增益放大模块实现对微弱小信号的功率放大。构建了一套采样精度高、放大增益可调、基于FFT算法的MIT软件鉴相平台。在模拟脑出血实验中进行相位差检测,随着出血量的增加,相位差相应增大;激励信号功率一定时,随着激励频率增大相位差增大。鉴相精度在原0.01°的基础上提高到0.001°;能够更好地测量和反映MIT系统中组织电导率的变化。 展开更多
关键词 脑磁感应成像 LABVIEW2009 FFT 相位检测
下载PDF
上一页 1 2 6 下一页 到第
使用帮助 返回顶部