The control of the stability of the filament tension is one of the crucial techniques ensuring the component quality of the composite materials. The open-loop tension control system, with industrial control computer a...The control of the stability of the filament tension is one of the crucial techniques ensuring the component quality of the composite materials. The open-loop tension control system, with industrial control computer as the core, magnetic particle clutch as the actuator, equipped with compensation technique is researched and manufactured. It can assure the tension control stability of the yarn in filament winding process and increase the control precision of the whole system.展开更多
Purpose: Magnetic hyperthermia treatment (MHT) is a strategy for cancer therapy using the tem-perature rise of magnetic nanoparticles (MNPs) under an alternating magnetic field (AMF). Re-cently, a new imaging method c...Purpose: Magnetic hyperthermia treatment (MHT) is a strategy for cancer therapy using the tem-perature rise of magnetic nanoparticles (MNPs) under an alternating magnetic field (AMF). Re-cently, a new imaging method called magnetic particle imaging (MPI) has been introduced. MPI allows imaging of the spatial distribution of MNPs. The purpose of this study was to investigate the feasibility of visualizing and quantifying the intratumoral distribution and temporal change of MNPs and predicting the therapeutic effect of MHT using MPI. Materials and Methods: Colon-26 cells (1 × 106 cells) were implanted into the backs of eight-week-old male BALB/c mice. When the tumor volume reached approximately 100 mm3, mice were divided into untreated (n = 10) and treated groups (n = 27). The tumors in the treated group were directly injected with MNPs (Resovist?) with iron concentrations of 500 mM (A, n = 9), 400 mM (B, n = 8), and 250 mM (C, n = 10), respectively, and MHT was performed using an AMF with a frequency of 600 kHz and a peak amplitude of 3.5 kA/m. The mice in the treated group were scanned using our MPI scanner immediately before, immediately after, 7 days, and 14 days after MHT. We drew a region of interest (ROI) on the tumor in the MPI image and calculated the average, maximum, and total MPI values and the number of pixels by taking the threshold value for extracting the contour as 40% of the maximum MPI value (pixel value) within the ROI. These parameters in the untreated group were taken as zero. We also measured the relative tumor volume growth (RTVG) defined by (V-V0)/V0, where V0 and V are the tumor volumes immediately before and after MHT, respectively. Results: The average, maximum, and total MPI values decreased up to 7 days after MHT and remained almost constant thereafter in all groups, whereas the number of pixels tended to increase with time. The RTVG values in Groups A and B were significantly lower than those in the control group 3 days or more and 5 days or more after MHT, respectively. The above four parameters were significantly inversely correlated with the RTVG values 5, 7, and 14 days after MHT. Conclusion: MPI can visualize and quantify the intratumoral distribution and temporal change of MNPs before and after MHT. Our results suggest that MPI will be useful for predicting the therapeutic effect of MHT and for the treatment planning of MHT.展开更多
Purpose: Magnetic targeting refers to the attachment of therapeutic agents to magnetizable particles such as magnetic nanoparticles (MNPs) and then applying magnetic fields to concentrate them to the targeted region s...Purpose: Magnetic targeting refers to the attachment of therapeutic agents to magnetizable particles such as magnetic nanoparticles (MNPs) and then applying magnetic fields to concentrate them to the targeted region such as solid tumors. The purpose of this study was to investigate the usefulness of magnetic particle imaging (MPI) for monitoring the effect of magnetic targeting using tumor-bearing mice. Materials and Methods: Colon-26 cells (1 × 106 cells) were implanted into the backs of eight-week-old male BALB/c mice. When the tumor volume reached approximately 100 mm3, the mice were divided into treated (n = 8) and untreated groups (n = 8). The tumors in the treated group were directly injected with MNPs (Resovist?, 250 mM) and a neodymium magnet was attached to the tumor surface, whereas the magnet was not attached to the tumor in the untreated group. The mice were imaged using our MPI scanner and the average and maximum MPI values were obtained by drawing a region of interest (ROI) on the tumor, with the threshold value for extracting the contour of the tumor being taken as 40% of the maximum MPI value in the ROI. The relative tumor volume growth (RTVG) was calculated from (V ? V0)/V0, where V0 and V represented the tumor volume immediately before and after the injection of MNPs, respectively. Results: The average and maximum MPI values in the treated group were significantly higher than those in the untreated group 3 days after the injection of MNPs, suggesting the effectiveness of magnetic targeting. There were no significant differences in RTVG between the two groups. Conclusion: Our preliminary results suggest that MPI is useful for monitoring the effect of magnetic targeting.展开更多
Fe_3O_4/Polystyrene(PSt) magnetic particles with core/shell structure have been prepared in thepresence of Fe_3O_4 magnetic fluid in ethanol/water medium by dispersion polymeriation of styrene. A Fe_3O_4particle forma...Fe_3O_4/Polystyrene(PSt) magnetic particles with core/shell structure have been prepared in thepresence of Fe_3O_4 magnetic fluid in ethanol/water medium by dispersion polymeriation of styrene. A Fe_3O_4particle formation mechanism was proposed. According to this mechanism, the size of particle nuclei isdetermined by the extent of aggregation of Fe_3O_4 /oligomer. Magnetic particles with diameter ranging from 5to 200 μm were prepared under different reaction conditions. Some polymerization parameters such as theconcentration of monomer, stabilizer, initiator, and ethanol which affect particle size and size distribution arediscussed and their effect on particle formation are explained by the proposed mechanism.展开更多
