期刊文献+
共找到51篇文章
< 1 2 3 >
每页显示 20 50 100
Atmospheric particulate pollution of Lanzhou using magnetic measurements 被引量:14
1
作者 Chen Fa\|hu, Yang Li\|ping, Wang Jian\|min, Zhang Jia\|wu Institute of Environment & Hazards, Lanzhou University, Lanzhou 730000, China. E\|mail: fhchen@lzu.edu.cn 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1999年第3期373-377,共5页
To differentiate between natural and anthropogenic particulate sources in the atmosphere in Lanzhou City, samples were collected in different sites. The dust flux was calculated and magnetic measurements were conducte... To differentiate between natural and anthropogenic particulate sources in the atmosphere in Lanzhou City, samples were collected in different sites. The dust flux was calculated and magnetic measurements were conducted. Results show a distinct pattern of variation of dust flux within a year and it agrees with the shifts of atmospheric circulation regime. The magnetic parameters indicate that natural sources are the major components of atmospheric particulate during late spring and early summer, while anthropogenic sources contribute much more during winter months. The data also support the earlier findings that magnetic parameters are effective for differentiating between particulate arising from natural sources such as soil erosion and from anthropogenic sources such as coal combustion. 展开更多
关键词 atmospheric particulate dust flux magnetic measurement Lanzhou of China.
下载PDF
Preliminary Study of the Feasibility of Inverse Problem Algorithms Used for Arc Magnetic Measurement Method
2
作者 汪倩 李兴文 +1 位作者 宋浩永 荣命哲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第2期200-203,共4页
Non-contact magnetic measurement method is an effective way to study the air arc behavior experimentally. One of the crucial techniques is to solve an inverse problem for the electromagnetic field. This study is devot... Non-contact magnetic measurement method is an effective way to study the air arc behavior experimentally. One of the crucial techniques is to solve an inverse problem for the electromagnetic field. This study is devoted to investigating different algorithms for this kind of inverse problem preliminarily, including the preconditioned conjugate gradient method, penalty function method and genetic algorithm. The feasibility of each algorithm is analyzed. It is shown that the preconditioned conjugate gradient method is valid only for few arc segments, the estimation accuracy of the penalty function method is dependent on the initial conditions, and the convergence of genetic algorithm should be studied further for more segments in an arc current. 展开更多
关键词 ARC magnetic measurement electromagnetic field inverse problem
下载PDF
Integrated On-line Instrumentation System of Magnetic Properties Measurement
3
作者 D.G.Park, Y.Y.Song. H.Song and J.H.Hong (Korea Atomic Energy Research Institute, Yusong P.O.Box 105, Taejon, 305-600 Korea) C.G.Kim (Department of Physics, Sun Moon Univ., Asan-si, Chungnam, 336840 Korea) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第2期248-249,共2页
A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field duri... A portable microcomputer-controlled inspection system has been developed for detection of magnetic properties of soft magnetic materials. It incorporates custom designed software for control of the magnetic field during operation such as demagnetization, field sweeping, and for data logging and analysis. Results are recorded using a 12-bit analog to digital converter and are then stored on disk. The magnetic hysteresis loop and Barkhausen noise data can be converted into important magnetic parameters: coecivity, remanence, and hysteresis loss, Barkhausen amplitude, and Barkhausen noise energy. This system incorporated with the magnetostriction, and magnetoacoustic emission, is then related with the nondestructive detection of material degradation. 展开更多
关键词 line Integrated On-line Instrumentation System of magnetic Properties measurement
下载PDF
EXPERIMENTAL MEASUREMENT OF MAGNETIC FIELD IN A NOVEL FLOW CONTROL OF MOLD
4
作者 G.J. Xu, D.H. Li and J.C. HeThe Key Laboratory of National Education Ministry for Electromagnetic Processing of Materials, Northeastern University, Shenyang 110006, China Manuscript received 10 September 2001 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2002年第3期260-266,共7页
