A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, wmcn has a sensluve area of 80 mm×80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce ...A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, wmcn has a sensluve area of 80 mm×80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and without using protection wires. The detector has been tested with a 55Fe X-ray source and a 200 MeV/u ^12C beam from CSRm. A position resdution better than 250 μm along the anode wires and a detection efficiency higher than 90% have been achieved.展开更多
A two dimensional multi-wire proportional chamber with delay line readout was developed, which has a large sensitive area of 30 cmx30 cm. Two cathode planes using printed circuit boards are orthogonally placed to give...A two dimensional multi-wire proportional chamber with delay line readout was developed, which has a large sensitive area of 30 cmx30 cm. Two cathode planes using printed circuit boards are orthogonally placed to give two coordinates of the impact point of the particle. Signals collected from the cathode strips are amplified and discriminated from two ends of the delay line at each cathode board. By recording the time difference between the two discrimination pulses and the common gate pulse from anode wires, a coordinate position was reconstructed, and a position resolution of better than 1 mm could be obtained in the whole sensitive area along the anode wires.展开更多
基金Supported by National Natural Science Foundation of China(11079044)
文摘A normal pressure MWPC for beam diagnostics at RIBLL2 has been developed, wmcn has a sensluve area of 80 mm×80 mm and consists of three-layer wire planes. The anode plane is designed with a wider frame to reduce the discharge and without using protection wires. The detector has been tested with a 55Fe X-ray source and a 200 MeV/u ^12C beam from CSRm. A position resdution better than 250 μm along the anode wires and a detection efficiency higher than 90% have been achieved.
基金Supported by Ministry of Science and Technology of China (2010CB833002)Innovative Program of the Chinese Academy of Sciences (KJCX2-YW-T16)
文摘A two dimensional multi-wire proportional chamber with delay line readout was developed, which has a large sensitive area of 30 cmx30 cm. Two cathode planes using printed circuit boards are orthogonally placed to give two coordinates of the impact point of the particle. Signals collected from the cathode strips are amplified and discriminated from two ends of the delay line at each cathode board. By recording the time difference between the two discrimination pulses and the common gate pulse from anode wires, a coordinate position was reconstructed, and a position resolution of better than 1 mm could be obtained in the whole sensitive area along the anode wires.