The influence of the magnetization of a soft magnetic sphere on the surrounding magnetic field is measured and characterized.The interaction force between two soft magnetic particles is directly measured using an ultr...The influence of the magnetization of a soft magnetic sphere on the surrounding magnetic field is measured and characterized.The interaction force between two soft magnetic particles is directly measured using an ultra precision load sensor in uniform and non-uniform magnetic fields. The interaction force largely follows an inverse fourth power law as a function of separation distance between particle centers. At small distances,the effect of magnetization of one particle on the magnetization of its adjacent particle causes the attractive(repulsive) force to be larger(smaller) than that predicted by the inverse fourth power law.The theoretical prediction based on a modified dipole model,that takes into account the coupling effect of the magnetization among soft magnetic particles,gives excellent agreement with the measured force in a uniform magnetic field.The interaction force under a non-uniform applied magnetic field can be reasonably predicted using the dipole-dipole interaction model when the local magnetic field is used to determine the magnetization.展开更多
Zero-temperature Monte Carlo simulations are used to investigate the hysteresis of a magnetic particle ina dipolarIsing model. The magnetic particle is described in a system of permanent dipoles, and the dipoles are l...Zero-temperature Monte Carlo simulations are used to investigate the hysteresis of a magnetic particle ina dipolarIsing model. The magnetic particle is described in a system of permanent dipoles, and the dipoles are locatedin a cubic lattice site. The effects of the shape and the size of the particle on the hysteresis loop at zero temperatureare obtained. For strong exchange interactions, the shapes of magnetic hysteresis loops approach rectangle. For weakexchange interactions, the effects of the size and the shape of the particle on the loops are more remarkable than thoseof strong exchange interactions case. The slope of the hysteresis loop decreases with the increase of the ratio of thesemi major axis to the semi minor axis of the ellipsoidal magnetic particle, and there is an increase of the slope of thehysteresis with the decrease of the size of the magnetic particle. The effects of the shape and size of the particle on thecoercive force at zero temperature are also investigated.展开更多
Magnetic particle imaging(MPI)is an emerging molecular imaging technique with high sensitivity and temporal-spatial resolution.Image reconstruction is an important research topic in MPI,which converts an induced volta...Magnetic particle imaging(MPI)is an emerging molecular imaging technique with high sensitivity and temporal-spatial resolution.Image reconstruction is an important research topic in MPI,which converts an induced voltage signal into the image of superparamagnetic iron oxide particles concentration distribution.MPI reconstruction primarily involves system matrix-and x-space-based methods.In this review,we provide a detailed overview of the research status and future research trends of these two methods.In addition,we review the application of deep learning methods in MPI reconstruction and the current open sources of MPI.Finally,research opinions on MPI reconstruction are presented.We hope this review promotes the use of MPI in clinical applications.展开更多
Purpose:This work focused on the investigation the hyperthermia performance of the carboncoated magnetic particles(CCMPs)in laser-induced hyperthermia.Materials and methods:We prepared CCMPs using the organic carboniz...Purpose:This work focused on the investigation the hyperthermia performance of the carboncoated magnetic particles(CCMPs)in laser-induced hyperthermia.Materials and methods:We prepared CCMPs using the organic carbonization method,and then characterized them with transmission electron microscopy(TEM),ultraviolet-visible(UV-Vis)spectrophotometry,vibrating sample magnetometer(VSM)and X-ray di®raction(XRD).In order to evaluate their performance in hyperthermia,the CCMPs were tested in laser-induced thermal therapy(LITT)experiments,in which we employed a fully distributedfiber Bragg grating(FBG)sensor to profile the tissue's dynamic temperature change under laser irradiation in real time.Results:The sizes of prepared CCMPs were about several micrometers,and the LITT results show that the tissue injected with the CCMPs absorbed more laser energy,and its temperature increased faster than the contrast tissue without CCMPs.Conclusions:The CCMPs may be of great help in hyperthermia applications.展开更多
Fe_3O_4/PS magnetic particles with core/shell structure has been prepared in the presence of Fe3O4 magnetic fluid in ethanol/water mixture.Magnetic particles with diameter size range from 5. 54 t0 187. 32 μm were obt...Fe_3O_4/PS magnetic particles with core/shell structure has been prepared in the presence of Fe3O4 magnetic fluid in ethanol/water mixture.Magnetic particles with diameter size range from 5. 54 t0 187. 32 μm were obtained by different reaction conditions.Some parameters such as ethanol, PEG and monomer which affect particle size diameter and size distribution are discussed briefly in this paper.展开更多
The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological pro...The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological process design. The selective separation of the magnetizable particles is performed for example by a high-gradient magnetic separator. In this study FEM and CFD simulations of the magnetic field and the fluid flow field within a filter chamber of a magnetic separator were carried out, to find an optimal separator design. The motion of virtual magnetizable particles was calculated with a one-way coupled Lagrangian approach in order to test many geometric and parametric variations in reduced time. It was found that a flow homogenisator smoothed the fluid flow, so that the linear velocity became nearly equal over the cross section in the direction of flow. Furthermore the retention of magnetizable particles increases with a high total edge length within the filter matrix.展开更多
The magnetization reversal process and hysteresis loops in a single crystal α-iron with nonmagnetic particles are simulated in this work based on the Landau-Lifshitz-Gilbert equation. The evolutions of the magnetic d...The magnetization reversal process and hysteresis loops in a single crystal α-iron with nonmagnetic particles are simulated in this work based on the Landau-Lifshitz-Gilbert equation. The evolutions of the magnetic domain morphology are studied, and our analyses show that the magnetization reversal process is affected by the interaction between the moving domain wall and the existing nonmagnetic particles. This interaction strongly depends on the size of the particles, and it is found that particles with a particular size contribute the most to magnetic hardening.展开更多