In order to know the distribution of magnetic field in a novel flow control of mold (NFC Mold) and to provide the experimental data for the electromagnetic structure design and the analysis of flow control in continuo... In order to know the distribution of magnetic field in a novel flow control of mold (NFC Mold) and to provide the experimental data for the electromagnetic structure design and the analysis of flow control in continuous casting mold, the magnetic field in a NFC Mold were measured by Tesla meter of Model CT-3. The method of vector synthesis was adopted in the measurement of magnetic fields. The results showed that the magnetic field in the NFC Mold was composed of two main magnetic areas that were symmetrical. Although there was leaking magnetic flux between the lower surface of the upper pole and the upper surface of the lower pole on the sides, it was restrained by the main magnetic fields effectively. Therefore the NFC Mold was more preferably satisfied to be used in controlling the molten steel flow in continuous casting mold. 展开更多
关键词 continuous casting mold measurement of magnetic field method of vector synthesis
下载PDF
Magnetic Field Measurement with Heisenberg Limit Based on Solid Spin NOON State
5
作者 周雷鸣 董杨 孙方稳 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第6期164-168,共5页
The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid ... The maximum entangled number state (NOON state) can improve the sensitivity of physical quantity measure- ment to the Heisenberg limit 1/N. In this work, the magnetic field measurement based on the individual solid spin NOON state is investigated. Based on the tunable effective coupling coefficient, we propose a generation scheme of the three-spin NOON state, i.e, the Creenberger-Horne-Zeilinger (CHZ) state, and discussed the mea- surement resolution reduction due to decoherence. It is unnecessary to entangle spins as many as possible when decoherence exists. In practice, defect spins in diamond and alp donors with long coherence time can be applied with current techniques in the nano-scaled high resolution magnetic measurement. 展开更多
关键词 magnetic Field measurement with Heisenberg Limit Based on Solid Spin NOON State
下载PDF
Enhancing magnetic properties of anisotropic NdDyFeCoNbCuB powder by applying magnetic field at high temperature during hydrogen desorption 被引量:1
6
作者 LUO Jianjun P. De Rango +4 位作者 D. Fruchart MEI Jinna HU Rui LI Jinshan ZHOU Lian 《Rare Metals》 SCIE EI CAS CSCD 2010年第5期480-485,共6页
Anisotropic powder was prepared with precursor (NdDy)-(FeCoNbCu)-B sintered magnets by hydrogen decrepitation, desorption, and subsequent annealing treatment. The hydrogen desorption was performed in magnetic fiel... Anisotropic powder was prepared with precursor (NdDy)-(FeCoNbCu)-B sintered magnets by hydrogen decrepitation, desorption, and subsequent annealing treatment. The hydrogen desorption was performed in magnetic fields of 0, 1, 3, and 5 T. The orientation of tetragonal phase grains of the powder was evaluated from the hysteresis loops measured by extraction magnetometer. Residual hydrogen content of the powder was evaluated by thermal-magnetic analysis. The powder with Hcj, Br, and (BH)max of 1138 kA.m^-1, 1.029 T, and 172.5 kJ.m^-3, respectively, was achieved under the condition of the magnetic field of 3 T. Magnetic properties of the powder, especially, the remanence of the powder, are enhanced upon magnetic fields, which is due to better orientation of powder particles and less residual hydrogen in the powder resulted from the magnetic field during the hydrogen desorption process. 展开更多
关键词 permanent magnets hydrogen absorbing materials ANISOTROPY magnetic measurements magnetic properties
下载PDF
Response optimization of a three-axis sensitive SERF magnetometer for closed-loop operation
7
作者 周原锐 孙永泽 +3 位作者 汪茜茜 秦佳男 张雪 王言章 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期291-297,共7页
Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of the... Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of these methods is greatly limited because the frequency of the modulation signal should be slow enough to ensure the validity of the quasi-steady-state solution.In this work,a new model to describe the response of the three-axis sensitive SERF AM with high modulation frequency is presented and verified.The response of alkali-atomic spin to high-frequency modulation field is further investigated by solving the Bloch equation in a modulation-frequency-dependence manner.This solution is well verified by our experiments and can offer a reference for selection of modulation frequencies.The result shows a potential to achieve a SERF AM operating in a geomagnetic field without heavy aluminum shielding when the modulation frequencies are selected properly. 展开更多
关键词 triaxial-vectorial magnetic field measurement spin-exchange relaxation free atomic magnetometer
下载PDF
