Biodegradable magnesium alloy stents(MAS)have great potential in the treatment of cardiovascular diseases.However,too fast degradation and the poor biocompatibility are still two key problems for the clinical utility ...Biodegradable magnesium alloy stents(MAS)have great potential in the treatment of cardiovascular diseases.However,too fast degradation and the poor biocompatibility are still two key problems for the clinical utility of MAS.In the present work,a functional coating composed of hydrophilic polymers and bioactive peptides was constructed on magnesium alloy to improve its corrosion resistance and biocompatibility in vitro and in vivo.Mg-Zn-Y-Nd(ZE21B)alloy modified with the functional coating exhibited moderate surface hydrophilicity and enhanced corrosion resistance.The favourable hemocompatibility of ZE21B alloy with the functional coating was confirmed by the in vitro blood experiments.Moreover,the modified ZE21B alloy could selectively promote the adhesion,proliferation,and migration of endothelial cells(ECs),but suppress these behaviors of smooth muscle cells(SMCs).Furthermore,the modified ZE21B alloy wires could alleviate intimal hyperplasia,enhance corrosion resistance and re-endothelialization in vivo transplantation experiment.These results collectively demonstrated that the functional coating improved the corrosion resistance and biocompatibility of ZE21B alloy.This functional coating provides new insight into the design and development of novel biodegradable stents for biomedical engineering.展开更多
Magnesium alloys are an ideal material for biodegradable vascular stents,which can be completely absorbed in the human body,and have good biosafety and mechanical properties.However,the rapid corrosion rate and excess...Magnesium alloys are an ideal material for biodegradable vascular stents,which can be completely absorbed in the human body,and have good biosafety and mechanical properties.However,the rapid corrosion rate and excessive localized corrosion,as well as challenges in the preparation and processing of microtubes for stents,are restricting the clinical application of magnesium-based vascular stents.In the present work we will give an overview of the recent progresses on biodegradable magnesium based vascular stents including magnesium alloy design,high-precision microtubes processing,stent shape optimisation and functional coating preparation.In particular,the Triune Principle in biodegradable magnesium alloy design is proposed based on our research experience,which requires three key aspects to be considered when designing new biodegradable magnesium alloys for vascular stents application,i.e.biocompatibility and biosafety,mechanical properties,and biodegradation.This review hopes to inspire the future studies on the design and development of biodegradable magnesium alloy-based vascular stents.展开更多
基金project was the National Natural Science Foundation of China(Grant No.52101291)China Postdoctoral Science Foundation(Grant No.2020TQ0273)+1 种基金the National Key Research and Development Program of China(Grant No.2018YFC1106703)the Key Projects of the Joint Fund of the National Natural Science Foundation of China(Grant No.U1804251)。
文摘Biodegradable magnesium alloy stents(MAS)have great potential in the treatment of cardiovascular diseases.However,too fast degradation and the poor biocompatibility are still two key problems for the clinical utility of MAS.In the present work,a functional coating composed of hydrophilic polymers and bioactive peptides was constructed on magnesium alloy to improve its corrosion resistance and biocompatibility in vitro and in vivo.Mg-Zn-Y-Nd(ZE21B)alloy modified with the functional coating exhibited moderate surface hydrophilicity and enhanced corrosion resistance.The favourable hemocompatibility of ZE21B alloy with the functional coating was confirmed by the in vitro blood experiments.Moreover,the modified ZE21B alloy could selectively promote the adhesion,proliferation,and migration of endothelial cells(ECs),but suppress these behaviors of smooth muscle cells(SMCs).Furthermore,the modified ZE21B alloy wires could alleviate intimal hyperplasia,enhance corrosion resistance and re-endothelialization in vivo transplantation experiment.These results collectively demonstrated that the functional coating improved the corrosion resistance and biocompatibility of ZE21B alloy.This functional coating provides new insight into the design and development of novel biodegradable stents for biomedical engineering.
基金supported by the National Natural Science Foundation of China(No.U1804251)the National Key Research and Development Program of China(No.2016YFC1102401)Medical-Engineering Cross Fund of Shanghai Jiao Tong University of China,China(No.YG2019ZDA02).
文摘Magnesium alloys are an ideal material for biodegradable vascular stents,which can be completely absorbed in the human body,and have good biosafety and mechanical properties.However,the rapid corrosion rate and excessive localized corrosion,as well as challenges in the preparation and processing of microtubes for stents,are restricting the clinical application of magnesium-based vascular stents.In the present work we will give an overview of the recent progresses on biodegradable magnesium based vascular stents including magnesium alloy design,high-precision microtubes processing,stent shape optimisation and functional coating preparation.In particular,the Triune Principle in biodegradable magnesium alloy design is proposed based on our research experience,which requires three key aspects to be considered when designing new biodegradable magnesium alloys for vascular stents application,i.e.biocompatibility and biosafety,mechanical properties,and biodegradation.This review hopes to inspire the future studies on the design and development of biodegradable magnesium alloy-based vascular stents.