Objective:To explore the application value of magnetic particle chemiluminescence method in the detection of hepatitis C virus(HCV)IgM,IgG and other antibody indicators in mice.Methods:A total of 90 mice with HCV were...Objective:To explore the application value of magnetic particle chemiluminescence method in the detection of hepatitis C virus(HCV)IgM,IgG and other antibody indicators in mice.Methods:A total of 90 mice with HCV were selected as the research objects.All the mice were tested for HCV IgM and IgA antibody,and then their venous blood samples were taken to detect the antibody index by enzyme-linked immunosorbent assay,magnetic particle chemiluminescence method and indirect agglutination method,and the results and positive rates of the three groups were compared.Results:There was no significant difference in the positive rate among the three groups(P>0.05).The specificity,accuracy and sensitivity of indirect agglutination test for IgM were 90.79%,80.00%and 30.00%,respectively.The specificity,accuracy and sensitivity of magnetic particle chemiluminescence assay were 97.44%,93.33%and80.00%,respectively.The specificity,accuracy and sensitivity of indirect agglutination assay were significantly lower than those of magnetic particle chemiluminescence assay(P<0.05).For IgA,the specificity,accuracy and sensitivity of indirect agglutination assay were 90.67%,78.66%and 20.00%,respectively.The specificity,accuracy and sensitivity of magnetic particle chemiluminescence assay were 96.25%,92.35%and80.00%,respectively.The specificity,accuracy and sensitivity of indirect agglutination assay were lower than those of magnetic particle chemiluminescence assay,and the difference was statistically significant(P<0.05).Conclusion:The magnetic particle chemiluminescence method is more effective in the detection of IgM,IgG and other antibodies in mice with HCV.展开更多
Fe3O4 magnetic nanoparticles were prepared by the aqueous co-precipitation of FeCl3-6H2O and FeCl2-4H2O with addition of ammonium hydroxide. The conditions for the preparation of Fe3O4 magnetic nanoparticles were opti...Fe3O4 magnetic nanoparticles were prepared by the aqueous co-precipitation of FeCl3-6H2O and FeCl2-4H2O with addition of ammonium hydroxide. The conditions for the preparation of Fe3O4 magnetic nanoparticles were optimized, and Fe3O4 magnetic nanoparticles obtained were characterized systematically by means of transmission electron microscope (TEM), dynamic laser scattering analyzer (DLS) and X-ray diffraction (XRD). The results revealed that the magnetic nanoparticles were cubic shaped and dispersive, with narrow size distribution and average diameter of 11.4 nm. It was found that the homogeneous variation of pH value in the solution via the control on the dropping rate of aqueous ammonia played a critical role in size distribution. The magnetic response of the product in the magnetic field was also analyzed and evaluated carefully. A 32.6 mT magnetic field which is produced by four ferromagnets was found to be sufficient to excite the dipole moments of 0.05 g Fe3O4 powder 2 cm far away from the ferromagnets. In conclusion, the Fe3O4 magnetic nanoparticles with excellent properties were competent for the magnetic carders of targeted-drug in future application.展开更多
Prunus necrotic ring spot virus (PNRSV) and grapevine fanleaf virus (GFLV) were detected by fluoroimmunoassay using bacterial magnetic particles (BMPs), and a double antibody sandwich enzyme linked immunosorbent...Prunus necrotic ring spot virus (PNRSV) and grapevine fanleaf virus (GFLV) were detected by fluoroimmunoassay using bacterial magnetic particles (BMPs), and a double antibody sandwich enzyme linked immunosorbent assay (DAS-ELISA). For the fluoroimmunoassay, fluorescein isothiocyanate labeled anti-PNRSV antibody or anti-GFLV antibody was conjugated onto BMPs of Magnetospirillum gryphiswaldense MSR-1. With this method, a very low minimum antigen concentration (1×10^6 dilution of the original sample concentration) could be detected. Using DAS-ELISA, the minimum antigen detection concentration was the original sample concentration. Thus, comparing these two methods, a BMP-based method could increase the sensitivity up to six orders of magnitude (10^6) higher than an ELISA-based method of detection PNRSV and GFLV.展开更多
Magnetic particles have numerous applications in biotechnology and biomedicine. In this paper we reviewed the synthesis, surface modification and some applications of magnetic particles with focus on their synthesis a...Magnetic particles have numerous applications in biotechnology and biomedicine. In this paper we reviewed the synthesis, surface modification and some applications of magnetic particles with focus on their synthesis and surface modification. Various methods have been developed for the production of magnetic particles (magnetic nanoparticles and magnetic composite particles). For future application magnetic particles must be modified to obtain stability and surface functional groups. Finally, the application of magnetic particles in magnetic separation, drug delivery, hyperthermia, and magnetic resonance imaging are discussed.展开更多
In this paper, the magnetic Nd-Fe-B particles of different sizes were conducted under vacuum by the hot pressing, then cooled quickly to room temperature. Finally hot deformation was performed to get the anisotropy Nd...In this paper, the magnetic Nd-Fe-B particles of different sizes were conducted under vacuum by the hot pressing, then cooled quickly to room temperature. Finally hot deformation was performed to get the anisotropy Nd-Fe- B magnet at a deformation rate of 70 % in the protection of argon atmosphere. NIM-2000 was used for the measurement of hysteresis loop of the samples. Meanwhile, scanning electron microscopy (SEM) was used to observe the surface morphology of the magnetic particles with different sizes and hot-deformed magnets, energy spectrum analyzer to analyze the composition of magnetic particles. The effect of magnetic particle sizes on the microstructure and magnetic properties of the hot-deformed anisotropic magnet was investigated. Anisotropic hot-deformed magnets produced from the maximum particle size of 200-350 μm have the highest magnetic properties of Br = 1.465 T, Hcj = 1,157 kA.m-1, (Bn)max = 425 kJ.m-3.展开更多