Anomalous magnetic properties of an iron film system deposited on fracture surfaces of α-Al_2O_3 ceramics
8
作者 焦志伟 陈苗根 +2 位作者 姜伟棣 冯春木 叶高翔 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第9期3499-3504,共6页
An iron film percolation system is fabricated by vapour-phase deposition on fracture surfaces of α-Al2O3 ceramics. The zero-field-cooled (ZFC) and field-cooled (FC) magnetization measurement reveals that the magn... An iron film percolation system is fabricated by vapour-phase deposition on fracture surfaces of α-Al2O3 ceramics. The zero-field-cooled (ZFC) and field-cooled (FC) magnetization measurement reveals that the magnetic phase of the film samples evolve from a high-temperature ferromagnetic state to a low-temperature spin-glass-like state, which is also demonstrated by the temperature-dependent ac susceptibility of the iron films. The temperature dependence of the exchange bias field He of the iron film exhibits a minimum peak around the temperature T=5 K, which is independent of the magnitude of the cooling field Hcf. However, for T 〉 10K, (1) He is always negative when Hcf=2kOe and (2) for Hcf= 20 kOe (1Oe≈80 A/m), He changes from negative to positive values as T increases. Our experimental results show that the anomalous hysteresis properties mainly result from the oxide surfaces of the films with spin-glass-like phase. 展开更多
关键词 iron film CERAMICS exchange interactions magnetic measurements
下载PDF
Upgrade of the magnetic diagnostic system for restart of HT-6M operation
9
作者 陈力行 沈飊 +5 位作者 陈大龙 罗正平 张祖超 陈颖 王勇 钱金平 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第12期347-355,共9页
The HT-6M tokamak at the Thailand Institute of Nuclear Technology has been restarted.In order to ensure the smooth breakdown of plasma and obtain plasma discharge parameters,optimization of the poloidal field coils an... The HT-6M tokamak at the Thailand Institute of Nuclear Technology has been restarted.In order to ensure the smooth breakdown of plasma and obtain plasma discharge parameters,optimization of the poloidal field coils and upgrade of the magnetic diagnostics are described in this article.A perfect null field(stray field in the main chamber<10 G)is obtained using an ohmic heating field.To obtain important information about the plasma,an external magnetic diagnostics system is designed and calibrated,including a Rogowski coil(measuring plasma current),a magnetic probe(measuring external field),diamagnetic loops(measuringβ_(p))and so on.In order to realize high-frequency signal measurement and transmission,a series of frequency responses with the magnetic probe and transmission line are tested.Later,to verify the null field,a fitting code is developed to reconstruct the stray field in the vacuum chamber based on magnetic probe measurements and flux loops.The results show that the error is within 1.5%.This indicates the accuracy of the magnetic measurement system and ensures the preparation for the breakdown of plasma. 展开更多
关键词 HT-6M null field magnetic measurement high frequency calibration
下载PDF
STRUCTURAL TRANSFORMATION INDUCED BY MECHANICALLY DRIVEN ALLOYING AND SUBSEQUENT MAGNETIC PROPERLIESOF THE Fe-Cu SYSTEM
10
作者 Y.Z.Yang Y.HLuo +4 位作者 Q.S.Li Y.L.Zhu X.M.Ma Y.D.Dong Y.Z.Chuang 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1998年第2期128-136,共9页
The structural transformation in Fe-Cu powder induced by mechanically driven alloying has been monitored by the lattice constant measurements and Mossbauer spectroscopy. For the samples with Cu higher than 75at.% Moss... The structural transformation in Fe-Cu powder induced by mechanically driven alloying has been monitored by the lattice constant measurements and Mossbauer spectroscopy. For the samples with Cu higher than 75at.% Mossbauer the spectra show a broad paramagnetic doublet; for samples with 50 and 60at.%Cu a new broad ferromagnetic sextet; for those with less than 30at.%Cu similar to those of α-Fe. The main peaks of the hyperfine field distribution significantly broaden and shift to a lower position with increasing Cu content due to the complex environments of iron atoms in the solid solutions and the reduction in the nearest neighbor Fe of a cental Fe atom, respectively. The saturation magnetization of Fe-Cu alloys monotonously decreases with Cu content. The complex composition dependence of coercive field for the milled samples is discussed with respect to the solid dissolution, grain size, interfacial state etc.. The increase of lattice constants with the solute content in the two terminal solid solutions has been explained by the volume-size factor theory or magnetovolume effect. 展开更多
