The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic f...The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets.展开更多
Magnetic resonance image quality and patient safety have been the focus of engineering and research ever since the invention of equipment in the early 1970s.In high field(or ultrahigh field)MRI systems,the emerging te...Magnetic resonance image quality and patient safety have been the focus of engineering and research ever since the invention of equipment in the early 1970s.In high field(or ultrahigh field)MRI systems,the emerging techniques induced by B1 field challenges have promoted various potential solutions.This paper describes the relationship between RF power and B1þfield performance,and the overall requirements considered in RF subsystem design.The design of the RF in the MR system is systematically summarized,including the entire transmission chain,sequence algorithm and RF pulse design,and the probabilities for improvement and optimization in the system design are indicated.At the same time,the radio frequency related issues of the human whole-body 7 T MR and animal MR systems are discussed,especially the promising future showed by the technologies such as radio frequency parallel transmission technology in the ultrahigh field.展开更多
基金This work is funded by the Magnetic Resonance Union of the Chinese Academy of Sciences(Grant No.2021gzl002)the International Partnership Program of Chinese Academy of Sciences(Grant No.182111KYSB20210014)+1 种基金the National Science Foundation of China(Grant No.52293423,Grant No.52277031)the Research and Development of Key Technologies and Equipment for Major Science and Technology Infrastructure of Development and Reform Commission of Shenzhen Municipality,China(Grant No.ZDKJ20190305002).
文摘The relatively fragile low-temperature stability of cryogen-free superconducting magnetic resonance imaging(MRI)magnets requires the careful management of exogenous heat sources.A strongly shielded gradient magnetic field is important for the optimal operation of cryogen-free MRI systems.In this study,we present an enhanced shielding method incorporating a regionalized stray field constraining strategy.By optimizing the constraint parameters,we could develop engineering-feasible gradient coil schemes without increasing system complexity but with the stray field intensity reduced by half.In real measurement in an integrated MRI system,the developed gradient assembly demonstrated good performance and supported to output images of excellent quality.Our findings suggested that the proposed method could potentially form a useful design paradigm for cryogen-free MRI magnets.
基金The work is supported by Key-Area Research and Development Program of Guangdong Province(grant no.2018B030333001).
文摘Magnetic resonance image quality and patient safety have been the focus of engineering and research ever since the invention of equipment in the early 1970s.In high field(or ultrahigh field)MRI systems,the emerging techniques induced by B1 field challenges have promoted various potential solutions.This paper describes the relationship between RF power and B1þfield performance,and the overall requirements considered in RF subsystem design.The design of the RF in the MR system is systematically summarized,including the entire transmission chain,sequence algorithm and RF pulse design,and the probabilities for improvement and optimization in the system design are indicated.At the same time,the radio frequency related issues of the human whole-body 7 T MR and animal MR systems are discussed,especially the promising future showed by the technologies such as radio frequency parallel transmission technology in the ultrahigh field.