Magnetic particles were coupled with a flocculant to enhance the demulsification and separation of waste cutting emulsions.The optimal magnetic particle size and critical magnetic field conditions were investigated to...Magnetic particles were coupled with a flocculant to enhance the demulsification and separation of waste cutting emulsions.The optimal magnetic particle size and critical magnetic field conditions were investigated to achieve large-scale engineering application of magnetic demulsification separation for waste cutting emulsion treatment.The micro-scale magnetic particles were found to show comparable effects to nano-scale magnetic particles on enhancing the demulsification and separation of cutting emulsions,which are beneficial for broadening the selectivity of low-cost magnetic particles.The critical magnetic separation region was determined to be an area 40 mm from the magnetic field source.Compared to the flocculant demulsification,the magnetic demulsification separation exhibited a significant advantage in accelerating flocs-water separation by decreasing the separation time of flocs from 180-240 min to less than 15 min,compressing the flocs by reducing the floc volume ratio from 60%-90%to lower than 20%,and showing excellent adaptability to the variable properties of waste cutting emulsions.Coupled with the design of the magnetic disk separator,continuous demulsification separation of the waste cutting emulsion was achieved at 1.0 t/hr for at least 10 hr to obtain clear effluent with 81%chemical oxygen demand removal and 89%turbidity reduction.This study demonstrates the feasibility of applying magnetic demulsification separation to large-scale continuous treatment of waste emulsion.Moreover,it addresses the flocs-water separation problems that occur in practical flocculant demulsification engineering applications.展开更多
An unqualifed six-cylinder heavy truck crankshaft has been studied to investigate the cause of magnetic particle testing defects on the rod journals.Large-sized long-striped MnS inclusions are regarded as the major ca...An unqualifed six-cylinder heavy truck crankshaft has been studied to investigate the cause of magnetic particle testing defects on the rod journals.Large-sized long-striped MnS inclusions are regarded as the major cause for the magnetic particle testing failure because they have been detected in situ under the magnetic particle indications.Through the observation of macroscopic structures of the rod journals and corresponding counterweight blocks,it is found that for the 1#and 3#rod journals,the center metal of the original hot-rolled bar has been extruded to the inboard edge of the rod journals and large-sized long-striped MnS inclusions are exposed on the surface after fash removal,leading to the failure of magnetic particle testing.As for the 2#rod journal,the center metal of the original bar has not been extruded to the surface and MnS inclusions on the rod journal surface are small in size,few in number,resulting in passing the magnetic particle testing.If the quality of the hot-rolled bars fuctuates,it is more recommended to apply magnetic particle testing on samples at the center of bars before forging to evaluate the severity of defects caused by the long-striped MnS inclusions for fear of the scrap of the fnal crankshafts.展开更多
Magnetic particles (MPs) are the most widely used commercialized engineering particles, which gained great success in various biological applications. Inspired by their intrinsic Fe isotope composition, we discovered ...Magnetic particles (MPs) are the most widely used commercialized engineering particles, which gained great success in various biological applications. Inspired by their intrinsic Fe isotope composition, we discovered a commercialized MPs-internal standard's novel function to realize the accurate quantification of biomolecules. The bioassay of carcinoembryonic antigen (CEA) was chosen as a modal system. The Fe isotope in MPs and Au isotope in report probes were simultaneously and sensitively detected by the elemental mass spectrometry. ^(197)Au/^(57)Fe isotopic ratios and CEA concentrations showed good linearity in the range of 0.6-300 ng/mL, with a detection limit of 0.09 ng/mL (3σ). The accuracy and precision of the proposed MPs-based immunoassay were greatly improved, by eliminating potential MPs loss during magnetic separation and absolute intensity fluctuations. Considering the exceptional availability and universality of commercialized MPs, the proposed method might open a new avenue for MPs' biological applications.展开更多
Sr Fe12-xNixO19 nanoparticles(x = 0–1) were synthesized by a combustion sol–gel method. Their structure, dielectric and magnetic properties were investigated by X-ray diffraction(XRD), scanning electron microscopy(S...Sr Fe12-xNixO19 nanoparticles(x = 0–1) were synthesized by a combustion sol–gel method. Their structure, dielectric and magnetic properties were investigated by X-ray diffraction(XRD), scanning electron microscopy(SEM), an LCR metry, and vibrating sample magnetometry(VSM).The results reveal that all samples of Ni doped compounds(Sr Fe12-xNixO19) with x < 0.2 are single phase. It appears that the Fe3+ ions are substituted by Ni2+ ions on the crystallographic sites of the Sr Fe12O19 structure; however, for x ≥ 0.2, the secondary Ni phase ferrite(Ni Fe2O3) appears, which reduces the saturation magnetization and coercivity. In addition, Ni doping reduces the dielectric constant, dielectric loss, and alternating current(ac) electrical conductivity of the samples. The variation in ac conductivity(σac) with frequency shows that the electrical conductivity in these ferrites is mainly attributed to the electron hopping mechanism.Therefore; all the single-phase Ni doped samples are suitable for use in magnetic recording media and microwave devices.展开更多
文摘The control of the stability of the filament tension is one of the crucial techniques ensuring the component quality of the composite materials. The open-loop tension control system, with industrial control computer as the core, magnetic particle clutch as the actuator, equipped with compensation technique is researched and manufactured. It can assure the tension control stability of the yarn in filament winding process and increase the control precision of the whole system.