关键词 mechanical alloying Mossbauer effect Fe-Cu alloy magnetic measurement
下载PDF
Elaboration and Magnetic Properties of Cobalt-Palladium Magnetic Nanowires Encapsulated in Carbon Nanotubes
11
作者 Olivier Rousseau Cynthia Locard +3 位作者 Aichata Kane Yves Roussigne Samir Farhat Salim Mourad Cherif 《Journal of Surface Engineered Materials and Advanced Technology》 2017年第1期1-12,共12页
Bimetallic one-dimensional (1-D) cobalt-palladium magnetic nanowires encapsuled by carbon nanotubes were synthesized on silicon substrate using plasma enhanced chemical vapor deposition technique. After the deposition... Bimetallic one-dimensional (1-D) cobalt-palladium magnetic nanowires encapsuled by carbon nanotubes were synthesized on silicon substrate using plasma enhanced chemical vapor deposition technique. After the deposition of the catalyst, the growth of nanotubes takes place in two stages. The first is a thermal pretreatment to transform continuous nanometer bimetallic thick film into isolated and uniformly distributed nanoparticles over the entire surface of the substrate. The second step results in the growth of nanotubes perpendicular to the substrate by the addition of carbon atoms on the insulated metal nanoparticles. While growing the nanotubes at given thermochemical conditions, a Co-Pd eutectic is thought to diffuse inside the cavity of the nanotube along a length of few hundreds of nanometers as determined by high resolution, spatially resolved Electron Energy Loss Spectroscopy (EELS), and energy filtered elemental mapping. The magnetic anisotropy along the nanotube directions is observed. Ferromagnetic or superparamagnetic-like behavior of the filled nanotubes was measured through local magneto-optical Kerr effect or global superconducting quantum interference device measurements, respectively. Information on the magnetism of filled nanotubes at different scales is pointed out and discussed. 展开更多
关键词 magnetic Nanowire Filled Carbon Nanotubes COBALT PECVD Static magnetic measurements
下载PDF
Hydrothermal Reaction, Structure and Magnetic Properties of a Binuclear Cobalt Complex with N-donor Ligand:2-Methyldipyrido[3,2-f:2ˊ3ˊ-h]quinoxaline 被引量:2
12
作者 黄艳菊 闫永胜 张红妍 《Chinese Journal of Structural Chemistry》 SCIE CAS CSCD 2014年第11期1580-1586,共7页
One complex [Co1.5(C6H5CHCHCOO)3(Medpq)]·H2O(C6H5CHCHCOO = cinnamic acid, Medpq = 2-methyldipyrido[3,2-f:2,3-h]quinoxaline) 1 has been hydrothermally synthesized and structurally characterized by elemental... One complex [Co1.5(C6H5CHCHCOO)3(Medpq)]·H2O(C6H5CHCHCOO = cinnamic acid, Medpq = 2-methyldipyrido[3,2-f:2,3-h]quinoxaline) 1 has been hydrothermally synthesized and structurally characterized by elemental analysis, IR spectrum, TG, single-crystal X-ray diffraction and magnetic susceptibility measurements. Complex 1 crystallizes in the triclinic system, space group P1, with a = 10.224(5), b = 14.572(5), c = 15.139(5)A, α = 112.704(5), β = 97.168(5), γ = 109.749(5), V = 1871.8(13) 3 and Z = 2(at 293(2) K). In the crystal structure, the Co(1) ion is hexa-coordinated with six atoms from three different cinnamic acid ligands and the symmetric three different cinnamic acid ligands; the Co(2) center adopts a coordination environment with two nitrogen atoms from Medpq ligand and four oxygen atoms from two different cinnamic ligands, assuming a slightly distorted octahedral geometry, respectively. The negative value of the Weiss constant indicates antiferromagnetic exchange interactions between the Co ions. 展开更多
关键词 cobalt complex magnetic susceptibility measurement 2-methyldipyrido[3 2-f:2ˊ 3ˊ-h]quinoxaline
下载PDF
Superconducting multipole wiggler with large magnetic gap for HEPS-TF
13
作者 Xian-Jing Sun Fu-San Chen +22 位作者 Xiang-Chen Yang Wan Chen Xiao-Juan Bian Min-Xian Li Rui Ge Miao-Fu Xu Yao Gao Jin-Can Wang Hui-Hua Lu Jian-She Cao Zhi-Qiang Li Zhuo Zhang Rui Ye Xiang-Zhen Zhang Shuai Li Bao-Gui Yin Mei Yang Ling-Ling Gong Da-Heng Ji Lin Bian Ran Liang Ya-Jun Sun Hong Shi 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第2期21-29,共9页