文摘Purpose: Magnetic hyperthermia treatment (MHT) is a strategy for cancer therapy using the tem-perature rise of magnetic nanoparticles (MNPs) under an alternating magnetic field (AMF). Re-cently, a new imaging method called magnetic particle imaging (MPI) has been introduced. MPI allows imaging of the spatial distribution of MNPs. The purpose of this study was to investigate the feasibility of visualizing and quantifying the intratumoral distribution and temporal change of MNPs and predicting the therapeutic effect of MHT using MPI. Materials and Methods: Colon-26 cells (1 × 106 cells) were implanted into the backs of eight-week-old male BALB/c mice. When the tumor volume reached approximately 100 mm3, mice were divided into untreated (n = 10) and treated groups (n = 27). The tumors in the treated group were directly injected with MNPs (Resovist?) with iron concentrations of 500 mM (A, n = 9), 400 mM (B, n = 8), and 250 mM (C, n = 10), respectively, and MHT was performed using an AMF with a frequency of 600 kHz and a peak amplitude of 3.5 kA/m. The mice in the treated group were scanned using our MPI scanner immediately before, immediately after, 7 days, and 14 days after MHT. We drew a region of interest (ROI) on the tumor in the MPI image and calculated the average, maximum, and total MPI values and the number of pixels by taking the threshold value for extracting the contour as 40% of the maximum MPI value (pixel value) within the ROI. These parameters in the untreated group were taken as zero. We also measured the relative tumor volume growth (RTVG) defined by (V-V0)/V0, where V0 and V are the tumor volumes immediately before and after MHT, respectively. Results: The average, maximum, and total MPI values decreased up to 7 days after MHT and remained almost constant thereafter in all groups, whereas the number of pixels tended to increase with time. The RTVG values in Groups A and B were significantly lower than those in the control group 3 days or more and 5 days or more after MHT, respectively. The above four parameters were significantly inversely correlated with the RTVG values 5, 7, and 14 days after MHT. Conclusion: MPI can visualize and quantify the intratumoral distribution and temporal change of MNPs before and after MHT. Our results suggest that MPI will be useful for predicting the therapeutic effect of MHT and for the treatment planning of MHT.
文摘Purpose: Magnetic targeting refers to the attachment of therapeutic agents to magnetizable particles such as magnetic nanoparticles (MNPs) and then applying magnetic fields to concentrate them to the targeted region such as solid tumors. The purpose of this study was to investigate the usefulness of magnetic particle imaging (MPI) for monitoring the effect of magnetic targeting using tumor-bearing mice. Materials and Methods: Colon-26 cells (1 × 106 cells) were implanted into the backs of eight-week-old male BALB/c mice. When the tumor volume reached approximately 100 mm3, the mice were divided into treated (n = 8) and untreated groups (n = 8). The tumors in the treated group were directly injected with MNPs (Resovist?, 250 mM) and a neodymium magnet was attached to the tumor surface, whereas the magnet was not attached to the tumor in the untreated group. The mice were imaged using our MPI scanner and the average and maximum MPI values were obtained by drawing a region of interest (ROI) on the tumor, with the threshold value for extracting the contour of the tumor being taken as 40% of the maximum MPI value in the ROI. The relative tumor volume growth (RTVG) was calculated from (V ? V0)/V0, where V0 and V represented the tumor volume immediately before and after the injection of MNPs, respectively. Results: The average and maximum MPI values in the treated group were significantly higher than those in the untreated group 3 days after the injection of MNPs, suggesting the effectiveness of magnetic targeting. There were no significant differences in RTVG between the two groups. Conclusion: Our preliminary results suggest that MPI is useful for monitoring the effect of magnetic targeting.
基金Project 59573011 was supported by National Natural Science Foundation of China
文摘Fe_3O_4/Polystyrene(PSt) magnetic particles with core/shell structure have been prepared in thepresence of Fe_3O_4 magnetic fluid in ethanol/water medium by dispersion polymeriation of styrene. A Fe_3O_4particle formation mechanism was proposed. According to this mechanism, the size of particle nuclei isdetermined by the extent of aggregation of Fe_3O_4 /oligomer. Magnetic particles with diameter ranging from 5to 200 μm were prepared under different reaction conditions. Some polymerization parameters such as theconcentration of monomer, stabilizer, initiator, and ethanol which affect particle size and size distribution arediscussed and their effect on particle formation are explained by the proposed mechanism.
基金supported by the U.S.Department of Energy under Award(DE-FE0001321).
文摘The influence of the magnetization of a soft magnetic sphere on the surrounding magnetic field is measured and characterized.The interaction force between two soft magnetic particles is directly measured using an ultra precision load sensor in uniform and non-uniform magnetic fields. The interaction force largely follows an inverse fourth power law as a function of separation distance between particle centers. At small distances,the effect of magnetization of one particle on the magnetization of its adjacent particle causes the attractive(repulsive) force to be larger(smaller) than that predicted by the inverse fourth power law.The theoretical prediction based on a modified dipole model,that takes into account the coupling effect of the magnetization among soft magnetic particles,gives excellent agreement with the measured force in a uniform magnetic field.The interaction force under a non-uniform applied magnetic field can be reasonably predicted using the dipole-dipole interaction model when the local magnetic field is used to determine the magnetization.
文摘Zero-temperature Monte Carlo simulations are used to investigate the hysteresis of a magnetic particle ina dipolarIsing model. The magnetic particle is described in a system of permanent dipoles, and the dipoles are locatedin a cubic lattice site. The effects of the shape and the size of the particle on the hysteresis loop at zero temperatureare obtained. For strong exchange interactions, the shapes of magnetic hysteresis loops approach rectangle. For weakexchange interactions, the effects of the size and the shape of the particle on the loops are more remarkable than thoseof strong exchange interactions case. The slope of the hysteresis loop decreases with the increase of the ratio of thesemi major axis to the semi minor axis of the ellipsoidal magnetic particle, and there is an increase of the slope of thehysteresis with the decrease of the size of the magnetic particle. The effects of the shape and size of the particle on thecoercive force at zero temperature are also investigated.
基金This work was supported in part by the National Key Research and Development Program of China,Nos.2017YFA0700401 and 2017YFA0205200the National Natural Science Foundation of China,Nos.62027901,81827808,81527805,and 81671851+2 种基金the CAS Youth Innovation Promotion Association,No.2018167the CAS Key Technology Talent Programand the Project of High-Level Talents Team Introduction in Zhuhai City,No.Zhuhai HLHPTP201703。
文摘Magnetic particle imaging(MPI)is an emerging molecular imaging technique with high sensitivity and temporal-spatial resolution.Image reconstruction is an important research topic in MPI,which converts an induced voltage signal into the image of superparamagnetic iron oxide particles concentration distribution.MPI reconstruction primarily involves system matrix-and x-space-based methods.In this review,we provide a detailed overview of the research status and future research trends of these two methods.In addition,we review the application of deep learning methods in MPI reconstruction and the current open sources of MPI.Finally,research opinions on MPI reconstruction are presented.We hope this review promotes the use of MPI in clinical applications.
基金This work is supported by the Natural Science Foundation of China(NSFC) (61027015,61177088,61107076)the National Program on Key Basic Research Project (973 Program,2012CB723405).
文摘Purpose:This work focused on the investigation the hyperthermia performance of the carboncoated magnetic particles(CCMPs)in laser-induced hyperthermia.Materials and methods:We prepared CCMPs using the organic carbonization method,and then characterized them with transmission electron microscopy(TEM),ultraviolet-visible(UV-Vis)spectrophotometry,vibrating sample magnetometer(VSM)and X-ray di®raction(XRD).In order to evaluate their performance in hyperthermia,the CCMPs were tested in laser-induced thermal therapy(LITT)experiments,in which we employed a fully distributedfiber Bragg grating(FBG)sensor to profile the tissue's dynamic temperature change under laser irradiation in real time.Results:The sizes of prepared CCMPs were about several micrometers,and the LITT results show that the tissue injected with the CCMPs absorbed more laser energy,and its temperature increased faster than the contrast tissue without CCMPs.Conclusions:The CCMPs may be of great help in hyperthermia applications.
文摘Fe_3O_4/PS magnetic particles with core/shell structure has been prepared in the presence of Fe3O4 magnetic fluid in ethanol/water mixture.Magnetic particles with diameter size range from 5. 54 t0 187. 32 μm were obtained by different reaction conditions.Some parameters such as ethanol, PEG and monomer which affect particle size diameter and size distribution are discussed briefly in this paper.
文摘The introduction of functionalized magnetizable particles for the purification of enzymes or for the multi-use of pre-immobilized biocatalysts offers a great potential for time and cost savings in biotechnological process design. The selective separation of the magnetizable particles is performed for example by a high-gradient magnetic separator. In this study FEM and CFD simulations of the magnetic field and the fluid flow field within a filter chamber of a magnetic separator were carried out, to find an optimal separator design. The motion of virtual magnetizable particles was calculated with a one-way coupled Lagrangian approach in order to test many geometric and parametric variations in reduced time. It was found that a flow homogenisator smoothed the fluid flow, so that the linear velocity became nearly equal over the cross section in the direction of flow. Furthermore the retention of magnetizable particles increases with a high total edge length within the filter matrix.