A 16-pole superconducting multipole wiggler with a large gap of 68 mm was designed and fabricated to serve as a multipole wiggler for HEPS-TF.The wiggler consists of 16 pairs of NbTi superconducting coils with a perio... A 16-pole superconducting multipole wiggler with a large gap of 68 mm was designed and fabricated to serve as a multipole wiggler for HEPS-TF.The wiggler consists of 16 pairs of NbTi superconducting coils with a period length of 170 mm,and its maximum peak field is 2.6 Tesla.In magnet design,magnet poles were optimized.Furthermore,the Lorentz force on the coils and electromagnetic force between the upper and lower halves were computed and analyzed along with the stored energy and inductance at different currents.To enhance the critical current of the magnet coil,all the pole coils selected for the magnet exhibited excellent performance,and appropriate prestress derived from the coil force analysis was applied to the pole coils during magnet assembly.The entire magnet structure was immersed in 4.2-K liquid helium in the cryostat cooled solely by four two-stage cryocoolers,and the performance test of the superconducting wiggler was appropriately completed.Based on the measured results,the first and second field integrals on the axis of the superconducting wiggler were significantly improved at different field levels after the compensation of the corrector coils.Subsequently,the wiggler was successfully installed in the storage ring of BEPCII operation with beams. 展开更多
关键词 Superconducting multipole wiggler Force analysis Quench protection magnetic field measurement HEPS-TF Cryostat
下载PDF
Mechanical Analysis and Measurements of a Multicomponent NbTi/Cu Superconducting Magnets Structure for the Fully Superconducting Electron Cyclotron Resonance Ion Source 被引量:1
14
作者 关明智 胡强 +6 位作者 高配峰 王省哲 杨通军 吴巍 辛灿杰 吴北民 马力祯 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第5期135-139,共5页
A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconductin... A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further 展开更多
关键词 of on IS as NBTI Mechanical Analysis and measurements of a Multicomponent NbTi/Cu Superconducting Magnets Structure for the Fully Superconducting Electron Cyclotron Resonance Ion Source in for Cu
下载PDF
MAGNETIC PHASE DIAGRAM OF SmMn_2(Ge_(1-x)Si_x)_2 SYSTEM
15
作者 Y.G. Wang F.M Yang +1 位作者 C.P. Chen, N Tang and Q.D. Wang (State Key Laboratory of Magnetism, Institute of Physics, Chinese Academy of Sciences, P.O. Box 603,Beijing 100080, China)(Department of Materials Science and Engineering, Zheiang University Hangzhou 3 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1997年第1期61-64,共4页
The magnetic phase diagram (x,T) of the SmMn2(Ge1-xSix)2 system has been studied by susceptibility and magnetization measurement. With increasing silicon concentration the temperature region of ferromagnetic ordering ... The magnetic phase diagram (x,T) of the SmMn2(Ge1-xSix)2 system has been studied by susceptibility and magnetization measurement. With increasing silicon concentration the temperature region of ferromagnetic ordering decreases on the phaae diagram. 展开更多
关键词 magnetic phase diagram susceptibility and magnetization measurement X-ray diffraction SmMn_2(Ge_(1-x)Si_x)_2 system
下载PDF
High-Sensitivity Magnetization Measurements
16
作者 C.D. Graham (Dept. of Materials Science, University of Pennsylvania, Philadelphia, PA 19104, USA) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第2期97-101,共5页
The three most common instruments for high-sensitivity magnetization measurements (the vibrating-sampie magnetometer, the alternating gradient magnetometer, and the SQUID magnetometer) are described and their limiting... The three most common instruments for high-sensitivity magnetization measurements (the vibrating-sampie magnetometer, the alternating gradient magnetometer, and the SQUID magnetometer) are described and their limiting sensitivities are discussed. The advantages and disadvantages of each are described. Magnetometers using micro-machined force detectors are briefly mentioned. 展开更多
关键词 VSM High-Sensitivity Magnetization measurements
下载PDF
Magnetic Islands Observed by a Fast-Framing Tangentially Viewing Soft X-Ray Camera on LHD and TEXTOR
17
作者 S. OHDACHI K. TOI +1 位作者 G. FUCHS TEXTOR Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第1期45-49,共5页
The formation of magnetic islands within plasmas confined magnetically within the tori has significant influence upon their confinement and stability. To obtain an experimental insight into the formation and dynamics ... The formation of magnetic islands within plasmas confined magnetically within the tori has significant influence upon their confinement and stability. To obtain an experimental insight into the formation and dynamics of such island structures we employed a fast framing camera viewing the plasma tangentially in the toroidal direction. The toroidal viewing direction gives the advantage in that the islands are viewed almost tangentially and this greatly facilitates the reconstruction of the local data from the line integrated ones. We discuss an effective method to do inversion. To study the fluctuations seen in the video images we perform a singular value decomposition, and then we use a truncated least square method to infer their pictures in space. 展开更多