文摘The magnetization reversal process and hysteresis loops in a single crystal α-iron with nonmagnetic particles are simulated in this work based on the Landau-Lifshitz-Gilbert equation. The evolutions of the magnetic domain morphology are studied, and our analyses show that the magnetization reversal process is affected by the interaction between the moving domain wall and the existing nonmagnetic particles. This interaction strongly depends on the size of the particles, and it is found that particles with a particular size contribute the most to magnetic hardening.
文摘Objective:To explore the application value of magnetic particle chemiluminescence method in the detection of hepatitis C virus(HCV)IgM,IgG and other antibody indicators in mice.Methods:A total of 90 mice with HCV were selected as the research objects.All the mice were tested for HCV IgM and IgA antibody,and then their venous blood samples were taken to detect the antibody index by enzyme-linked immunosorbent assay,magnetic particle chemiluminescence method and indirect agglutination method,and the results and positive rates of the three groups were compared.Results:There was no significant difference in the positive rate among the three groups(P>0.05).The specificity,accuracy and sensitivity of indirect agglutination test for IgM were 90.79%,80.00%and 30.00%,respectively.The specificity,accuracy and sensitivity of magnetic particle chemiluminescence assay were 97.44%,93.33%and80.00%,respectively.The specificity,accuracy and sensitivity of indirect agglutination assay were significantly lower than those of magnetic particle chemiluminescence assay(P<0.05).For IgA,the specificity,accuracy and sensitivity of indirect agglutination assay were 90.67%,78.66%and 20.00%,respectively.The specificity,accuracy and sensitivity of magnetic particle chemiluminescence assay were 96.25%,92.35%and80.00%,respectively.The specificity,accuracy and sensitivity of indirect agglutination assay were lower than those of magnetic particle chemiluminescence assay,and the difference was statistically significant(P<0.05).Conclusion:The magnetic particle chemiluminescence method is more effective in the detection of IgM,IgG and other antibodies in mice with HCV.
基金the Technology Project of Jiangxi Provincial Education DepartmentJiangxi Provincial Science Department
文摘Fe3O4 magnetic nanoparticles were prepared by the aqueous co-precipitation of FeCl3-6H2O and FeCl2-4H2O with addition of ammonium hydroxide. The conditions for the preparation of Fe3O4 magnetic nanoparticles were optimized, and Fe3O4 magnetic nanoparticles obtained were characterized systematically by means of transmission electron microscope (TEM), dynamic laser scattering analyzer (DLS) and X-ray diffraction (XRD). The results revealed that the magnetic nanoparticles were cubic shaped and dispersive, with narrow size distribution and average diameter of 11.4 nm. It was found that the homogeneous variation of pH value in the solution via the control on the dropping rate of aqueous ammonia played a critical role in size distribution. The magnetic response of the product in the magnetic field was also analyzed and evaluated carefully. A 32.6 mT magnetic field which is produced by four ferromagnets was found to be sufficient to excite the dipole moments of 0.05 g Fe3O4 powder 2 cm far away from the ferromagnets. In conclusion, the Fe3O4 magnetic nanoparticles with excellent properties were competent for the magnetic carders of targeted-drug in future application.
文摘Prunus necrotic ring spot virus (PNRSV) and grapevine fanleaf virus (GFLV) were detected by fluoroimmunoassay using bacterial magnetic particles (BMPs), and a double antibody sandwich enzyme linked immunosorbent assay (DAS-ELISA). For the fluoroimmunoassay, fluorescein isothiocyanate labeled anti-PNRSV antibody or anti-GFLV antibody was conjugated onto BMPs of Magnetospirillum gryphiswaldense MSR-1. With this method, a very low minimum antigen concentration (1×10^6 dilution of the original sample concentration) could be detected. Using DAS-ELISA, the minimum antigen detection concentration was the original sample concentration. Thus, comparing these two methods, a BMP-based method could increase the sensitivity up to six orders of magnitude (10^6) higher than an ELISA-based method of detection PNRSV and GFLV.
基金This work was supported by the National Natural Science Foundation of China (Contract No. 30370046) "863" project (Contract No. 2002AA302211).
文摘Magnetic particles have numerous applications in biotechnology and biomedicine. In this paper we reviewed the synthesis, surface modification and some applications of magnetic particles with focus on their synthesis and surface modification. Various methods have been developed for the production of magnetic particles (magnetic nanoparticles and magnetic composite particles). For future application magnetic particles must be modified to obtain stability and surface functional groups. Finally, the application of magnetic particles in magnetic separation, drug delivery, hyperthermia, and magnetic resonance imaging are discussed.
基金financially supported by the National High Technology Research and Development Program of China(No.2011AA03A401)the National Natural Science Foundation of China(Nos.50931001,51171049,and 51271060)the National High Technology Research and Development Program of China(No.2010CB934601)
文摘In this paper, the magnetic Nd-Fe-B particles of different sizes were conducted under vacuum by the hot pressing, then cooled quickly to room temperature. Finally hot deformation was performed to get the anisotropy Nd-Fe- B magnet at a deformation rate of 70 % in the protection of argon atmosphere. NIM-2000 was used for the measurement of hysteresis loop of the samples. Meanwhile, scanning electron microscopy (SEM) was used to observe the surface morphology of the magnetic particles with different sizes and hot-deformed magnets, energy spectrum analyzer to analyze the composition of magnetic particles. The effect of magnetic particle sizes on the microstructure and magnetic properties of the hot-deformed anisotropic magnet was investigated. Anisotropic hot-deformed magnets produced from the maximum particle size of 200-350 μm have the highest magnetic properties of Br = 1.465 T, Hcj = 1,157 kA.m-1, (Bn)max = 425 kJ.m-3.
基金supported by the National Natural Science Foundation of China(No.51978490)Natural Science Foun-dation of Shanghai(No.20ZDR1461200)the Major Sci-ence and Technology Program for Water Pollution Control and Treatment,China(No.2017ZX07202003-02).
文摘Magnetic particles were coupled with a flocculant to enhance the demulsification and separation of waste cutting emulsions.The optimal magnetic particle size and critical magnetic field conditions were investigated to achieve large-scale engineering application of magnetic demulsification separation for waste cutting emulsion treatment.The micro-scale magnetic particles were found to show comparable effects to nano-scale magnetic particles on enhancing the demulsification and separation of cutting emulsions,which are beneficial for broadening the selectivity of low-cost magnetic particles.The critical magnetic separation region was determined to be an area 40 mm from the magnetic field source.Compared to the flocculant demulsification,the magnetic demulsification separation exhibited a significant advantage in accelerating flocs-water separation by decreasing the separation time of flocs from 180-240 min to less than 15 min,compressing the flocs by reducing the floc volume ratio from 60%-90%to lower than 20%,and showing excellent adaptability to the variable properties of waste cutting emulsions.Coupled with the design of the magnetic disk separator,continuous demulsification separation of the waste cutting emulsion was achieved at 1.0 t/hr for at least 10 hr to obtain clear effluent with 81%chemical oxygen demand removal and 89%turbidity reduction.This study demonstrates the feasibility of applying magnetic demulsification separation to large-scale continuous treatment of waste emulsion.Moreover,it addresses the flocs-water separation problems that occur in practical flocculant demulsification engineering applications.
基金The authors are grateful to the financial support provided by the National Natural Science Foundation of China(Grant Nos.51874034 and 51674024).
文摘An unqualifed six-cylinder heavy truck crankshaft has been studied to investigate the cause of magnetic particle testing defects on the rod journals.Large-sized long-striped MnS inclusions are regarded as the major cause for the magnetic particle testing failure because they have been detected in situ under the magnetic particle indications.Through the observation of macroscopic structures of the rod journals and corresponding counterweight blocks,it is found that for the 1#and 3#rod journals,the center metal of the original hot-rolled bar has been extruded to the inboard edge of the rod journals and large-sized long-striped MnS inclusions are exposed on the surface after fash removal,leading to the failure of magnetic particle testing.As for the 2#rod journal,the center metal of the original bar has not been extruded to the surface and MnS inclusions on the rod journal surface are small in size,few in number,resulting in passing the magnetic particle testing.If the quality of the hot-rolled bars fuctuates,it is more recommended to apply magnetic particle testing on samples at the center of bars before forging to evaluate the severity of defects caused by the long-striped MnS inclusions for fear of the scrap of the fnal crankshafts.
基金supported by the National Natural Science Foundation of China (Nos.22074096 and 22074098)Talents Program of Sichuan Province (No.903)+1 种基金1.3.5 Project for Disciplines of Excellence of West China Hospital,Sichuan University (No.ZYJC18037)the Fundamental Research Funds for the Central Universities(No.20826041D4117)。
文摘Magnetic particles (MPs) are the most widely used commercialized engineering particles, which gained great success in various biological applications. Inspired by their intrinsic Fe isotope composition, we discovered a commercialized MPs-internal standard's novel function to realize the accurate quantification of biomolecules. The bioassay of carcinoembryonic antigen (CEA) was chosen as a modal system. The Fe isotope in MPs and Au isotope in report probes were simultaneously and sensitively detected by the elemental mass spectrometry. ^(197)Au/^(57)Fe isotopic ratios and CEA concentrations showed good linearity in the range of 0.6-300 ng/mL, with a detection limit of 0.09 ng/mL (3σ). The accuracy and precision of the proposed MPs-based immunoassay were greatly improved, by eliminating potential MPs loss during magnetic separation and absolute intensity fluctuations. Considering the exceptional availability and universality of commercialized MPs, the proposed method might open a new avenue for MPs' biological applications.
基金Shahid Chamran University of Ahvaz for providing us with financial support for this project
文摘Sr Fe12-xNixO19 nanoparticles(x = 0–1) were synthesized by a combustion sol–gel method. Their structure, dielectric and magnetic properties were investigated by X-ray diffraction(XRD), scanning electron microscopy(SEM), an LCR metry, and vibrating sample magnetometry(VSM).The results reveal that all samples of Ni doped compounds(Sr Fe12-xNixO19) with x < 0.2 are single phase. It appears that the Fe3+ ions are substituted by Ni2+ ions on the crystallographic sites of the Sr Fe12O19 structure; however, for x ≥ 0.2, the secondary Ni phase ferrite(Ni Fe2O3) appears, which reduces the saturation magnetization and coercivity. In addition, Ni doping reduces the dielectric constant, dielectric loss, and alternating current(ac) electrical conductivity of the samples. The variation in ac conductivity(σac) with frequency shows that the electrical conductivity in these ferrites is mainly attributed to the electron hopping mechanism.Therefore; all the single-phase Ni doped samples are suitable for use in magnetic recording media and microwave devices.