关键词 magnetic island fluctuation measurement tomography
下载PDF
The Magnetic Anisotropy and Complete Phase Diagram of CuFeO2 Measured in a Pulsed High Magnetic Field up to 75 T
18
作者 左华坤 时丽然 +6 位作者 夏正才 黄俊伟 陈柏蓉 金昭 魏蒙 欧阳钟文 成刚 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第4期130-133,共4页
The magnetization behavior of a CuFeO2 single crystal grown by the floating zone technique is investigated with a pulsed high magnetic field. We observe a series of field-induced multi-step-like transitions with hyste... The magnetization behavior of a CuFeO2 single crystal grown by the floating zone technique is investigated with a pulsed high magnetic field. We observe a series of field-induced multi-step-like transitions with hysteresis, of which the critical magnetic fields are temperature-dependent and show anisotropy. By using a pulsed high magnetic field up to 75 T, the magnetization behavior shows that the critical transition magnetic fields of spin- flip/flop shift to lower field regions with an increase in temperature. According to the magnetization curves, a complete magnetic phase diagram is depicted. 展开更多
关键词 The magnetic Anisotropy and Complete Phase Diagram of CuFeO2 Measured in a Pulsed High magnetic Field up to 75 T AFM
下载PDF
Techniques and Apparatus for Measuring Rotational Core Losses of Soft Magnetic Materials
19
作者 Jin-Jiang Zhong You-Guang Guo +2 位作者 Jian-Guo Zhu Hai-Yan Lu Jian-Xun Jin 《Journal of Electronic Science and Technology of China》 2007年第3期218-225,共8页
In many situations such as the cores of a rotating electrical machine and the T joints of a multiphase transformer, the local flux density varies with time in terms of both magnitude and direction, i.e. the flux densi... In many situations such as the cores of a rotating electrical machine and the T joints of a multiphase transformer, the local flux density varies with time in terms of both magnitude and direction, i.e. the flux density vector is rotating. Therefore, the magnetic properties of the core materials under the rotating flux density vector excitation should be properly measured, modeled and applied in the design and analysis of these electromagnetic devices. This paper presents an extensive review on the development of techniques and apparatus for measuring the rotational core losses of soft magnetic materials based on the experiences of various researchers in the last hundred years. 展开更多
关键词 magnetic property measurement measuring apparatus measuring technique rotational core loss soft magnetic material.
下载PDF
Study of Electromagnetic Compatibility in Hospital Environments
20
作者 Oscar Gutierrez Miguel Angel Navarro +3 位作者 Francisco Saez de Adana Adolfo Escobar Maria E.Moncada Claudio Marcelo Munoz 《Journal of Electromagnetic Analysis and Applications》 2014年第7期141-155,共15页
This paper presents a study on the effects of radiation from electronic equipment in hospitals. This study was performed in Argentinean, Colombian and Spanish hospitals. The work consists of two parts: a survey to det... This paper presents a study on the effects of radiation from electronic equipment in hospitals. This study was performed in Argentinean, Colombian and Spanish hospitals. The work consists of two parts: a survey to determine the hospital personnel’s knowledge of the problem and a technical part consisting of a measurements campaign to determine the levels of radiated electrical and magnetic fields in several hospitals due to the presence of electromagnetic interferences, such as the use of mobile phones. The study of this problem has been of special interest in countries such as the USA and Canada, and this paper attempts to convey the necessity of creating regulations that can be applied to the hospitals of the countries analyzed. More than fifty hospitals were studied in these three countries, considering the following aspects: the hospital personnel’s awareness of the problem, whether the hospitals have performed previous studies of this type, the appearance of problems in medical equipment due to this interference, the origin of the interference, and the failures that have appeared in computers due to electromagnetic interference. The results show that, most hospitals have a lack of knowledge regarding this issue and that field levels above those allowed by international regulations are present. Therefore, a regulation must be established to avoid the problem. 展开更多
关键词 Electromagnetic Compatibility Radiated Emissions magnetic Field measurements Electric Field measurements
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部